Journal List > Anesth Pain Med > v.14(3) > 1158455

Park and Lee: Effects of fetal position on maternal hemodynamics after spinal anesthesia for cesarean delivery

Abstract

Background:

Aortocaval compression by the gravid uterus is a known physiological phenomenon that is classically claimed to cause supine hypotension in full-term pregnant women. This study aimed to investigate the effects of fetal position on maternal hemodynamics after spinal anesthesia during cesarean delivery.

Methods:

In total, 71 women with intrauterine pregnancy over 36 weeks of gestation who were scheduled for elective cesarean delivery under spinal anesthesia were enrolled in the study. Based on the fetal position, the women were divided into two groups: right position group (group R) and left position group (group L). Occurrence of hypotension, requirement for rescue bolus injections of phenylephrine, and the total amount of infused phenylephrine before delivery were recorded in each group.

Results:

There was no statistically significant difference in the occurrence of hypotension between the two groups (P = 0.075); however, the amount of phenylephrine required before delivery was significantly greater in group R (P = 0.028). There was a statistically significant decrease in the systolic blood pressure compared with the baseline values in group R, and this change persisted until 15 min after spinal anesthesia.

Conclusions:

There was no difference according to fetal position in the number of patients who showed hypotension before delivery after spinal anesthesia.

INTRODUCTION

Aortocaval compression by the gravid uterus is a known physiological phenomenon that causes supine hypotension in full-term pregnant women [1]. Hypotension during spinal anesthesia may cause nausea and vomiting, and long-term severe hypotension may cause unconsciousness, pulmonary aspiration, hypoxia, acidosis, as well as fetal neurological injury due to reduction of uteroplacental blood flow [2]. Management of hypotension during regional anesthesia includes position change, fluid therapy, administration of vasopressors, and use of nonpharmacological methods [3]. Although position change using a tilt or a wedge is considered necessary, this management does not completely prevent hypotension resulting from aortocaval compression [4]. Neuraxial anesthesia blunts the cardiovascular compensatory mechanisms during cesarean delivery, and this may exacerbate maternal hypotension in the supine position. Additional factors, such as the size of the uterus, and maternal and fetal position, can be associated with aortocaval compression during neuraxial anesthesia [5]. Extensive paralysis of sympathetics and failure to relieve compression of the inferior vena cava could lead to a fatal fall in cardiac output [6].
This study aimed to investigate the differences, if any, according to the fetal position in the rate of hypotension by aortocaval compression with gravid uterus after spinal anesthesia during cesarean delivery.

MATERIALS AND METHODS

This single institutional prospective double-blind study was reviewed and approved by our hospital institutional review board, and informed consent was obtained from each patient.
In total, 71 American Society of Anesthesiology physical status classification I healthy patients with intrauterine pregnancy over 36 weeks of gestation who were scheduled for elective cesarean delivery under spinal anesthesia were enrolled in the study between August 24, 2017 and January 25, 2018. The exclusion criteria were cardiovascular or cerebrovascular disease, placenta previa, pregnancy-related hypertensive disease (systolic blood pressure greater than or equal to 150 mmHg), height < 150 cm or > 180 cm, weight < 50 kg or > 100 kg, known fetal abnormalities, fever, twin pregnancies, and diabetes mellitus.
In the operating room, fetal heart rate was monitored and fetal position was recorded by an obstetrician before spinal anesthesia was induced. When fetal heartbeat is detected using Doppler ultrasound fetal monitor, an ultrasound probe is fixated on the patient’s abdomen where the best fetal heart signal can be obtained. If the probe is positioned to the right or left side of the midline of abdomen of the patient, the fetal position is considered on the right or left, respectively. Based on the fetal position, the patients were divided into two groups: fetal right position group (group R) and fetal left position group (group L).
Patients were not premedicated, and they were administered lactated Ringer’s solution at the full rate upon entering the operating room.
Patients in both groups were monitored using automated blood pressure-measuring devices, electrocardiography, and pulse oximetry on entering the operating room. After resting in the supine position for several minutes, the patients underwent noninvasive blood pressure measurements three times. The baseline systolic blood pressure (SBP) was calculated as the mean of three SBP recordings.
Spinal anesthesia was administered while the patient was in the left lateral position at the L3–4 or L4–5 vertebral interspace; 0.5% hyperbaric bupivacaine (10 mg) and fentanyl (15 μg) were injected intrathecally using a 25-gauge pencil-point needle (Pencan®, B/Braun, Germany). After the induction of spinal anesthesia, phenylephrine was infused at a rate of 50 μg/min in each group. Hypotension, defined as SBP ≤ 80% of the baseline SBP despite phenylephrine infusion, was treated with a 100-μg bolus of phenylephrine.
We measured the BP and heart rates (HRs) of the patients at 1-min intervals for 5 min and 2-min intervals after 5 min after the induction of spinal anesthesia until delivery, and at 5-min intervals for 30 min after delivery. Bradycardia was defined as HR < 50 beats/min and was treated with atropine (0.5 mg). After delivery, fetal body weight and Apgar scores at 1 and 5 min were recorded. Amniotic fluid index was also recorded. As a primary outcome measure, the number of patients who showed hypotension at least once was compared before delivery after spinal anesthesia. As a secondary outcome measure, the total infused doses of phenylephrine including bolus doses before delivery were compared.

Statistical analysis

In a pilot study, we compared the rate of hypotension between two groups before delivery by using the same methods as those used in this study. In total, 36 patients were enrolled, and the rate of hypotension was 70% (14 patients) in group R (20 patients) and 31% (5 patients) in group L (16 patients). The sample size for detecting significant difference in the rate of hypotension between two groups before delivery required to obtain a statistical power of 80% with an α error of 0.05 was determined to be 30 patients in each group. Assuming a dropout rate of 10%, we enrolled 71 patients in this study.
Data are expressed as means ± SDs, medians (1Q, 3Q), or numbers (percentages).
Continuous variables such as SBP and HR were tested for normality using the Shapiro–Wilk test, and SBP was analyzed using two-way repeated measures ANOVA in one factor (following sphericity test) and HR, using Friedman repeated measures ANOVA on Ranks with Dunnett’s method for pairwise comparisons within each group. The Student’s t-test or Mann–Whitney rank sum test according to normality test were used for comparison of measurements (patient characteristics, outcome data) between the two groups. The rate of hypotension between the two groups was compared using the χ2 test or Fisher’s exact test. Statistical analyses, and sample size and power calculations were performed using Sigma Stat version 4.0 (Systat Software Inc., USA). P values < 0.05 were considered statistically significant.

RESULTS

Four patients were excluded because they had elevated SBP above 150 mmHg. They were administered nicardipine or labetalol in the operating room before the induction of spinal anesthesia. A total of 67 patients were finally included in the study (Fig. 1). There were no statistical differences in the demographic data between the two groups (Table 1).
Fig. 1
Consolidated Standards of Reporting Trials flow diagram.
APM_14_266_fig_1.tif
Table 1
Patient Characteristics
Variable Group L (n = 30) Group R (n = 37)
Maternal age (yr) 33.8 ± 3.6 33.0 ± 3.0
Maternal weight (kg) 66.4 (62.7, 81.8) 67.8 (63.2, 77.3)
Maternal height (cm) 160.5 ± 5.7 161.7 ± 5.5
Gestational age (wk) 39.0 ± 1.1 39.0 ± 1.1
Gravidity 1 (1, 2) 2 (1, 2)
Parity 0 (0, 1) 0 (0, 1)
Birth weight (g) 3,308 ± 355 3,216 ± 318
AFI 11.0 ± 3.2 11.9 ± 3.4

Values are presented as mean ± SD or median (1Q, 3Q). There were no significant differences between the groups. Group L: left fetal position group, Group R: right fetal position group, AFI: amniotic fluid index.

As primary outcome data, the rate of hypotension in group L was 40% (12 patients). Of the 12 patients, 6 patients showed hypotension only once, 4 patients showed hypotension twice, and 2 patients showed hypotension three or more times before delivery. The rate of hypotension in group R was 65% (24 patients). Of the 24 patients, 6 patients showed hypotension only once, 10 patients showed hypotension twice, and 8 patients showed hypotension three or more times before delivery. There was no significant difference in the rate of hypotension before delivery between the two groups (P = 0.075) (Table 2).
Table 2
Outcome Data
Characteristics Group L (n = 30) Group R (n = 37) P value
Sensory block height (coldness) T4 (T3, T4) T3 (T3, T4) 0.301
Hypotension before delivery 12 (40) 24 (65) 0.075
 Once 6 (20) 6 (16) 0.935
 Twice 4 (13) 10 (27) 0.285
 Three or more times 2 (7) 8 (22) 0.166
Phenylephrine dose before delivery (μ.g) 308 (217, 375) 375 (300, 467) 0.028*
No. of patients with bradycardia 3 (10) 2 (5) 0.650
Time to delivery after SA (min) 14.5 (13.0, 18.0) 14.0 (13.0, 16.0) 0.768
1-min Apgar score 8 (8, 8) 8 (8, 8) 0.032*
5-min Apgar score 9 (9, 9) 9 (9, 9) 0.317
Amount of infused fluid (ml) 1,550 (1,325, 1,688) 1,600 (1,500, 1,800) 0.204
Estimated blood loss (ml) 700 (600, 900) 700 (600, 800) 0.758

Values are presented as median (1Q, 3Q) or number (%). Group L: left fetal position group, Group R: right fetal position group, SA: spinal anesthesia.

* P < 0.05 compared with group L.

The total phenylephrine dose required before delivery was significantly higher in group R (P = 0.028), and the 1-min Apgar score was significantly lower in group R (P = 0.032) (Table 2).
There were statistically significant decreases in SBP compared with the baseline values in both groups from 2 min after the spinal anesthesia; however, there was no significant difference in SBP between the groups (Fig. 2).
Fig. 2
Systolic blood pressure changes for 15 min after induction of spinal anesthesia. SBP: systolic blood pressure, Group L: left fetal position group, Group R: right fetal position group. *P < 0.05 compared with the baseline value in group L. †P < 0.05 compared with the baseline value in group R.
APM_14_266_fig_2.tif
There were statistically significant decreases in HR compared with the baseline values in both groups from 7 or 9 min after the spinal anesthesia; however, there was no significant difference in HR between the groups (Fig. 3).
Fig. 3
Heart rate changes for 15 min after induction of spinal anesthesia. HR: heart rate, Group L: left fetal position group, Group R: right fetal position group. The boxes represent the median (black middle line) limited by the 25th (1Q) and 75th (3Q) percentiles. *P < 0.05 compared with the baseline value in group L. †P < 0.05 compared with the baseline value in group R.
APM_14_266_fig_3.tif

DISCUSSION

This study showed that supine hypotension occurred in 36 of the 67 enrolled patients. More than half of the healthy patients (54%) who underwent cesarean delivery under spinal anesthesia despite efforts to maintain the baseline hemodynamics showed hypotension before delivery. The rate of hypotension in group R (65%) and group L (40%) was not statistically different (P = 0.075).
Although there is a marked reduction of systemic vascular resistance at the moment of delivery, an increase in the cardiac output is enough to compensate the reduction; consequently, the mean arterial pressure remains stable in healthy patients [7]. In our study, arterial vasodilation induced by spinal anesthesia occurred in women with aortocaval compression by gravid uterus. However, shortage of cardiac output compensation may have caused a significant decrease in the SBP compared to baseline in group R from 2 min after the spinal anesthesia until delivery. In group L as well, SBP was significantly decreased compared to baseline from 2 min after the induction of spinal anesthesia; however, cardiac output compensation may have likely occurred at 13 min after the spinal anesthesia. However, there was no significant difference in the SBP between the groups. The amount of fluid infusion and blood loss also did not show significant difference between the groups.
The heart rate of patients in both groups was significantlydecreased compared with the baseline values. We attribute this to reflex bradycardia due to phenylephrine [8]. However, there was no significant difference between HR in the two groups. These results show that hemodynamic changes according to the fetal position do not differ until delivery.
The one-min Apgar score was significantly lower in group R than in group L (P = 0.032). Greater hemodynamic instability can affect uteroplacental blood flow [2], considering aortocaval compression by gravid uterus and additive spinal sympathetic blockade. However, it did not clinically differ between the two groups, as they showed the same Apgar score.
Administration of medications that increase the uterine tone is important to prevent postpartum hemorrhage; however, the usual first-line treatment, oxytocin, may put the woman in labor at risk of hypotension owing to its prominent vasodilatory effect [9,10]. Even under spinal anesthesia for cesarean delivery, patients may secrete endogenous oxytocin in response to the presence of the newborn baby [11]. Langesaeter et al. [12] reported that delivery may contribute to the circulatory changes, but the main effects are due to oxytocin. As the main focus of this study is on the hemodynamic effects of the fetus before delivery, studies on the hemodynamic effects of oxytocin will be conducted later.
In this study, patients were placed in the supine position after the induction of spinal anesthesia without 15° left tilt using right lumbar–pelvic wedge. According to a recent report, maternal supine position during planned cesarean delivery under spinal anesthesia in healthy term women does not impair neonatal acid–base status compared to the 15° left tilt position, when both a crystalloid co-load and a phenylephrine infusion are used to maintain the baseline maternal SBP [13]. Moreover, Sohn et al. reported that there was no difference in hypotension between lateral position and supine position during cesarean delivery following spinal anesthesia [14]. We designed this study for balancing the effect of fetal position, and the patients needed to be positioned without tilting. Healthy patients were enrolled and crystalloid co-load with phenylephrine infusion was followed to prevent supine hypotension. This study was limited by potential errors in the measurement of fetal position with Doppler ultrasound fetal monitor; further research to reduce such errors is warranted.
In conclusion, there was no difference according to fetal position in the number of patients who showed hypotension before delivery after spinal anesthesia. However, a significantly higher total phenylephrine dose for maintaining hemodynamic stability before delivery was required in group R. However, further research on the optimal phenylephrine dose is necessary to confirm this finding.

CONFLICTS OF INTEREST

No potential conflict of interest relevant to this article was reported.

REFERENCES

1. Howard BK, Goodson JH, Mengert WF. Supine hypotensive syndrome in late pregnancy. Obstet Gynecol. 1953; 1:371–7. PMID: 13055188.
2. Emmett RS, Cyna AM, Andrew M, Simmons SW. Techniques for preventing hypotension during spinal anaesthesia for caesarean section. Cochrane Database Syst Rev. 2001; 3:CD002251. DOI: 10.1002/14651858.CD002251. PMID: 11687021. PMCID: PMC6009735.
3. Ngan Kee WD. Prevention of maternal hypotension after regional anaesthesia for caesarean section. Curr Opin Anaesthesiol. 2010; 23:304–9. DOI: 10.1097/ACO.0b013e328337ffc6. PMID: 20173633.
4. Sharwood-Smith G, Drummond GB. Hypotension in obstetric spinal anaesthesia:a lesson from pre-eclampsia. Br J Anaesth. 2009; 102:291–4. DOI: 10.1093/bja/aep003. PMID: 19218369.
5. Kinsella SM, Lohmann G. Supine hypotensive syndrome. Obstet Gynecol. 1994; 83(5 Pt 1):774–88. PMID: 8164943.
6. Holmes F. The supine hypotensive syndrome 1960. Anaesthesia. 1995; 50:972–7. DOI: 10.1111/j.1365-2044.1995.tb05931.x. PMID: 8678255.
7. Tihtonen K, Kööbi T, Yli-Hankala A, Huhtala H, Uotila J. Maternal haemodynamics in pre-eclampsia compared with normal pregnancy during caesarean delivery. BJOG. 2006; 113:657–63. DOI: 10.1111/j.1471-0528.2006.00931.x. PMID: 16709208.
8. Stewart A, Fernando R, McDonald S, Hignett R, Jones T, Columb M. The dose-dependent effects of phenylephrine for elective cesarean delivery under spinal anesthesia. Anesth Analg. 2010; 111:1230–7. DOI: 10.1213/ANE.0b013e3181f2eae1. PMID: 20841418.
9. Weis FR Jr, Markello R, Mo B, Bochiechio P. Cardiovascular effects of oxytocin. Obstet Gynecol. 1975; 46:211–4. PMID: 1153152.
10. Langesaeter E, Rosseland LA, Stubhaug A. Hemodynamic effects of oxytocin during cesarean delivery. Int J Gynaecol Obstet. 2006; 95:46–7. DOI: 10.1016/j.ijgo.2006.05.032. PMID: 16920118.
11. Rosseland LA, Hauge TH, Grindheim G, Stubhaug A, Langesæter E. Changes in blood pressure and cardiac output during cesarean delivery:the effects of oxytocin and carbetocin compared with placebo. Anesthesiology. 2013; 119:541–51. DOI: 10.1097/ALN.0b013e31829416dd. PMID: 23598289.
12. Langesaeter E, Rosseland LA, Stubhaug A. Haemodynamic effects of repeated doses of oxytocin during Caesarean delivery in healthy parturients. Br J Anaesth. 2009; 103:260–2. DOI: 10.1093/bja/aep137. PMID: 19502285.
13. Lee AJ, Landau R, Mattingly JL, Meenan MM, Corradini B, Wang S, et al. Left lateral table tilt for elective cesarean delivery under spinal anesthesia has no effect on neonatal acid-base status:a randomized controlled trial. Anesthesiology. 2017; 127:241–9. DOI: 10.1097/ALN.0000000000001737. PMID: 28598894.
14. Sohn HM, Won DW, Oh AY, Hwang JW, Song IA. Effect of prolonged lateral position for 10-minutes following spinal anesthesia on hypotension and sensory blockade during cesarean delivery. Anesth Pain Med. 2016; 11:354–8. DOI: 10.17085/apm.2016.11.4.354.
TOOLS
Similar articles