Abstract

Implant-Assisted Removable Partial Dentures (IARPDs) treatment is being performed in a fully edentulous patient using implant surveyed prosthesis as an abutment. Implant-supported prosthesis as an abutment of IARPDs is classified into screw-retained and cement-retained type according to the retention type, and each has advantages and disadvantages. The EZ crown system (Samwon DMP, Yangsan, Korea) has a cylinder combined with abutment, and the nickel-titanium spring in this cylinder provides a constant force on the zirconia ball to obtain retention in EZ crown system. In this patient, the natural abutment teeth of the mandibular overdenture was hopeless. We planned implant assisted removable partial denture using anterior implant surveyed prosthesis considering functional and esthetical rehabilitation, cost and patient's needs. When fabricating IARPDs using implant as abutment, we could compensate for the shortcomings of existing implant-supported prosthesis retention type and made the design of removable partial denture easy due to using EZ crown system.

Figures and Tables

Fig. 1

Schematic Design of EZ crown system (Samwon DMP, Yangsan, Korea). (A) Abutment connected to implant fixture, (B) Cylinder connected to abutment, (C) Cylinder inner structure, (D) All components of EZ crown system connected.

jkap-58-58-g001
Fig. 2

Panoramic radiograph before treatment.

jkap-58-58-g002
Fig. 3

Panoramic radiograph after implantation.

jkap-58-58-g003
Fig. 4

Intraoral photographs after implantation. (A) Right view, (B) Frontal view, (C) Left view, (D) Occlusal view (Maxilla), (E) Occlusal view (Mandible).

jkap-58-58-g004
Fig. 5

Fabrication of provisional restoration. (A) Intraoral photographs after cap delivered (Occlusal view, Mandible), (B) Impression taking of mandible, (C) Registration of inter-occlusal relationship with leaf gauge, (D) Occlusal view of provisional restoration, (E) Frontal view of provisional restoration.

jkap-58-58-g005
Fig. 6

Fabrication of implant surveyed prosthesis. (A) Occlusal view of abutment before gingivectomy, (B) Occlusal view of abutment after gingivectomy, (C) Occlusal view of cap delivered, (D) Final impression taking for implant surveyed prosthesis.

jkap-58-58-g006
Fig. 7

Fabrication of implant surveyed prosthesis. (A) Facebow transfer, (B) Registration for inter-occlusal relationship with resin base and wax rim, (C) Shade taking.

jkap-58-58-g007
Fig. 8

Computer-aided design for zirconia implant surveyed prosthesis. (A) Frontal view, (B) Frontal view of implant surveyed prosthesis design, (C) Occlusal view of implant surveyed prosthesis design, (D) Occlusal view of implant surveyed prosthesis on working model.

jkap-58-58-g008
Fig. 9

Cementation process of implant surveyed prosthesis. (A) Occlusal view of cap attached, (B) Cementation (G-cem linkace), (C) Excess cement around cap, (D) Bottom surface of implant surveyed prosthesis after removing excess cement.

jkap-58-58-g009
Fig. 10

Intraoral photographs after implant surveyed prosthesis placement. (A) Right view, (B) Frontal view, (C) Left view, (D) Occlusal view (Maxilla), (E) Occlusal view (Mandible).

jkap-58-58-g010
Fig. 11

Fabrication of metal framework. (A) Final impression for removable partial denture, (B) Metal framework on working model, (C) Intraoral try-in of metal framework.

jkap-58-58-g011
Fig. 12

(A) Functional impression for removable partial denture, (B) Altered cast fabrication, (C) Metal framework and occlusal rim, (D) Bite registration.

jkap-58-58-g012
Fig. 13

Definitive prosthesis.

jkap-58-58-g013
Fig. 14

Intraoral photographs after definitive prosthesis delivery. (A) Right view, (B) Frontal view, (C) Left view, (D) Occlusal view (Maxilla), (E) Occlusal view (Mandible).

jkap-58-58-g014

Notes

This paper was supported by the grant of clinical research funding of the Dental Hospital of Pusan National University in 2018.

References

1. Jorge JH, Quishida CC, Vergani CE, Machado AL, Pavarina AC, Giampaolo ET. Clinical evaluation of failures in removable partial dentures. J Oral Sci. 2012; 54:337–342.
crossref pmid
2. Cho YJ, Suh BH. The use of an implant-supported fixed partial denture as abutment teeth for removable partial denture in edentulous patient: A cases report. Korean Acad Oral Maxillofac Implantol. 2017; 21:96–108.
crossref
3. Lee YJ, Bae EB, Jeong CM, Lee JJ, Jim JY, Huh JB. Removable partial denture using anterior implant-supported fixed prostheses for edentulous patients: A case report. J Korean Dent Sci. 2017; 10:87–95.
4. Na HJ, Kang DW, Son MK. Distal-extension removable partial denture with anterior implant prostheses: Case report. J Dent Rehabil Appl Sci. 2011; 27:437–447.
5. Pellecchia M, Pellecchia R, Emtiaz S. Distal extension mandibular removable partial denture connected to an anterior fixed implant-supported prosthesis: A clinical report. J Prosthet Dent. 2000; 83:607–612.
crossref pmid
6. Kourtis SG, Sotiriadou S, Voliotis S, Challas A. Private practice results of dental implants. Part I: survival and evaluation of risk factors-Part II: surgical and prosthetic complications. Implant Dent. 2004; 13:373–385.
crossref pmid
7. Phillips K, Wong KM. Space requirements for implant-retained bar-and-clip overdentures. Compend Contin Educ Dent. 2001; 22:516–518. 520522
pmid
8. Wittneben JG, Joda T, Weber HP, Brägger U. Screw retained vs. cement retained implant-supported fixed dental prosthesis. Periodontol 2000. 2017; 73:141–151.
crossref pmid
9. Kang SH, Kim SK, Heo SJ, Koak JY, Lee JH, Park JM. Clinical evaluation of the removable partial dentures with implant fixed prostheses. J Korean Acad Prosthodont. 2016; 54:239–245.
crossref
10. Choi JW, Choi KH, Chae HJ, Chae SK, Bae EB, Lee JJ, Lee SH, Jeong CM, Huh JB. Load-bearing capacity and retention of newly developed micro-locking implant prosthetic system: An in vitro pilot study. Materials (Basel). 2018; 11:564.
crossref
11. Choi JW, Lee JJ, Bae EB, Huh JB. Implant-supported fixed dental prosthesis with a microlocking implant prosthetic system: A clinical report. J Prosthet Dent. 2019; 05. S0022-3913(19)30014-9.
crossref
12. Choi JW, Song CH, Huh JB. Implant-supported fixed dental prostheses with new retention type using zirconia ball and nickel-titanium spring. Implantology. 2019; 23:16–24.
crossref
13. Wang TM, Leu LJ, Wang J, Lin LD. Effects of prosthesis materials and prosthesis splinting on peri-implant bone stress around implants in poor-quality bone: a numeric analysis. Int J Oral Maxillofac Implants. 2002; 17:231–237.
pmid
14. Park JM, Koak JY, Kim SK, Alexander J, Heon SJ. Consideration for the combination treatment of removable partial denture and implant. Implantology. 2015; 19:104–111.
15. Shahmiri R, Das R, Aarts JM, Bennani V. Finite element analysis of an implant-assisted removable partial denture during bilateral loading: occlusal rests position. J Prosthet Dent. 2014; 112:1126–1133.
crossref pmid
16. Shahmiri R, Das R. Finite element analysis of implant-assisted removable partial dentures: Framework design considerations. J Prosthet Dent. 2017; 118:177–186.
crossref pmid
17. Ryu BG, Choi WS, Cho HJ, Kim KK. The use of an implant fixed partial denture as abutment teeth for removable partial denture in unilateral edentulous patient: A cases report. Implantology. 2016; 20:24–34.
18. Cochran DL. The evidence for immediate loading of implants. J Evid Based Dent Pract. 2006; 6:155–163.
crossref pmid
19. Gallucci GO, Benic GI, Eckert SE, Papaspyridakos P, Schimmel M, Schrott A, Weber HP. Consensus statements and clinical recommendations for implant loading protocols. Int J Oral Maxillofac Implants. 2013; 08. 15.
crossref
TOOLS
ORCID iDs

You-Kyoung Oh
https://orcid.org/0000-0002-6399-057X

Chang-Mo Jeong
https://orcid.org/0000-0001-5009-9799

Mi-Jung Yun
https://orcid.org/0000-0003-3093-8406

So-Hyoun Lee
https://orcid.org/0000-0003-3094-6086

Hyeon-Jong Lee
https://orcid.org/0000-0002-1669-2975

Jung-Bo Huh
https://orcid.org/0000-0001-7578-1989

Similar articles