Journal List > J Korean Fract Soc > v.33(1) > 1142117

Jeon, Oh, Cho, and Kim: Tension Band Wiring Technique for Distal Radius Fracture with a Volar Articular Marginal Fragment: Technical Note

Abstract

Most distal radius fractures are currently being treated with anterior plating using anatomical precontoured locking compression plates via the anterior approach. However, it is difficult to fix the volar articular marginal fragment because these anatomical plates should be placed proximally to the watershed line. There were just a few methods of fixation for this fragment on medical literature. Herein, we introduced a tension band wiring technique for fixation of a volar articular marginal fragment in the distal radius.

Figures and Tables

Fig. 1

(A) Volar articular marginal fragment (circles with the dotted line) with a comminuted metaphyseal fracture of the distal radius on plain radiography. (B) Three-dimensional computed tomography scan also shows the volar articular marginal fragment.

jkfs-33-38-g001
Fig. 2

(A) Two K-wires were inserted from the distal edge of the volar articular marginal fragment to the posterior cortex proximally and posteriorly after reduction with pointed forceps through the modified Henry approach. (B) The position of two K-wires was checked on the anteroposterior and lateral view of the C-arm image.

jkfs-33-38-g002
Fig. 3

Tension band wiring for the volar articular marginal fragment after plating.

jkfs-33-38-g003
Fig. 4

Radiologic union (A) and near full fuctional recovery (B) were achieved at postoperative 6 weeks.

jkfs-33-38-g004
Fig. 5

(A) The simple volar articular marginal fragment of the distal radius on plain radiography. (B) Three-dimensional computed tomography scan also shows more clearly the volar articular marginal fragment.

jkfs-33-38-g005
Fig. 6

(A) Immediate postoperative radiograph. Protrusion of the K-wire was seen on the oblique view (circle with the dotted line). (B) Complete union was seen on the postoperative 1-year X-ray. (C) Deficit of wrist flexion still remained due to protrusion of the K-wire at postoperative 1-year follow up. (D) Postoperative X-ray after implant removal. (E) The deficit of wrist flexion was full recovered after removal of the implant.

jkfs-33-38-g006

Notes

Financial support None.

Conflict of interests None.

References

1. Conti Mica MA, Bindra R, Moran SL. Anatomic considerations when performing the modified Henry approach for exposure of distal radius fractures. J Orthop. 2017; 14:104–107.
crossref pmid
2. Orbay J. Volar plate fixation of distal radius fractures. Hand Clin. 2005; 21:347–354.
crossref pmid
3. Chin KR, Jupiter JB. Wire-loop fixation of volar displaced osteochondral fractures of the distal radius. J Hand Surg Am. 1999; 24:525–533.
crossref pmid
4. Schumer ED, Leslie BM. Fragment-specific fixation of distal radius fractures using the Trimed device. Tech Hand Up Extrem Surg. 2005; 9:74–83.
crossref pmid
5. Katznelson A, Volpin G, Lin E. Tension band wiring for fixation of comminuted fractures of the distal radius. Injury. 1980; 12:239–242.
crossref pmid
6. van Aaken J, Beaulieu JY, Della Santa D, Kibbel O, Fusetti C. High rate of complications associated with extrafocal kirschner wire pinning for distal radius fractures. Chir Main. 2008; 27:160–166.
crossref pmid
TOOLS
ORCID iDs

Neunghan Jeon
https://orcid.org/0000-0002-5509-8346

Jong-Keon Oh
https://orcid.org/0000-0002-5184-6036

Jae-Woo Cho
https://orcid.org/0000-0003-4962-3535

Youngwoo Kim
https://orcid.org/0000-0003-1851-7334

Similar articles