Abstract
Objective
This study aimed to assess the effects of commonly consumed hot drinks on the force decay of orthodontic elastomeric chains.
Methods
This in vitro experimental study evaluated 375 pieces of elastomeric chains with six rings placed on a jig. Four rings were stretched by 23.5 mm corresponding to the approximate distance between the canine and the second premolar. Fifteen pieces served as reference samples at time zero, and 360 pieces were randomized into four groups control, hot water, hot tea, and hot coffee. Each group was further divided into six subgroups (n = 15) according to the different exposure periods. The specimens in the experimental groups were exposed to the respective solutions at 65.5°C four times per day for 90 seconds at 5-second intervals. The control group was exposed to artificial saliva at 37°C. The force decay of the samples was measured at 1, 2, 7, 14, 21, and 28 days using a universal testing machine. Data were analyzed using repeated-measures analysis of variance.
Results
Maximum force decay occurred on day 1 in all groups. The minimum force was recorded in the control group, followed by the tea, coffee, and hot water groups on day 1. At the other time points, the minimum force was observed in the tea group, followed by the control, coffee, and hot water groups.
Many orthodontic patients require space closure, and several tools, including closing loops, coil springs, elastics, and elastomeric chains, are available for this purpose. Elastomeric chains have been used in orthodontic treatment since 1960. These amorphous polyurethane polymers have extensively replaced latex elastics for orthodontic tooth movement.1-3 Elastomeric chains are user-friendly, time-saving, versatile, and are available in various colors and lengths. These are widely used for different types of tooth movements, such as space closure and correction of dental midline deviation, rotation, retraction, and protraction.4-6 Short chair time, minimal patient cooperation, optimal biocompatibility, ease of use, high flexibility, and low cost are among the advantages of orthodontic elastomeric chains. However, they also have shortcomings, such as the enhancement of biofilm retention and subsequent enamel demineralization, dental caries, and gingival inflammation.7,8
Force decay is an important undesirable property of elastomeric chains, which indicates the need for their replacement, necessitating dental visits.9 Knowledge of force decay and appropriate time for replacement of elastomeric chains is imperative, considering the preference of light continuous forces in orthodontics due to biological and mechanical considerations. However, predicting the force decay and stability of elastomeric chains is difficult.3 Evidence shows that elastomeric chains naturally experience force decay because of their viscoelastic properties, wherein a considerably high force decay occurs on the first day after the placement of the elastomeric chains. Factors, such as time, color, the structure of the chain (closed/open), prestretching, the magnitude of stretching, oral environment, saliva, enzymes, pH alterations, exposure to different agents, foods, or mouthwashes, and physical activities, such as mastication and tooth brushing, can affect the force decay of elastomeric chains.5,10-16 Ideally, reduction of the chain force should occur gradually over time, causing greater tooth movement and decreasing the required frequency of dental visits.
Thermal stress is another factor to consider with respect to its effects on elastomeric chains. The consumption of tea and coffee is highly popular in many countries worldwide, and some patients frequently consume these as hot drinks daily. These thermal stresses may affect force degradation of orthodontic elastomeric chains.17,18 A previous study reported that elastomeric chains subjected to thermal cycles experienced force decay less than chains stored at 37°C.1
Evidence has shown that materials with different chemical compositions have different effects on the force degradation of orthodontic elastomeric chains.5,9,13 Accordingly, different drinks may have different effects on the force decay of the chains. Thus, if a particular food or drink adversely affects the force decay of elastomeric chains, clinicians may need to request patients to limit their consumption, especially in the first few days after the activation of the chains. Therefore, this study aimed to assess the effect of commonly consumed hot drinks on the force decay of orthodontic elastomeric chains.
This in vitro, experimental study evaluated 375 pieces of silver closed elastomeric chains with six rings (American Orthodontics, Sheboygan, WI, USA). Twenty-four Teflon jigs containing 15 pairs of stainless-steel rods were also used. Each rod was placed 23.5 mm from its corresponding rod to simulate the approximate distance between the canine and second premolars in patients with extracted first premolars. Each pair of rods was placed 5–7 mm from the adjacent pair (Figure 1). The terminal rings of the chains were free, and the chains were stretched by 23.5 mm from the second to the fifth rings. Fifteen specimens were placed in each jig. All chains were prestretched to twice their length prior to placement on the jig. Of the 375 specimens, 15 were used as reference samples (before exposure and at time zero) and 360 were randomly divided into the following groups:
Group 1: exposure to 65.5°C (150°F) hot water
Group 2: exposure to 65.5°C (150°F) hot tea
Group 3: exposure to 65.5°C (150°F) hot coffee
Group 4 (control): exposure to artificial saliva at 37°C
All specimens were stored in artificial saliva at 37°C in an incubator (Memmert GmbH, Schwabach, Germany). The artificial saliva was composed of 1.5 mM CaCl2, 0.9 mM NaH2PO4, and 0.15 M KCl, at a pH of 7.
Groups 1 to 3 were exposed to the respective hot drinks four times a day, each time for 90 seconds at 5-second intervals, to simulate thermal stresses applied to the elastomeric chains when drinking tea, coffee, or hot water. The temperature of the drinks was regularly checked using a thermometer. The artificial saliva was refreshed twice a week.
Each group was then randomized into six subgroups (n = 15) for exposure times measured at 1, 2, 7, 14, 21, and 28 days. The remaining 15 pieces served as the pre-exposure reference samples at time zero. After completion of the respective exposure periods, the forces of all specimens were measured using a universal testing machine (Zwickroell, Ulm, Germany).
Changes in the force magnitude of the chains were analyzed and compared using repeated-measures analysis of variance (ANOVA) using the PASS software (NCSS LLC, Kaysville, UT, USA), considering the type of drink as a between-subject factor. Statistical significance was set at P < 0.05. Tukey HSD post hoc test was used for pairwise comparison.
The study was approved by the ethical committee of the Tehran University of Medical Sciences (no. IR.TUMS.DENTISTRY.REC.1399.125). The informed consent was waived.
The mean initial force value at T0 was 5.73 ± 0.20 N. Table 1 and Figure 2 present the mean force values in the four groups at other time points. The results showed significant effects of time and type of drink and their interaction on force decay (P < 0.001). ANOVA showed that at all time points, except on day 7 (P = 0.092), a significant difference was noted in the force decay of elastomeric chains exposed to the different drinks (P < 0.05).
The largest amount of differential force decay occurred on day 1 (4.65 N, 81.06%). The averaged force decay (%) of four groups on days 2, 7, 14, 21, and 28 was 84.09%, 84.41%, 84.86%, 85.81%, and 86.01%, respectively.
Table 2 presents pairwise comparisons of the groups at different time points. On day 1, the order of the mean force from the largest to the smallest was as follows: hot water (1.29 ± 0.08 N), coffee (1.09 ± 0.09 N), tea (1.04 ± 0.10 N), and control (0.92 ± 0.09 N). The control and hot water groups exhibited significant differences from the other groups (P < 0.05). The tea and coffee groups were not significantly different (P = 0.39). From day 2 to the end of the study period, the order of the mean force from the largest to the smallest was as follows: hot water, coffee, control, and tea. On day 2, the force in the tea group was significantly lower than that in the coffee and hot water groups (P < 0.05). The control group showed no significant differences from the other groups (P > 0.05). The hot water and coffee groups were not significantly different either (P > 0.05). On day 7, no significant differences were observed between groups. On days 14 and 21, only the difference between the tea and hot water groups was significant, such that the mean force was significantly lower in the tea group (P < 0.05). On day 28, the tea group had a significantly lower force than the coffee and hot water groups, and the control group had a significantly lower force than the hot water group (P < 0.05).
Table 3 compares the force decays at different time points within each group. In all groups, the force gradually decreased from day 0 to 28, and the maximum force decay occurred on day 1.
In the artificial saliva group, the force on day 0 was significantly higher than that at all other time points (P < 0.05). Additionally, in the artificial saliva group, the force on day 1 was significantly greater than that on days 21 and 28 (P < 0.05). No other significant differences were observed within the artificial saliva group with respect to time (P > 0.05).
In the tea and coffee groups, the force on day 0 was significantly higher than those at the other time points (P < 0.05). In addition, the force on day 1 was significantly higher than that at the other time points (P < 0.05). No significant differences were noted at the other time points (P > 0.05).
In the hot water group, the force was significantly higher on day 0 than at the other time points (P < 0.05). Furthermore, the force on day 1 was significantly greater than those at the other time points (P < 0.05). The force on day 2 was significantly lower than that on days 0 and 1 and significantly higher than those on days 21 and 28 (P < 0.05). No other significant differences in force decay of other time points were observed in the hot water group (P > 0.05).
Force decay is one of the most unfavorable properties of orthodontic elastomeric chains. There are concerns regarding the effect of frequent consumption of hot drinks on the force decay of elastomeric chains. Therefore, this study assessed the effect of commonly consumed hot drinks on the force decay of elastomeric chains.
The present study confirmed the significant effects of temperature and type of drink on the force degradation of elastomeric chains. Considering the impact of heat on most physical and chemical reactions, its effect on the force decay of the chains was in close accordance with expectations. Evidence has shown that different mouthwashes have different effects on the force decay of chains owing to their different compositions; this was also true for different drinks. Therefore, the differences in force decay caused by the different drinks may be attributed to the different ingredients in tea and coffee (caffeine). Differences in the pH of drinks can also affect force decay.
In this study, the effect of hot drinks on the force decay of chains was evaluated over a 28-day period, which was selected because orthodontic visits to replace the chains are often scheduled every 28 days. Nonetheless, the results showed that the majority of the force decay occurred within the first 24 hours (81.06%), which is consistent with the literature. Therefore, the time point of 1 day was clinically more important than the other time points. In addition, it is much more practical and easier to request patients to watch their diet and refrain from the consumption of certain foods or drinks for the first 24 to 48 hours compared with longer periods of time. From the clinical standpoint, a noteworthy issue is that chains are often used several times during the course of orthodontic treatment in order to close the entire space. Thus, the clinical significance of the force decay difference among drinks becomes more prominent when considering the frequency of chain use. According to the results, patients can consume hot drinks during space closure by chains with no concern about possible adverse effects, as they may even have a positive effect. In addition, it would be preferable for patients to drink hot water instead of tea or coffee within the first 24 hours; however, there were no detrimental effects observed when drinking coffee or tea, compared with the control group. Coffee consumption is preferable to tea consumption on day 2, which may be explained by the pH or compositional differences between coffee and tea; however, the effect size is very small and the difference may be clinically irrelevant. One strength of the present study was the attempt to simulate the consumption of hot drinks in a clinical setting by using 5-second intervals for exposure to drinks instead of immersing the specimens in hot drinks for 30 seconds. The results showed the highest residual force in the hot water group, followed by the coffee, tea, and control groups on day 1. On days 2 to 28, the highest residual force was observed in the hot water group, followed by the coffee, control, and tea groups. Considering the difference in the order of force when comparing day 1 with other time points, the tests were repeated again on day 1 to ensure accuracy, and the same results were obtained.
Several studies have evaluated the elastomeric chain force decay at different time points using various solutions,1,5,7,9,12-14,17,19,20 commercial brands,1,11,12,14,19 and temperatures.1,17,18 Braga et al.17 evaluated the elastomeric chain force decay following exposure to hot water, green tea, and coffee. In contrast to the present findings, they showed maximum force decay in the first 7 days in the hot water group, whereas the maximum force decay was noted in the tea group in the present study. In addition, they found a significant difference between the groups on day 7, which was not observed in the present findings. These differences may be due to the use of green tea in their study versus black tea in the present study, as well as different methodologies. The samples in that study were immersed in the solutions (twice daily for 30 seconds each), which is different from our methodology. In addition, they did not assess the force decay on day 1 and 28, and they evaluated drinks at 70°C versus 65.5°C in the present study.
Sulaiman et al.18 evaluated the effects of temperature and artificial saliva on the tensile force of elastomeric chains. The samples were evaluated at 4°C, 23°C, 37°C, and 55°C, by immersing the chains in the solution for 210 minutes. They reported a minimum force decay at 4°C and a maximum reduction at 55°C in both artificial saliva and aquadest groups. Nachan et al.12 studied the effects of black tea, milk, cola, fluoride mouthwash, and artificial saliva on the force degradation of the Ormco Power Chaib, 3M Unitek Alastik chain, and American Orthodontics of short and long types. The results showed different force degradation rates for different products in different types of solutions. Weissheimer et al.11 evaluated the force decay of different brands of elastomeric chains: American Orthodontics, Morelli, Ormco, and TP Orthodontics. The force was measured at 1, 3, 5, 7, 9, and 2 hours; and at 7, 14, 21, 28, and 35 days. The results revealed a maximum force decay on day 1, in line with the present findings. Ramachandraiah et al.14 assessed the effects of mouthwashes (Listerine, Wokadine, 21.6% alcohol, and 8.38% alcohol) on the force decay of 3M Unitek, Ortho Plus, and Ortho Organizer orthodontic chains. In line with the present findings, the maximum force decay was noted on day 1 (39.45–58.35%). In general, the non-prestretched elastomeric chains experienced greater force decay than the pre-stretched samples did. Based on the results obtained by Ramachandraiah et al.,14 prestretched chains were used in this study. Brand selection was based on brand availability and reputation.
Despite attempts to simulate the clinical setting as closely as possible, this study used an in vitro design that has limitations related to the absence of microbial flora, functional forces, diet, oral habits, and other biological conditions. Therefore, in vivo studies and clinical trials are required to obtain reliable results. Further investigations are recommended on the effects of commonly consumed cold drinks, such as milk and fruit juices, on the elastomeric chain force decay.
Although high variability existed among the different hot drinks at different time points with regard to force decay, the maximum force decay occurred in the first 24 to 48 hours. It appears that after 48 hours, the use or absence of hot drinks did not cause a clinically significant change in the force decay of elastomeric chains. According to the present results, it may not be necessary to refrain from the consumption of hot drinks during space closure by elastomeric chains.
ACKNOWLEDGEMENTS
The authors would like to express their gratitude to the Deputy of Research of Tehran University of Medical Sciences for their support.
Notes
REFERENCES
1. De Genova DC, McInnes-Ledoux P, Weinberg R, Shaye R. 1985; Force degradation of orthodontic elastomeric chains--a product comparison study. Am J Orthod. 87:377–84. https://doi.org/10.1016/0002-9416(85)90197-6. DOI: 10.1016/0002-9416(85)90197-6. PMID: 3857862.
2. Evans KS, Wood CM, Moffitt AH, Colgan JA, Holman JK, Marshall SD, et al. 2017; Sixteen-week analysis of unaltered elastomeric chain relating in-vitro force degradation with in-vivo extraction space tooth movement. Am J Orthod Dentofacial Orthop. 151:727–34. https://doi.org/10.1016/j.ajodo.2016.10.020. DOI: 10.1016/j.ajodo.2016.10.020. PMID: 28364896.
3. Oshagh M, Ajami S. 2010; A comparison of force decay: elastic chain or tie-back method? World J Orthod. 11:e45–51. https://pubmed.ncbi.nlm.nih.gov/21490987/. PMID: 21490987.
4. Halimi A, Benyahia H, Doukkali A, Azeroual MF, Zaoui F. 2012; A systematic review of force decay in orthodontic elastomeric power chains. Int Orthod. 10:223–40. https://doi.org/10.1016/j.ortho.2012.06.013. DOI: 10.1016/j.ortho.2012.06.013. PMID: 22906378.
5. Javanmardi Z, Salehi P. 2016; Effects of Orthokin, Sensikin and Persica mouth rinses on the force degradation of elastic chains and NiTi coil springs. J Dent Res Dent Clin Dent Prospects. 10:99–105. https://doi.org/10.15171/joddd.2016.016. DOI: 10.15171/joddd.2016.016. PMID: 27429726. PMCID: PMC4946005. PMID: 95b4eac0de044b1bb463eb414c1f959b.
6. Masoud AI, Tsay TP, BeGole E, Bedran-Russo AK. 2014; Force decay evaluation of thermoplastic and thermoset elastomeric chains: a mechanical design comparison. Angle Orthod. 84:1026–33. https://doi.org/10.2319/010814-28.1. DOI: 10.2319/010814-28.1. PMID: 24784844. PMCID: PMC8638502.
7. Behnaz M, Dalaie K, Hosseinpour S, Namvar F, Kazemi L. 2017; The effect of toothpastes with bleaching agents on the force decay of elastomeric orthodontic chains. Eur J Dent. 11:427–31. https://doi.org/10.4103/ejd.ejd_83_17. DOI: 10.4103/ejd.ejd_83_17. PMID: 29279666. PMCID: PMC5727725.
8. Menon VV, Madhavan S, Chacko T, Gopalakrishnan S, Jacob J, Parayancode A. 2019; Comparative assessment of force decay of the elastomeric chain with the use of various mouth rinses in simulated oral environment: an in vitro study. J Pharm Bioallied Sci. 11(Suppl 2):S269–73. https://doi.org/10.4103/JPBS.JPBS_9_19. DOI: 10.4103/JPBS.JPBS_9_19. PMID: 31198351. PMCID: PMC6555337. PMID: de4ac7aeacc64ca1944e68758045c9de.
9. Pithon MM, Rodrigues AC, Sousa EL, Santos LP, Soares Ndos S. 2013; Do mouthwashes with and without bleaching agents degrade the force of elastomeric chains? Angle Orthod. 83:712–7. https://doi.org/10.2319/081012-646.1. DOI: 10.2319/081012-646.1. PMID: 23311601. PMCID: PMC8754043.
10. Baty DL, Volz JE, von Fraunhofer JA. 1994; Force delivery properties of colored elastomeric modules. Am J Orthod Dentofacial Orthop. 106:40–6. https://doi.org/10.1016/S0889-5406(94)70019-2. DOI: 10.1016/S0889-5406(94)70019-2. PMID: 8017348.
11. Weissheimer A, Locks A, de Menezes LM, Borgatto AF, Derech CD. 2013; In vitro evaluation of force degradation of elastomeric chains used in orthodontics. Dental Press J Orthod. 18:55–62. https://doi.org/10.1590/s2176-94512013000100014. DOI: 10.1590/S2176-94512013000100014. PMID: 23876950.
12. Nachan R, Kalia A, Al-Shahrani I. 2015; Force degradation of orthodontic elastomeric chain due to commonly consumed liquids: an in vitro study. World J Dent. 6:31–8. https://doi.org/10.5005/jp-journals-10015-1309. DOI: 10.5005/jp-journals-10015-1309.
13. Kumar K, Shetty S, Krithika MJ, Cyriac B. 2014; Effect of commonly used beverage, soft drink, and mouthwash on force delivered by elastomeric chain: a comparative in vitro study. J Int Oral Health. 6:7–10. https://pubmed.ncbi.nlm.nih.gov/25083025/. PMID: 25083025. PMCID: PMC4109247.
14. Ramachandraiah S, Sridharan K, Nishad A, Manjusha KK, Abraham EA, Ramees MM. 2017; Force decay characteristics of commonly used elastomeric chains on exposure to various mouth rinses with different alcohol concentration: an in vitro study. J Contemp Dent Pract. 18:813–20. https://pubmed.ncbi.nlm.nih.gov/28874647/. DOI: 10.5005/jp-journals-10024-2132.
15. Teixeira L, Pereira Bdo R, Bortoly TG, Brancher JA, Tanaka OM, Guariza-Filho O. 2008; The environmental influence of Light Coke, phosphoric acid, and citric acid on elastomeric chains. J Contemp Dent Pract. 9:17–24. https://doi.org/10.5005/jcdp-9-7-17. DOI: 10.5005/jcdp-9-7-17. PMID: 18997912.
16. Oshagh M, Khajeh F, Heidari S, Torkan S, Fattahi HR. 2015; The effect of different environmental factors on force degradation of three common systems of orthodontic space closure. Dent Res J (Isfahan). 12:50–6. https://doi.org/10.4103/1735-3327.150331. DOI: 10.4103/1735-3327.150331. PMID: 25709675. PMCID: PMC4336972. PMID: 1ce2c94056f54876bb4d4c1995ae5f05.
17. Braga E, Souza G, Barretto P, Ferraz C, Pithon M. 2019; Experimental evaluation of strength degradation of orthodontic chain elastics immersed in hot beverages. J Indian Orthod Soc. 53:244–8. https://doi.org/10.1177/0301574219867540. DOI: 10.1177/0301574219867540.
18. Sulaiman TH, Eriwati YK, Indrani D. 2018; Effect of temperature on tensile force of orthodontics power chain in artificial saliva solution. J Phys Conf Ser. 1073:062006. https://doi.org/10.1088/1742-6596/1073/6/062006. DOI: 10.1088/1742-6596/1073/6/062006.
19. Kassir CA, Daou M, Abboud M. 2020; Comparison of the force decay over time of four different brands of elastomeric chains (elongated to 25mm grey/transparent and closed/open): an in-vitro study. Int Orthod. 18:538–45. https://doi.org/10.1016/j.ortho.2020.05.003. DOI: 10.1016/j.ortho.2020.05.003. PMID: 32536451.
20. Omidkhoda M, Rashed R, Khodarahmi N. 2015; Evaluation of the effects of three different mouthwashes on the force decay of orthodontic chains. Dent Res J (Isfahan). 12:348–52. https://doi.org/10.4103/1735-3327.161453. DOI: 10.4103/1735-3327.161453. PMID: 26288625. PMCID: PMC4533193. PMID: 3eb098a1223148e9969488d314d59ec0.
Table 1
Day | Group |
Mean force (N) |
Force decay (N) |
Force decay (%) |
Standard deviation (N) | % at time 0 | Tea | Coffee | Hot water |
---|---|---|---|---|---|---|---|---|---|
1 | Control | 0.92 | 4.81 | 83.92 | 0.09 | 16.07 | 0.01* |
< 0.001*** 0.39 |
< 0.001*** < 0.001*** < 0.001*** |
Tea | 1.04 | 4.69 | 81.88 | 0.10 | 18.11 | ||||
Coffee | 1.09 | 4.64 | 80.97 | 0.09 | 19.02 | ||||
Hot water | 1.29 | 4.44 | 77.43 | 0.08 | 22.56 | ||||
2 | Control | 0.90 | 4.83 | 84.25 | 0.06 | 15.74 | 0.19 |
0.82 0.03* |
0.05 < 0.001*** 0.31 |
Tea | 0.85 | 4.88 | 85.11 | 0.05 | 14.88 | ||||
Coffee | 0.92 | 4.81 | 83.87 | 0.08 | 16.12 | ||||
Hot water | 0.97 | 4.76 | 83.13 | 0.07 | 16.86 | ||||
7 | Control | 0.90 | 4.83 | 84.38 | 0.09 | 15.61 | 0.46 |
> 0.999 0.37 |
0.69 0.06 0.78 |
Tea | 0.84 | 4.89 | 85.32 | 0.09 | 14.67 | ||||
Coffee | 0.90 | 4.83 | 84.27 | 0.12 | 15.72 | ||||
Hot water | 0.94 | 4.79 | 83.66 | 0.10 | 16.32 | ||||
14 | Control | 0.85 | 4.88 | 85.08 | 0.08 | 14.91 | 0.88 |
0.89 0.47 |
0.19 0.04* 0.56 |
Tea | 0.84 | 4.89 | 85.42 | 0.08 | 14.57 | ||||
Coffee | 0.87 | 4.86 | 84.76 | 0.07 | 15.23 | ||||
Hot water | 0.91 | 4.82 | 84.17 | 0.06 | 15.82 | ||||
21 | Control | 0.80 | 4.93 | 86.02 | 0.06 | 13.97 | 0.79 |
0.76 0.24 |
0.24 0.03* 0.79 |
Tea | 0.78 | 4.95 | 86.40 | 0.07 | 13.59 | ||||
Coffee | 0.82 | 4.91 | 85.61 | 0.06 | 14.38 | ||||
Hot water | 0.85 | 4.88 | 85.22 | 0.06 | 14.77 | ||||
28 | Control | 0.80 | 4.93 | 86.12 | 0.03 | 13.87 | 0.18 |
0.45 < 0.01** |
0.04* < 0.001*** 0.59 |
Tea | 0.77 | 4.96 | 86.54 | 0.03 | 13.45 | ||||
Coffee | 0.81 | 4.92 | 85.82 | 0.03 | 14.17 | ||||
Hot water | 0.83 | 4.90 | 85.56 | 0.04 | 14.43 |
Table 2
Day | Group | P value | |
---|---|---|---|
1 | Control | Tea | 0.01* |
Coffee | < 0.001*** | ||
Hot water | < 0.001*** | ||
Tea | Hot water | < 0.001*** | |
Coffee | 0.39 | ||
Coffee | Hot water | < 0.001*** | |
2 | Control | Tea | 0.19 |
Coffee | 0.82 | ||
Hot water | 0.05 | ||
Tea | Hot water | < 0.001*** | |
Coffee | 0.03* | ||
Coffee | Hot water | 0.31 | |
7 | Control | Tea | 0.46 |
Coffee | > 0.999 | ||
Hot water | 0.69 | ||
Tea | Hot water | 0.06 | |
Coffee | 0.37 | ||
Coffee | Hot water | 0.78 | |
14 | Control | Tea | 0.88 |
Coffee | 0.89 | ||
Hot water | 0.19 | ||
Tea | Hot water | 0.04* | |
Coffee | 0.47 | ||
Coffee | Hot water | 0.56 | |
21 | Control | Tea | 0.79 |
Coffee | 0.76 | ||
Hot water | 0.24 | ||
Tea | Hot water | 0.03* | |
Coffee | 0.24 | ||
Coffee | Hot water | 0.79 | |
28 | Control | Tea | 0.18 |
Coffee | 0.45 | ||
Hot water | 0.04* | ||
Tea | Hot water | < 0.001*** | |
Coffee | < 0.01** | ||
Coffee | Hot water | 0.59 |
Table 3
Day | Type of beverage | ||||
---|---|---|---|---|---|
Control | Tea | Coffee | Hot water | ||
1 | 2 | > 0.999 | < 0.001*** | 0.001** | < 0.001*** |
7 | 0.99 | < 0.001*** | < 0.001*** | < 0.001*** | |
14 | 0.53 | < 0.001*** | < 0.001*** | < 0.001*** | |
21 | 0.02* | < 0.001*** | < 0.001*** | < 0.001*** | |
28 | 0.01* | < 0.001*** | < 0.001*** | < 0.001*** | |
2 | 7 | > 0.999 | > 0.999 | 1.00 | 0.98 |
14 | 0.84 | 1.00 | 0.85 | 0.65 | |
21 | 0.09 | 0.41 | 0.15 | 0.02* | |
28 | 0.06 | 0.29 | 0.07 | < 0.01** | |
7 | 14 | 0.92 | > 0.999 | 0.99 | 0.99 |
21 | 0.14 | 0.62 | 0.43 | 0.18 | |
28 | 0.10 | 0.48 | 0.26 | 0.05 | |
14 | 21 | 0.76 | 0.73 | 0.87 | 0.63 |
28 | 0.66 | 0.59 | 0.70 | 0.30 | |
21 | 28 | > 0.999 | > 0.999 | > 0.999 | > 0.999 |