14 results

83 Status of Domestic and International Recommendations for Protection Design and Evaluation of Medical Linear Accelerator Facilities
Sang Hyoun Choi, Dong Oh Shin, Jae-ik Shin, Na Hye Kwon, So Hyun Ahn, Dong Wook Kim
KMSID: 1148715   Prog Med Phys. 2021;32(4):83-91.   Published online 2021 December 31    DOI: http://dx.doi.org/10.14316/pmp.2021.32.4.83
      
92 Estimation of Noise Level and Edge Preservation for Computed Tomography Images: Comparisons in Iterative Reconstruction
Sihwan Kim, Chulkyun Ahn, Woo Kyoung Jeong, Jong Hyo Kim, Minsoo Chun
KMSID: 1148716   Prog Med Phys. 2021;32(4):92-98.   Published online 2021 December 31    DOI: http://dx.doi.org/10.14316/pmp.2021.32.4.92
      
99 Dosimetric Study Using Patient-Specific Three-Dimensional-Printed Head Phantom with Polymer Gel in Radiation Therapy
Yona Choi, Kook Jin Chun, Eun San Kim, Young Jae Jang, Ji-Ae Park, Kum Bae Kim, Geun Hee Kim, Sang Hyoun Choi
KMSID: 1148717   Prog Med Phys. 2021;32(4):99-106.   Published online 2021 December 31    DOI: http://dx.doi.org/10.14316/pmp.2021.32.4.99
      
107 A Comparison between Portal Dosimetry and Mobius3D Results for Patient-Specific Quality Assurance in Radiotherapy
Sung Yeop Kim, Jaehyeon Park, Jae Won Park, Ji Woon Yea, Se An Oh
KMSID: 1148707   Prog Med Phys. 2021;32(4):107-115.   Published online 2021 December 31    DOI: http://dx.doi.org/10.14316/pmp.2021.32.4.107
      
116 Evaluating the Effects of Dose Rate on Dynamic Intensity-Modulated Radiation Therapy Quality Assurance
Kwon Hee Kim, Tae Seong Back, Eun Ji Chung, Tae Suk Suh, Wonmo Sung
KMSID: 1148708   Prog Med Phys. 2021;32(4):116-121.   Published online 2021 December 31    DOI: http://dx.doi.org/10.14316/pmp.2021.32.4.116
      
122 Design of Multipurpose Phantom for External Audit on Radiotherapy
Sangwook Lim
KMSID: 1148705   Prog Med Phys. 2021;32(4):122-129.   Published online 2021 December 31    DOI: http://dx.doi.org/10.14316/pmp.2021.32.4.122
      
130 Dosimetric Comparison between Varian Halcyon Analytical Anisotropic Algorithm and Acuros XB Algorithm for Planning of RapidArc Radiotherapy of Cervical Carcinoma
Jonathan Mbewe, Sakhele Shiba
KMSID: 1148704   Prog Med Phys. 2021;32(4):130-136.   Published online 2021 December 31    DOI: http://dx.doi.org/10.14316/pmp.2021.32.4.130
      
137 Development of a Beam Source Modeling Approach to Calculate Head Scatter Factors for a 6 MV Unflattened Photon Beam
So-Yeon Park, Noorie Choi, Na Young Jang
KMSID: 1148709   Prog Med Phys. 2021;32(4):137-144.   Published online 2021 December 31    DOI: http://dx.doi.org/10.14316/pmp.2021.32.4.137
      
145 Measurements of Neutron Activation and Dose Rate Induced by High-Energy Medical Linear Accelerator
Na Hye Kwon, Young Jae Jang, Jinsung Kim, Kum Bae Kim, Jaeryong Yoo, So Hyun Ahn, Dong Wook Kim, Sang Hyoun Choi
KMSID: 1148706   Prog Med Phys. 2021;32(4):145-152.   Published online 2021 December 31    DOI: http://dx.doi.org/10.14316/pmp.2021.32.4.145
      
153 Characteristic Evaluation of Pressure Mapping System for Patient Position Monitoring in Radiation Therapy
Seonghee Kang, Chang Heon Choi, Jong Min Park, Jin-Beom Chung, Keun-Yong Eom, Jung-in Kim
KMSID: 1148711   Prog Med Phys. 2021;32(4):153-158.   Published online 2021 December 31    DOI: http://dx.doi.org/10.14316/pmp.2021.32.4.153
      
159 Assessing Commercial CLEANBOLUS Based on Silicone for Clinical Use
Jaeman Son, Seongmoon Jung, Jong Min Park, Chang Heon Choi, Jung-in Kim
KMSID: 1148710   Prog Med Phys. 2021;32(4):159-164.   Published online 2021 December 31    DOI: http://dx.doi.org/10.14316/pmp.2021.32.4.159
165 Effect of Total Collimation Width on Relative Electron Density, Effective Atomic Number, and Stopping Power Ratio Acquired by Dual-Layer Dual-Energy Computed Tomography
Seongmoon Jung, Bitbyeol Kim, Euntaek Yoon, Jung-in Kim, Jong Min Park, Chang Heon Choi
KMSID: 1148712   Prog Med Phys. 2021;32(4):165-171.   Published online 2021 December 31    DOI: http://dx.doi.org/10.14316/pmp.2021.32.4.165
      
172 Synthetic Computed Tomography Generation while Preserving Metallic Markers for Three-Dimensional Intracavitary Radiotherapy: Preliminary Study
Hyeongmin Jin, Seonghee Kang, Hyun-Cheol Kang, Chang Heon Choi
KMSID: 1148713   Prog Med Phys. 2021;32(4):172-178.   Published online 2021 December 31    DOI: http://dx.doi.org/10.14316/pmp.2021.32.4.172
      
179 Dosimetric Characteristics of Flexible Radiochromic Film Based on LiPCDA
Seongmoon Jung, Jin Dong Cho, Jung-in Kim, Jong Min Park, Chang Heon Choi
KMSID: 1148714   Prog Med Phys. 2021;32(4):179-184.   Published online 2021 December 31    DOI: http://dx.doi.org/10.14316/pmp.2021.32.4.179
      
Articles from Progress in Medical Physics are provided here courtesy of Korean Society of Medical Physics