J Korean Soc Echocardiogr. 1997 Jul;5(1):13-20. Korean.
Published online July 31, 1997.  https://doi.org/10.4250/jkse.1997.5.1.13
Copyright © 1997 Korean Society of Echocardiography
Comparison of Mitral Doppler Flow, Flow Propagation Velocity and Peak Filling Rate between Patients with Normal and Systolic LV Dysfunction in Presence of Atrial Fibrillation
Jin Yong Hwang and Bong Gown Seo
Department of Internal Medicine, School of Medicine, University of Gyung Sang, Jinju, Korea.
Abstract

BACKGROUND

Methods for evaluating left ventricular diastolic function have been used exclusively in cardiac patients in sinus rhythm and have not been applied to atrial fibrillation because of large cycle variation in flow velocities and absence of atrial contraction. The utility of these rnethods in atrial fibrillation is unknown, especially M-rnode Doppler echocardiography and automatic border detection method.

METHOD

Left Ventricular Normal group(LVN group, Ejection fraction> 40%) of 21 patients(mean age 67 years old, 12 men, 9 women) and Left Ventricular Dysfunction group (LVD group, EF ( 40%) of 15 patients(mean age 64 years old, 11 men, 4 women) were studied. We measured parameters in pulsed Doppler recordings of rnitral flow velocity and the flow propagation velocity in color M-mode recording of mitral flow, and peak filling rate from automatic border detection system. Measurements were averaged over 10 cardiac cycles.

RESULTS

Mean heart rates were not different in both population(LVN 79±18/min, LVD 83±16/min). Left ventricular diastolic dimension were more dilated LVD group than LVN group(5.7±1.0crn, 4.6±0.7cm p < 0.05) but left atrial dimension were similar(4.4±0.8cm, 4.3±0.7cm). Deceleration time was significantly shortened in LVD group(158.4±24.4ms vs. 180.4+37.6ms, p < 0.05) but other parameters of mitral pulsed Doppler recording such as IVRT, acceleration time, acceleration rate and deceleration rate were not different. Flow propagation velocities were significantly decreased in LVD group(41.7±14.9cm/s vs. 53.0±11. 9cm/s, p < 0.05). Peak filling rates of automatic border detection system were significantly decreased in LVD group(3.4±1.2 EDV/s vs 5.4±1.1 EDV/s, p< 0.001).

CONCLUSION

Echocardiographic measurements of diastolic function via color M-mode Doppler and autornatic border detection may be useful in presence of atrial fibrillation as sinvs rhythm.

Keywords: Atrial fibrillation; Color M-mode doppler; Automatic border detection

TOOLS
Similar articles

Assessment of Left Ventricular Diastolic Dysfunction by Intraventricular Dispersion of Early Diastolic Filling

Evaluation of the Left Atrial Size and Function in Addition to Analysis of the Mitral and Pulmonary Venous Flow Velocity in the Estimation of Left Ventricular Filling Pressures

Echocardiographic Doppler Mitral Valve Flow Velocity In Hypertension

Doppler Echocardiographic Evaluation of Left Ventricular Filling in Hypertensive Subjects

Mitral Ring Motion and Transmitral Blood Flow Velocity in Dilated Cardiomyopathy