Background

Ramped positioning is recommended for intubating obese patients undergoing direct laryngoscopy. However, whether the use of the ramped position can provide any benefit in videolaryngoscopy-guided intubation remains unclear. This study assessed intubation time using videolaryngoscopy in morbidly obese patients in the ramped versus sniffing positions.

Methods

This is a prospective randomized study in patients with morbid obesity (n = 82; body mass index [BMI] ≥ 35 kg/m2). Patients were randomly allocated to either the ramped or the standard sniffing position groups. During the induction of general anesthesia, difficulty in mask ventilation was assessed using the Warters scale. Tracheal intubation was performed using a C-MAC® D-Blade videolaryngoscope, and intubation difficulty was assessed using the intubation difficulty scale (IDS). The primary endpoint was the total intubation time calculated as the sum of the laryngoscopy and tube insertion times.

Results

The percentage of difficult mask ventilation (Warters scale ≥ 4) was significantly lower in the ramped (n = 40) than in the sniffing group (n = 41) (2.5% vs. 34.1%, P < 0.001). The percentage of easy intubation (IDS = 0) was significantly higher in the ramped than in the sniffing group (70.0% vs. 7.3%, P < 0.001). The total intubation time was significantly shorter in the ramped than in the sniffing group (22.5 ± 6.2 vs. 40.9 ± 9.0, P < 0.001).

Conclusions

Compared with the sniffing position, the ramped position reduced intubation time in morbidly obese patients and effectively facilitated both mask ventilation and tracheal intubation using videolaryngoscopy.

Introduction

With the worldwide increase in the prevalence of obesity, anesthesiologists are encountering an increasing number of obese patients in the operating room [1,2]. Although increased body mass index (BMI) itself poorly predicts difficult laryngoscopy [35], obese patients tend to have other predictors of difficult intubation, such as a large neck circumference [6,7]. Many studies have reported that laryngoscopy and tracheal intubation are more difficult to perform in obese patients than in lean patients [3,8,9].
For successful intubation under direct laryngoscopy, appropriate positioning is increasingly emphasized in obese patients [10,11]. Collins et al. [12] suggested placing morbidly obese patients in a ramped position rather than in the standard sniffing position. The ramped position is achieved by arranging blankets under the patient’s upper body and head to obtain a horizontal alignment between the external auditory meatus and sternal notch [13]. This position produces proper alignment of the oral, pharyngeal, and laryngeal axes (the three axes of intubation) in obese patients, similar to the sniffing position in lean patients. Subsequent studies have demonstrated that the ramped position significantly improved the laryngeal view in morbidly obese patients during direct laryngoscopy [1416].
Videolaryngoscopy is another useful option for tracheal intubation in obese patients. A recent meta-analysis of 13 randomized controlled trials showed that videolaryngoscopy was superior to direct laryngoscopy in terms of intubation success rate, intubation time, and glottic visualization in obese patients [17]. Only four of these 13 trials described the use of the ramped position for intubation, while the others did not describe patient positioning or did not use the ramped position. Unlike direct laryngoscopy, videolaryngoscopy does not require eye alignment with the three axes of intubation to visualize the glottis and facilitate tracheal intubation [18]. Considering this advantage, it seems possible that the implementation of videolaryngoscopy could lead to successful intubation in obese patients, even without the use of the ramped position.
However, it remains unclear whether the use of the ramped position confers any benefit to videolaryngoscopy-guided intubation in obese patients. Therefore, this study was conducted to compare videolaryngoscopy-guided intubation of morbidly obese patients in the ramped versus sniffing position. The hypothesis of the study was that the intubation time in the ramped position might be shorter than that in the sniffing position. The primary outcome was intubation time (the time required for successful intubation); the secondary outcomes were difficulties in mask ventilation and intubation.

Materials and Methods

This prospective, randomized, parallel-group study was approved by the Institutional Review Board of the Chonnam National University Hospital (IRB no. 2019-361). The study has been registered at the Clinical Research Information Service of the Korea National Institute of Health (https://cris.nih.go.kr) under the registration number KCT0004589. The study was conducted in a university hospital between December 2019 and March 2021, in accordance with the principles of the 2013 Declaration of Helsinki. Written informed consent was obtained from all participants prior to enrollment.
This study enrolled patients with BMI ≥ 35 kg/m2, age 20–80 years, and an American Society of Anesthesiologists physical status classification of I–III who were scheduled to receive general anesthesia for surgery with orotracheal intubation. Patients with a history of difficult intubation, cervical spine defect, previous head and neck surgery, or risk of pulmonary aspiration were excluded. Preoperative airway evaluation was conducted the day before surgery and included Mallampati classification, neck circumference, sternomental distance, thyromental distance, and inter-incisor distance.
Patients were divided into two groups: a sniffing position group and a ramped position group. Position allocation was based on a computer-generated random number list with random block sizes of 2 and 4, which was prepared by an investigator with no clinical involvement in the trial. In the sniffing group, the patient was placed in the supine position with a 7-cm-high pillow placed under the occiput. For the ramped group, pillows were placed under the patient’s upper body and head such that the external auditory meatus and sternal notch were horizontal. The height of the operating table for patients in both groups was adjusted to ensure that the patient’s head was located between the anesthesiologist’s lower xiphoid process and the upper part of the umbilicus.
Upon arrival in the operating room, the patient was placed in the assigned position (sniffing or ramped position) with standard monitors, including for electrocardiogram, non-invasive blood pressure, pulse oximetry, and capnography. All patients were preoxygenated with 100% oxygen for 3 min, after which anesthesia was induced with propofol and remifentanil. After loss of consciousness, repetitive train-of-four (TOF) stimulation was started and rocuronium (0.6–1.0 mg/kg of ideal body weight) was administered.
The difficulty in manual mask ventilation was assessed using the Warters scale, which assigns points based on escalating levels of intervention to achieve a target tidal volume of 5 ml/kg of ideal body weight (Table 1) [19]. If the target tidal volume was not achieved, an airway device, increased inspiratory pressure, and two-person ventilation were used. The mask ventilation score was recorded when the TOF count reached zero. Difficult mask ventilation was defined as a score ≥ 4 on the Warters scale [20].
Tracheal intubation was performed using a C-MAC® D-Blade videolaryngoscope (Karl Storz, Germany) (Fig. 1). The videolaryngoscope blade has a large upward curvature at its distal end [21]. The internal diameter of the endotracheal tube was 8 mm for men and 7 mm for women; each stylet was pre-shaped to resemble the curvature of the C-MAC D-blade. All mask ventilation and tracheal intubation procedures were performed by a single faculty anesthesiologist who had experience in anesthesia for more than 10 years and was experienced with the use of the C-MAC D-blade videolaryngoscope.
The difficulty in tracheal intubation was assessed using the Intubation Difficulty Scale (IDS) [22]. The IDS score was derived from the sum of seven variables, which consisted of the number of intubation attempts, number of additional operators, number of alternative intubation techniques used, Cormack grade of laryngeal view, use of increased lifting force during laryngoscopy, application of external laryngeal pressure, and position of the vocal cord under laryngoscopic view. The degree of difficulty was categorized as easy (IDS = 0), slightly difficult (IDS = 1 to 5), moderate to major difficulty (IDS > 5), or impossible intubation (IDS = infinity) according to the IDS score.
Laryngoscopy and tube insertion times were measured separately to distinguish between difficult laryngoscopy and difficult tube insertion. Laryngoscopy time was measured from the time when the blade tip touched the patient’s lip until the best glottic view was achieved on the video laryngoscope monitor. Tube insertion time was measured from the time the endotracheal tube was inserted into the patient’s mouth until the passage of the tube through the glottis. The total intubation time was calculated as the sum of the laryngoscopy and tube insertion times. Intubation failure was defined as a total intubation time > 90 s or esophageal intubation.
Sample size was determined based on the mean intubation time estimated in a pilot study (n = 12 for each group), reporting a mean difference of 7.6 s and a standard deviation of 11.6 s. Power analysis showed that a sample size of 76 patients (38 patients in each group) would provide a statistical power of 0.8 with a two-sided level of 0.05 to detect significant differences. Considering possible dropouts, a total sample size of 82 patients was calculated.
The Kolmogorov–Smirnov test was performed to examine the assumption of normality. Normally distributed continuous variables were compared using the Student’s t-test; non-normally distributed continuous variables and ordinal variables were compared using the Mann–Whitney U test. Categorical variables were compared using the chi-square test or Fisher’s exact test. Data are presented as the number of patients, mean ± SD, or median (Q1, Q3). Statistical significance was set at P < 0.05.

Results

Among the 93 patients screened for eligibility, 11 were excluded for the reasons shown in Fig. 2. Eighty-two patients were randomized in the study, but one patient in the ramped group was excluded because the operation was canceled. Thus, the study population comprised of 81 patients (40 patients for the ramped group and 41 patients for the sniffing group). There were no significant differences in the demographic data and airway parameters between the two groups (Table 2).
The incidence of difficult mask ventilation was significantly lower in the ramped than in the sniffing group (2.5% vs. 34.1%, P < 0.001) (Table 3). The rate of easy intubation was significantly higher in the ramped than in the sniffing group (70.0% vs. 7.3%, P < 0.001). The rate of Cormack grade I was higher in the ramped than in the sniffing group (95.0% vs. 63.4%, P = 0.001), although poor visualization of the glottis (Cormack grade ≥ 3) under videolaryngoscopy was not observed in either group. Increased lifting force to expose the glottis during videolaryngoscopy was less frequent in the ramped than in the sniffing group (5.0% vs. 80.5%, P < 0.001). Neither group had failed mask ventilation or intubation.
The total intubation time, which was the primary outcome of the study was significantly shorter in the ramped than in the sniffing group (22.5 ± 6.2 vs. 40.9 ± 9.0 s; mean difference [95% CI] 18.4 [15.0, 21.8], P < 0.001) (Fig. 3). Two components of the total intubation time were also significantly shorter in the ramped than in the sniffing group, respectively (10.0 ± 2.7 vs. 18.9 ± 4.5 s for laryngoscopy time, P < 0.001; 12.5 ± 4.9 vs. 22.0 ± 7.3 s for tube insertion time, P < 0.001).

Discussion

In the present study, intubation time using a videolaryngoscope was compared between morbidly obese patients placed in the ramped versus the sniffing position. All intubations were completed successfully in both positions. However, the total intubation time was significantly shorter in the ramped than in the sniffing group. Laryngoscopy and tube insertion times (components of the total intubation time) were also shorter in the ramped group. Additionally, mask ventilation and tracheal intubation were easier in the ramped than in the sniffing group. These results suggest that despite the advantage conferred by videolaryngoscopy in all patients, the ramped position remains useful for tracheal intubation in obese patients.
The long laryngoscopy time of the patients in the sniffing position can be explained by the difficult insertion of the laryngoscope blade. During laryngoscope insertion into the oral cavity, the tip of the laryngoscope handle moves towards the patient’s chest. For morbidly obese patients in the sniffing position, laryngoscope insertion and manipulation are often impeded by the anterior expansion of the chest cavity, which results from increased fat deposition (Fig. 4). A similar problem frequently occurs in pregnant patients, in whom the use of a short laryngoscope handle has been clinically accepted because pregnancy-related breast enlargement could be an impediment to intubation with a standard laryngoscope handle [23].
However, a short-handle design is not available for most videolaryngoscopes, including the C-MAC® D-Blade videolaryngoscope used in the present study. Furthermore, the C-MAC® D-Blade has a hyperangulation of 40°, in contrast to the 18° angulation of conventional C-MAC blades [21]. Hyperangulation may further increase the difficulty of blade insertion because the handle must be more sloped to allow the hyperangulated blade to enter the oral cavity [24]. For patients in the sniffing position, a longer laryngoscopy time may be required for additional manipulations, including 90° rotation of the handle to the right or blade orientation in the reverse direction [24,25]. In contrast, patient placement in the ramped position provides more space for conventional handling of the laryngoscope.
The tube insertion time was also significantly shorter in the ramped than in the sniffing group, although videolaryngoscopy provided adequate exposure of the glottis (Cormack grade 1 or 2) for all patients. This finding demonstrated that the tube tip movement toward the glottic opening and tube advancement into the trachea are easier when obese patients are placed in the ramped position.
One possible explanation for this finding is that the oropharyngeal airway may widen in the ramped position. Obese patients have a smaller upper airway cavity, which tends to collapse as fat accumulates in the upper respiratory tract and tongue [2629]. A large amount of soft tissue around the neck may also affect upper-airway patency [30]. For non-obese patients, elevating the head from the table in the sniffing position produces an increased distance between the mentum and cervical column compared to the neutral position, resulting in a wider oropharyngeal airway [31]. For obese patients, however, this distance might not be increased adequately in the standard sniffing position because of their increased fat deposition in the back. The head is more elevated in the ramped position than in the sniffing position, which increases the distance between the mentum and the cervical column. Thus, the ramped position may provide wider space for tube advancement to the glottic opening. This mechanism is supported by the IDS score, which indicates a lower need for an abnormally increased lifting force during laryngoscopy in patients in the ramped position.
An alternative explanation for the difference in tube insertion time is the disparity between the view and the tracheal axes. During direct laryngoscopy, the view axis (the operator’s eye) and tracheal axis are generally similar if the three airway axes exhibit good alignment. During videolaryngoscopy, the view axis (with the camera at the distal tip of the blade) and tracheal axis usually form a large angle, especially if the airway axes are not aligned [32]. Increasing the angle between the blade and trachea can complicate tube advancement into the trachea, regardless of adequate laryngeal exposure during videolaryngoscopy [3335]. For obese patients in the ramped position, this angle is probably smaller because the alignment of the airway axes is similar to that in normal-weight patients who are placed in the sniffing position.
Morbid obesity is an independent risk factor of difficult mask ventilation [3638]. In the present study, the ramped position not only facilitated faster and easier tracheal intubation but also made mask ventilation easier in morbidly obese patients when compared with the sniffing position. This finding is consistent with a previous study by Cattano et al. [16], which showed that mask ventilation was easier in 35% of the patients upon shifting from the neutral position to the ramped position. Prolonged intubation time with difficult mask ventilation is expected to be more problematic in morbidly obese patients because the altered respiratory mechanics of these patients can lead to arterial desaturation even after a brief period of apnea, despite adequate preoxygenation [3941]. Therefore, the present study suggests that morbidly obese patients need to be placed in the ramped position during the induction of anesthesia, regardless of whether videolaryngoscopy is used or not.
This study has several limitations. First, a crossover design was not used due to safety concerns. In anesthetized obese patients, multiple position changes and prolonged induction time with an unsecured airway increase the risk of positioning injury or hypoxemia. Second, the assessor could not be blinded due to the nature of interventions used in this study. Third, only one type of videolaryngoscope (with a hyperangulated blade) was used. Thus, caution is needed when generalizing these results to other videolaryngoscopes. Fourth, this was a single-center study, which may limit the applicability of the results to other institutions. Fifth, the time for intubation and the difficulty of intubation were significantly different between the groups in the present study. Thus, the incidence of complications related to tracheal intubation, such as postoperative sore throat or hoarseness, might be different between the groups. However, we did not collect data on the complications of tracheal intubation.
In conclusion, the present study demonstrated that the ramped position could reduce intubation time and achieve easy intubation using videolaryngoscopy in morbidly obese patients. Regardless of videolaryngoscopy usage, the ramped position should be considered to improve airway management in morbidly obese patients.

ACKNOWLEDGMENTS

The authors thank all the patients who participated in the study and the research staff.

Notes

Funding

None.

Conflicts of Interest

No potential conflict of interest relevant to this article was reported.

Data Availability

Data sharing is not applicable to this article as no datasets were generated or analyzed during the current study.

Author Contributions

Seongheon Lee (Formal analysis; Methodology; Writing – original draft)

Eun-A Jang (Investigation; Writing – review & editing)

Minjae Hong (Data curation; Investigation)

Hong-Beom Bae (Validation; Writing – review & editing)

Joungmin Kim (Conceptualization; Investigation; Writing – review & editing)

References

1. Chooi YC, Ding C, Magkos F. The epidemiology of obesity. Metabolism. 2019; 92:6–10.
2. Domi R, Laho H. Anesthetic challenges in the obese patient. J Anesth. 2012; 26:758–65.
3. Lundstrøm LH, Møller AM, Rosenstock C, Astrup G, Wetterslev J. High body mass index is a weak predictor for difficult and failed tracheal intubation: a cohort study of 91,332 consecutive patients scheduled for direct laryngoscopy registered in the Danish Anesthesia Database. Anesthesiology. 2009; 110:266–74.
4. Ezri T, Medalion B, Weisenberg M, Szmuk P, Warters RD, Charuzi I. Increased body mass index per se is not a predictor of difficult laryngoscopy. Can J Anaesth. 2003; 50:179–83.
5. Brodsky JB, Lemmens HJ, Brock-Utne JG, Vierra M, Saidman LJ. Morbid obesity and tracheal intubation. Anesth Analg. 2002; 94:732–6.
6. Gonzalez H, Minville V, Delanoue K, Mazerolles M, Concina D, Fourcade O. The importance of increased neck circumference to intubation difficulties in obese patients. Anesth Analg. 2008; 106:1132–6.
7. Kim WH, Ahn HJ, Lee CJ, Shin BS, Ko JS, Choi SJ, et al. Neck circumference to thyromental distance ratio: a new predictor of difficult intubation in obese patients. Br J Anaesth. 2011; 106:743–8.
8. Juvin P, Lavaut E, Dupont H, Lefevre P, Demetriou M, Dumoulin JL, et al. Difficult tracheal intubation is more common in obese than in lean patients. Anesth Analg. 2003; 97:595–600.
9. Schnittker R, Marshall SD, Berecki-Gisolf J. Patient and surgery factors associated with the incidence of failed and difficult intubation. Anaesthesia. 2020; 75:756–66.
10. Collins JS, Lemmens HJ, Brodsky JB. Obesity and difficult intubation: where is the evidence? Anesthesiology. 2006; 104:617.
11. Members of the Working Party, Nightingale CE, Margarson MP, Shearer E, Redman JW, Lucas DN, Cousins JM, et al. Peri-operative management of the obese surgical patient 2015: Association of Anaesthetists of Great Britain and Ireland Society for Obesity and Bariatric Anaesthesia. Anaesthesia. 2015; 70:859–76.
12. Collins JS, Lemmens HJ, Brodsky JB, Brock-Utne JG, Levitan RM. Laryngoscopy and morbid obesity: a comparison of the “sniff” and “ramped” positions. Obes Surg. 2004; 14:1171–5.
13. Brodsky JB, Lemmens HJ, Brock-Utne JG, Saidman LJ, Levitan R. Anesthetic considerations for bariatric surgery: proper positioning is important for laryngoscopy. Anesth Analg. 2003; 96:1841–2.
14. Levitan RM, Mechem CC, Ochroch EA, Shofer FS, Hollander JE. Head-elevated laryngoscopy position: improving laryngeal exposure during laryngoscopy by increasing head elevation. Ann Emerg Med. 2003; 41:322–30.
15. Rao SL, Kunselman AR, Schuler HG, DesHarnais S. Laryngoscopy and tracheal intubation in the head-elevated position in obese patients: a randomized, controlled, equivalence trial. Anesth Analg. 2008; 107:1912–8.
16. Cattano D, Melnikov V, Khalil Y, Sridhar S, Hagberg CA. An evaluation of the rapid airway management positioner in obese patients undergoing gastric bypass or laparoscopic gastric banding surgery. Obes Surg. 2010; 20:1436–41.
17. Hoshijima H, Denawa Y, Tominaga A, Nakamura C, Shiga T, Nagasaka H. Videolaryngoscope versus Macintosh laryngoscope for tracheal intubation in adults with obesity: a systematic review and meta-analysis. J Clin Anesth. 2018; 44:69–75.
18. Liao CC, Liu FC, Li AH, Yu HP. Video laryngoscopy-assisted tracheal intubation in airway management. Expert Rev Med Devices. 2018; 15:265–75.
19. Warters RD, Szabo TA, Spinale FG, DeSantis SM, Reves JG. The effect of neuromuscular blockade on mask ventilation. Anaesthesia. 2011; 66:163–7.
20. Soltesz S, Alm P, Mathes A, Hellmich M, Hinkelbein J. The effect of neuromuscular blockade on the efficiency of facemask ventilation in patients difficult to facemask ventilate: a prospective trial. Anaesthesia. 2017; 72:1484–90.
21. Cavus E, Neumann T, Doerges V, Moeller T, Scharf E, Wagner K, et al. First clinical evaluation of the C-MAC D-Blade videolaryngoscope during routine and difficult intubation. Anesth Analg. 2011; 112:382–5.
22. Adnet F, Borron SW, Racine SX, Clemessy JL, Fournier JL, Plaisance P, et al. The intubation difficulty scale (IDS): proposal and evaluation of a new score characterizing the complexity of endotracheal intubation. Anesthesiology. 1997; 87:1290–7.
23. Chang LY, Tsen LC. The development and historical context of the Datta short laryngoscope handle. Anesth Analg. 2013; 117:1480–4.
24. Xue FS, Zhang GH, Liu J, Li XY, Yang QY, Xu YC, et al. The clinical assessment of Glidescope in orotracheal intubation under general anesthesia. Minerva Anestesiol. 2007; 73:451–7.
25. Dhonneur G, Ndoko SK, Amathieu R, Attias A, Housseini LE, Polliand C, et al. A comparison of two techniques for inserting the Airtraq laryngoscope in morbidly obese patients. Anaesthesia. 2007; 62:774–7.
26. Hashim MM, Ismail MA, Esmat AM, Adeel S. Difficult tracheal intubation in bariatric surgery patients, a myth or reality? Br J Anaesth. 2016; 116:557–8.
27. Wang SH, Keenan BT, Wiemken A, Zang Y, Staley B, Sarwer DB, et al. Effect of weight loss on upper airway anatomy and the apnea-hypopnea index. The importance of tongue fat. Am J Respir Crit Care Med. 2020; 201:718–27.
28. Genta PR, Schorr F, Eckert DJ, Gebrim E, Kayamori F, Moriya HT, et al. Upper airway collapsibility is associated with obesity and hyoid position. Sleep. 2014; 37:1673–8.
29. Li HY, Lo YL, Wang CJ, Hsin LJ, Lin WN, Fang TJ, et al. Dynamic drug-induced sleep computed tomography in adults with obstructive sleep apnea. Sci Rep. 2016; 6:35849.
30. Sanaie S, Bilejani I, Mortazavi M, Mahmoodpoor A, Negargar S, Faramarzi E, et al. Effect of manual caudal and downward displacement of lower cervical adipose tissue on laryngoscopic grade of patients with morbid obesity. Anesth Pain Med. 2018; 8:e63061.
31. Isono S, Tanaka A, Ishikawa T, Tagaito Y, Nishino T. Sniffing position improves pharyngeal airway patency in anesthetized patients with obstructive sleep apnea. Anesthesiology. 2005; 103:489–94.
32. Levitan RM, Heitz JW, Sweeney M, Cooper RM. The complexities of tracheal intubation with direct laryngoscopy and alternative intubation devices. Ann Emerg Med. 2011; 57:240–7.
33. Cooper RM, Pacey JA, Bishop MJ, McCluskey SA. Early clinical experience with a new videolaryngoscope (GlideScope) in 728 patients. Can J Anaesth. 2005; 52:191–8.
34. Maassen R, Lee R, Hermans B, Marcus M, van Zundert A. A comparison of three videolaryngoscopes: the Macintosh laryngoscope blade reduces, but does not replace, routine stylet use for intubation in morbidly obese patients. Anesth Analg. 2009; 109:1560–5.
35. Paolini JB, Donati F, Drolet P. Review article: video-laryngoscopy: another tool for difficult intubation or a new paradigm in airway management? Can J Anaesth. 2013; 60:184–91.
36. Kheterpal S, Han R, Tremper KK, Shanks A, Tait AR, O’Reilly M, et al. Incidence and predictors of difficult and impossible mask ventilation. Anesthesiology. 2006; 105:885–91.
37. Leoni A, Arlati S, Ghisi D, Verwej M, Lugani D, Ghisi P, et al. Difficult mask ventilation in obese patients: analysis of predictive factors. Minerva Anestesiol. 2014; 80:149–57.
38. Moon TS, Fox PE, Somasundaram A, Minhajuddin A, Gonzales MX, Pak TJ, et al. The influence of morbid obesity on difficult intubation and difficult mask ventilation. J Anesth. 2019; 33:96–102.
39. Ramachandran SK, Cosnowski A, Shanks A, Turner CR. Apneic oxygenation during prolonged laryngoscopy in obese patients: a randomized, controlled trial of nasal oxygen administration. J Clin Anesth. 2010; 22:164–8.
40. Baraka AS, Taha SK, Siddik-Sayyid SM, Kanazi GE, El-Khatib MF, Dagher CM, et al. Supplementation of pre-oxygenation in morbidly obese patients using nasopharyngeal oxygen insufflation. Anaesthesia. 2007; 62:769–73.
41. Berthoud MC, Peacock JE, Reilly CS. Effectiveness of preoxygenation in morbidly obese patients. Br J Anaesth. 1991; 67:464–6.

Fig. 1.
The conventional C-MAC videolaryngoscope blade (Macintosh size 3, [A]) and the hyperangulated C-MAC D-blade (B).
kja-22268f1.tif
Fig. 2.
CONSORT flow diagram.
kja-22268f2.tif
Fig. 3.
Comparison of laryngoscopy time, tube insertion time, and the total intubation time during videolaryngoscopy in the ramped versus sniffing position. Laryngoscopy time: from the insertion of the blade to the best glottic visualization, Tube insertion time: from the insertion of the endotracheal tube to the passage of the tube through the glottis, Total intubation time: laryngoscopy time + tube insertion time.
kja-22268f3.tif
Fig. 4.
Comparison of the difficulty of the videolaryngoscope blade insertion between the sniffing position (A) and the ramped position (B). In the sniffing position, laryngoscope insertion could be impeded by anterior expansion of the chest cavity in morbidly obese patients. In the ramped position, there might be more space for laryngoscope insertion and manipulation.
kja-22268f4.tif
Table 1.
The Warters Grading Scale for Mask Ventilation
Description/definition Points
Oral or nasal airway 1
PIP 20–25 cmH2O 1
PIP 26–30 cmH2O 2
PIP > 30 cmH2O 3
Unable to generate PIP > 30 cmH2O 3
Two-person ventilation 2
Tidal volume 2–5 ml/kg 2
Unable to ventilate 4

The point system is based on the ability to achieve a target volume of 5 ml/kg (ideal body weight). PIP: peak inspiratory pressure.

Table 2.
Demographic Data
Variable Ramped group (n = 40) Sniffing group (n = 41) P value
Sex (M/F) 19/21 20/21 0.908
Age (yr) 40.7 ± 15.7 46.5 ± 14.0 0.085
Height (cm) 162.1 ± 11.9 164.4 ± 10.3 0.350
Weight (kg) 101.6 ± 18.3 100.7 ± 14.2 0.800
BMI (kg/m2) 36.8 (35.6, 40.9) 35.7 (35.2, 38.0) 0.058
ASA physical status (I/II/III) 0/24/16 0/21/20 0.505
Airway parameters
 Mallampati score (I/II/III) 23/14/3 21/20/0 0.128
 Neck circumference (cm) 45.1 ± 5.6 45.2 ± 5.0 0.918
 Sternomental distance (cm) 16.0 (14.9, 17.0) 15.2 (14.5, 16.8) 0.435
 Thyromental distance (cm) 8.1 (6.8, 9.0) 8.2 (7.0, 8.8) 0.527
 Inter-incisor distance (cm) 4.9 (4.5, 5.0) 5.0 (4.4, 5.2) 0.895

Values are presented as number of patients or mean ± SD or median (Q1, Q3). BMI: body mass index, ASA: American Society of Anesthesiologists.

Table 3.
Difficulty in Mask Ventilation and Tracheal Intubation
Variable Ramped group (n = 40) Sniffing group (n = 41) P value
Difficulty of mask ventilation
 Warters scale 1 (1, 2) 3 (2, 4) < 0.001
 No. of difficult cases (a score ≥ 4) 1 (2.5) 14 (34.1) < 0.001
Difficulty of intubation
 IDS score 0 (0, 1) 2 (1, 3) < 0.001
  A. No. of attempts (n-1)
   1 40 (100) 37 (90.2) 0.116
   2 0 (0) 4 (9.8)
  B. No. of operators (n-1)
   1 40 (100) 41 (100) N/A
  C. No. of alternative techniques (n)
   0 40 (100) 34 (82.9) 0.012
   1 0 (0) 7 (17.1)
  D. Cormack grade (grade - 1)
   1 38 (95.0) 26 (63.4) 0.001
   2 2 (5.0) 15 (36.6)
  E. Lifting force required (increased = 1) 2 (5.0) 33 (80.5) < 0.001
  F. External laryngeal pressure (applied = 1) 5 (12.5) 13 (31.7) 0.060
  G. Vocal cord mobility (adduction = 1) 5 (12.5) 2 (4.9) 0.264
Ease of intubation
 Easy (IDS = 0) 28 (70.0) 3 (7.3) < 0.001
 Slight difficulty (0 < IDS ≤ 5) 12 (30.0) 38 (92.7)
 Moderate to major difficulty (IDS > 5) 0 (0) 0 (0)

Values are presented as the number of patients (%) or median (Q1, Q3). IDS score = sum of score of seven variables (A–G). An intubating stylet was routinely used during videolaryngoscopy and was not considered an alternative technique. IDS: intubation difficulty scale, N/A: not applicable.