21 results  1 of 2 

1 Feasibility and reliability of various morphologic features on magnetic resonance imaging for iliotibial band friction syndrome
Jin Kyem Kim, Taeho Kim, Hong Seon Lee, Dong Kyu Kim
Korean J Pain.2023;36(2):208-215.   Published online 2023 February 28     DOI: http://dx.doi.org/10.3344/kjp.22399
      
2 Effectiveness of medical coating materials in decreasing friction between orthodontic brackets and archwires
Nursel Arici, Berat S. Akdeniz, Abdullah A. Oz, Yucel Gencer, Mehmet Tarakci, Selim Arici
Korean J Orthod.2021;51(4):270-281.   Published online 2021 July 25     DOI: http://dx.doi.org/10.4041/kjod.2021.51.4.270
      
3 The role of the iliotibial band cross-sectional area as a morphological parameter of the iliotibial band friction syndrome: a retrospective pilot study
Jiyeon Park, Hyung Rae Cho, Keum Nae Kang, Kun Woong Choi, Young Soon Choi, Hye-Won Jeong, Jungmin Yi, Young Uk Kim
Korean J Pain.2021;34(2):229-233.   Published online 2021 April 1     DOI: http://dx.doi.org/10.3344/kjp.2021.34.2.229
      
4 Effect of archwire stiffness and friction on maxillary posterior segment displacement during anterior segment retraction: A three-dimensional finite element analysis
Choon-Soo Park, Hyung-Seog Yu, Jung-Yul Cha, Sung-Seo Mo, Kee-Joon Lee
Korean J Orthod.2019;49(6):393-403.   Published online 2019 November 26     DOI: http://dx.doi.org/10.4041/kjod.2019.49.6.393
      
5 Finite element analysis of the effect of novel Lock Screw system preventing abutment screw loosening
Eun Sub Im, Jong Eun Kim, Jee Hwan Kim, Young Bum Park
J Dent Rehabil Appl Sci.2019;35(3):132-142.   Published online 2019 September 30     DOI: http://dx.doi.org/10.14368/jdras.2019.35.3.132
      
6 In-vitro investigation of the mechanical friction properties of a computer-aided design and computer-aided manufacturing lingual bracket system under diverse tooth displacement condition
Do-Yoon Kim, Sang-Woon Ha, Il-Sik Cho, Il-Hyung Yang, Seung-Hak Baek
Korean J Orthod.2019;49(2):73-80.   Published online 2019 March 19     DOI: http://dx.doi.org/10.4041/kjod.2019.49.2.73
      
7 Result of Charnley Low Friction Arthroplasty in Old Tuberculosis of the Hip
Chul Un Ko, Young Yong Kim, Ik San Kim
J Korean Orthop Assoc.1985;20(5):797-806.   Published online 2019 February 22     DOI: http://dx.doi.org/10.4055/jkoa.1985.20.5.797
      
8 Clinical Report by using hybrid telescopic double crown Removable Partial Denture on a few remaining teeth with severe periodontal disease
Jang-Won Seo, Cheong-Hee Lee
J Korean Acad Prosthodont.2019;57(1):24-30.   Published online 2019 January 22     DOI: http://dx.doi.org/10.4047/jkap.2019.57.1.24
      
9 Prosthetic rehabilitation for patient with hemi-maxillectomy:Obturator combined with a hybrid telescopic double crown using friction pin
Jeong-Gyo Seo, Jin-Hyun Cho
J Dent Rehabil Appl Sci.2018;34(4):317-323.   Published online 2018 December 31     DOI: http://dx.doi.org/10.14368/jdras.2018.34.4.317
      
10 Treatment of the cleft lip and palate patient with few remaining posterior teeth using hybrid telescopic crown denture
Jin-Wook Park, Jin-Hyun Cho
J Dent Rehabil Appl Sci.2017;33(4):284-290.   Published online 2017 December 30     DOI: http://dx.doi.org/10.14368/jdras.2017.33.4.284
      
11 Improvement of Lubrication Properties for New Surface Structure with Regular Patterning for the Frictional Surfaces of the Artificial Joints: Evaluation of Lubrication Properties by the Pendulum Type Hip Joint Simulator
Dong Wook Kim, Toshio Yuhta, Kyung Wook Lee, Soo Jae Yim
J Korean Orthop Assoc.2004;39(7):745-752.   Published online 2017 December 28     DOI: http://dx.doi.org/10.4055/jkoa.2004.39.7.745
   
12 Hybrid telescopic double crown denture on maxillary few remaining teeth and 2 mandibular implants in case of failed implant overdenture
Seok-Joon Ha, Jin-Hyun Cho
J Korean Acad Prosthodont.2016;54(3):246-252.   Published online 2016 December 18     DOI: http://dx.doi.org/10.4047/jkap.2016.54.3.246
   
13 A clinical case of hybrid telescopic double crown using friction pin with an isolated few remaining teeth
Sang-Hyuk Sohn, Jin-Hyun Cho, Sung-Am Cho
J Dent Rehabil Appl Sci.2016;32(1):80-86.   Published online 2016 March 31     DOI: http://dx.doi.org/10.14368/jdras.2016.32.1.80
      
14 Effect of passive self-ligating bracket placement on the posterior teeth on reduction of frictional force in sliding mechanics
Kyu-Ry Kim, Seung-Hak Baek
Korean J Orthod.2016;46(2):73-80.   Published online 2016 March 18     DOI: http://dx.doi.org/10.4041/kjod.2016.46.2.73
      
15 Comparison of the frictional characteristics of aesthetic orthodontic brackets measured using a modified in vitro technique
Nursel Arici, Berat Serdar Akdeniz, Selim Arici
Korean J Orthod.2015;45(1):29-37.   Published online 2015 January 26     DOI: http://dx.doi.org/10.4041/kjod.2015.45.1.29
      
16 Intra-Articular Fibroma of Tendon Sheath in a Knee Joint Associated with Iliotibial Band Friction Syndrome
Dong-Ho Ha, Sunseob Choi, Soo-Jin Kim, Wang Lih
Korean J Radiol.2015;16(1):169-174.   Published online 2015 January 9     DOI: http://dx.doi.org/10.3348/kjr.2015.16.1.169
      
17 Pesriodontal prosthesis on medically compromised patient with few remaining teeth: hybrid telescopic double crown with friction pin method
Seok-Joon Ha, Cheong-Hee Lee, Jin-Hyun Cho
J Korean Acad Prosthodont.2014;52(4):359-365.   Published online 2014 February 9     DOI: http://dx.doi.org/10.4047/jkap.2014.52.4.359
   
18 The comparison of the frictional force by the type and angle of orthodontic bracket and the coated or non-coated feature of archwire
Tae-Ho Jang, Sang-Cheol Kim, Jin-Hyoung Cho, Jong-Moon Chae, Na-Young Chang, Kyung Hwa Kang
Korean J Orthod.2011;41(6):399-410.   Published online 2011 December 30     DOI: http://dx.doi.org/10.4041/kjod.2011.41.6.399
      
19 Effect of friction from differing vertical bracket placement on the force and moment of NiTi wires
Jea-Beom Park, Ji-A Yoo, Sung-Seo Mo, Kwang-Cheol Choi, Yoon-Ji Kim, Seong Ho Han, Yoon-Ah Kook
Korean J Orthod.2011;41(5):337-345.   Published online 2011 October 31     DOI: http://dx.doi.org/10.4041/kjod.2011.41.5.337
      
20 Changes in surface roughness of bracket and wire after experimental sliding - preliminary study using an atomic force microscopy
Tae-Hee Lee, Ki-Ho Park, Ji-Yun Jeon, Su-Jung Kim, Hun-Kuk Park, Young-Guk Park
Korean J Orthod.2010;40(3):156-166.   Published online 2010 June 30     DOI: http://dx.doi.org/10.4041/kjod.2010.40.3.156
      

 1 of 2