INTRODUCTION
The incidence of rotator cuff tears is increasing rapidly, mainly due to the aging population and advancements in radiological diagnosis. Tears are reported in approximately 30% of those aged ≥ 60 years and nearly 60% of those aged ≥ 80 years [
1,
2]. Arthroscopic rotator cuff repair has become a common surgical technique for treating rotator cuff tears, and as it is minimally invasive, it may have the additional benefits of reducing postoperative pain and improving early functional recovery [
3]. Additionally, there is recent growing interest in various methods for improving functional recovery of patients after arthroscopic shoulder surgery, one of them being the use of far-infrared radiation (FIR) [
4].
FIR is an electromagnetic wave, which is also emitted from the sun, and has wavelengths between 5.6 and 25.0 μm [
5]. Depending on its wavelength, infrared radiation can be divided into the following three categories: near-infrared radiation (0.8-1.5 μm), middle-infrared radiation (1.5-5.6 μm), and FIR (5.6-1,000 μm) [
5]. FIR has three biological effects, including radiation, resonance, and thermal effects [
6]. FIR carries energy that is perceived as heat by thermo-receptors on the surrounding skin and can penetrate up to 4 cm beneath the skin [
7]. Moreover, it can resonate with water and organic molecules within the body [
8]. According to Wien law, the dominant wavelength of radiation emitted by a body at 35°C is 9.4 μm. This explains why the human body easily absorbs FIR between 4 and 16 μm [
9]. The FIR radiator used generates a 2-25 µm wavelength similar to the wavelength of the human body. The human body of an adult consists of 55%-60% water. FIR interacts with water molecules, causing a thermal reaction that raises the temperature of the tissue. The human body responds to this phenomenon by expanding blood vessels. Subsequently, blood circulation increases, more oxygenated blood reaches soft tissue, and at the same time, it stimulates the removal of accumulated toxins [
8].
The FIR effect has been demonstrated by animal studies in rats, which resulted in increased nutrient supply to tissues, accelerated tissue repair, improved waste removal, and elevated pain thresholds [
5,
10]. Wong et al. [
6] reported that FIR promoted local circulation and improved capillary flow after total knee arthroplasty. Subsequently, FIR may increase tissue oxygenation and improve healing by eliminating chronic inflammation, reducing pain and swelling, relieving muscle spasms, inducing relaxation of musculotendinous structures, and eventually relieving symptoms [
5,
6]. In orthopedic fields, FIR may be useful for wound healing and analgesia [
6]. However, no comparative study has been performed to date that investigates the use of FIR after arthroscopic rotator cuff repair. Moreover, no studies have looked at how FIR may affect postoperative pain-relief, functional recovery, and rotator cuff healing during the tissue healing phase.
In this prospective randomized comparative study, we aimed to evaluate the safety and efficacy of FIR after arthroscopic rotator cuff repair, based on the hypothesis that FIR can improve postoperative pain, functional recovery, and healing effects after surgery.
Go to :

RESULTS
Each patient was given a self-checklist to record the exact time and site of the irradiation throughout the treatment period. We confirmed their data, and all patients answered that they complied with the protocol well.
Demographic data, including preoperative pVAS, showed no difference between the FIR and control groups (
Table 1). The pVAS at 5 weeks postoperatively, which was the primary outcome, was 1.5 ± 0.8 in the FIR group, which was statistically significantly lower than 2.7 ± 1.7 in the control group (
P = 0.019,
Table 2).
Table 1
Preoperative Demographic Data of Patients
Variable |
FIR group (n = 19) |
Control group (n = 19) |
P value |
Age (yr) |
62.8 ± 7.5 |
60.8 ± 8.5 |
0.232 |
Sex (male/female) |
10/9 |
7/12 |
0.328 |
Height (m) |
1.6 ± 0.1 |
1.6 ± 0.1 |
0.114 |
Weight (kg) |
67.0 ± 9.3 |
65.9 ± 13.4 |
0.403 |
Tear retraction (mm) |
15.9 ± 6.3 |
16.2 ± 6.5 |
0.722 |
Tear AP diameter (mm) |
14.8 ± 4.0 |
13.4 ± 4.1 |
0.259 |
pVAS (points) |
5.5 ± 2.4 |
4.9 ± 2.3 |
0.407 |
ASES score |
56.8 ± 18.9 |
55.5 ± 19.0 |
0.839 |
SST score |
5.4 ± 3.3 |
3.5 ± 3.7 |
0.084 |
Range of motion |
|
|
|
Forward flexion (º) |
157.4 ± 10.5 |
148.2 ± 17.9 |
0.162 |
External rotation at the side (º) |
51.6 ± 15.4 |
49.7 ± 14.6 |
0.678 |
Internal rotation at the back (level)a
|
9.5 ± 1.8 |
10.8 ± 3.4 |
0.398 |

Table 2
pVAS Score and Range of Motion at 5 Weeks Postoperatively
Variable |
FIR group (n = 19) |
Control group (n = 19) |
P value |
pVAS (points) |
1.5 ± 0.8 |
2.7 ± 1.7 |
0.019*
|
Range of motion |
|
|
|
Forward flexion (º) |
84.2 ± 20.0 |
79.5 ± 23.9 |
0.243 |
External rotation at the side (º) |
22.6 ± 9.2 |
23.4 ± 12.0 |
0.911 |
Internal rotation at the back (level)a
|
17.7 ± 0.6 |
17.3 ± 1.7 |
0.910 |

For the secondary outcomes, pVAS at 3 and 6 months postoperatively were not different between the two groups. The pVAS at 3 months postoperatively was 2.1 ± 0.9 in the FIR group, which was not significantly different from 2.7 ± 1.9 in the control group (
P = 0.344,
Table 3). The pVAS at 6 months postoperatively was 0.7 ± 1.3 in the FIR group, which was not statistically different from 0.6 ± 1.0 in the control group (
P = 0.928,
Table 4). At 3 months after surgery, the average FF was 151.6° ± 15.3° in the FIR group, which was significantly higher than 132.9° ± 27.8° in the control group (
P = 0.045,
Table 3), but there was no significant difference in the FF at 6 months postoperatively. Other ROMs were not significantly different between the two groups at 3 and 6 months postoperatively. In addition, functional outcome measurements at 6 months postoperatively, including ASES and SST scores, were not significantly different between the two groups (
P = 0.352 for ASES score and
P = 0.647 for SST,
Table 4).
Table 3
pVAS Score and Range of Motion at 3 Months Postoperatively
Variable |
FIR group (n = 19) |
Control group (n = 19) |
P value |
pVAS (points) |
2.1 ± 0.9 |
2.7 ± 1.9 |
0.344 |
Range of motion |
|
|
|
Forward flexion (º) |
151.6 ± 15.3 |
132.9 ± 27.8 |
0.045*
|
External rotation at the side (º) |
38.4 ± 10.8 |
35.3 ± 17.0 |
0.682 |
Internal rotation at the back (level)a
|
12.7 ± 2.4 |
13.1 ± 3.1 |
0.396 |

Table 4
Clinical Outcomes at 6 Months Postoperatively
Variable |
FIR group (n = 19) |
Control group (n = 19) |
P value |
pVAS (points) |
0.7 ± 1.3 |
0.6 ± 1.0 |
0.928 |
ASES score |
88.2 ± 10.2 |
90.7 ± 9.3 |
0.352 |
SST score |
9.9 ± 1.5 |
10.1 ± 1.8 |
0.647 |
Range of motion |
|
|
|
Forward flexion (º) |
154.5 ± 8.3 |
155.0 ± 10.1 |
0.988 |
External rotation at the side (º) |
61.6 ± 12.6 |
61.6 ± 18.6 |
0.858 |
Internal rotation at the back (level)a
|
9.8 ± 1.7 |
9.1 ± 1.3 |
0.299 |

Regarding the third outcome, which was the tendon-to-bone healing rate of the rotator cuff at 3 months postoperatively, via ultrasound, and at 6 months postoperatively, via MRI, there was no significant difference in the healing failure between the two groups. At 3 months postoperatively, no healing failure was found in either group using ultrasound, but there were two healing failure cases (10.5%) in the FIR group and one healing failure case (5.3%) in the control group (P = 0.999) at 6 months postoperatively, via MRI.
The potential adverse effects of FIR, such as skin burn, rash, infection, wound dehiscence, hypersensitivity reaction, and body temperature elevation, did not occur in our patients. Moreover, there were no other perioperative complications noted in any patient in either group.
Go to :

DISCUSSION
This prospective randomized comparative study evaluated the safety and efficacy of FIR after rotator cuff repair, and the current data demonstrated that the pVAS was significantly lower in the FIR group than in the control group at 5 weeks postoperatively. At 3 months postoperatively, the average FF was significantly higher in the FIR group than in the control group; however, other variables including the pVAS were not significantly different. At 6 months postoperatively, there were no differences in the pVAS, ROM, functional scores, or healing failure rate between the two groups, and adverse events from FIR were not observed in the FIR group.
In the medical field, FIR is usually used for patients with lymphedema and vascular disease [
8,
16]. Its surgical application has been actively investigated for plastic surgery and oral-maxillofacial surgery [
17,
18]. In plastic surgery, FIR has been proven to induce wound healing by increasing skin microcirculation in rats undergoing flap treatment [
17]. In oral-maxillofacial surgery, FIR has been proven to aid wound healing after tooth extraction [
18,
19]. The application of FIR is still unchartered territory in the orthopedic field. However, we hope that our research will be a cornerstone in proving the efficacy and safety of its clinical use. Further studies into FIR are required not only to evaluate its effectiveness in the clinical setting, such as increasing microcirculation, but also to determine its latent mechanisms.
Pain is an important factor experienced by patients after elective surgery and usually occurs due to the injury of nerve endings and soft tissue damage [
6,
20]. According to previous studies, 77%-98% of patients experienced postoperative pain, and up to 50% of this same group experienced moderate pain [
6,
21]. Severe pain adversely affects patients’ biologic, physical, and psychological status [
20].
Additionally, arthroscopic rotator cuff repair causes more severe pain than arthroscopic surgery of other joints owing to bone resection, extensive removal of bursal tissue, insertion of a suture anchor, and soft tissue distension from irrigation fluid [
22]. This postoperative pain usually interferes with early rehabilitation, adversely affecting surgical outcomes and extending hospitalization, leading to decreased patient satisfaction [
23]. Proper pain control after arthroscopic rotator cuff repair can prevent serious complications by reducing hospitalization, thereby achieving early ROM and muscle strength [
24]. In our study, pVAS was significantly lower in the FIR group than the control group 5 weeks postoperatively (
P = 0.019). This indicates that FIR significantly improved pain-relief, particularly in the early postoperative period. This corresponds with the regional irradiation achieved by FIR, penetrating almost 4 cm beneath the skin, and causing local capillary dilatation due to transmission of thermal energy [
7]. As a result, it increases nutrient supply to specific tissue, promotes tissue repair, improves elimination of waste, and raises patients’ pain threshold [
5,
6]. Moreover, Wong et al. [
6] reported that patients who received FIR after total knee arthroplasty have reduced interleukin-6 (IL-6), indicating an anti-inflammatory effect. IL-6 is secreted by injured tissue, and plays a central role in the immune response [
25]. IL-6 level correlates not only with inflammation, but also with pain-relief [
6]. Reducing pain facilitates postoperative rehabilitation of patients who have undergone arthroscopic rotator cuff repair [
24].
As mentioned previously, proper pain control after arthroscopic rotator cuff repair can lead to early ROM achievements [
24,
26]. In our study, FF in ROM was significantly higher in the FIR group than in the control group at 3 months postoperatively (
P = 0.045), which supports the preceding sentence. Recent studies have shown that FIR reduces wound healing time and provides soothing effects and pain-relief following standard medical wound treatment [
18]. However, in the current study, pVAS at 3 and 6 months after surgery was not significantly different. Moreover, except for FF at 3 months postoperatively, ROM was not significantly different between the two groups at 3 and 6 months after the operation. Supporting these results, the functional outcome at 6 months after surgery, including ASES and SST scores, were also not significantly different (
P = 0.352 and
P = 0.647, respectively). The results of these findings suggest that FIR for 5 weeks after surgery may help in reducing early postoperative pain, thereby promoting early ROM at 3 months postoperatively. It is necessary to conduct a subsequent long-term study of pVAS, ROM, and functional outcomes, while continuing to apply FIR until 3-6 months postoperatively to determine if this further reduces pain and facilitates postoperative rehabilitation in patients who had undergone arthroscopic rotator cuff repair.
Martin [
27] explained that wound healing involves the following three steps: inflammation, granulated tissue formation, and tissue remodeling. In the first inflammatory phase, transforming growth factor (TGF)-β1 and platelet-derived growth factor are released from macrophages. In the second granulation phase, TGF-β1 activates fibroblasts to produce extracellular matrix proteins, such as collagen and fibronectin. Finally, in the third tissue remodeling phase, TGF-β1 enables fibroblast migration, which is a critical step in wound healing. Toyokawa et al. [
5] reported that FIR can influence skin wound healing by stimulating secretion of TGF-β1 or by activating fibroblasts independent of skin blood flow and skin temperature. They proved that the number of migrating fibroblasts expressing TGF-βl was significantly higher in the FIR group. Secretion of TGF-β1 by platelets and macrophages is thought to be enhanced by FIR; as a result, TGF-β1 stimulates fibroblast migration. Consequently, collagen production was also increased in the FIR group. The production of collagen fibers due to FIR-induced activation of fibroblasts has been considered as a possible mechanism for the promotional effect of FIR on wound healing [
5].
However, in our study, the healing failure rate was not statistically different (
P = 0.999). Taking into account the same postoperative rehabilitation process after FIR application, subjects of this study were patients with relatively small tears (1-3 cm). Therefore, healing is expected to be satisfactory without FIR [
2]. Subsequent studies should include patients with larger rotator cuff tears to determine whether FIR would enhance rotator cuff healing. Furthermore, longer periods of FIR application would enhance rotator cuff healing. Considering that the rotator cuff healing process usually continues up to 6 months after surgical repair, it would be better to verify whether FIR lasting for 3-6 months postoperatively would enhance rotator cuff healing. More research is needed with respect to the regularity and durations of radiation, and the effective wavelength range [
5,
27,
28].
There are several strengths in this study. First, this is the first prospective randomized comparative clinical trial for evaluating the efficacy and safety of FIR after rotator cuff repair. Until now, there have been several studies investigating the clinical application of FIR, mainly for skin or lymphedema [
8,
29,
30]. Therefore, the results of this preliminary analysis seem to be promising and could be applied especially to other orthopedic fields. Second, the current study included homogenous patients in terms of tear size, operation time, difficulties and extent of surgery, and rehabilitation; thus, we can estimate the effects of FIR more objectively. However, our work was subject to several limitations as well. First, this study had a relatively short-term follow-up. Although adverse effects such as hypersensitivity reaction and re-tear of the repaired rotator cuff are known to occur in the early postoperative period, long-term follow-up is needed to evaluate the efficacy and safety of FIR. Second, as we have discussed above, patients with larger tears should be included, and several options of FIR application, such as duration, regularity, and wavelength, should be investigated in a future large-scale and long-term clinical studies to verify the healing effect of FIR. Third, at 3 months after surgery, only FF, except ER and IR, is statistically significant. So, it is a little difficult to conclude that the effect of FIR is on ROMs improvement. Lastly, it is impossible to ensure patient compliance, although we have provided a checklist to record the exact time and site of irradiation throughout the treatment period.
In conclusion, FIR after arthroscopic rotator cuff repair could be an effective and safe procedure to reduce postoperative pain, thereby facilitating postoperative rehabilitation and resulting in better ROM in the early postoperative period. Further studies and clinical trials are needed with respect to the regularity and durations of radiation, effective wavelength range, and rotator cuff healing.
Go to :
