18 results  1 of 1 

1 Use of quantitative magnetic resonance angiography in patients with symptomatic intracranial arterial stenosis who undergo stenting: Presentation of three cases
Yafell Serulle, Deepak Khatri, Heustein Sy, Srinivasu Yerneni, David Langer, Rafael Ortiz
J Cerebrovasc Endovasc Neurosurg.2021;23(2):136-144.   Published online 2021 June 10     DOI: http://dx.doi.org/10.7461/jcen.2021.E2020.10.005
      
2 Evaluation of Inferior Capsular Laxity in Patients with Atraumatic Multidirectional Shoulder Instability with Magnetic Resonance Arthrography
Kyoung-Jin Park, Ho-Seung Jeong, Ji-Kang Park, Jung-Kwon Cha, Sang-Woo Kang
Korean J Radiol.2019;20(6):931-938.   Published online 2019 April 26     DOI: http://dx.doi.org/10.3348/kjr.2018.0541
      
3 Accelerated Time-of-Flight Magnetic Resonance Angiography with Sparse Undersampling and Iterative Reconstruction for the Evaluation of Intracranial Arteries
Hehan Tang, Na Hu, Yuan Yuan, Chunchao Xia, Xiumin Liu, Panli Zuo, Aurelien F. Stalder, Michaela Schmidt, Xiaoyue Zhou, Bin Song, Jiayu Sun
Korean J Radiol.2019;20(2):265-274.   Published online 2018 December 28     DOI: http://dx.doi.org/10.3348/kjr.2017.0634
      
4 Left Gastric Vein Visualization with Hepatopetal Flow Information in Healthy Subjects Using Non-Contrast-Enhanced Magnetic Resonance Angiography with Balanced Steady-State Free-Precession Sequence and Time-Spatial Labeling Inversion Pulse
Akihiro Furuta, Hiroyoshi Isoda, Tsuyoshi Ohno, Ayako Ono, Rikiya Yamashita, Shigeki Arizono, Aki Kido, Naotaka Sakashita, Kaori Togashi
Korean J Radiol.2018;19(1):32-39.   Published online 2018 January 2     DOI: http://dx.doi.org/10.3348/kjr.2018.19.1.32
      
5 Mismatch between TOF MR Angiography and CT Angiography of the Middle Cerebral Artery may be a Critical Sign in Cerebrovascular Dynamics
Keiji Igase, Michiya Igase, Ichiro Matsubara, Kazuhiko Sadamoto
Yonsei Med J.2018;59(1):80-84.   Published online 2017 November 29     DOI: http://dx.doi.org/10.3349/ymj.2018.59.1.80
      
6 Susceptibility Vessel Sign for the Detection of Hyperacute MCA Occlusion: Evaluation with Susceptibility-weighted MR Imaging
Sangmin Lee, Soo Bueum Cho, Dae Seob Choi, Sung Eun Park, Hwa Seon Shin, Hye Jin Baek, Ho Cheol Choi, Ji-Eun Kim, Hye Young Choi, Mi Jung Park
Investig Magn Reson Imaging.2016;20(2):105-113.   Published online 2016 June 30     DOI: http://dx.doi.org/10.13104/imri.2016.20.2.105
      
7 Time-of-Flight Magnetic Resonance Angiography for Follow-Up of Coil Embolization with Enterprise Stent for Intracranial Aneurysm: Usefulness of Source Images
Young Dae Cho, Kang Min Kim, Woong Jae Lee, Chul-Ho Sohn, Hyun-Seung Kang, Jeong Eun Kim, Moon Hee Han
Korean J Radiol.2014;15(1):161-168.   Published online 2014 January 8     DOI: http://dx.doi.org/10.3348/kjr.2014.15.1.161
      
8 Rat Model of Hindlimb Ischemia Induced via Embolization with Polyvinyl Alcohol and N-Butyl Cyanoacrylate
Cheong-Il Shin, Hyo-Cheol Kim, Yong Sub Song, Hye Rim Cho, Kyoung-Bun Lee, Whal Lee, Hwan Jun Jae, Jin Wook Chung
Korean J Radiol.2013;14(6):923-930.   Published online 2013 November 5     DOI: http://dx.doi.org/10.3348/kjr.2013.14.6.923
      
9 Persistent Proatlantal Artery in Magnetic Resonance Angiography: A Case Report
Seong Woo Jeon, Hyuk Won Chang, Mi Jung Kim, Jihyoung Cho
J Korean Soc Magn Reson Med.2013;17(1):55-58.   Published online 2013 March 27     DOI: http://dx.doi.org/10.13104/jksmrm.2013.17.1.55
      
10 Pseudostenosis at the Origin of the Vertebral Artery on Contrast-enhanced MRA: Correlation with Aortic Motion on Dynamic 3D Time-Resolved Contrast-Enhanced MRA
Seonmun Kim, Sungwon Lee, Hyun Seok Choi, So-Lyung Jung, Kook-Jin Ahn, Bum-soo Kim
J Korean Soc Magn Reson Med.2012;16(3):236-242.   Published online 2012 December 31     DOI: http://dx.doi.org/10.13104/jksmrm.2012.16.3.236
      
11 The Brain MRI and MRA Findings of Patients Who Visited Memory Disorder Clinic in a General Hospital
Jun-Hyung Lee, Soo-Ji Lee, Jin-Young Ahn, Jae-Hyeok Heo
Dement Neurocogn Disord.2012;11(4):124-130.   Published online 2012 December 31     DOI: http://dx.doi.org/10.12779/dnd.2012.11.4.124
      
12 Reconstruction of Stereo MR Angiography Optimized to View Position and Distance using MIP
Seok-Hyun Shin, Do-Sik Hwang
J Korean Soc Magn Reson Med.2012;16(1):67-75.   Published online 2012 April 30     DOI: http://dx.doi.org/10.13104/jksmrm.2012.16.1.67
      
13 Comparison of Non-invasive Imaging Studies in the Evaluation of Carotid Artery Stenosis and Occlusion: CT Angiography, Time-of-Flight MR Angiography and Contrast-Enhanced MR Angiography
Junhyung Lee, Tae-Sub Chung, Kyung-Yul Lee, Sang Hyun Suh
J Korean Soc Magn Reson Med.2011;15(3):234-241.   Published online 2011 December 31     DOI: http://dx.doi.org/10.13104/jksmrm.2011.15.3.234
      
14 Time-Resolved 3D Contrast-Enhanced MRA on 3.0T: a Non-Invasive Follow-Up Technique after Stent-Assisted Coil Embolization of the Intracranial Aneurysm
Jin Woo Choi, Hong Gee Roh, Won-Jin Moon, Na Ra Kim, Sung Gyu Moon, Chung Hwan Kang, Young Il Chun, Hyun-Seung Kang
Korean J Radiol.2011;12(6):662-670.   Published online 2011 September 27     DOI: http://dx.doi.org/10.3348/kjr.2011.12.6.662
      
15 Application of Magnetic Resonance Imaging and Magnetic Resonance Angiography as Diagnostic Measures for the First Attack of Suspected Cerebrovascular Diseases in Korea
Kunsei Lee, Hyeongsu Kim, Jae-Hyeok Heo, Hee-Joon Bae, Im-Seok Koh, Sounghoon Chang
Yonsei Med J.2011;52(5):727-733.   Published online 2011 July 18     DOI: http://dx.doi.org/10.3349/ymj.2011.52.5.727
      
16 Diagnosis of Vertebral Artery Ostial Stenosis on Contrast-Enhanced MR Angiography: Usefulness of a Thin-Slab MIP Technique
Sun Mi Kim, Deok Hee Lee, Jin Woo Choi, Byung Se Choi, Hyun Sin In
J Korean Soc Magn Reson Med.2011;15(1):77-81.   Published online 2011 April 30     DOI: http://dx.doi.org/10.13104/jksmrm.2011.15.1.77
      
17 Hemodynamical Assessment of Cavernous Hemangioma in Cavernous Sinus Using MR-DSA and Conventional DSA
Yong Woon Shim, Tae Sub Chung, Won Suk Kang, Kyu Sung Lee, Ralph Strecker, Juergen Hennig
Yonsei Med J.2003;44(5):908-914.   Published online 2009 March 30     DOI: http://dx.doi.org/10.3349/ymj.2003.44.5.908
      
18 Non-Invasive Follow-up Evaluation of Post-Embolized AVM with Time-Resolved MRA: A Case Report
Yong Woon Shim, Tae-Sub Chung, Won-Suk Kang, Jin-Yang Joo, Ralph Strecker, Juergen Hennig
Korean J Radiol.2002;3(4):271-275.   Published online 2002 December 31     DOI: http://dx.doi.org/10.3348/kjr.2002.3.4.271
      

 1 of 1