Journal List > Arch Hand Microsurg > v.26(4) > 1148457

Lee, Park, Roh, Koh, Kim, Lee, and Koo: Usefulness of Color Doppler Ultrasonography for the Preoperative Evaluation of Thin Anterolateral Thigh Flap Perforators

Abstract

Purpose

The anterolateral thigh flap is commonly applied to various body sites for reconstruction. However, surgeons often struggle against unexpected locations and the nature of perforator vessels during surgery. Thus, this study aimed to assess the accuracy and usefulness of color Doppler ultrasonography as a preoperative tool for the perforator position and course of anterolateral thigh flaps.

Methods

A prospective study involving 77 anterolateral thigh flaps was conducted between March 2016 and February 2021. Among them, 37 perforators (group A) were detected using the preoperative color Doppler ultrasound, and the other 40 perforators (group B) were tested using a hand-held Doppler only. All patients in group A underwent color Doppler ultrasonography performed by a radiologist at our institution. The nature and course of the perforator vessels were recorded, and their precise locations were plotted in an orthonormal coordinate system.

Results

A total of 37 anterolateral thigh perforator flaps (group A) were successfully dissected. The median distance between the preoperative color Doppler ultrasonography and the real location during surgery of the perforators was 7.50 mm, which was statistically smaller than 10 mm (p<0.001). This preoperative ultrasound test also had a success rate of 94.6% to determine the nature of the perforators (musculocutaneous type vs. septocutaneous type).

Conclusion

Preoperative color Doppler ultrasonography provides a harmless, reliable, and accurate technique for visualizing the vascular anatomy of anterolateral thigh flaps. It has a high correlation with surgical findings, allowing surgeons to cope with variable vascular anatomy.

INTRODUCTION

The anterolateral thigh (ALT) flap has been one of the most frequently used flaps since it was first reported in 1984 [1]. The versatility of the ALT flap allowed its application to a variety of body sites such as the genitals, abdomen, pelvis, chest wall, extremities, head, and neck [2-7]. In addition, the ALT flap has many advantages: a reliably long pedicle, a good caliber, combination with cutaneous sensation, minimal donor site morbidity, and extendibility as a fasciocutaneous or musculocutaneous flap [8]. There might be an anatomic variability during most flap dissections, depending on the location of the donor site. Locating and dissecting the perforators could be difficult, particularly when raising a thin flap at the superficial fascial level. Reliable preoperative imaging evaluation would help anticipate the nature, location, and course of the perforators, improving surgical planning. Color Doppler ultrasonography (CDU) was recommended by Blondeel et al. [9] for planning other flaps such as the deep inferior epigastric perforator and the thoracodorsal artery perforator flap. Most recent studies have shown the reliability of CDU for detecting ALT perforators [10,11].
This study demonstrated CDU as a useful preoperative perforator assessment for successful surgical planning of ALT flaps by localizing the specific sites of perforators and predicting course and flow. Moreover, we explored the possibility of efficient surgery by decreasing the surgical duration.

MATERIALS AND METHODS

Between March 2016 and February 2021, 77 ALT flaps were harvested, and 37 perforator vessels (group A) were identified, of which 40 ALT flaps (group B) were attempted with hand-held Doppler assessment only. High-frequency CDU was conducted by a radiologist at our institution. Thirty-seven preoperatively observed perforators (group A) were found a day before flap surgery. An EPIQ 5 portable ultrasound machine with a 17-MHz linear probe (Koninklijke Philips N.V., Amsterdam, Netherlands) was used.
Before ultrasound scanning, the ABC system was set up on the thigh [8]. Once the leg was supinely positioned, the anterior superior iliac spine (ASIS) and superolateral corner of the patella (SLCP) were marked. The anterior superior iliac spine to superolateral corner of the patella (AP) line was drawn between the ASIS and SLCP. The midpoint of the AP line was marked, and area A had a 3-cm radius around the midpoint. Areas A and C were located 5 cm superior and 5 cm inferior to area B, respectively. In addition, areas A and C both had a 3-cm radius. Finally, an orthonormal coordinate system was defined; the x-axis was lined transversely at the midpoint, and the y-axis was lined along with the AP line.
The ultrasound scan began around the midpoint and progressed in a centrifugal manner until a perforator was detected (Fig. 1A). An upsurge through the vastus lateralis aponeurosis was marked on the skin. If the perforator ran transversely or obliquely, the route was marked. For precise measurement of the AB distance, which is the distance between the ultrasound location (A) and the surgical finding (B), point A was also recorded according to the orthonormal coordinate system. This procedure was repeated until the necessary number of perforators was determined. We also determined the ranking of observed perforator flows by Doppler flowmetry.
The ALT flap was undermined and elevated on the superficial fascia plane at the subcutaneous level (Fig. 2) in accordance with a previous study [12]. The point of emergence through the superficial fascia became point B and was recorded in the coordinate system. Point A, which was used for preoperative ultrasound assessment, and point B, which was observed during surgery, were recorded. Thus, the AB distance can be calculated using the following formula:
AB=(Bx-Ax)2+(By-Ay)2, with Ax, Ay, Bx, and By being the coordinates of A and B along the x and y axes, respectively.
We also evaluated the precision of the type of perforators (musculocutaneous or septocutaneous type) by comparing the findings of the preoperative ultrasound assessment with their nature during surgery. Among 77 ALT flaps, we analyzed the preoperative CDU would affect each operative time between group A with the preoperative CDU and group B with hand-held Doppler assessment only.
Statistical analyses were performed using IBM SPSS Statistics ver. 26 (IBM Corp., Armonk, NY, USA), and the statistical level of significance was set at p<0.05.
This study was approved by the Institutional Review Board of Gwangmyeong Sungae General Hospital (No. KIRB-2020-N-007) and performed in accordance with the principle of the Declaration of Helsinki. The patients gave written informed consent for publication of this study and accompanying images.

RESULTS

At least one perforator was detected in each thigh. All flaps were elevated successfully, and no surgical design modifications occurred during surgery. A total of 37 perforators (group A) from 34 patients who underwent preoperative CDU scans were analyzed (Table 1). The median AB distance was 7.50 mm (interquartile range, 3.75 mm), which is statistically smaller than 10 mm (p<0.001, Kolmogorov-Smirnov test). The success rate of the preoperative CDU test was 94.6% based on the detection of the nature of the perforators in 35 of the 37 cases. The ultrasound assessment had a sensitivity of 100%, a specificity of 80%, a positive predictive value of 93.8%, and a negative predictive value of 100% for the determination of musculocutaneous perforators. The coordinates and vascular types of all perforators during the surgery are shown in Fig. 3. The midpoint region (area B) had a total of 22 (59.5%), followed by areas A and C with 11 (39.7%) and 4 (10.8%) perforators, respectively.
Regarding the operating time, the average surgical duration of group A (with preoperative CDU) was 243.78 minutes (Table 1). On the other hand, the average surgical duration of group B (with hand-held Doppler only) was 258.65 minutes (Table 2). Although the average duration of group A was approximately 15 minutes shorter than that of group B, it was not statistically significant (p=0.355, Mann-Whitney test).

DISCUSSION

Computed tomographic angiography (CTA) and CDU are currently the most widely used imaging modalities for flap surgery. However, which preoperative modality is better between CTA and CDU remains controversial. Shen et al. [13] stated that CTA can provide three-dimensional information about the origin, direction, and caliber of perforators and is more accurate than the CDU when detecting ALT perforators. However, the critical problem is how to accurately transfer the preoperative information into real-time surgery; therefore, it requires a special image-guided navigation or printed templates. It is also clear that CTA cannot avoid the risk of radiation, disturbance due to metallic artifacts, and contrast media reactions [14].
On the other hand, CDU imaging correlated with the actual perforator location and course [15] and hemodynamic data from color Doppler flowmetry could help in selecting the appropriate perforators (Fig. 1B) [16]. Our study showed reliable results for the detection of ALT perforators using preoperative ultrasound scans. It had a 10-mm AB distance threshold, similar to a previous study, although ours was more accurate when determining the nature of the vessels (musculocutaneous vs. septocutaneous perforators) [10]. Two cases with septocutaneous vessels were misled for the musculocutaneous vessels. This suggests that it is difficult to differentiate musculocutaneous vessels around the septa from septocutaneous vessels between the septa.
While Debelmas et al. [10] labeled points A and B for the AB distance as the point of emergence through the deep fascia of the perforators, we defined these as the point of emergence through the superficial fascia. If the vessels ran transversely or obliquely near the subcutaneous layer, a marked discrepancy due to the gap in flap elevation can occur, which could reduce the possibility of misleadingness.
Through the CDU scan, we also demonstrated the distribution of perforators according to the ABC system (Table 3). Most perforators appeared in area B, correlating the course of the pedicle, descending branch of the lateral circumflex femoral artery, as in a previous study (Fig. 3) [17].
The present study has significant limitations. First, we compared the operating time between group A (with the CDU) and group B (without the CDU). However, the flap size varied, which affected the total surgical time. Additionally, it was not analyzed by dividing the flaps according to size. Second, variable factors such as the number of anastomosed arteries and veins were not limited. If more cases are accumulated, the study could be analyzed by flap size, anastomosed vessels, body mass index, etc. Indeed, elevation time would be more associated and a more correct factor for verifying the useful preoperative modality.

CONCLUSION

The CDU is an innocuous, reliable, and accurate modality for preoperative evaluation of ALT flaps because of its high correlation with surgical findings, enabling surgeons to make appropriate decisions. It also helps determine the precise origin, location, and course of perforator vessels through the superficial fascia and the vastus lateralis aponeurosis. Furthermore, CDU could potentially reduce the flap elevation time and the entire operating room time.

Notes

The authors have nothing to disclose.

REFERENCES

1. Song YG, Chen GZ, Song YL. The free thigh flap: a new free flap concept based on the septocutaneous artery. Br J Plast Surg. 1984; 37:149–59.
crossref
2. Yu P, Sanger JR, Matloub HS, Gosain A, Larson D. Anterolateral thigh fasciocutaneous island flaps in perineoscrotal reconstruction. Plast Reconstr Surg. 2002; 109:610–8.
crossref
3. Wei FC, Suominen S, Cheng MH, Celik N, Lai YL. Anterolateral thigh flap for postmastectomy breast reconstruction. Plast Reconstr Surg. 2002; 110:82–8.
crossref
4. Wei FC, Celik N, Chen HC, Cheng MH, Huang WC. Combined anterolateral thigh flap and vascularized fibula osteoseptocutaneous flap in reconstruction of extensive composite mandibular defects. Plast Reconstr Surg. 2002; 109:45–52.
crossref
5. Adani R, Tarallo L, Marcoccio I, Cipriani R, Gelati C, Innocenti M. Hand reconstruction using the thin anterolateral thigh flap. Plast Reconstr Surg. 2005; 116:467–77.
crossref
6. Yu P. Reinnervated anterolateral thigh flap for tongue reconstruction. Head Neck. 2004; 26:1038–44.
crossref
7. Yu P, Robb GL. Pharyngoesophageal reconstruction with the anterolateral thigh flap: a clinical and functional outcomes study. Plast Reconstr Surg. 2005; 116:1845–55.
crossref
8. Lin SJ, Rabie A, Yu P. Designing the anterolateral thigh flap without preoperative Doppler or imaging. J Reconstr Microsurg. 2010; 26:67–72.
crossref
9. Blondeel PN, Beyens G, Verhaeghe R, et al. Doppler flowmetry in the planning of perforator flaps. Br J Plast Surg. 1998; 51:202–9.
crossref
10. Debelmas A, Camuzard O, Aguilar P, Qassemyar Q. Reliability of color Doppler ultrasound imaging for the assessment of anterolateral thigh flap perforators: a prospective study of 30 perforators. Plast Reconstr Surg. 2018; 141:762–6.
11. Ibrahim RM, Gunnarsson GL, Akram J, Sørensen JA, Thomsen JB. Color Doppler ultrasonography targeted reconstruction using pedicled perforator flaps: a systematic review and meta-analysis. Eur J Plast Surg. 2018; 41:495–504.
12. Hong JP, Chung IW. The superficial fascia as a new plane of elevation for anterolateral thigh flaps. Ann Plast Surg. 2013; 70:192–5.
crossref
13. Shen Y, Huang J, Dong MJ, Li J, Ye WM, Sun J. Application of computed tomography angiography mapping and located template for accurate location of perforator in head and neck reconstruction with anterolateral thigh perforator flap. Plast Reconstr Surg. 2016; 137:1875–85.
crossref
14. González Martínez J, Torres Pérez A, Gijón Vega M, Nuñez-Villaveiran T. Preoperative vascular planning of free flaps: comparative study of computed tomographic angiography, color Doppler ultrasonography, and hand-held Doppler. Plast Reconstr Surg. 2020; 146:227–37.
crossref
15. Ensat F, Babl M, Conz C, et al. The efficacy of color duplex sonography in preoperative assessment of anterolateral thigh flap. Microsurgery. 2012; 32:605–10.
crossref
16. Feng S, Min P, Grassetti L, et al. A prospective head-to-head comparison of color Doppler ultrasound and computed tomographic angiography in the preoperative planning of lower extremity perforator flaps. Plast Reconstr Surg. 2016; 137:335–47.
crossref
17. Malhotra K, Lian TS, Chakradeo V. Vascular anatomy of anterolateral thigh flap. Laryngoscope. 2008; 118:589–92.
crossref

Fig. 1.
Color Doppler ultrasound preoperative assessment (perforator 33). (A) The location and course of the perforator surges through the superficial fascia (left arrow) from the vastus lateralis aponeurosis (deep fascia, right arrow). (B) The flow of the perforator is measured using the color Doppler flowmeter.
ahm-21-0105f1.tif
Fig. 2.
Intraoperative photographs of harvesting a thin anterolateral thigh (ALT) flap (perforator 33). (A) The ALT flap is harvesting on the plane of the superficial fascia, being careful for the predicted perforator (arrow). (B) The perforator (arrow) is saved, and recorded in the orthonormal coordinate system. The patient provided written informed consent for the publication and the use of his images.
ahm-21-0105f2.tif
Fig. 3.
Overall distribution of perforators during surgery. A total of 37 perforators during surgery were plotted in the orthonormal coordinate system. Area B has the most perforators (22), followed by areas A and C. Blue, musculocutaneous type; pink, septocutaneous type.
ahm-21-0105f3.tif
Table 1.
Results for the 37 perforators (group A, with the color Doppler ultrasonography)
Perforator No. Sex/age (yr) Preoperative prediction Surgical finding AB distance (mm) Flap size (cm) Artery Vein Operating time (min)
1 Female/52 M I 7.5 6.0×15.0 1 1 250
2 Male/59 M I 3.7 6.0×15.0 1 1 145
3 Male/41 M I 7.5 7.0×15.0 1 2 265
4 Male/57 S I 11.2 5.0×5.0 1 2 210
5 Female/64 M I 0 3.0×8.0 1 2 230
6 Male/19 M I 7.5 7.0×15.0 1 2 205
7 Male/44 M I 14.0 8.0×18.0 1 1 315
8 Male/62 M I 11.2 7.0×12.0 1 2 170
9 Male/58 M I 7.5 6.0×12.0 1 2 310
10 Male/45 M I 7.5 8.0×15.0 1 1 370
11 Male/29 S I 10.0 9.0×22.0 1 2 300
12 Male/30 M I 0 5.0×14.0 1 2 300
13 Male/54 M I 7.5 3.5×9.0 1 1 120
14 Male/54 M I 10.0 4.5×9.5 1 1 135
15 Male/54 M I 22.4 4.0×5.0 1 1 120
16 Male/54 M I 11.2 4.0×10.0 1 1 120
17 Male/32 M S 10.0 5.0×12.0 1 2 355
18 Male/50 S I 11.2 6.0×15.0 1 2 345
19 Male/61 M I 7.5 5.0×12.0 1 2 275
20 Female/65 M I 14.0 4.0×9.0 1 1 270
21 Female/22 M I 11.2 5.0×8.0 1 1 200
22 Male/72 M I 7.5 6.0×15.0 1 2 290
23 Male/63 S I 5.0 6.0×15.0 1 2 215
24 Male/53 M S 7.5 4.0×7.0 1 2 300
25 Male/57 M I 7.5 5.0×10.0 1 1 225
26 Male/67 S I 10.0 7.0×17.0 1 2 305
27 Male/60 M I 14.0 4.0×11.0 1 1 200
28 Male/32 S I 11.2 7.0×7.0 1 1 120
29 Male/62 M I 7.5 4.0×9.0 1 2 300
30 Male/30 M I 14.0 4.0×15.0 1 1 220
31 Male/59 S I 7.5 8.0×20.0 1 2 260
32 Male/66 M I 10.0 8.0×18.0 1 2 310
33 Male/41 M I 14.0 8.0×15.0 1 1 235
34 Male/56 M I 7.5 7.0×20.0 1 1 300
35 Male/44 S I 10.0 7.0×17.0 1 2 330
36 Male/51 M I 7.5 6.0×10.0 1 2 235
37 Male/46 M I 0 5.0×15.0 1 1 165
Median AB distance 7.5 Average operating time 243.78

AB distance, distance between the ultrasound location (A) and the surgical finding (B); M, musculocutaneous perforator; S, septocutaneous perforator; I, identical surgical finding.

Table 2.
Results for group B (without the color Doppler ultrasonography)
Perforator No. Sex/age (yr) Flap size (cm)  Artery Vein Operating time (min)
1 Male/50 7.0×15.0 1 2 275
2 Female/30 5.0×18.0 1 2 315
3 Female/21 3.0×7.0 1 1 315
4 Male/55 6.0×18.0 1 2 300
5 Male/45 5.0×12.0 1 2 260
6 Male/52 7.0×18.0 1 1 380
7 Male/69 6.0×15.0 1 1 295
8 Male/54 5.0×13.0 1 2 290
9 Female/48 5.0×12.0 1 1 195
10 Male/50 10.0×17.0 2 1 290
11 Male/57 7.0×13.0 1 2 215
12 Male/57 4.0×7.0 1 1 175
13 Male/58 7.0×18.0 1 2 305
14 Male/45 8.5×17.0 1 2 285
15 Male/64 7.0×13.0 2 3 290
16 Male/52 3.0×4.0 1 2 190
17 Male/27 10.0×19.0 1 2 295
18 Male/21 3.0×10.0 1 2 175
19 Male/40 5.0×14.0 1 3 275
20 Male/42 6.5×15.0 1 1 285
21 Male/47 3.0×7.0 1 1 300
22 Male/58 6.0×13.0 2 2 255
23 Male/55 3.0×11.5 1 1 175
24 Male34 6.0×15.0 1 1 225
25 Female/57 5.0×8.0 1 1 175
26 Male/56 3.5×9.0 1 1 265
27 Male/29 7.0×15.0 1 2 375
28 Male/29 5.0×10.0 1 1 295
29 Male/47 5.0×10.0 1 2 250
30 Male/41 6.0×8.0 1 1 180
31 Male/34 7.0×15.0 2 2 295
32 Male/21 5.0×9.5 1 1 165
33 Male/59 4.0×10.0 1 2 200
34 Male/41 3.0×10.0 1 2 190
35 Male/55 4.5×12.0 1 2 255
36 Male/36 10.0×15.0 1 2 265
37 Male/33 5.0×15.0 1 2 300
38 Male/55 7.0×15.0 1 2 275
39 Male/57 5.0×5.0 1 2 210
40 Male/57 7.0×14.0 1 1 235
Average operating time 258.65
Table 3.
Perforator locations and characteristics
Characteristic Perforator (n=37)
A B C
Presence 11 (29.7%) 22 (59.5%) 4 (10.8%)
Musculocutaneous type 6 18 3
Septocutaneous type 5 4 1
Average x axis (mm) –0.4 (–20 to +15) +0.7 (–20 to +20) +10 (–20 to +15)
Average y axis (mm) +36.7 (+30 to +50) +4.1 (–20 to +20) –40 (–50 to –30)
TOOLS