Journal List > Arch Hand Microsurg > v.29(2) > 1516087288

Yun, Kim, Hwang, Jung, and Hwang: Changes in force generation by two-finger striking methods: an experimental study

Abstract

Purpose

Acute sagittal injury in boxer’s knuckle causes extensor tendon subluxation. We analyzed anatomical measurements for posture-related hand parts and measured the force generated when striking the fingers.

Methods

In 120 healthy adults (55 males, 65 females), the palm area, finger length, finger length, finger circumference, and wrist circumference were measured. Using a digital force gauge, the force generated by striking with finger flexion (FFF) performed by the middle finger was measured. The forces generated during extension flicking (FEFs) by the index and ring fingers were also measured. The force exerted by the hand and fingers was measured using a grip force meter. The relationships of measured values with sex and age were statistically analyzed.

Results

The FFF of the middle finger was 12.9±7.0 N, and the FEFs of the index and ring fingers were 6.8±2.5 N and 5.8±2.3 N, respectively. The grip force was 343.3±134.7 N in the four fingers excluding the thumb, 108.4±41.6 N in the index finger, 110.5±45.4 N in the middle finger, and 83.6±36.5 N in the ring finger. Males had higher FFF for the middle finger (17.9±6.6 N) than females (8.6±3.9 N) (p<0.001), and greater FEFs for the index (8.5±2.0 N) and ring fingers (7.1±2.2 N) compared to females (5.3±1.7 N and 4.7±.8 N, respectively) (p<0.001). Cross-analysis results showed differences by sex and age. The circumference of the index finger exceeded that of the ring finger.

Conclusion

The study findings shed light on the relationship between the forces generated in the process of finger flicking.

Introduction

Finger striking is frequently used in children’s and adolescents’ play. Recently, the court found a teacher guilty of harassment for the ‘finger striking’ of an infant at a childcare facility. However, finger striking can cause subluxation of the sagittal band for the extensor tendon [1-3].
Spontaneous ruptures are caused by snapping, crossing a finger or crumpling paper, or light manual effort during normal daily activities. Spontaneous ruptures are located at the insertion of the sagittal band on the radial side of the extensor digitorum communis. Traumatic ruptures occur during a direct blow or powerful grasp and involve both the superficial and deep layers of the sagittal band [4].
Despite its importance in biomechanics and hand surgery, it is not known how much force finger striking may generate. The aim of this study is to elucidate the force that finger striking generates.

Methods

1. Participants

One hundred and twenty healthy Korean people without arthritis (55 males, 65 females) were volunteered.

2. Measurements

Palm area

A hand is placed on A4 paper marked with a 1-cm scale, the shape is drawn, the image is scanned, the ImageJ program is run, the image to be analyzed is loaded, and ‘Image → Type → 8-bit’ is set as the default setting. The scale is set based on a straight bar, a size of 1 cm is entered as the known distance in cm, and it is drawn according to the shape of the hand. The area fraction of the image is obtained by analyzing the size of the images on the appropriate screen by measuring the scale marked with the ImageJ program.

Length of fingers

The thumb, index finger, middle finger, and ring finger were measured.

Circumference of fingers and wrist

The thumb at the interphalangeal (IP) joint, index finger at the proximal IP (PIP) joint, middle finger at the PIP joint, ring finger at the PIP joint, and wrist were measured.

Force generated by striking with finger flexion

Tensiometer (basic force gauge [BFG], 200 N; Mecmesin Co, Slinfold, United Kingdom). The display was measured as 0 during gauge operation, and the measurement unit was selected as newton (N). The test was carried out by measuring the displayed value of the maximum compression force identified by the symbol. The BFG digital force gauge clearly displays live load for continuous monitoring and utilizes a peak hold function to capture the maximum (Fig. 1A). In the middle finger, the average value was analyzed by measuring the force when the third finger was bent and extended with a maximum force three times with the elbow bent at 90° while sitting in a chair and the forearm and wrist in a neutral position. A 30-second break was taken between each measurement.

Force generated during extension flicking

The test was carried out by measuring the display as ‘0’ while the gauge was operating, selecting the measurement unit as N, and measuring the displayed value of the maximum compression force identified by the symbol. The BFG digital force gauge clearly displays live load for continuous monitoring and utilizes a peak hold function to capture the maximum compression reading. The force of bending and unfolding the index finger close to the load cell corresponding to the transducer part that converts the force corresponding to the hitting part into a measurable electrical output was measured three times and averaged (Fig. 1B). Similarly, the force of bending and unfolding the ring finger was measured three times and averaged. However, in the case of the middle finger, if the force generated during extension flicking (FEF) is also measured after measuring the force generated by striking with finger flexion (FFF), an error in the FEF value may occur and it may be measured as relatively less due to the added fatigue to the joint. Therefore, to prevent this bias, FEF values were measured only on the index and ring fingers.
• Index finger: The average value was analyzed by measuring the force when the second finger was bent and extended with maximum force over three times with the elbow bent at 90° while sitting in a chair and the forearm and wrist in a neutral position. A 30-second break was taken between each measurement.
• Ring finger: While sitting in a chair, the elbow was bent at 90°, the forearm and wrist were placed in a neutral position, and the force when the fourth finger was bent and extended with maximum force was measured three times. The average value was analyzed. A 30-second break was taken between each measurement.

Maximal force of exertion on grasping

The force was measured using an Electronic Hand Dynamometer (LS Networks Co. Ltd., Seoul, Korea). In fingers from the index finger to the little finger, maximum joint strengths were measured from the flexors of the four fingers, thumb, along with the forearm muscles (Fig. 2).

Statistical analysis

In this study, IBM SPSS Statistics for Windows, ver. 23.0 (IBM Corp., Armonk, NY, USA) was used. Descriptive statistics were used to investigate the general characteristics of the research subjects, and the independent sample t-test was conducted to verify whether there was a significant difference according to sex. Each measured value was expressed as a mean±standard deviation. One-way analysis of variance was conducted to verify whether there was a difference between each age group. A Scheffé post-hoc analysis was conducted for variables showing significant differences for post-hoc verification. Before checking the significance of the independent variables in a simple linear regression analysis, the goodness of fit and explanatory power of the regression model was checked. The statistical significance level was set at p<0.05.

Results

The 120 participants included 55 males (45.8%) and 65 females (54.2%). They were divided into three age groups according to their age ranges (20–29 years, 34 [28.3%], 30–39 years, 30 [25.0%], and over 40 years, 56 [46.7%]) (Table 1).
The palm area was significantly wider in males (181.4±15.1 cm2) than in females (155.1±14.0 cm2) (p<0.001). Hand surface area (HSA) was significantly wider in males (87.4±11.3 cm2) than in females (70±9 cm2) (p<0.001). The lengths of the thumb, index finger, middle finger, ring finger, and palm were significantly longer in males (5.6±0.4 cm, 6.9±0.6 cm, 7.5±0.6 cm, 7.0±0.5 cm, and 10.4±0.6 cm, respectively) than in females (5.1±0.5 cm, 6.4±0.5 cm, 7.0±0.5 cm, 6.5±0.5 cm, and 9.5±0.6 cm, respectively) (p<0.001). Circumference of IP of the thumb was significantly thicker in males (6.4±0.5 cm) than in females (5.9±0.5 cm) (p<0.001). The circumferences of PIP of the index finger, middle finger, and ring finger were significantly thicker in males (6.2±0.4 cm, 6.2±0.4 cm, and 5.8±0.4 cm, respectively) than in females (5.6±0.4 cm, 5.7±0.4 cm, and 5.3±0.3 cm, respectively) (p<0.001).
The circumference of the wrist was significantly thicker in males (16.7±1.0 cm) than in females (15.1±1.1 cm) (p<0.001). The width of the palm was significantly larger in males (8.8±0.5 cm) than in females (8.1±0.5 cm) (p<0.001). For the ratio of palm length/palm width, there was no significant difference between males and females (1.2±0.1 cm) (p=0.996).
FFF of the middle finger was significantly greater in males (17.9±6.6 N) than in females (8.6±3.9 N) (p<0.001). FEF of the index finger and ring finger were significantly greater in males (8.5±2.0 N and 7.1±2.2 N, respectively) than in females (5.3±1.7 N and 4.7±.8 N, respectively) (p<0.001).
Maximal force of exertion on grasping (GF) of fingers (from index finger to little finger), index finger, middle finger, and ring finger were significantly greater in males (458.9±95.9 N, 135.5±40.3 N, 139.6±45.9 N, and 101.8±41.7 N, respectively) than in females (245.6±69.2 N, 85.4±26.1 N, 85.9±26.7 N, and 68.1±21.9 N, respectively) (p<0.001) (Table 2).
For area, both palm area (p=0.579) and HSA (p=0.882) showed no difference between age groups. For length, the middle finger (p=0.008) differed in age groups, and post-hoc verification showed that the length of the middle finger in the 20s (7.4±0.6) was significantly longer than in the 60s (6.7±0.9). The length of the thumb (p=0.408), index finger (p=0.182), ring finger (p=0.538), and palm (p=0.488), excluding the middle finger, did not differ significantly in age groups. The thickness of PIP of the ring finger (p=0.018) was also found to have a significant difference between each age group, but post-validation by a Scheffé test showed no significant difference in the group.
For widths, there was no statistically significant difference between the age groups for palm (p=0.620) and palm length/palm width (p=0.314).
The FFF of the middle finger (p=0.537), FEF of the index finger (p=0.690), and FEF of the ring finger (p=0.061) showed no significant difference between age groups. GF of all fingers (p<0.001) had significant differences between each age group. Post-hoc analysis showed that GF of all fingers in participants in their 20s (411.8±155.8) was significantly larger than GF of all fingers in their 50s (268.55±78.54). The GF of the index finger (p=0.003) was statistically significant between each age group. Post-hoc analysis confirmed that GF of the index finger in people in their 20s was significantly greater than the GF of the index finger (84.1±29.1) of participants in their 40s. The GF of the middle finger had a significant difference between each age group (p=0.008), but no group had a significant difference in post-hoc verification by a Scheffé test (Table 3).
For males, the FFF prediction model by the circumference of the PIP joint of the middle finger (p=0.007) and the maximum force of the grasping force of the middle finger (p<0.001) were statistically significant. The explanatory power of the FFF prediction model for circumference of the PIP joint of the middle finger of the prediction model was about 13%, and the explanatory power of the FFF prediction model for the maximum force of the grasping force of the middle finger was confirmed to be about 22%.
For females, FFF prediction models by all variables, except the FFF prediction model for the circumference of the PIP joint of the middle finger, appeared to be statistically significant. The explanatory power of the predictive model depends on the variables, but it is about 9% to 30%. For males, the FFF prediction models by palm area and width were not statistically significant. In females, the FFF prediction model by the circumference of the PIP joint of the middle finger was not statistically significant.
Although there was a slight difference in trends, in both males and females, the middle finger has the highest explanatory power of the FFF prediction model due to the maximum force applied. Both the non-standardized coefficients and the standardized coefficients were positive, and all independent variables had a defining effect on FFF. In males, the area and width of the palm did not affect FFF, and GF had the highest explanatory power (Table 4).
For males, the predictive model by all independent variables except GF of the index finger, among the variables used to predict FEF, was not statistically significant. The predictive model by GF of the index finger was statistically significant with p=0.042, and the explanatory power of the predictive model was about 8%.
For females, as opposed to males, only the predictive model by GF of the index finger (p=0.062) was not statistically significant. Palm area (p=0.030), circumference of IP of the thumb (p=0.001), the circumference of the PIP of the index finger (p=0.001), the circumference of the wrist (p<0.001), the length of the index finger (p=0.034), HSA (p=0.004), palm length (p=0.007), and all prediction models by palm width (p=0.003) were statistically significant. The explanatory power of these models was about 7% to 18%. Among the statistically significant models, only the length of the index finger in females had negative coefficients, indicating that the shorter the length of the index finger, the greater the FEF (Table 5).
For males, the FEF prediction model of the ring finger by all independent variables was statistically significant: palm area (p=0.001), circumference of the wrist (p=0.018), circumference of PIP of the ring finger (p=0.014), circumference of IP of the thumb (p=0.001), HSA (p=0.005), and palm width (p=0.027). The explanatory power of these predictive models was found to be about 7% to 18%, but the prediction model for palm length (p=0.058) was not significant.
The predictive model for the palm area showed the highest explanatory power of 18.2%, but the constant value was 0.062, which had a defining effect but not a significant impact. The influence of the model by the circumference of the IP of the thumb was 17.8%, and the constant value was 1.919, indicating that the degree of influence was relatively large.
For females, the predictive model was statistically significant for the HSA (p=0.021) and palm length (p=0.028), while palm area, the circumference of the wrist, the circumference of the PIP of the ring finger, the circumference of the IP of the thumb, and palm width were highly significant (p<0.001). The explanatory power of the model was also relatively low for HSA (8.1%) and palm length (7.4%), and the explanatory power of the predictive model for all other variables was relatively high, ranging from 24.1% to a maximum of 36.7% (Table 6).
An analysis of the linear correlation between FEF and circumference and length confirmed that circumference had a stronger linear correlation than length. Therefore, linear regression was performed to develop a model that can predict FEF by the circumference of each finger.
The model where the FEF of the index finger=2.7×circumference of the index finger–9.52 was statistically significant (p<0.001), and the explanatory power of the predictive model was 28.5%.
The model for predicting the FEF of the middle finger by the circumference of the middle finger (FEF of the middle finger=7.727×circumference of the middle finger–33.025) was statistically significant (p<0.001), and the explanatory power of the predictive model was 27.9%. A model for the ring finger (FEF of the ring finger=2.975×circumference of the index finger–10.738) was statistically significant (p<0.001), and the explanatory power of the predictive model was 36.8% (Table 7).

Discussion

For the mechanism of force-generating during finger striking, Hong et al. [5] stated that when one tries to flick a finger harder, greater tension is exerted on the extensor tendon. In this situation, volar-ward force is generated on the extensor tendon over the bony prominence of the metacarpal head. If the extensor tendon is well aligned with the sagittal band and the extensor hood, not much force can be applied to the sagittal band. However, when the extensor tendon slips to either the radial or the ulnar side, the force applied to the sagittal band when it slips to the radial or ulnar side will be mainly exerted on the opposite side of the sagittal band (Fig. 3).
The nasal bones are the most fragile facial bones, with tolerance levels for minimal fractures ranging from 111.21 to 333.62 N. The maxilla has a low tolerance level (622.75–1,979.46 N). The zygomatic arch is relatively fragile (tolerance level, 925.23–2,112.91 N), while the zygomatic body has a higher tolerance level (889.64–2,001.70 N) [6]. Among the facial bones, fractures occurred at 111.21 to 333.62 N for the nasal bone, 622.75 to 1,979.46 N for the maxilla, 925.23 to 2,112.91 N for the zygomatic arch, and 889.64 to 2,001.70 N for the zygomatic body. The sizes of FEF (index finger, 6.8±2.5 N; ring finger, 5.8±2.3 N) and FFF (middle finger, 12.9±7.0 N) in this study were not sufficient to cause facial bone fractures (Table 2). Although finger striking is usually applied on the forehead, it might strike the nose if the finger is slipped by mistake.
The four independent variables related to size in this study had the greatest effects, which can be interpreted as indicating that there are factors other than the area or width of the palm that determine the size of this force. However, considering that the explanatory power was not very high (20%–30%), the possibility that there is an independent variable that has a greater effect on FFF than the independent variables selected for this study cannot be ruled out (Table 4).
The explanatory power of the FEF of the ring finger prediction model using the circumference of the PIP of the ring finger was the highest at 36.7%, and the constant value was also 3.136, indicating the greatest degree of influence (Table 6). Differences in bone thickness and muscle mass can determine the circumference of each finger, which seems to affect the FEF (N) and GF (N) (Table 7).
According to Langer et al. [7], the force exerted by the hand and fingers to apply pressure to an object was measured using a grip force meter. Ramakrishnan et al. [8] stated that palm thickness and width are strongly correlated with grip strength for all wrist postures, whether dominant or not. According to Balogun et al. [9], flexion and extension of the wrist and forearm rotation have important effects on grip strength and interact with grip strength along with elbow posture. Fransson and Winkel [10] stated that grip strength is absolutely related to hand size. It turns out that females’ lower grip strength is due to their hands being smaller than those of males. According to Kim et al. [11], most of the muscles that make up the forearm are related to the movements of the wrist and fingers. In order to identify the correlation between the movement and the electromyographic signal generated through the motion of gripping the fingers, learning data that could simultaneously estimate the strength of the wrist and the grip strength were constructed [11].
When the index finger and ring finger were compared with the independent sample t-test, the FEF, girth, and grip force values of the index finger were statistically significantly greater than that of the ring finger. However, there was no significant difference in length between the index and ring fingers (Table 8).
According to Hong et al. [5], subluxation occurs most frequently in long fingers. However, comparing the index and ring fingers in this study, there was no difference in length, but the FEF, finger circumference, and grip strength were greater in the index finger. Therefore, the size of the FEF is more closely related to the finger circumference and grip strength than the finger length when taking the finger-striking posture.
Chauhan et al. [12] reviewed hand injuries according to zone and stated that zone V injury is a sagittal band rupture that may result from blunt trauma to the metacarpophalangeal (MCP) joint, a laceration or direct injury to the sagittal band, and resistance to extension or flexion across the MCP joint. This injury type is also referred to as “boxer’s knuckle” because these injuries frequently occur in athletes in direct contact (i.e., in boxing, soccer, and rugby).
ElMaraghy et al. [13] wrote that subluxation most often occurs in the middle finger. The middle finger has the anatomical features of a long radial sagittal band, a prominent metacarpal head, a rounded cross-section of the extensor tendon, increased distal extension of the sagittal band, and less substantial juncturae tendinum compared to the ring and little fingers.
Hong et al. [5] reported 26 cases of extensor tendon subluxation due to the finger striking posture. In all patients, the damaged area was the long finger, which was subluxed to the ulnar side, and slipping of the extensor tendon during finger striking frequently occurred on the long finger and ulnar side.
Beck et al. [14] reported that in two extensor tendon dislocation patients, the middle finger’s extensor tendon was exposed, and the fibers attached to the extensor hood were few, so the dislocation occurred most in the middle finger extensor tendon.
Young and Rayan [15] dissected to investigate the mechanism of sagittal band damage in the hands of 10 frozen cadavers and two fixed cadavers. The authors said that when the MCP is fully flexed during trauma, it is vulnerable to collateral ligament damage. When accompanied by wrist flexion, this force can be increased and the injury can be aggravated.
Rayan and Murray [16] classified sagittal band injuries into three types as follows: mild injuries without instability were classified as type I, moderate injuries with extensor tendon subluxation, type II, and severe injuries with tendon dislocation, type III.
Peelman et al. [17] treated 92 patients who complained of sagittal band incompetence by applying the following two types of splints: first, a “P-blocker splint” that is applied to the hand or forearm to prevent bending of the MCP; and second, a “sagittal band bridge splint” that restricts the bending of the MCP joint in the sphenoid region by hanging on both sides of the finger. The authors reported that splint therapy was very effective in acute sagittal band incompetence.
As a surgical method to reconstruct the ruptured sagittal band, there is a method of reattaching the superficial layer of the ruptured sagittal band to the outside of the extensor tendon5 by making a slip and loop with the accessory extensor tendon and fixing it in the middle of the extensor digitorum communis [14].
Kang et al. [18] recommended primary suture in case of acute dislocation of the extensor tendon, and for chronic cases, reconstruction using part of the soft tissue, accessory tendon, extensor tendon, etc. around the wound site was suggested.
This study has two limitations. First, the design did not account for the anatomic complexity of the index finger, specifically the independent extension capability mediated by the extensor indicis proprius muscle. This factor, along with finger circumference and grip strength, could influence the results. Second, a biomechanical limitation exists as the study did not measure the flexion angle at the MCP joint during the flicking motion (flick angle). The flick angle influences the force applied to the sagittal band upon slippage, potentially affecting the risk of extensor tendon subluxation. These limitations highlight the need for further studies that incorporate both anatomical considerations and the biomechanics of the flicking motion to obtain a more comprehensive understanding of extensor tendon subluxation.

Conclusion

As all characteristics increased, the FEF of the middle finger, the FFF of the index finger, and the FEF of the ring finger also tended to increase. It was confirmed that the index finger’s measurement average was linearly correlated with the index finger’s circumference (ρ=0.533), the middle finger’s measurement average was linearly correlated with the middle finger’s circumference (ρ=0.528), and the ring finger’s measurement average was linearly correlated with the ring finger’s circumference (ρ=0.60). The results of this study will help to understand the relationship between the forces generated in the process of finger flicking through the anatomical measurements of the hand.

Notes

The authors have nothing to disclose.

Funding

This work was supported by the Korean Military Medical Research Project funded by the ROK Ministry of National Defense (ROK-MND-2023-KMMRP-020).

References

1. Lopez-Ben R, Lee DH, Nicolodi DJ. Boxer knuckle (injury of the extensor hood with extensor tendon subluxation): diagnosis with dynamic US: report of three cases. Radiology. 2003; 228:642–6.
crossref
2. Elson RA. Dislocation of the extensor tendons of the hand: report of a case. J Bone Joint Surg Br. 1967; 49:324–6.
3. Catalano LW 3rd, Gupta S, Ragland R 3rd, Glickel SZ, Johnson C, Barron OA. Closed treatment of nonrheumatoid extensor tendon dislocations at the metacarpophalangeal joint. J Hand Surg Am. 2006; 31:242–5.
crossref
4. Ishizuki M. Traumatic and spontaneous dislocation of extensor tendon of the long finger. J Hand Surg Am. 1990; 15:967–72.
crossref
5. Hong IT, Oh CH, Sim YS, Han SH. Direct repair of the sagittal band for extensor tendon subluxation caused by finger flicking. Orthopade. 2017; 46:755–60.
crossref
6. Hwang K, Ma SH. A nasal bone fracture caused by a dog bite in an adult. J Craniofac Surg. 2021; 32:e630–2.
crossref
7. Langer D, Maeir A, Michailevich M, Luria S. Evaluating hand function in clients with trigger finger. Occup Ther Int. 2017; 2017:9539206.
crossref
8. Ramakrishnan B, Bronkema LA, Hallbeck MS. Effects of grip span, wrist position, hand and gender on grip strength. Proc Hum Factors Ergon Soc Annu Meet. 1994; 38:554–8.
crossref
9. Balogun JA, Akomolafe CT, Amusa LO. Grip strength: effects of testing posture and elbow position. Arch Phys Med Rehabil. 1991; 72:280–3.
10. Fransson C, Winkel J. Grip strength and leg design of power grip hand tools. J Biomech. 1989; 22:1012.
crossref
11. Kim YJ, Lee DH, Park H, Park JH, Bae JH, Baeg MH. Wrist and grasping forces estimation using electromyography for robotic prosthesis. J Korea Robot Soc. 2017; 12:206–16.
crossref
12. Chauhan A, Jacobs B, Andoga A, Baratz ME. Extensor tendon injuries in athletes. Sports Med Arthrosc Rev. 2014; 22:45–55.
crossref
13. ElMaraghy AW, Pennings A. Metacarpophalangeal joint extensor tendon subluxation: a reconstructive stabilization technique. J Hand Surg Am. 2013; 38:578–82.
crossref
14. Beck JD, Riehl JT, Klena JC. Anomalous tendon to the middle finger for sagittal band reconstruction: report of 2 cases. J Hand Surg Am. 2012; 37:1646–9.
crossref
15. Young CM, Rayan GM. The sagittal band: anatomic and biomechanical study. J Hand Surg Am. 2000; 25:1107–13.
crossref
16. Rayan GM, Murray D. Classification and treatment of closed sagittal band injuries. J Hand Surg Am. 1994; 19:590–4.
crossref
17. Peelman J, Markiewitz A, Kiefhaber T, Stern P. Splintage in the treatment of sagittal band incompetence and extensor tendon subluxation. J Hand Surg Eur Vol. 2015; 40:287–90.
crossref
18. Kang HJ, Yong SW, Shim DJ, Hahn SB, Kang ES. Dislocation of the extensor tendons at the level of the metacarpophalangeal joint. Arch Hand Microsurg. 2003; 8:148–52.

Fig. 1.
Measuring the force generated by flexion flicking of a middle finger (A) and the force generated during extension flicking of an index finger (B).
ahm-24-0007f1.tif
Fig. 2.
Measuring the maximal force of exertion on grasping for the index, middle, ring, and little fingers.
ahm-24-0007f2.tif
Fig. 3.
Forces generated during finger striking. , flexion angle of the metacarpophalangeal joint; Fe, the tensile force (blue arrow) exerted on the extensor tendon; Fsb, the force applied to the sagittal band when it slips to the radial or ulnar side.
ahm-24-0007f3.tif
Table 1.
Characteristics of participants in this study
Characteristic Data
No. of participants 120
Sex
 Male 55 (45.8)
 Female 65 (54.2)
Age (yr)
 20–29 34 (28.3)
 30–39 30 (25.0)
 40–49 10 (8.3)
 50–59 33 (27.5)
 60–69 13 (10.8)

Values are presented as number only or number (%).

Table 2.
Measured data according to sex
Measurement Area Sex
Total p-value
Male (n=55) Female (n=65)
Area (cm2) Palm 181.4±15.1 155.1±14.0 167.2±19.6 <0.001
HSA 87.4±11.3 70.0±9.0 78.0±13.3 <0.001
Length (cm) Thumb 5.6±0.4 5.1±0.5 5.3±0.5 <0.001
Index finger 6.9±0.6 6.4±0.5 6.7±0.6 <0.001
Middle finger 7.5±0.6 7.0±0.5 7.2±0.6 <0.001
Ring finger 7.0±0.5 6.5±0.5 6.7±0.6 <0.001
Palm 10.4±0.6 9.5±0.6 9.9±0.7 <0.001
Circumference (cm) IP of the thumb 6.4±0.5 5.9±0.5 6.1±0.5 <0.001
PIP of the index finger 6.2±0.4 5.6±0.4 5.9±0.5 <0.001
PIP of middle finger 6.2±0.4 5.7±0.4 5.9±0.5 <0.001
PIP of ring finger 5.8±0.4 5.3±0.3 5.6±0.5 <0.001
Wrist 16.7±1.0 15.1±1.1 15.8±1.3 <0.001
Width (cm) Palm 8.8±0.5 8.1±0.5 8.4±0.6 <0.001
Ratio Palm length/palm width 1.2±0.1 1.2±0.1 1.2±0.1 0.996
FFF (N) Middle finger 17.9±6.6 8.6±3.9 12.9±7.0 <0.001
FEF (N) Index finger 8.5±2.0 5.3±1.7 6.8±2.5 <0.001
Ring finger 7.1±2.2 4.7±1.8 5.8±2.3 <0.001
GF (N) Fingers (from index finger to little finger) 458.9±95.9 245.6±69.2 343.3±134.7 <0.001
Index finger 135.5±40.3 85.4±26.1 108.4±41.6 <0.001
Middle finger 139.6±45.9 85.9±26.7 110.5±45.4 <0.001
Ring finger 101.8±41.7 68.1±21.9 83.6±36.5 <0.001

Values are presented as mean±standard deviation.

HSA, hand surface area; IP, interphalangeal joint; PIP, proximal interphalangeal joint; FFF, force generated by striking with finger flexion; FEF, force generated during extension flicking; GF, maximal force of exertion on grasping.

Table 3.
Measured data according to age groups
Measurement Area Age group (yr)
p-value
Group 1 (20–29) Group 2 (30–39) Group 3 (40–49) Group 4 (50–59) Group 5 (60–69)
No. of subjects 34 30 10 33 13
Area (cm2) Palm 164.2±21.2 167.3±20.4 164.9±22.0 167.8±17.2 174.8±17.8 0.579
HSA 78.4±15.6 78.3±12.8 78.4±12.5 76.1±11.4 80.6±14.4 0.882
Length (cm) Thumb 5.4±0.5 5.4±0.5 5.2±0.4 5.3±0.5 5.1±0.8 0.408
Index finger 6.8±0.6 6.7±0.5 6.5±0.4 6.6±0.5 6.3±1.0 0.182
Middle finger 7.4±0.6 7.3±0.4 7.0±0.5 7.3±0.5 6.7±0.9 0.008a)
Ring finger 6.8±0.6 6.7±0.5 6.6±0.4 6.7±0.4 6.5±1.0 0.538
Palm 9.8±0.8 10±0.7 9.8±0.6 9.8±0.8 10.1±0.6 0.488
Circumference (cm) IP of the thumb 5.9±0.6 6.0±0.5 6.2±0.4 6.2±0.4 6.6±0.3 <0.001a,c)
PIP of index finger 5.8±0.6 5.7±0.5 5.8±0.4 5.9±0.4 6.2±0.3 0.091
PIP of middle finger 5.8±0.5 5.8±0.5 5.9±0.4 6.0±0.4 6.3±0.5 0.007a,c)
PIP of the ring finger 5.4±0.5 5.4±0.5 5.6±0.3 5.6±0.4 5.9±0.3 0.018
Wrist 15.9±1.7 15.5±1.2 15.7±1.1 15.8±1.2 16.5±0.8 0.250
Width (cm) Palm 8.4±0.7 8.4±0.6 8.5±0.6 8.4±0.5 8.6±0.6 0.620
Ratio Palm length/palm width 1.2±0.1 1.2±0.1 1.2±0.1 1.2±0.1 1.2±0.1 0.314
FFF (N) Middle finger 14.0±7.5 13.4±6.5 10.6±3.6 11.7±6.7 13.1±9.5 0.537
FEF (N) Index finger 6.7±2.8 6.8±2.6 6.6±1.8 6.5±2.4 7.7±2.1 0.690
Ring finger 5.2±2.6 5.6±1.9 5.7±1.8 6.0±2.4 7.4±1.8 0.061
GF (N) Fingers (from index finger to little finger) 411.8±155.8 372.3±135.1 288.5±61.9 292.5±104.2 268.6±78.5 <0.001a)
Index finger 124.8±39.8 118.8±52.3 84.1±29.1 96.3±31.0 90.7±27.3 0.003
Middle finger 127.8±47.3 120.1±58.6 92.5±20.9 97.7±32.5 89.5±23.4 0.008b)
Ring finger 95.3±42.2 86.4±42.1 68.1±23.6 77.9±30.5 72.9±17.5 0.115

Values are presented as number only or mean±standard deviation.

HSA, hand surface area; IP, interphalangeal joint; PIP, proximal interphalangeal joint; FFF, force generated by striking with finger flexion; FEF, force generated during extension flicking; GF, maximal force of exertion on grasping.

Significant difference a)between group 1 and group 5, b)between group 1 and group 3, and c)between group 2 and group 5.

Table 4.
FFF of the middle finger
Measurements Sex Constant SE β p-value
Palm area Male 0.054 0.059 0.125 0.016 0.362
Female 0.091 0.034 0.322 0.140 0.009
Circumference of PIP of the middle finger Male 5.241 1.879 0.358 0.128 0.007
Female 1.842 1.300 0.176 0.031 0.162
GF of the middle finger Male 0.067 0.017 0.468 0.219 <0.001
Female 0.081 0.016 0.551 0.303 <0.001
Palm width Male 0.718 1.893 0.052 0.003 0.706
Female 2.429 0.984 0.297 0.088 0.016

FFF, force generated by striking with finger flexion; PIP, proximal interphalangeal joint; GF, maximal force of exertion on grasping.

Table 5.
FEF of the index finger
Measurements Sex Constant SE β p-value
Palm area Male 0.004 0.019 0.030 0.001 0.826
Female 0.044 0.014 0.359 0.129 0.003
Circumference of IP of the middle finger Male –0.320 0.581 –0.075 0.006 0.584
Female 1.396 0.412 0.392 0.154 <0.001
Circumference of PIP of the index finger Male 0.154 0.710 0.030 0.001 0.829
Female 1.883 0.551 0.396 0.157 <0.001
Circumference of the wrist Male –0.093 0.273 –0.047 0.002 0.734
Female 0.686 0.183 0.428 0.183 <0.001
Length of the index finger Male 0.532 0.501 0.144 0.021 0.293
Female –0.881 0.407 –0.263 0.069 0.034
GF of the index finger Male 0.014 0.007 0.275 0.076 0.042
Female 0.015 0.008 0.233 0.054 0.062
HSA Male –0.001 0.025 –0.004 0.000 0.975
Female 0.068 0.022 0.356 0.127 0.004
Palm length Male –0.324 0.491 –0.090 0.008 0.512
Female 0.927 0.334 0.330 0.109 0.007
Palm width Male –0.437 0.588 –0.102 0.010 0.460
Female 1.311 0.418 0.367 0.135 0.003

FEF, force generated during extension flicking; IP, interphalangeal joint; PIP, proximal interphalangeal joint; GF, maximal force of exertion on grasping, HSA, hand surface area.

Table 6.
FEF of the ring finger
Measurements Sex Constant SE β p-value
Palm area Male 0.062 0.018 0.426 0.182 <0.001
Female 0.063 0.014 0.490 0.241 <0.001
Circumference of IP of the middle finger Male 1.919 0.567 0.421 0.178 <0.001
Female 2.162 0.380 0.582 0.339 <0.001
Circumference of PIP of the ring finger Male 1.631 0.639 0.331 0.109 0.014
Female 3.136 0.519 0.606 0.367 <0.001
Circumference of the wrist Male 0.678 0.278 0.318 0.101 0.018
Female 0.915 0.177 0.547 0.299 <0.001
HSA Male 0.074 0.025 0.377 0.142 0.005
Female 0.057 0.024 0.285 0.081 0.021
Palm length Male 0.991 0.512 0.257 0.066 0.058
Female 0.800 0.356 0.273 0.074 0.028
Palm width Male 1.379 0.606 0.298 0.089 0.027
Female 1.895 0.404 0.509 0.259 <0.001

FEF, force generated during extension flicking; IP, interphalangeal joint; PIP, proximal interphalangeal joint; HSA, hand surface area.

Table 7.
Linear regression model
FEF Sex Constant SE β p-value
Index finger Male 0.062 0.018 0.426 0.182 <0.001
Female 0.063 0.014 0.490 0.241 <0.001
Middle finger Male 1.919 0.567 0.421 0.178 <0.001
Female 2.162 0.380 0.582 0.339 <0.001
Ring finger Male 1.631 0.639 0.331 0.109 0.014
Female 3.136 0.519 0.606 0.367 <0.001

FEF, force generated during extension flicking.

Table 8.
Comparison of the index and ring fingers
Measurement Index finger Ring finger p-value
Length (cm) 6.7±0.6 6.7±0.6 0.346
Circumference (cm) 5.9±0.5 5.6±0.5 <0.001
FEF (N) 6.8±2.5 5.8±2.3 0.002
GF (N) 108.4±41.6 83.6±36.5 <0.001

FEF, force generated during extension flicking; GF, maximal force of exertion on grasping.

≒, no significant difference (p>0.05); < or >, significant difference (p<0.05).

TOOLS
Similar articles