Journal List > Korean J Orthod > v.51(3) > 1146852

Giudice, Rustico, Longo, Oteri, Papadopoulos, and Nucera: Complications reported with the use of orthodontic miniscrews: A systematic review

Abstract

Objective

The aim of this systematic review was to evaluate the complications and side effects associated with the clinical use of orthodontic miniscrews by systematically reviewing the best available evidence.

Methods

A survey of articles published up to March 2020 investigating the complications associated with miniscrew insertion, in both the maxilla and mandible, was performed using 7 electronic databases. Clinical studies, case reports, and case series reporting complications associated with the use of orthodontic miniscrew implants were included. Two authors independently performed study selection, data extraction, and risk-of-bias assessment.

Results

The database survey yielded 24 articles. The risk-of-bias assessment revealed low methodological quality for the included studies. The most frequent adverse event reported was root injury with an associated periradicular lesion, vitality loss, pink discoloration of the tooth, and transitory loss of pulp sensitivity. Chronic inflammation of the soft tissue surrounding the miniscrew with mucosal overgrowth was also reported. The other adverse events reported were lesion of the buccal mucosa at the insertion site, soft-tissue necrosis, and perforation of the floor of the nasal cavity and maxillary sinus. Adverse events were also reported after miniscrew removal and included secondary bleeding, miniscrew fracture, scars, and exostosis.

Conclusions

These findings highlight the need for clinicians to preliminarily assess generic and specific insertion site complications and side effects.

INTRODUCTION

Anchorage management is a key factor for success in clinical orthodontics, as it is essential to maximize desired tooth movements and mitigate unwanted forces.1 Many anchorage devices, both intraoral and extraoral, have been proposed and used for more than a century.1 Orthodontic implants or temporary anchorage devices (TADs) are a compliance-free alternative to conventional anchorage systems. Current literature suggests that TADs can provide more stable anchorage than do traditional methods.2 Skeletal anchorage, in the form of implants or miniscrews fixed to the bone, can be used to enhance support to the reactive unit (indirect anchorage) or to fix the anchor unit (direct anchorage).3 Nowadays, TADs are widely used in daily orthodontic practice to increase the effectiveness of dental movement (protraction, retraction, intrusion, or uprighting) or the effectiveness of orthopedic appliances, in the form of hybrid or bone-borne designs.4-6 Nevertheless, the clinical use of miniscrews is associated with potential side effects (i.e., unwanted effects that are generally predictable and expected) and complications (i.e., unwanted and unexpected events due to treatment, and recognized as events that can happen), which can occur during their insertion, use, or removal.7
Many studies have evaluated the clinical applications and effectiveness of orthodontic miniscrews, but few have evaluated the side effects and complications related to their clinical use. Moreover, most of these studies in the literature are case reports, and studies covering and discussing the documented side effects and complications related to the usage of TADs are scarce.
Therefore, the aim of this systematic review was to evaluate the side effects and complications associated with the clinical use of orthodontic miniscrews by systematically reviewing the literature for the best available evidence.

MATERIALS AND METHODS

Protocol and registration

The present systematic review was performed according to the guidelines provided by the Cochrane Handbook for Systematic Reviews of Interventions (version 5.1.0) and was reported according to the PRISMA statement.8,9 The protocol of this systematic review was preliminarily registered on PROSPERO (ID: CRD42020142774). Two authors independently carried out study selection, data collection, and risk-of-bias assessment. Any disagreement was resolved by discussion with a third author. The level of agreement between the two reviewers was assessed using Cohen kappa statistics.

Information sources and search

A survey of articles published up to March 2020 about the complications associated with miniscrew insertion in both the maxilla and mandible was performed using 7 different electronic databases (Table 1). A specific search strategy was developed for each database, as shown in Table 1. The research strategy was not restricted by language, publication year, or status, and articles in foreign languages were translated when required. The reference lists of the articles eligible for inclusion were also manually reviewed. Previous systematic reviews and meta-analyses on this topic were also identified and their reference lists were scanned to identify additional studies.7,10,11

Study selection

Duplicated reports were preliminarily excluded. All retrieved records were screened on the basis of titles and abstracts, and the full text of the remaining articles was assessed for eligibility before inclusion in the final analysis. Studies were considered eligible if they met the inclusion criteria, which were reported according to the PICO format (Table 2).

Data extraction and management

A data extraction form was developed to collect the characteristics of (study design, sample size, age, sex, insertion site, type of miniscrews, type of complication, observation period, and surgical insertion procedure) and outcomes from the included studies. The primary outcomes were the complications, which were unwanted and unexpected events due to treatment, generally related to improper use of orthodontic miniscrews, and could lead to permanent biological damage. In contrast, the secondary outcomes were side effects, which could occur regardless of how miniscrews were used and generally did not lead to permanent biological damage.

Risk-of-bias assessment

The risk-of-bias of the included studies was assessed using the Newcastle-Ottawa Scale (NOS), as recommended by the Cochrane Collaboration.10 The NOS consists of 8 multiple-choice questions that address subject selection (4 questions), comparability (1 question), and outcome assessment (3 questions). High-quality responses would be awarded up to 9 points (the comparability question earns up to 2 points). No risk-of-bias assessment was planned for case reports and case series.

RESULTS

Study selection

Among the 1,980 initially identified articles, 1,487 remained after the removal of duplicates. On the basis of an analysis of the titles and abstracts, another 1,424 articles were excluded. Among the remaining 63 articles, 39 were further excluded after evaluating their full texts; nevertheless, 3 of those studies were meta-analyses, and hence, their reference lists were scanned to identify additional studies.7,11,12 Therefore, 24 studies were finally selected for the qualitative and quantitative synthesis. Figure 1 shows the flow diagram for the selection of studies. Table 3 lists the excluded articles together with the reason for exclusion.

Study characteristics

The characteristics of the 24 studies included in the systematic review are summarized in Table 4. All studies reported side effects and complications associated with the use of orthodontic miniscrews. The studies, as summarized in Figure 2, were identified as follows: 11 case reports,13-23 8 retrospective longitudinal studies,24-31 3 prospective controlled trials,32-34 1 preliminary study,35 and 1 case series.36 All studies were conducted in a university setting and included both male and female participants. The reported average age of the patients ranged from 11 to 52 years old. Self-drilling titanium orthodontic miniscrews were used in 7 different studies,15,23,26,28-30,32 whereas non-self-drilling screws were used in 4 studies.19,24,25,27 The other studies did not specify the type of miniscrew inserted. The miniscrews used among the studies differed in terms of manufacturer and dimensions (such as diameter and length of the miniscrew). The diameters ranged from 1.2 mm13,14,21 to 3 mm,35 and the length ranged from 2.3 mm35 to 14 mm.28
All the miniscrews were surgically inserted according to the protocol suggested by the respective manufacturer. According to each orthodontic treatment plan, the miniscrews were positioned both in the maxilla and in the mandible, in the interradicular area,13,15,18,19,21-24,32,33,36 palatal zone,16,17,25,26,31 infrazygomatic crest,28,36 ascending ramus,26 or buccal shelf.20,26,29
The adverse events associated with the use of orthodontic miniscrews are summarized in Tables 5 and 6, after dividing them into complications and side effects, and reported separately with the relative information about the insertion site. Seven studies reported root perforation,18,19,21,23 with an associated periradicular lesion,16 loss of tooth vitality,27 pink discoloration of the crown, and transitory loss of vitality.22 Three studies reported contact of the miniscrew with the root of the adjacent tooth.21,33,34 Three studies also reported the perforation of the maxillary sinus,28,32,36 and one study reported the perforation of the nasal cavity floor.25
Some complications occurred immediately after the removal of the miniscrew, such as secondary bleeding,25 fracture of the miniscrew,21,25,26 or loss of bone tissue around the insertion site.17 However, other complications occurred later, such as scars15,29 or exostoses.13 Other complications described were inflammatory lesions,26,30,31,35 necrosis of the buccal or palatal mucosa at the insertion site level,25 or traumatic sores on the soft tissue in direct contact with the miniscrew.14,20 The patient’s pain, during and after the insertion of the miniscrews, was reported in two different studies.14,25

Risk-of-bias assessment

The risk-of-bias of the 8 included retrospective studies was assessed using the NOS.24-31 The scores of the studies ranged from 3 to 5 stars, as reported in Table 7. The interreviewer agreements for study selection, data extraction, and risk-of-bias assessment were suitable, with kappa values of 0.931, 0.988, and 0.943, respectively.

DISCUSSION

To the best of our knowledge, this is the first systematic review that specifically investigated the current literature on the complications associated with the usage of orthodontic miniscrews. However, a meta-analysis could not be performed because of the high heterogeneity and differences in design among the selected studies.
According to the results of this systematic review, the insertion of miniscrews as TADs can be characterized by the onset of immediate or delayed complications associated with both the soft and hard tissues.
One of the most commonly reported complications was the contact of the miniscrews with the root of the tooth adjacent to the insertion site. This undesired event had a greater incidence in the interradicular insertion sites, mainly in the posterior region of both the arches, with a similar incidence in both the maxilla and the mandible.
Miniscrew–tooth contact can contribute to the loss of the miniscrew,37,38 or can determine tooth vitality loss.27 Miniscrews placed in a narrow space, such as the interradicular space, can cause iatrogenic damage to the root and the periodontium, and the extent of damage may vary depending on the extent of penetration of the miniscrew. However, if the miniscrew invades the space limits of the periodontal ligament, its prompt removal will promote rapid tissue healing without further complications.34,39,40
If the cementum is mechanically damaged, multinucleated cells will colonize the denuded dentin in contact with the miniscrew, resulting in root resorption. If the damage is limited to the surface area of the root, it can be replaced by cementum-like tissue within 2–3 weeks after miniscrew removal or even without removal.41,42 Root injury that affects the pulp tissue can cause periodontal ligament destruction and tooth vitality loss. Moreover, this adverse event will necessitate not only endodontic treatment of the injured tooth but also surgical repair of the root.18 The interradicular placement of the miniscrews also necessitates an appropriate radiographic evaluation to guide the clinician in determining the safest site for miniscrew insertion.43,44
Therefore, clinicians should be aware that the greatest amount of interradicular bone in the buccal maxillary region is between the second premolar and the first molar, 5–8 mm from the alveolar ridge.45,46 In addition, in the mandibular buccal region, the greatest amount of bone is between the second premolar and the second molar. Thus, these regions are the most favorable ones for the buccal intraalveolar placement of orthodontic miniscrews. However, during the insertion procedure in the posterior region, operators have a strong tendency to change the insertion angle by bringing the handpiece toward them, and this maneuver can increase the risk of root injury and miniscrew fracture.47
During the insertion procedure, if the miniscrew contacts the periodontal ligament, the patient may experience increased sensitivity even under topical anesthesia.44,48 In case of contact with dental roots, the miniscrew may stop or require greater insertion force.48 Increased torsional stress during the insertion procedure could lead to flexion or fracture of the miniscrew.21,26 Miniscrew fracture often occurs in the cervical part, because during the insertion procedure, mechanical stress is concentrated at that point.49 Self-drilling miniscrews are associated with increased torque during placement.50,51 This is beneficial for primary stability but could increase the risk of miniscrew fracture upon insertion, especially in high-density bone.52
In the analyzed studies, the palatal site was less affected by complications. Taken together with the current literature, our findings suggest that the anterior region of the palate is the most appropriate insertion site owing to the high success rate and ideal anatomical characteristics.53-56 However, unintentional injuries to the roots of the anterior teeth were reported in 2 studies.16,27 In these studies, root damage occurred because of improper positioning, with the placement of the miniscrews at the second palatine rugae or ahead. In this regard, previous evidence suggests that the miniscrews should be placed posteriorly at the level of or behind the third palatine rugae.57
Several researchers have recommended the infrazygomatic crest as a useful site for miniscrew insertion, since this area provides two cortical plates (i.e., the buccal cortical and maxillary sinus floor) that can ensure great primary stability.58 However, the main complication related to the use of the infrazygomatic crest or the posterior region of the maxilla as a miniscrew insertion site is the perforation of the maxillary sinus. This complication was reported in 3 studies.28,32,38 Jia et al.28 reported the perforation of the maxillary sinus in 78.3% of the miniscrews inserted in the infrazygomatic crest. Motoyoshi et al.32 reported the perforation of the maxillary sinus in 9.8% of the miniscrews inserted in the posterior region of the maxilla. However, maxillary sinus perforations ≤ 1.5 mm in depth are unlikely to affect screw stability.59 Even if perforation occurs, interruption of orthodontic treatment and miniscrew removal are not needed. This is because small, uncomplicated perforations of the maxillary sinus by miniscrews may heal spontaneously.60
One of the most frequently reported complications in the present review was related to the soft tissues surrounding the implant. Miniscrew placement can stimulate the surrounding soft tissues and evoke tissue inflammation, small infections, and periimplantitis, especially when placed through the non-keratinized or mobile gingiva. Tissue overgrowth, defined as a partial or total covering of the implant head by the surrounding soft tissues, was reported by Ziebura et al.31 as the most common complication associated with miniscrews placed on the palatal site. To avoid this, several authors have proposed covering the miniscrew head with a healing abutment, wax pellet, or large separation elastic. For the same reasons and to avoid traumatic injuries caused by the miniscrews, Al-Kharsa and Masoud14 proposed covering the head of the miniscrew with a composite resin. Two studies reported soft-tissue scars after miniscrew removal.15,29 The removal procedure is almost atraumatic but leaves a small, transient, full-thickness wound that heals via secondary intention. Intrinsic factors, such as the patient’s age and flat gingival biotype, or miniscrew-related factors, such as the insertion of the miniscrews in the attached gingiva or the mucogingival junction, especially at the maxillary buccal region, can represent risk factors for scar development. Therefore, the application of appropriate postoperative/removal care may be necessary to promote favorable healing.

CONCLUSION

The insertion of orthodontic miniscrews is a widely described and relatively safe therapeutic procedure; however, it is not free from possible complications and side effects.
The most frequently reported complication was the occurrence of lesions at the roots during miniscrew interradicular insertion. The main side effects found in this review were pain, soft- and hard-tissue inflammation, hypertrophy of the gingival tissues surrounding the miniscrew, and perforation of the maxillary sinus and nasal cavity walls.
Clinicians should preliminarily assess generic and specific insertion site complications and side effects.
There is a lack of clinical studies that specifically evaluate the complications and side effects associated with miniscrew insertion. Future studies are needed to address this scarcity of evidence.

Notes

CONFLICTS OF INTEREST

No potential conflict of interest relevant to this article was reported.

REFERENCES

1. Proffit WR, Fields HW, Larson BE, Sarver DM. 2019. Contemporary orthodontics. Elsevier;Philadelphia:
2. Antoszewska-Smith J, Sarul M, Łyczek J, Konopka T, Kawala B. 2017; Effectiveness of orthodontic miniscrew implants in anchorage reinforcement during en-masse retraction: a systematic review and meta-analysis. Am J Orthod Dentofacial Orthop. 151:440–55. DOI: 10.1016/j.ajodo.2016.08.029. PMID: 28257728.
crossref pmid
3. Papadopoulos MA, Tarawneh F. 2007; The use of miniscrew implants for temporary skeletal anchorage in orthodontics: a comprehensive review. Oral Surg Oral Med Oral Pathol Oral Radiol Endod. 103:e6–15. DOI: 10.1016/j.tripleo.2006.11.022. PMID: 17317235.
crossref
4. Jones JP, Elnagar MH, Perez DE. 2020; Temporary skeletal anchorage techniques. Oral Maxillofac Surg Clin North Am. 32:27–37. DOI: 10.1016/j.coms.2019.08.003. PMID: 31685345.
crossref pmid
5. Papadopoulos MA, Papageorgiou SN, Zogakis IP. 2011; Clinical effectiveness of orthodontic miniscrew implants: a meta-analysis. J Dent Res. 90:969–76. DOI: 10.1177/0022034511409236. PMID: 21593250.
crossref
6. Lin L, Ahn HW, Kim SJ, Moon SC, Kim SH, Nelson G. 2015; Tooth-borne vs bone-borne rapid maxillary expanders in late adolescence. Angle Orthod. 85:253–62. DOI: 10.2319/030514-156.1. PMID: 25490552.
crossref pmid
7. Papageorgiou SN, Zogakis IP, Papadopoulos MA. 2012; Failure rates and associated risk factors of orthodontic miniscrew implants: a meta-analysis. Am J Orthod Dentofacial Orthop. 142:577–95.e7. DOI: 10.1016/j.ajodo.2012.05.016. PMID: 23116500.
crossref pmid
8. Higgins JPT, Green S. 2011. Cochrane handbook for systematic reviews of interventions version 5.1.0 [updated March 2011]. The Cochrane Collaboration;London:
9. Liberati A, Altman DG, Tetzlaff J, Mulrow C, Gøtzsche PC, Ioannidis JP, et al. 2009; The PRISMA statement for reporting systematic reviews and meta-analyses of studies that evaluate health care interventions: explanation and elaboration. J Clin Epidemiol. 62:e1–34. DOI: 10.1016/j.jclinepi.2009.06.006. PMID: 19631507.
crossref
10. Wells GA, Shea B, O'Connell D, Peterson J, Welch V, Losos M, et al. 2013. The Newcastle-Ottawa Scale (NOS) for assessing the quality of nonrandomised studies in meta-analyses. University of Ottawa;Ottawa:
11. Alharbi F, Almuzian M, Bearn D. 2018; Miniscrews failure rate in orthodontics: systematic review and meta-analysis. Eur J Orthod. 40:519–30. DOI: 10.1093/ejo/cjx093. PMID: 29315365.
crossref pmid
12. Reynders R, Ronchi L, Bipat S. 2009; Mini-implants in orthodontics: a systematic review of the literature. Am J Orthod Dentofacial Orthop. 135:564.e1–19. discussion 564–5. DOI: 10.1016/j.ajodo.2008.09.026. PMID: 19409331.
crossref
13. Agrawal N, Kallury A, Agrawal K, Nair PP. 2013; Alveolar bone exostoses subsequent to orthodontic implant placement. BMJ Case Rep. 2013:bcr2012007951. DOI: 10.1136/bcr-2012-007951. PMID: 23355580. PMCID: PMC3604206.
crossref
14. Al-Kharsa SS, Masoud AI. 2017; A proposed method for covering a mini-screw head while maintaining space for ligation. Int J Orthod Milwaukee. 28:65–6. PMID: 29990405.
15. Choi YJ, Lee DW, Kim KH, Chung CJ. 2015; Scar formation and revision after the removal of orthodontic miniscrews. Korean J Orthod. 45:146–50. DOI: 10.4041/kjod.2015.45.3.146. PMID: 26023543. PMCID: PMC4446376.
crossref pmid pmc
16. Er K, Bayram M, Taşdemir T. 2011; Root canal treatment of a periradicular lesion caused by unintentional root damage after orthodontic miniscrew placement: a case report. Int Endod J. 44:1170–5. DOI: 10.1111/j.1365-2591.2011.01933.x. PMID: 21851367.
crossref pmid
17. Ghislanzoni LH, Berardinelli F, Ludwig B, Lucchese A. 2016; Considerations involved in placing miniscrews near the nasopalatine bundle. J Clin Orthod. 50:321–8. PMID: 27323275.
pmid
18. Hwang YC, Hwang HS. 2011; Surgical repair of root perforation caused by an orthodontic miniscrew implant. Am J Orthod Dentofacial Orthop. 139:407–11. DOI: 10.1016/j.ajodo.2008.11.032. PMID: 21392697.
crossref pmid
19. Lee JY, Kim PS, Choi C, Kim KB. 2016; Root repair and regeneration after miniscrew root damage. J World Fed Orthod. 5:70–8. DOI: 10.1016/j.ejwf.2016.02.005.
crossref
20. Marquezan M, de Freitas AO, Nojima LI. 2012; Miniscrew covering: an alternative to prevent traumatic lesions. Am J Orthod Dentofacial Orthop. 141:242–4. DOI: 10.1016/j.ajodo.2010.05.027. PMID: 22284292.
crossref pmid
21. McCabe P, Kavanagh C. 2012; Root perforation associated with the use of a miniscrew implant used for orthodontic anchorage: a case report. Int Endod J. 45:678–88. DOI: 10.1111/j.1365-2591.2012.02022.x. PMID: 22309739.
crossref pmid
22. Qin YJ, Zhang GD, Zhang Y, Ping YF, Zhao CY. 2016; Natural reversal of tooth discoloration and pulpal response to testing following removal of a miniscrew implant for orthodontic anchorage: a case report. Int Endod J. 49:402–9. DOI: 10.1111/iej.12459. PMID: 25877019.
crossref pmid
23. Lim G, Kim KD, Park W, Jung BY, Pang NS. 2013; Endodontic and surgical treatment of root damage caused by orthodontic miniscrew placement. J Endod. 39:1073–7. DOI: 10.1016/j.joen.2013.04.037. PMID: 23880281.
crossref pmid
24. Chen CM, Chang CS, Tseng YC, Hsu KR, Lee KT, Lee HE. 2011; The perception of pain following interdental microimplant treatment for skeletal anchorage: a retrospective study. Odontology. 99:88–91. DOI: 10.1007/s10266-010-0152-1. PMID: 21271332.
crossref pmid
25. Fäh R, Schätzle M. 2014; Complications and adverse patient reactions associated with the surgical insertion and removal of palatal implants: a retrospective study. Clin Oral Implants Res. 25:653–8. DOI: 10.1111/clr.12152. PMID: 23551587.
crossref pmid
26. Gurdan Z, Szalma J. 2018; Evaluation of the success and complication rates of self-drilling orthodontic mini-implants. Niger J Clin Pract. 21:546–52. DOI: 10.4103/njcp.njcp_105_17. PMID: 29735852.
crossref pmid
27. Hourfar J, Bister D, Lisson JA, Ludwig B. 2017; Incidence of pulp sensibility loss of anterior teeth after paramedian insertion of orthodontic mini-implants in the anterior maxilla. Head Face Med. 13:1. DOI: 10.1186/s13005-016-0134-9. PMID: 28061791. PMCID: PMC5217250.
crossref pmid pmc
28. Jia X, Chen X, Huang X. 2018; Influence of orthodontic mini-implant penetration of the maxillary sinus in the infrazygomatic crest region. Am J Orthod Dentofacial Orthop. 153:656–61. DOI: 10.1016/j.ajodo.2017.08.021. PMID: 29706213.
crossref pmid
29. Jung SA, Choi YJ, Lee DW, Kim KH, Chung CJ. 2015; Cross-sectional evaluation of the prevalence and factors associated with soft tissue scarring after the removal of miniscrews. Angle Orthod. 85:420–6. DOI: 10.2319/101813-772.1. PMID: 25153264.
crossref
30. Takaki T, Tamura N, Yamamoto M, Takano N, Shibahara T, Yasumura T, et al. 2010; Clinical study of temporary anchorage devices for orthodontic treatment--stability of micro/mini-screws and mini-plates: experience with 455 cases. Bull Tokyo Dent Coll. 51:151–63. DOI: 10.2209/tdcpublication.51.151. PMID: 20877162.
pmid
31. Ziebura T, Flieger S, Wiechmann D. 2012; Mini-implants in the palatal slope--a retrospective analysis of implant survival and tissue reaction. Head Face Med. 8:32. DOI: 10.1186/1746-160X-8-32. PMID: 23157849. PMCID: PMC3546431.
crossref pmid pmc
32. Motoyoshi M, Sanuki-Suzuki R, Uchida Y, Saiki A, Shimizu N. 2015; Maxillary sinus perforation by orthodontic anchor screws. J Oral Sci. 57:95–100. DOI: 10.2334/josnusd.57.95. PMID: 26062857.
crossref pmid
33. Shinohara A, Motoyoshi M, Uchida Y, Shimizu N. 2013; Root proximity and inclination of orthodontic mini-implants after placement: cone-beam computed tomography evaluation. Am J Orthod Dentofacial Orthop. 144:50–6. DOI: 10.1016/j.ajodo.2013.02.021. PMID: 23810045.
crossref pmid
34. Fabbroni G, Aabed S, Mizen K, Starr DG. 2004; Transalveolar screws and the incidence of dental damage: a prospective study. Int J Oral Maxillofac Surg. 33:442–6. DOI: 10.1016/j.ijom.2003.10.014. PMID: 15183406.
crossref pmid
35. Wang Z, Zhang D, Liu Y, Zhao Z. 2010; Buccal mucosal lesions caused by the interradicular miniscrew: a preliminary report. Int J Oral Maxillofac Implants. 25:1183–8. PMID: 21197496.
pmid
36. Gracco A, Tracey S, Baciliero U. 2010; Miniscrew insertion and the maxillary sinus: an endoscopic evaluation. J Clin Orthod. 44:439–43. PMID: 21038797.
pmid
37. Nucera R, Bellocchio AM, Oteri G, Farah AJ, Rosalia L, Giancarlo C, et al. 2019; Bone and cortical bone characteristics of mandibular retromolar trigone and anterior ramus region for miniscrew insertion in adults. Am J Orthod Dentofacial Orthop. 155:330–8. DOI: 10.1016/j.ajodo.2018.04.025. PMID: 30826035.
crossref pmid
38. Nucera R, Lo Giudice A, Bellocchio AM, Spinuzza P, Caprioglio A, Perillo L, et al. 2017; Bone and cortical bone thickness of mandibular buccal shelf for mini-screw insertion in adults. Angle Orthod. 87:745–51. DOI: 10.2319/011117-34.1. PMID: 28598220.
crossref pmid
39. Liou EJ, Pai BC, Lin JC. 2004; Do miniscrews remain stationary under orthodontic forces? Am J Orthod Dentofacial Orthop. 126:42–7. DOI: 10.1016/j.ajodo.2003.06.018. PMID: 15224057.
crossref pmid
40. Kuroda S, Yamada K, Deguchi T, Hashimoto T, Kyung HM, Takano-Yamamoto T. 2007; Root proximity is a major factor for screw failure in orthodontic anchorage. Am J Orthod Dentofacial Orthop. 131(4 Suppl):S68–73. DOI: 10.1016/j.ajodo.2006.06.017. PMID: 17448389.
crossref
41. Tronstad L. 1988; Root resorption--etiology, terminology and clinical manifestations. Endod Dent Traumatol. 4:241–52. DOI: 10.1111/j.1600-9657.1988.tb00642.x. PMID: 3078294.
pmid
42. Renjen R, Maganzini AL, Rohrer MD, Prasad HS, Kraut RA. 2009; Root and pulp response after intentional injury from miniscrew placement. Am J Orthod Dentofacial Orthop. 136:708–14. DOI: 10.1016/j.ajodo.2007.12.031. PMID: 19892289.
crossref pmid
43. Carano A, Velo S, Leone P, Siciliani G. 2005; Clinical applications of the Miniscrew Anchorage System. J Clin Orthod. 39:9–24. quiz 29–30. PMID: 29130922.
pmid
44. Suzuki EY, Buranastidporn B. 2005; An adjustable surgical guide for miniscrew placement. J Clin Orthod. 39:588–90. PMID: 16244426.
pmid
45. Poggio PM, Incorvati C, Velo S, Carano A. 2006; "Safe zones": a guide for miniscrew positioning in the maxillary and mandibular arch. Angle Orthod. 76:191–7.
pmid
46. Carano A, Velo S, Incorvati C, Poggio P. 2004; Clinical applications of the Mini-Screw-Anchorage-System (M.A.S.) in the maxillary alveolar bone. Prog Orthod. 5:212–35. PMID: 15546013.
pmid
47. Reicheneder C, Rottner K, Bokan I, Mai R, Lauer G, Richter G, et al. 2008; Mechanical loading of orthodontic miniscrews - significance and problems: an experimental study. Biomed Tech (Berl). 53:242–5. DOI: 10.1515/BMT.2008.038. PMID: 18840065.
crossref pmid
48. Kyung HM, Park HS, Bae SM, Sung JH, Kim IB. 2003; Development of orthodontic micro-implants for intraoral anchorage. J Clin Orthod. 37:321–8. quiz 314PMID: 12866214.
pmid
49. Smith A, Hosein YK, Dunning CE, Tassi A. 2015; Fracture resistance of commonly used self-drilling orthodontic mini-implants. Angle Orthod. 85:26–32. DOI: 10.2319/112213-860.1. PMID: 24869900.
crossref pmid
50. Chen Y, Kyung HM, Gao L, Yu WJ, Bae EJ, Kim SM. 2010; Mechanical properties of self-drilling orthodontic micro-implants with different diameters. Angle Orthod. 80:821–7. DOI: 10.2319/103009-607.1. PMID: 20578851.
crossref pmid
51. Lim SA, Cha JY, Hwang CJ. 2008; Insertion torque of orthodontic miniscrews according to changes in shape, diameter and length. Angle Orthod. 78:234–40. DOI: 10.2319/121206-507.1. PMID: 18251617.
crossref pmid
52. Wilmes B, Rademacher C, Olthoff G, Drescher D. 2006; Parameters affecting primary stability of orthodontic mini-implants. J Orofac Orthop. 67:162–74. DOI: 10.1007/s00056-006-0611-z. PMID: 16736117.
crossref pmid
53. Ludwig B, Glasl B, Bowman SJ, Wilmes B, Kinzinger GS, Lisson JA. 2011; Anatomical guidelines for miniscrew insertion: palatal sites. J Clin Orthod. 45:433–41. quiz 467PMID: 22094724.
pmid
54. Winsauer H, Vlachojannis C, Bumann A, Vlachojannis J, Chrubasik S. 2014; Paramedian vertical palatal bone height for mini-implant insertion: a systematic review. Eur J Orthod. 36:541–9. DOI: 10.1093/ejo/cjs068. PMID: 23221896.
crossref pmid
55. Lo Giudice A, Quinzi V, Ronsivalle V, Martina S, Bennici O, Isola G. 2020; Description of a digital work-flow for CBCT-guided construction of micro-implant supported maxillary skeletal expander. Materials (Basel). 13:1815. DOI: 10.3390/ma13081815. PMID: 32290597. PMCID: PMC7215674.
crossref
56. Yoon S, Lee DY, Jung SK. 2019; Influence of changing various parameters in miniscrew-assisted rapid palatal expansion: a three-dimensional finite element analysis. Korean J Orthod. 49:150–60. DOI: 10.4041/kjod.2019.49.3.150. PMID: 31149605. PMCID: PMC6533180.
crossref pmid pmc
57. Hourfar J, Ludwig B, Bister D, Braun A, Kanavakis G. 2015; The most distal palatal ruga for placement of orthodontic mini-implants. Eur J Orthod. 37:373–8. DOI: 10.1093/ejo/cju056. PMID: 25336563.
crossref pmid
58. Liou EJ, Chen PH, Wang YC, Lin JC. 2007; A computed tomographic image study on the thickness of the infrazygomatic crest of the maxilla and its clinical implications for miniscrew insertion. Am J Orthod Dentofacial Orthop. 131:352–6. DOI: 10.1016/j.ajodo.2005.04.044. PMID: 17346590.
crossref pmid
59. Baumgaertel S, Hans MG. 2009; Assessment of infrazygomatic bone depth for mini-screw insertion. Clin Oral Implants Res. 20:638–42. DOI: 10.1111/j.1600-0501.2008.01691.x. PMID: 19281501.
crossref pmid
60. Kravitz ND, Kusnoto B. 2007; Risks and complications of orthodontic miniscrews. Am J Orthod Dentofacial Orthop. 131(4 Suppl):S43–51. DOI: 10.1016/j.ajodo.2006.04.027. PMID: 17448385.
crossref

Figure 1
Flow chart showing the selection of studies performed according to the PRISMA guidelines.
kjod-51-3-199-f1.tif
Figure 2
Pie chart showing the proportion of the selected study designs.
kjod-51-3-199-f2.tif
Table 1
Databases screened, search strategies, and results
Database Search strategy Results
MEDLINE via PubMed searched on March 19, 2020, via www.ncbi.nlm.nih.gov/sites/entrez/ ((((orthodont*) OR (tooth movement*) OR (malocclusion*)) AND ((implant*) OR (miniscrew*) OR (mini screw*) OR (mini implant*) OR (miniscrew implant*) OR (mini screw implant*) OR (microscrew*) OR (micro screw*) OR (microimplant*) OR (micro implant*) OR (micro screw implant*) OR (osseointegrat*) OR (absolute anchorage) OR (skeletal anchorage) OR (stationary anchorage) OR (infinite anchorage) OR (temporary anchorage) OR (temporary anchorage devices) OR (TAD) OR (TADs) OR (temporary absolute anchorage) OR (temporary skeletal anchorage) OR (temporary stationary anchorage) OR (screw* AND orthodontic anchorage) OR (implant* AND orthodontic anchorage) OR (implants orthodontic anchorage) OR (screws orthodontic anchorage)))) AND (Complication* OR Side effect* OR Adverse effect* OR Negative Effect* OR Root resorption* OR Root damage* OR Root perforation* OR Tissue scarring OR Mucosal lesion* OR Gingival tissue proliferation*) 994
Cochrane Database of Systematic Reviews via The Cochrane Library searched on March 19, 2020, via www.thecochranelibrary.com ((((orthodont*) OR (tooth movement*) OR (malocclusion*)) AND ((implant*) OR (miniscrew*) OR (mini screw*) OR (mini implant*) OR (miniscrew implant*) OR (mini screw implant*) OR (microscrew*) OR (micro screw*) OR (microimplant*) OR (micro implant*) OR (micro screw implant*) OR (osseointegrat*) OR (absolute anchorage) OR (skeletal anchorage) OR (stationary anchorage) OR (infinite anchorage) OR (temporary anchorage) OR (temporary anchorage devices) OR (TAD) OR (TADs) OR (temporary absolute anchorage) OR (temporary skeletal anchorage) OR (temporary stationary anchorage) OR (screw* AND orthodontic anchorage) OR (implant* AND orthodontic anchorage) OR (implants orthodontic anchorage) OR (screws orthodontic anchorage)))) AND (Complication* OR Side effect* OR Adverse effect* OR Negative Effect* OR Root resorption* OR Root damage* OR Root perforation* OR Tissue scarring OR Mucosal lesion* OR Gingival tissue proliferation*) 44
Cochrane Central Register of Controlled Trials via The Cochrane Library searched on March 19, 2020, via www.thecochranelibrary.com ((((orthodont*) OR (tooth movement*) OR (malocclusion*)) AND ((implant*) OR (miniscrew*) OR (mini screw*) OR (mini implant*) OR (miniscrew implant*) OR (mini screw implant*) OR (microscrew*) OR (micro screw*) OR (microimplant*) OR (micro implant*) OR (micro screw implant*) OR (osseointegrat*) OR (absolute anchorage) OR (skeletal anchorage) OR (stationary anchorage) OR (infinite anchorage) OR (temporary anchorage) OR (temporary anchorage devices) OR (TAD) OR (TADs) OR (temporary absolute anchorage) OR (temporary skeletal anchorage) OR (temporary stationary anchorage) OR (screw* AND orthodontic anchorage) OR (implant* AND orthodontic anchorage) OR (implants orthodontic anchorage) OR (screws orthodontic anchorage)))) AND (Complication* OR Side effect* OR Adverse effect* OR Negative Effect* OR Root resorption* OR Root damage* OR Root perforation* OR Tissue scarring OR Mucosal lesion* OR Gingival tissue proliferation*) 96
Web of Science searched on March 19, 2020, viawww.webofknowledge.com ((((orthodont*) OR (tooth movement*) OR (malocclusion*)) AND ((implant*) OR (miniscrew*) OR (mini screw*) OR (mini implant*) OR (miniscrew implant*) OR (mini screw implant*) OR (microscrew*) OR (micro screw*) OR (microimplant*) OR (micro implant*) OR (micro screw implant*) OR (osseointegrat*) OR (absolute anchorage) OR (skeletal anchorage) OR (stationary anchorage) OR (infinite anchorage) OR (temporary anchorage) OR (temporary anchorage devices) OR (TAD) OR (TADs) OR (temporary absolute anchorage) OR (temporary skeletal anchorage) OR (temporary stationary anchorage) OR (screw* AND orthodontic anchorage) OR (implant* AND orthodontic anchorage) OR (implants orthodontic anchorage) OR (screws orthodontic anchorage)))) AND (Complication* OR Side effect* OR Adverse effect* OR Negative Effect* OR Root resorption* OR Root damage* OR Root perforation* OR Tissue scarring OR Mucosal lesion* OR Gingival tissue proliferation*) 654
LILACS searched on March 19, 2020, via http://bvsalud.org/en/ (tw:(miniscrews)) OR (tw:(mini implants)) OR (tw:(miniscrew implants)) OR (tw:(TADs)) OR (tw:(temporary anchorage)) OR (tw:(skeletal anchorage)) AND (tw:(complications)) OR (tw:(side effects)) OR (tw:(negative effects)) OR (tw:(adverse effects)) 115
BBO searched on March 19, 2020, via http://pesquisa.bvsalud.org/portal/advanced/?lang=en. (tw:(miniscrews)) OR (tw:(mini implants)) OR (tw:(miniscrew implants)) OR (tw:(TADs)) OR (tw:(temporary anchorage)) OR (tw:(skeletal anchorage)) AND (tw:(complications)) OR (tw:(side effects)) OR (tw:(negative effects)) OR (tw:(adverse effects)) 73
Clinical Trials. searched on March 19, 2020,via http://clinicaltrials.gov/ct2/home 4
Table 2
Eligibility criteria according to the PICO format
Field Inclusion criteria Exclusion criteria
Patient Healthy human subjects treated with orthodontic miniscrews Syndromic patients, orthognathic surgery
Intervention Miniscrews inserted for orthodontics purpose First generation miniscrews, miniplates
Comparison Not applicable Not applicable
Outcome Soft and hard-tissue complication related to the use of orthodontic miniscrews Complication related to the orthodontic treatment
Study design Case reports, RCTs, PCTs, retrospective longitudinal studies, case series Abstract, in-vitro studies, descriptive studies, review, and meta-analysis

RCTs, randomized controlled trials; PCTs, prospective clinical trials.

Table 3
Number of excluded studies and the reasons for exclusion
Exlcusion reason Articles excluded on the basis of title and abstract Articles excluded after full-text evaluation
Not compatible methodology 81 4
Expert opinions 11 3
Abstract 60
Review and meta-analysis 93 4
Descriptive studies 64 6
Different topic 688 5
Different evaluated outcome 305 15
Animal studies 67
In-vitro studies 54 2
Trial in progress 1
Total 1,424 39
Table 4
Characteristics of the selected studies
Study Study
design
Sample
size
Mean
age
Sex Insertion
site
Complication
type
Observation
period
Type of
implant
Surgical insertion procedure
Agrawal
et al.13
(2013)
Case report 1 16 F Buccal alveolar bone between roots of maxillary central and lateral incisors on both sides Alveolar bone exostoses 2 months 1.2 mm diameter and 8 mm length -
Al-Kharsa
and
Masoud14
(2017)
Case report 1 - - Lingual alveolar bone between the roots of 46–47 -
Chen
et al.24
(2011)
Retrospsective
study
20 24.3 15 F/5 M Interradicular bone between the bilateral maxillary second premolar and first molar Pain following microimplant treatment 3 months 1.2 diameter and 8 length. Non self-drilling. Absoanchor; Dentos, Daegu, Korea Low-speed (400–500 rpm) pilot drill handpiece (diameter, 1 mm) used to penetrate the cortical level of bone only
Choi
et al.15
(2015)
Case report 1 20 F Interdental alveolar bone, distal to the maxillary canines at the mucogingival junction Scar lesion at the miniscrew removal site 3 months Two self-drilling orthodontic miniscrews (1016107; Ortholution, Seoul, Korea) -
Er et al.16
(2011)
Case report 1 22 F Bilaterally behind the incisive canal in the palatal interradicular spaces between the lateral incisor and canine Periradicular lesion caused by unintentional root damage 10 months Aarthus Anchorage System; MediconeG, Tuttlingen, Germany. 1.5 mm in diameter and 10 mm in length -
Fabbroni
et al.34
(2004)
Prospective study 55 16–52 54 M/1 F Interradicular space in mandible and maxilla Minor and major contact of adjacent teeth; loss of vitality, granulation tissue 7 months Transalveolar screws: 2.0 mm titanium capstan headed screws -
Fäh and
Schätzle25
(2014)
Retrospective study 146 19.5 years (implantations); 22.8 years (explantations) 104 implantations (33 M/71 F); 44 explantations (9 M/35 F) Median and paramedian Complication associated with the implantation: no primary stability, prolonged pain, secondary bleeding, perforation of nasal floor, necrotic mucosa, sensory impairment - Palatal implant (Orthosystem; Institut Straumann AG, Basel, Switzerland). Self-tapping Placed according to the Straumann guidelines for respective palatal implants. After local anesthesia, the palatal mucosa was either removed with a punch and an elevator or by open flap technique. After marking the center of the site with round drill, the hole was drilled by spiral drills. The self-tapping implant was inserted by hand with a ratchet. After the orthodontic treatment the palatal implant was removed using trephin
Complication associated with the explantation: disturbed wound healing, perforation of nasal floor, secondary bleeding, fracture of the implant
Ghislanzoni
et al.17
(2016)
Case report 1 11 M Insertion of palatal miniscrew at the height of the second palatal rugae Anchorage and bone loss around insertion site 14 months 6 mm miniscrew (3M Unitek, Monrovia, CA, USA) -
Gracco
et al.36
(2010)
Case series 4 24.3 3 F/1 M Buccal insertion either between the second premolar and the first molar or between the first and second molars, at a 45° angle to the occlusal plane Protrusion of the screw into sinus - Orthodontic miniscrews (Vector TAS; Ormco, Brea, CA, USA) of different lengths and diameters -
Gurdan and
Szalma26
(2018)
Retrospective study 47 - F Palate, buccal fold, ascending ramus Peri-implant inflammation in bone and in soft tissue, screw fracture 2 years One or more self-drilling mini-screws (Jeil Dual Top Anchor System; Jeil Medical Corp., Seoul, Korea) with a dimension of 1.6 mm × 8 mm Every screw was placed hand driven with the screwdriver tool of the mini-implant system
Hourfar
et al.27
(2017)
Retrospective study 284 14.4 years
(± 8.8)
182 F/102 M Paramedian insertion in the anterior palate: at second rugae (76); between second and third rugae (24); at third rugae (468) Loss to pulp sensibility testing (PST) of maxillary front teeth - OrthoEasy®, Forestadent, Pforzheim, Germany (1.7 mm diameter, length 8 mm); anodized surface and features a self-tapping and cutting design (Ti-6Al-4 V) OMIs inserted without soft tissue incision or pre-drilling, perpendicularto the bone surface, using a motorised dentalhandpiece at an insertion speed of 60 RPM. Torque limitationwas 30 Ncm
Hwang and
Hwang18
(2011)
Case report 1 46 M Interradicular area between the central and lateral incisors Root perforation of mandibular lateral incisor 1 year
Jia et al.28
(2018)
Retrospective study 32 28 ± 6 years 10 M/22 F Infrazygomatic crest Penetration of infrazygomatic crest miniimplants into the sinus 13 months Self-drilling mini-implants (A1, Penghua, Taiwan; stainless steel, 2 mm in diameter, 12–17 mm in length according to the individual anatomic variation). The mean length of the mini-implant was 14 mm, and the mean embedded angulation was 29.6° Incision in the buccal keratinized gingiva near the mucogingival junction of the maxillary first molar, limited to less than 2 mm. A hand screwdriver used for mini-implant insertion
Jung et al.29
(2015)
Study cohort 66 F: 28.5 ± 10.02 years;
M: 28.9 ± 8.87 years
52 F/14 M Buccolingual insertion sites: maxillary buccal and mandibular buccal (within the attached gingiva, at the mucogingival junction, or within the alveolar mucosa), palatal slope, and midpalatal regions Soft tissue scarring 6–58
months
Two types of selfdrilling Miniscrew: cylindrical type (1.5 mm indiameter, 7 mm in length; ACR OAS-T1507, BiomaterialsKorea, Seoul, Korea) or combined cylindricaland tapered type (1.8 mm in diameter, 7 mm in length;Orlus Classic 1O18107, Ortholution, Seoul, Korea) Hand driver used to insert and remove miniscrew
Lee et al.19
(2016)
Case report 1 21 F Interradicular area, mesial and apical to the left maxillary second premolars Root perforation 3 years 1.5 × 8.0 mm, Biomaterials Korea, Seoul, Korea. Miniscrew’s sharp drilling tip -
Lim et al.23
(2013)
Case report 1 44 M Buccal and palatal interradicular attached gingiva between the left maxillary first and second molars Root damage 3 years 1.8 mm in diameter and 7-mm long (Orlus 1O18107; Orlus Korea, Seoul, Korea) Miniscrews inserted using the self-drilled manual method
Marquezan
et al.20
(2012)
Case report 1 - - Interradicular between the maxillarycentral incisors Traumatic lesion in the frenulum - - -
McCabe
and
Kavanagh21
(2012)
Case report 1 25 F Interradicular area between the maxillary second premolar and first molar tooth Root perforation, miniscrew’s tip fractured 5 years Two self-screwing 8-mm long 1.3–1.2 mm tapered miniscrews Round bur used to mark the attached buccal mucosa and cortical bone
Motoyoshi
et al.32
(2015)
Prospective study 45 23.3 ± 8.9 years 28 F/17 M Maxillary alveolar bone between second premolar and first molar Maxillary sinus perforation - Self-drill miniscrews (ISA orthodontic anchor screw; diameter, 1.6 mm; length, 8 mm; Biodent, Tokyo, Japan) A hand screwdriver used to place the miniscrew without a pilot hole so that it was inclined at 40° to 60° from vertical to the adjacent tooth axis
Qin et al.22
(2016)
Case report 1 23 F Between the root apices of the maxillary central incisors Pink discoloration of the tooth and no response to EPT suggesting pulp necrosis 15 months One 6-mm-long, 1.6-mm-diameter ‘Tomas’ miniscrew implant -
Shinohara
et al.33
(2013)
Prospective study 50 21.8 ± 5.7 35 F/15 M Buccal alveolar bone between roots of maxillary central and lateral incisors on both sides Root contact by mini implants - Commercial mini-implants (diameter, 1.6 mm; length, 8 mm; ISA orthodontic mini-implants; Biodent, Tokyo, Japan) A pilot hole drilled in the buccal alveolar bone between the second premolar and the first molar of the maxilla or the mandible without creation of a flap. The pilot hole inclined 45° to 60° vertically to the adjacent tooth axis
Takaki
et al.30
(2010)
Retrospective study 455 M: 23.8 ± 9.2 years; F: 26.2 ± 9.9 years 97 M/358 F Mini andmicroscrew: mandible (anterior alveolar region, posterior alveolar region, external oblique ridge, retro-molar region), maxilla (anterior alveolar region, posterior alveolar region, posterior alveolar palate region, median suture, paramedian suture, maxillary zygomatic butress); PIAS: mandible (posterior alveolar region, retro-molar region), maxilla (anterior alveolar region, median suture, paramedian suture) Acute and chronic inflammation (granulation tissue) of the soft tissue surrounding implant - Two different self-drilling titanium miniscrew implant systems (Dualtop autoscrew; Jeil Medical Corp., Seoul, Korea; OSAS; DEWIMED Co. Ltd., Tuttlingen, Germany), one pre-drilling microimplant system (K1 system; Dentsply-Sankin, Tokyo, Japan) and a palatal implant anchorage system (PIAS, Tokyo Dental College, Tokyo, Japan) Micro- and mini-implants inserted into the gingival or palate and placed according to their manifacturers’ protocols
Wang
et al.35
(2010)
Preliminary report 54 21.8 years 34 F/20 M Buccal alveolar bone between the second premolar and first molar, between the first and second molars, between the second and third molars. Three angulations: 10–30°, 30–60°, 60–80°. Two different occlusogingival position: less than 3 mm from the mucogingival line, more than 3 mm from the mucoginigval line Buccal mucosal lesion and trauma associated to miniscrew 5 years Aarthus miniscrews (prism shaped head, 3 mm in diameter and 2.3 mm long) -
Ziebura
et al.31
(2012)
Retrospective study 41 15.1 years 19 M/22 F Recommended location and slight deviation: half of the distance of the perpendicular line segment from raphe to the palatal cusp tip of the first bicuspid Overgrowth, defined as the partial or complete covering of the implant head by soft tissue, palatal mucosa 6 months Screws with necks of 3 or 5 mm; thread 8 mm long and 2 mm in diameter Insertion using a surgical handpiece

F, female; M, male; OMI, orthodontic miniscrew implant; EPT, electric pulp testing.

Table 5
Complications – Part I (interradicular insertion sites)
Jaw Anterior region Lateral region Posterior region



Maxilla Maxilla Mandible Maxilla Maxilla Maxilla Maxilla Maxilla Maxilla Maxilla Maxilla Maxilla Maxilla Mandible Mandible
Sample 1 F 1 F 2 M 1 F 1 F 15 F 5 M 1 F 1 F 28 F 17 M 35 F 15 M 1 M 52 F14 M 1 M 52 F14 M 35 F 15 M
Miniscrew 1 2/2 1/2 2/2 1/2 NA 1/2 1 8/82 68 2/2 68/122 1/2 17/62 79
Complication Crown pink discoloration, no response to EPT22 Exostoses13 Root perforation18 Scar lesion15 Root perforation19 Pain24 Protrusion into the sinus36 Root perforation & miniscrew fracture21 Maxillary sinus perforation32 Root contact33 Protrusion into the sinus36 Scar lesion29 Root damage23 Scar lesion29 Root contact33

F, female; M, male; NA, not applicable; EPT, electric pulp testing.

Table 6
Complications – Part II (extraalveolar insertion sites)
Infrazygomatic crest Palate Ascending ramus Buccal shelf
Sample 2 F 22 F 10 M 47 52 F14 M 22 F19 M 1 F 1 M 182 F102 M 106 F42 M 47 47 1
Miniscrew 2/2 47/60 2/32 4/17 8/66 1/2 1 NA 31/148 2/3 3/24 1
Complication Protrusion of the screw into the sinus36 Penetration into the sinus28 Inflammation26 Scars29 Overgrowth31 Periradicular lesion16 Bone loss around the inserion site17 Loss of response to PST27 Pain, bleeding, nasal floor perforation, necrotic mucosa, sensory impairment, disturbed wound healing, miniscrew fracture25 Miniscrew facture, inflametion26 Inflammation26 Traumatic lesion20

F, female; M, male; NA, not applicable; PST, pulp sensibility test.

Table 7
Risk-of-bias assessment
Studies Selection Comparability Outcome



Representativeness of the exposed cohort Selection of
the non
exposed
cohort
Ascertainment
of exposure
Demonstration that outcome of interest was not present at start of study Comparability of cohorts on the basis of the design or analysis Assessment of outcome Was follow-up long enough for outcomes to
occur
Adequacy of
follow up of cohorts
Chen et al.24 - - - - -
Fäh and Schätzle25 - - - -
Gurdan and Szalma26 - - -
Hourfar et al.27 - - - -
Jia et al.28 - - - -
Jung et al.29 - - -
Takaki et al.30 - - - -
Ziebura et al.31 - - -

The Newcastle-Ottawa Scale consists of 8 multiple-choice questions that address subject selection (4 questions), comparability (1 question), and outcome assessment (3 questions). High-quality responses would be awarded up to 9 points (the comparability question earns up to 2 points).

TOOLS
Similar articles