Journal List > Ann Occup Environ Med > v.31(1) > 1127199

Park and Kim: A case of extensor pollicis longus (EPL) tendon rupture in an automotive assembly line worker: an ergonomic evaluation through job strain index (JSI) and musculoskeletal risk factor survey

Abstract

Background

We report a case of extensor pollicis longus (EPL) tendon rupture caused by repetitive motions and awkward posture on hand and wrist joints.

Case presentation

A 47-year-old right-handed man who worked for 15 years in an assembly line at an automotive manufacturing company has been diagnosed with a complete tear of right EPL tendon. We investigated the patient's occupational history in detail and evaluated the tasks ergonomically through musculoskeletal risk factors survey and job strain index (JSI) using the 22 task-related videos recorded by the patient. Three out of the 12 tasks (25%) were identified as high-risk work on the hand and wrist in the musculoskeletal risk factors survey in 2016. Among the 22 tasks analyzed by JSI, 11 tasks (50%) were evaluated as probably hazardous. In addition, he used localized vibration tools in 19 (86.4%) out of 22 tasks.

Conclusion

We concluded the patient's disease was probably caused by repetitive motion and improper posture of the hand and wrist, and the hand-arm vibration is a possible cause as well.

Abbreviations

EPL

extensor pollicis longus

JSI

job strain index

MRI

magnetic resonance imaging

WMSD

work-related musculoskeletal disorder

BACKGROUND

The extensor pollicis longus (EPL) originates from the posterior surface of ulna and interosseous membrane, and inserts to the base of distal phalanx of thumb [1]. EPL extends the distal phalanx of thumbs [2]. The rupture of EPL tendon can be caused by distal fracture of radius, distal incomplete dislocation of ulna, complication of steroids treatment and chronic inflammatory conditions such as tendon synovitis, rheumatoid arthritis of hand and wrist joints [345678].
There have been several case reports of EPL tendon rupture in chefs and tailors who repeatedly use their hands and wrists, and in athletes such as skiers, goalkeepers, kick boxers, and break dancers [910111213]. There were also case reports of a 30-year-old man who had played video games 8–10 hours per week for over 20 years, and a 29-year-old man who played a smartphone game all day long for 8 weeks [1415]. These previous cases only briefly reported patients' occupational and social history. The purpose of this study is to report a case of EPL tendon rupture in an automotive assembly line worker through detailed job analysis and ergonomic evaluation.

CASE PRESENTATION

Patient information

Forty-eight-year-old man.
Right handed.

Chief complaints

Pain and limited range of motion, thumb, right.

Present illness

On November 6, 2014, while he was lifting a 3.1 kg antifreeze injection gun at the workplace, there was a crack sound and pain in the right wrist, and he could not move his right thumb. Before the onset of symptoms, there was no specific trauma or any other symptoms at the site. The ultrasonographic image taken on the day of the accident showed a complete EPL tendon rupture with a 4.31 cm gap in the right wrist (Fig. 1), and the magnetic resonance imaging (MRI) images taken 4 days after the accident also showed a complete tear of EPL tendon with a 5.6 cm gap in the right wrist (Fig. 2). The patient underwent immunohistochemistry including general blood tests to confirm the possibility of rupture by rheumatism. The C-reactive protein level was 0.16 mg/dL (normal range is less than 0.49 mg/dL), the rheumatoid factor level was 5.0 mg/dL (normal range is less than 20.0 mg/dL), the anti-cyclic citrullinated peptide antibody level was 7.0 U/mL (normal range is less than 17.0 U/mL) and the uric acid level was 8.4 mg/dL (normal range is from 3.5 to 7.0 mg/mL). He underwent a repair operation 4 days after the accident and he has recovered from the illness.
Fig. 1

Ultrasonographic finding of the patient's right wrist. Extensor pollicis longus tendon rupture, wrist level, 4.31 cm gap. Hypoechoic fluid in the expected location of the tendon (arrow).

aoem-31-e2-g001
Fig. 2

T2-weighted magnetic resonance imaging of the right hand. Complete tear of extensor pollicis longus tendon (A) Coronal view: no tendon in the gap (between 2 arrows) (B) Transverse view: no tendon in the expected course (arrow).

aoem-31-e2-g002

Past medical

He received medical treatment for lumbar disc herniation from 7th July 2001 to 26th February 2006 and he was allowed to claim worker's compensation insurance. He was treated conservatively for the right third trigger finger that occurred on March 27, 2008.

Social history & family history

He played badminton for about 15 minutes a day during lunch break in 2007, and he quit after the conservative treatment for his right third trigger finger. He was an ex-smoker (1.5 pack-years) and social drinker. There was no special family history.

Occupational history

He joined an automotive manufacturing company on February 13, 1995. He had engaged in assembly line work, shifting day and night for 10 hours a day, until February 2013, and he performed day shifting work for 8 hours a day from February 2013 to the present. After joining the company, he has worked for about 15 years in the same assembly line except for the period of medical care for his lumbar disc herniation. His job is the line work to assemble 36 cars per hour, he is not able to self-control the speed. His work groups consist of a total of four, with 1 group consisting of 12 people, and each group shifts monthly. According to the patient's statement, the labor intensity in the past was higher than that of the current work, and the difference in labor intensity from the different vehicle models was not significant. He did not wear any protective gear such as anti-vibration gloves during work.

Work-relevance evaluation

On January 16, 2017, he visited the occupational and environmental medicine outpatient clinic at a University Hospital in Busan, Korea for the work-relevance evaluation. First, the authors investigated the detailed job history by interviewing him. We performed a simple job simulation and confirmed that his tasks have repetitive motion and inadequate postures of the thumb and wrist. Especially applying pressure with extended thumb and hammering with extended wrist to deliver a strong and rapid impact seemed to be harmful. Fig. 3 shows his tasks considered burdensome. He complained that assembling door scarf, installing tailgate trim panel, and adjusting windshield glasses are particularly burdensome on his thumb and wrist.
Fig. 3

Thumb and wrist joints burden of the patient's tasks. Extension of the thumb and ulnar deviation of the wrist are thought to be burden on the extensor pollicis longus tendon. (A, B) Extension of the thumb: applying pressure while installing door trim and trunk garnish (C) Ulnar deviation of the wrist: holding the hand-arm vibration tool while injecting antifreeze liquid (D) Repetitive motion of the wrist: tightening a screw with the wrench while installing air cleaner, battery cable, and duct.

aoem-31-e2-g003
We requested the results of musculoskeletal risk factors survey for the patient's workplace. In accordance with the Rule 657 of Korean Occupational Safety and Health Act, employers shall investigate the risk factors of the following items every 3 years when workers are carrying out musculoskeletal burden work [16].
  • A. Workplace situation: facilities, work process, work volume, work speed, etc.

  • B. Working conditions: working time, working posture, and working method.

  • C. Work-related musculoskeletal signs and symptoms.

In the 2016 investigation, his work was divided into 12 tasks by the rule, and each task was divided into 6 burdened body parts (fingers/hands/wrists, arms/elbows, shoulders, neck, waist, and knees/legs). They were scored in terms of work posture, repeatability/static posture, strength and other burden work (hammering with hand or using vibration tools). Table 1 shows the results of 2016 musculoskeletal risk factors survey on fingers/hands/wrists. Adjusting position after mounting windshield glasses, tailgate weather strip fit, and installing tailgate trim panel were high scored tasks, and they have the similar tendency to the patient's subjective assessment of thumb and wrist burdens.
Table 1

Results of 2016 musculoskeletal risk factors survey on fingers, hands, and wrists for the patient's work

aoem-31-e2-i001
Task Working posture* Repetitive motion and static posture Force Other burdens§ Score
Assembling front door scarf 1 2 2 1 (B) 6
Installing knee air bag 1 2 3
Loading rear seatback 1 5 6
Assembling rear seat back 1 1 (A) 2
Loading windshield glasses (using a lifting machine) 1 2 3
Adjusting position after mounting windshield glasses 2 2 2 1 (B) 7
Assembling left-hand front sea 1 1 (A) 2
Installing steering wheel 1 2 3
Installing cowl top cover 1 1
Installing tailgate trim panel 1 2 2 1 (B) 7
Mounting wiper arm and blade 2 2 4
Tailgate weather strip fit 1 2 2 1 (B) 7
Score: 1–2, normal; 3–5, points cautious work; 5–6, points risk work; 7, points high-risk work.
Score criteria are shown as follows. *1: Wrist flexion/extension 20–45°, twist less than 30°, finger gripping; 2: Wrist flexion/extension more than 45°, twist more than 30°. 2: More than 10 times per minute or static posture for more than 10 seconds; 3: More than 20 times per minute or static posture for more than 30 seconds. 2: When using parts or tools requiring significant force on fingers and wrists; 5: Hard work that requires a lot of force. §1: Hammering with a hand more than 10 times per hour (A); 1: Using vibration tool more than 2 hours (B).
In order to evaluate the burden more quantitatively, we divided his work by 22 tasks focusing on the right thumb and wrist (job sampling) and requested him to record videos of the 22 tasks. We discussed the videos with him and retook several times, and finally obtained the total 22 task-related videos. We evaluated his work through job strain index (JSI) using these 22 task-related videos in order to analyze more objectively. JSI is an ergonomic evaluation method that mainly evaluates the upper extremities to quantitatively assess the ergonomic risk level of hand and wrist joints [1718]. Under the guidance of an ergonomic expert, authors analyzed the total 22 task-related videos focusing on his right thumb and wrist. The results of JSI analysis were tabulated in Table 2. Among the 22 tasks analyzed by JSI, 11 tasks (50%) were evaluated as probably hazardous.
Table 2

Results of job analysis and JSI on the patient's right hand and wrist

aoem-31-e2-i002
Group Tasks Working hours (day) JSI
1 Assembling left-hand luggage, wheel house, and seat belts 4 4.5 (3/1/1.5/1/1/1)
Installing left-hand knee air bag, door striker, and door trim 4 36 (3/2/3/2/1/1)
Installing left-hand tires and door scarf 4 27 (3/3/3/1/1/1)
Installing right-hand door trim, door striker, and rear door scarf 4 54 (3/3/3/2/1/1)
Assembling right-hand luggage, wheel house, and seatbelts 4 6.8 (3/1.5/1.5/1/1/1)
Installing right-hand tires and door scarf 4 6.8 (3/1.5/1.5/1/1/1)
2 Assembling left-hand front seat 2 6.8 (3/1.5/1.5/1/1/1)
Installing battery 2 1.1* (3/0.5/0.5/1.5/1/1)
Antifreeze and washer liquid injection and installing right-hand front seat 4 6 (3/2/1/1/1/1)
Connecting seat wire and torque checking 4 18 (3/2/3/1/1/1)
Loading front and rear windshield glasses (using a machine) 4 2.3* (3/1.5/0.5/1/1/1)
Installing steering wheel and air bag 4 9 (3/2/1.5/1/1/1)
3 Installing duct, spoiler and net hook 4 6 (3/2/1/1/1/1)
Installing air cleaner, battery cable, and duct 4 13.5 (3/2/1.5/1.5/1/1)
Installing cowl top cover, side cover and fixing spare tires 4 6.8 (3/1.5/1.5/1/1/1)
Installing tailgate panel, covering shelf trim and side trim 4 6.8 (3/1.5/1/1.5/1/1)
4 Installing upper cover and knob 2 12 (3/2/2/1/1/1)
Installing wipers 2 13.5 (3/2/1.5/1.5/1/1)
Installing tool set and rear wiper 2 1.5* (3/1/0.5/1/1/1)
Installing panel screw 2 9 (3/1.5/2/1/1/1)
Installing center garnish, tailgate upper trim and shelf side trim 4 20.3 (3/1.5/3/1.5/1/1)
Installing trunk garnish and transverse trim 4 54 (3/3/3/2/1/1)
Numbers in bold are total scores and detailed JSI scores are expressed in parentheses intensity of exertion, duration of exertion, efforts per minute, hand/wrist posture, speed of work, duration of task per day (hours) in order.
JSI: job strain index.
*Three points of JSI refer to probably safe; 5 points associated with distal upper extremity disorders; 7 points probably hazardous.
Additionally, most of the patient's tasks were using vibration tools. Among 12 tasks in the 2016 musculoskeletal risk factors survey, there were 2 tasks using a vibration tool for more than 2 hours and 4 tasks hammering with a hand more than 10 times per hour. In addition, there were 19 tasks using hand-arm vibration tools in the 22 task-related videos. Table 3 shows information of the vibration tools. The vibration acceleration of the tools could not be measured, so we could not calculate the cumulative vibration exposure. However, according to 2003 Korea Occupational Safety and Health Agency study, it is reported that about 16% of workers in the automobile manufacturing exceed 5m/s2 which is the exposure limit for European Union [19]. This case is also expected to be exposed to similar level. Considering his occupational history and the results of ergonomic evaluations, we determined that the EPL tendon rupture is highly correlated with the occupational exposure.
Table 3

Information of hand-arm vibration tools used at the work

aoem-31-e2-i003
Product name Weight (kg) Length (mm) Revolutions per minute Frequency (Hz)
UL-90 1.3 170 6,000 100
UL-70 0.95 153 5,700 95
EYF-LB2A 1.3 158 3,600 60

Ethics statement

Written informed consents were obtained from the patient for publication of this case report and any accompanying data.

DISCUSSION AND CONCLUSION

There are several major theories about the pathophysiological mechanism of EPL tendon rupture [41220]. The first theory is the rupture by hemodynamic factors. Since the area around Lister's tubercle is relatively narrow, it is easy to occur ischemia if the tendon sheath pressure increased [4]. Engkvist [20] performed micro-angiographic study and found that there was an avascular zone in the EPL tendon around Lister's tubercle that was nourished by diffusion from the synovial fluid. The second is the rupture by anatomical factors. Because EPL tendon turns sharply around the Lister's tubercle, it is vulnerable to increase pressure of the tendon sheath from trauma, fracture, and chronic inflammation, which may cause rupture of EPL tendon. The third is the inadequate biomechanical stress. Lloyd et al. [12] reported that in sports activities, improper hand and wrist posture cause excessive biomechanical force on EPL tendon so that degenerative changes occur by the tendon wear. In conclusion, EPL tendon rupture could be caused by the combination of hemodynamic, anatomical, and biomechanical factors.
The attritional rupture that generally occurs in the middle of the tendon is different from the high-energy rupture that occurs in the thinnest part of the tendon [15]. The EPL tendon rupture also occurred at the anatomical location near the Lister's tubercle which is the level corresponding to the attributional rupture. Particularly, considering the anatomical function of EPL tendons, extension of thumb and ulnar deviation which the patient usually take during work is probably harmful for the rupture. The orthopedic surgeon who performed the surgery also described that abrasion of the EPL tendon was observed in the surgical field and the disease is likely to be associated with the repetitive overuse of the hand and wrist. In addition, the patient used many hand-arm vibration tools while working. Hand-arm vibration can cause abnormalities in blood vessels, nerves, bones, joints and muscles, and cause localized blood flow disorders, which can lead to tendon wear [21]. The hand-arm vibration may also have affected some of the tendon rupture. However, there is a lack of research on the effects of local vibration on the tendon wear, so this needs to be supplemented by additional studies in the future.
The additional possible causes of the patient's illness can be considered. First, he developed a right third trigger finger in 2008, which may have affected the EPL tendon rupture. However, that accident was not a major injury such as a fracture, and the anatomical location of the disease is different. Second, his hobby was playing badminton. He played badminton for about 15 minutes a day in only 2007. Although it is known that EPL tendon rupture may occur in professional skiers, golfers and tennis players, it is unlikely that an ordinary person playing badminton for a short period of time as a hobby would have caused the disease. Lastly, the patient's blood test shows a slight increase in uric acid level but the other blood tests including C-reactive protein level were all with the normal ranges. Moreover, no abnormalities such as uric acid crystals (tophi) were found in the operation. Therefore, we assumed that the probability of rupture by gout is low. In conclusion, we determined the EPL tendon rupture was probably caused by repetitive motion and improper posture of the hand and wrist, and the hand-arm vibration is a possible cause as well.
In this study, we showed the general method of work-relevance evaluation conducted at an occupational and environmental medicine outpatient clinic. There is limitation in performing an ergonomic evaluation based on the task-related videos taken by the patient since the work place was not allowed to be visited due to the workplace regulation. However, we believe that this problem has been resolved through detailed job analysis and ergonomic evaluation.
We report that EPL tendons can be ruptured by improper posture and overuse of hand and wrist joints. The surveillance and follow-up management system should be established to prevent work-related musculoskeletal disorders (WMSDs). We also have to provide sufficient information about WMSDs and regular education for workers performing musculoskeletal burden work.

Abbreviations

EPL

extensor pollicis longus

JSI

job strain index

MRI

magnetic resonance imaging

WMSD

work-related musculoskeletal disorder

Notes

Competing interests The authors declare that they have no competing interests.

Authors contributions

  • Conceptualization: Park S, Kim J.

  • Data curation: Park S.

  • Investigation: Park S.

  • Writing - original draft: Park S.

  • Writing - review & editing: Kim J.

References

1. Netter FH. Atlas of human anatomy. 5th ed. Philadelphia: Saunders;2010.
2. Drake RL, Vogl AW, Mitchell AW. Gray's anatomy for student. 2nd ed. London: Churchill Livingstone;2009.
3. Hu CH, Fufa D, Hsu CC, Lin YT, Lin CH. Revisiting spontaneous rupture of the extensor pollicis longus tendon: eight cases without identifiable predisposing factor. Hand (N Y). 2015; 10(4):726–731.
crossref
4. Kim CH. Spontaneous rupture of the extensor pollicis longus tendon. Arch Plast Surg. 2012; 39(6):680–682.
crossref
5. Rivlin M, Fernández DL, Nagy L, Graña GL, Jupiter J. Extensor pollicis longus ruptures following distal radius osteotomy through a volar approach. J Hand Surg Am. 2016; 41(3):395–398.
crossref
6. Yoon SW, Hwang TS, An JI. Early rupture of the extensor pollicis longus tendon after fracture of the distal end of the radius: a case report. J Korean Soc Surg Hand. 1998; 3(1):102–106.
7. Hung JY, Wang SJ, Wu SS. Spontaneous rupture of extensor pollicis longus tendon with tophaceous gout infiltration. Arch Orthop Trauma Surg. 2005; 125(4):281–284.
crossref
8. Cigna E, Özkan Ö, Mardini S, Chiang PT, Yang CH, Chen HC. Late spontaneous rupture of the extensor pollicis longus tendon after corticosteroid injection for flexor tenosynovitis. Eur Rev Med Pharmacol Sci. 2013; 17(6):845–848.
9. Choi JC, Kim WS, Na HY, Lee YS, Song WS, Kim DH, et al. Spontaneous rupture of the extensor pollicis longus tendon in a tailor. Clin Orthop Surg. 2011; 3(2):167–169.
crossref
10. Fujita N, Doita M, Yoshikawa M, Fujioka H, Sha N, Yoshiya S. Spontaneous rupture of the extensor pollicis longus tendon in a professional skier. Knee Surg Sports Traumatol Arthrosc. 2005; 13(6):489–491.
crossref
11. Perugia D, Ciurluini M, Ferretti A. Spontaneous rupture of the extensor pollicis longus tendon in a young goalkeeper: a case report. Scand J Med Sci Sports. 2009; 19(2):257–259.
crossref
12. Lloyd TW, Tyler MP, Roberts AH. Spontaneous rupture of extensor pollicis longus tendon in a kick boxer. Br J Sports Med. 1998; 32(2):178–179.
crossref
13. Shifflett GD, Ek ET, Weiland AJ. Spontaneous rupture of the extensor pollicis longus in a break-dancer. Eplasty. 2014; 14:e4.
14. Wong TC, Chiu Y, Ip FK. Re: spontaneous rupture of the extensor pollicis longus tendon while playing video games. J Hand Surg Eur Vol. 2008; 33(2):225–226.
15. Gilman L, Cage DN, Horn A, Bishop F, Klam WP, Doan AP. Tendon rupture associated with excessive smartphone gaming. JAMA Intern Med. 2015; 175(6):1048–1049.
crossref
16. Korea Ministry of Government Legislation. Occupational safety and health act. 2017. Accessed 25 Apr 2019. http://www.law.go.kr/lsSc.do?tabMenuId=tab18&p1=&subMenu=1&nwYn=1&section=&tabNo=&query=산업안전보건법 시행규칙#undefined.
17. Moore JS, Garg A. The strain index: a proposed method to analyze jobs for risk of distal upper extremity disorders. Am Ind Hyg Assoc J. 1995; 56(5):443–458.
18. Korean Society of Occupational and Environmental Medicine. Occupational environmental medicine. Seoul: Gyechuk Munwhasa;2014.
19. Jang JK, Oh SY, Choi EJ. Assessment and control of noise and vibration generated from hand-arm power tools: focused on the vibration at impact wrench using operations in car service centers and automobile manufacturing industries. Ulsan: Korea Occupational Safety and Health Agency;2003.
20. Engkvist O, Lundborg G. Rupture of the extensor pollicis longus tendon after fracture of the lower end of the radius-a clinical and microangiographic study. Hand. 1979; 11(1):76–86.
21. The National Institute for Occupational Safety and Health. Occupational cancer. 2012. Accessed 25 Apr 2019. https://www.cdc.gov/niosh/topics/cancer.
TOOLS
ORCID iDs

Sunwook Park
https://orcid.org/0000-0001-7079-2865

Jungwon Kim
https://orcid.org/0000-0003-3836-8890

Similar articles