Abstract
PURPOSE
Surface finishing of a zirconia restoration is essential after clinical adjustment. Herein, we investigated the effects of a surface finishing protocol for monolithic zirconia on final roughness and bacterial adherence.
MATERIALS AND METHODS
Forty-eight disk-shaped monolithic zirconia specimens were fabricated and divided into four groups (n = 12) based on initial surface treatment, finishing, and polishing protocols: diamond bur+polishing bur (DP group), diamond bur+stone grinding bur+polishing bur (DSP group), no diamond bur+polishing bur (NP group), and no diamond bur+stone grinding bur+polishing bur (NSP group). Initial and final surface roughness was measured with a profilometer, and shown using scanning electron microscope. Bacterial adhesion was evaluated by quantifying Streptococcus mutans in the biofilm. Kruskal-Wallis and Mann-Whitney U tests were used to compare results among groups, and two-way analysis of variance was used to evaluate the effects of grinding burs on final roughness (α=.05).
RESULTS
The DP group had the highest final Ra value, followed by the DSP, NP, and NSP groups. Use of the stone grinding bur as a coarse-finishing step significantly decreased final Ra values when a diamond bur was used (P<.001). Omission of the stone grinding bur increased biofilm formation on specimen surfaces. Combining a stone grinding bur with silicone polishing burs produced the smallest final biofilm values, regardless of the use of a diamond bur in initial surface treatment.
Monolithic zirconia restorations are alternatives to layered zirconia restorations because of their decreased potential for chipping of the porcelain veneer.1 In a monolithic zirconia restoration, zirconia is directly exposed to the oral environment and must be polished following occlusal and axial adjustments.2 Surface smoothing of dental restorations is essential for reducing plaque accumulation, improving patient comfort, preventing wear of the antagonist enamel, and improving the aesthetics of restorations.3456 The effectiveness of a finishing and polishing system on dental material is evaluated by measuring the achieved surface roughness.2 Restorations with surface roughness values > 0.2 µm (Ra) could trigger bacterial plaque accumulation, which is the primary cause of gingival inflammation and secondary caries.5 Bacteria adhere to restorations and natural teeth through a four-phase process.78 The initial phase begins with transport of bacteria toward the surface. In the second phase, bacteria adhere to the surface through a combination of Van der Waals forces and electrostatic repulsive forces. The intermediate attachment phase involves the adherence of bacteria to complementary sites on the substrate surface. In the final phase, bacteria colonize on the surface and form a biofilm via proliferation of already-colonized bacteria and/or by continuous adhesion of additional salivary bacteria. Initial adhesion of bacteria to the tooth surface is a critical step in bacterial plaque formation.9 The irregular geometry of a rough surface shelters bacteria from shear forces, giving them more time to interact with the surface and establish strong adhesion.79
Monolithic zirconia restoration fabricated from a solid block of zirconia has better mechanical properties and superior fracture strength than bi-layered restorations due to the uniform structure.1011 The high strength and hardness of zirconia require specific surface treatment methods.112 Coarse-grit and fine-grit diamond rotary burs are often used at high speed for polishing monolithic zirconia13 because diamond burs are effective for extensive grinding of zirconia. Ho et al.13 stated that the use of diamond bur increased the flexural strength of zirconia, whereas Kosmac et al.14 concluded that use of the coarse diamond bur reduced the strength of the material due to surface flaws and microcracks. Therefore, specific zirconia finishing and polishing systems that incorporate instruments with improved diamond particle coatings have been developed.15 Use of zirconia-specific grinding burs are associated with higher grinding efficiency and lower heat generation than conventional stone burs.16
There have been reports in the literature on the importance of using specific stone burs on zirconia.16 However, the effects of stone burs in relation to use of different initial surface treatments on final roughness have not been fully clarified. The purpose of the present study was to examine whether use of diamond and stone burs on zirconia affects its final roughness and bacterial adhesion properties. The null hypothesis was that the surface grinding protocol for zirconia does not influence the final roughness or bacterial biofilm formation.
Figure 1 presents the study design. Forty-eight disk-shaped monolithic zirconia specimens were designed using computer software (CATIA V5R19, Dassault Systemes, Velizy-Villacoublay, France) and were manufactured with a 5-axis milling machine (Ceramill Motion 2, Amann Girrbach, Koblach, Austria) using zirconium dioxide blocks (Prettau, Zirkonzhan, Bruneck, Italy). Afterwards, sintering process of specimens was conducted using a dedicated sintering furnace (Zirkonofen 600/V2, Zirkonzahn). For the initial surface treatment, 24 specimens (15 mm in diameter, 8 mm in thickness) were randomly selected and ground for 10 s under water-cooling conditions with a coarse-grit diamond bur (V847KR, Edenta AG, Au, Switzerland) using an electronic high-speed handpiece (Ti-Max Z95L, NSK, Tokyo, Japan) to simulate the initial clinical adjustment. The surfaces of the remaining 24 specimens were not subjected to diamond bur adjustment. For the finishing step, half of the specimens in each group were ground with a stone bur. The specimens were then divided into four groups (n = 12), based on the initial treatment, finishing, and polishing protocols: diamond bur + polishing bur (DP group), diamond bur + stone grinding bur + polishing bur (DSP group), no diamond bur + polishing bur (NP group), no diamond bur + stone grinding bur + polishing bur (NSP group). After the coarse diamond bur grinding, finishing and polishing procedures, the specimens were cleaned by ultrasonication for 10 minutes in sterile distilled water, air blown, and stored dry at room temperature. All finishing and polishing procedures were performed by one operator using the Edenta system (Magic KIT Zir, Edenta GmbH, Lustenau, Austria) and a low-speed electronic handpiece (KaVo EXPERTmatic E10 C, KaVo, Biberach, Germany) with backward movement at 20 seconds per step, in accordance with the manufacturers' instructions. The instruments' codes and revolutions per minute used for surface treatments in this study are presented in Table 1. A microscope (MM 200, Nikon Corp., Tokyo, Japan) was used to observe the various sizes of natural diamond particles impregnated into instruments at × 300 magnification (Fig. 2).
The resulting surface roughness was measured with a contact surface profilometer (Surftest SV-400, Mitutoyo, Kawasaki, Japan) under a constant load of 4 mN at a speed of 0.25 mm/s and a measurement range of 0.8 mm. The Ra value of each specimen was determined by averaging nine measurements: three repetitions of three traces.
Streptococcus mutans (ATCC 25175) was used to assess biofilm formation. S. mutans was maintained in a brain heart infusion (BHI) medium and grown under aerobic conditions. An in vitro biofilm formation assay was performed in accordance with published protocol.17 The specimens were cleaned with 70% alcohol and sterilized by UV light for 1 hour before the biofilm formation test. Briefly, S. mutans colonies were inoculated into BHI-1% sucrose broth and incubated overnight. The culture broth was inoculated into 2 mL of the same liquid medium to reach 1% volume/volume in a 12-well polystyrene plate containing each specimen. After incubation for 16 hours, the streptococcal broth was removed, and the specimens were washed three times with sterile phosphate buffered saline solution to remove loosely attached biomass. For biofilm quantification, 200 µL of crystal violet solution (0.2 % w/v in 10% ethanol) was added to each specimen, followed by incubation for 1 hour. After washing with phosphate-buffered saline solution three times, the specimen was air-dried. Crystal violet retained by the streptococcal biofilm was redissolved in 200 µL acidic solvent (10% acetic acid in distilled water); the absorbance was determined with a microplate reader (Molecular Devices, San Jose, CA, USA) at 595 nm.18
For scanning electron microscope (SEM) analysis, the specimens were attached to an aluminum metal platform with a double sided adhesive tape. Then the edges of the specimens were painted with carbon paint (Pelco Colloidal Graphite, Ted Pella, Redding, CA, USA). After coating the specimen with spotted platinum with ion sputter (E-1030, Hitachi, Tokyo, Japan), they were analyzed with SEM (SU8230, Hitachi) at ×200 magnification.
All statistical analyses were conducted using the IBM SPSS Statistics v22.0 statistical software package (IBM Corp., Armonk, NY, USA). Surface roughness for each group was expressed as mean ± standard deviation. Kruskal-Wallis and Mann-Whitney U tests were used to compare the effects of stone grinding bur use among all subgroups. Two-way analysis of variance (ANOVA) was performed to investigate relationships between surface preparation and use of a stone grinding bur. Results were visualized using interaction plots. Statistical significance was set at P < .05.
The initial surface roughness values were Ra = 1.07 µm for the diamond bur-treated group and Ra = 0.42 µm for the non-treated group. Table 2 presents the roughness of zirconia specimens by surface treatment. In the initial measurements, the use of the diamond bur at high speed significantly increased Ra values. After different finishing and polishing protocols, the DP group had the highest final Ra value, followed by the DSP, NP, and NSP groups. Addition of a finishing step using a stone grinding bur significantly decreased the final Ra values for diamond bur-treated specimens; however, the effect was not statistically significant when the specimens had not been treated with the diamond bur (P = .70). Two-way ANOVA revealed a strong interaction between the use of the diamond bur in the initial surface treatment and the use of the stone grinding bur in the finishing step on the final Ra (P < .001) (Table 3).
In vitro streptococcal biofilm masses on the surfaces of the specimens, as determined by crystal violet staining, were compared (Fig. 3). In general, biofilm formation of S. mutans significantly increased on the surfaces of specimens treated with the diamond bur, especially when use of a stone grinding bur was omitted (P < .001). The combination of a stone grinding bur and a silicone polishing bur produced small final biofilm mass.
For SEM images, the specimen treated with a diamond bur alone showed sharp groove patterns (Fig. 4A), as opposed to the other specimens (Fig. 4B, 4C). The specimen of DSP group showed more evenness of the surface compared to rounded edges of the large grooves of DP group (Fig. 4B, 4C).
This study was conducted to evaluate the effects of surface finishing of monolithic zirconia with a coarse stone grinding bur on final surface roughness and bacterial adhesion. Based on our results, the null hypothesis was rejected because the final surface roughness and biofilm formation were significantly different, depending on the coarse-finishing protocols used.
A zirconia-specific stone grinding bur was used in this study in a coarse-finishing step for specimens with different initial surface roughness values. When initial surface treatment is performed using a high-speed diamond bur on monolithic zirconia specimens, a very rough surface is produced. The finishing and polishing procedure is used to achieve a smooth and regular surface for the restoration. However, deep scratches created by the diamond bur are difficult to remove with silicone polishing burs because of the extreme strength and hardness of zirconia material. Finishing and polishing instruments comprise of three major components: primary abrasive, supplemental abrasive, and abrasive-fixing substance. Among these, the primary abrasive is the main factor determining the grinding efficiency.11 Since zirconia has a value of 9 on the Mohs hardness scale, diamond grinding burs for occlusal adjustment have been manufactured using a coarse diamond grain size and serve as the primary abrasive.16 Silicone polishing burs, on the other hand, contain very fine diamond grains; thus, these burs exhibit significantly lower grinding efficiency. Therefore, use of a stone grinding bur may be considered an important intermediate step in filling the gap between the extremely rough surface of the diamond bur and the fine surfaces of silicone polishing burs. Previous studies have reported that use of zirconia stone grinding burs for zirconia materials plays an important role in removing deep grooves and achieving a finer surface texture for subsequent polishing steps.16 Therefore, addition of a coarse-finishing step using a stone grinding bur is essential and should not be omitted in clinical practice, particularly after extensive reduction of the zirconia restoration is accomplished with a coarse-grit diamond bur.
Surface roughness is considered the most important factor in oral biofilm formation.9 A correlation between surface roughness and bacterial adhesion was also observed in this study. Biofilm formation was substantially reduced after stone grinding, independent of whether specimens had been roughed by diamond burs. Interestingly, when use of the stone grinding bur was omitted, use of silicone polishing burs alone increased the biofilm thickness in specimens treated with a diamond bur. This phenomenon may be explained by the surface topography of treated zirconia (Fig. 4, Fig. 5). The initial surface treatment process that used a coarse-grit diamond bur generated deep, sharp grooves on the surface. The silicone bur is not suitable for grinding irregular macrostructures because of the low hardness and fine grit of the diamond particles in the instrument. Moreover, silicone burs cannot reach the inner sides of the narrow deep grooves, but they can be used to round the sharp outer edges of these grooves. Although this partial surface alteration generally decreases the Ra value of polished zirconia, this surface structure may provide more favorable conditions for bacterial adhesion. Han et al.19 also reported the similar bactericidal effects in the surface with sharp grooves and pits. These results confirm the clinical importance of sequential finishing and polishing regimens.
There are various clinical and technical factors that determine the final roughness of zirconia. The roles of various polishing systems and sintering processes in the final roughness of zirconia need to be evaluated in future studies.2021 Moreover, the effects of grinding direction, time and pressure, and use of water coolants are also important clinical factors that require further investigation.
Within the limitations of this study, a coarse-finishing step using a stone grinding bur significantly decreased the final Ra values of monolithic zirconia when the surface had been roughed by a diamond bur. Biofilm formation of S. mutans increased on the surfaces of specimens treated with a diamond bur, especially when use of a stone grinding bur was omitted.
References
1. Caglar I, Ates SM, Yesil Duymus Z. The effect of various polishing systems on surface roughness and phase transformation of monolithic zirconia. J Adv Prosthodont. 2018; 10:132–137. PMID: 29713434.
2. Chavali R, Lin CP, Lawson NC. Evaluation of different polishing systems and speeds for dental zirconia. J Prosthodont. 2017; 26:410–418. PMID: 26618785.
3. Kim HK, Kim SH, Lee JB, Ha SR. Effects of surface treatments on the translucency, opalescence, and surface texture of dental monolithic zirconia ceramics. J Prosthet Dent. 2016; 115:773–779. PMID: 26809221.
4. Kim MJ, Oh SH, Kim JH, Ju SW, Seo DG, Jun SH, Ahn JS, Ryu JJ. Wear evaluation of the human enamel opposing different Y-TZP dental ceramics and other porcelains. J Dent. 2012; 40:979–988. PMID: 22892464.
5. Teughels W, Van Assche N, Sliepen I, Quirynen M. Effect of material characteristics and/or surface topography on biofilm development. Clin Oral Implants Res. 2006; 17(Suppl 2):68–81. PMID: 16968383.
6. Jones CS, Billington RW, Pearson GJ. The in vivo perception of roughness of restorations. Br Dent J. 2004; 196:42–45. PMID: 14966503.
7. Yuzugullu B, Celik C, Burak Ozcelik T, Erkut S, Yurdakul P, Ocal Y, Sener B. The effect of different polishing sequences on the adhesion of Streptococcus mutans to feldspathic Porcelain. J Adhes. 2016; 92:939–949.
8. Bollen CM, Lambrechts P, Quirynen M. Comparison of surface roughness of oral hard materials to the threshold surface roughness for bacterial plaque retention: a review of the literature. Dent Mater. 1997; 13:258–269. PMID: 11696906.
9. Lee BC, Jung GY, Kim DJ, Han JS. Initial bacterial adhesion on resin, titanium and zirconia in vitro. J Adv Prosthodont. 2011; 3:81–84. PMID: 21814616.
10. Miyazaki T, Nakamura T, Matsumura H, Ban S, Kobayashi T. Current status of zirconia restoration. J Prosthodont Res. 2013; 57:236–261. PMID: 24140561.
11. Huh YH, Park CJ, Cho LR. Evaluation of various polishing systems and the phase transformation of monolithic zirconia. J Prosthet Dent. 2016; 116:440–449. PMID: 27061631.
12. Preis V, Grumser K, Schneider-Feyrer S, Behr M, Rosentritt M. The effectiveness of polishing kits: influence on surface roughness of zirconia. Int J Prosthodont. 2015; 28:149–151. PMID: 25822299.
13. Ho CM, Ding H, Chen X, Tsoi JK, Botelho MG. The effects of dry and wet grinding on the strength of dental zirconia. Ceram Int. 2018; 44:10451–10462.
14. Kosmac T, Oblak C, Jevnikar P, Funduk N, Marion L. Strength and reliability of surface treated Y-TZP dental ceramics. J Biomed Mater Res. 2000; 53:304–313. PMID: 10898871.
15. Kosmac T, Oblak C, Jevnikar P, Funduk N, Marion L. The effect of surface grinding and sandblasting on flexural strength and reliability of Y-TZP zirconia ceramic. Dent Mater. 1999; 15:426–433. PMID: 10863444.
16. Lee KR, Choe HC, Heo YR, Lee JJ, Son MK. Effect of different grinding burs on the physical properties of zirconia. J Adv Prosthodont. 2016; 8:137–143. PMID: 27141258.
17. Gilan I, Sivan A. Extracellular DNA plays an important structural role in the biofilm of the plastic degrading actinomycete Rhodo-coccus ruber. Adv Microbiol. 2013; 3:543–551.
18. O'Toole GA. Microtiter dish biofilm formation assay. J Vis Exp. 2011; 47:2437.
19. Han A, Tsoi JKH, Matinlinna JP, Chen Z. Influence of grit-Blasting and hydrofluoric acid etching treatment on surface characteristics and biofilm formation on zirconia. Coatings. 2017; 7:130.
20. Kim HK, Kim SH. Comparison of the optical properties of pre-colored dental monolithic zirconia ceramics sintered in a conventional furnace versus a microwave oven. J Adv Prosthodont. 2017; 9:394–401. PMID: 29142648.
21. Goo CL, Yap A, Tan K, Fawzy AS. Effect of polishing systems on surface roughness and topography of monolithic zirconia. Oper Dent. 2016; 41:417–423. PMID: 26666390.
Table 1
Category | Diamond bur | Stone grinding bur | Silicone polishing bur | Fine silicone polishing bur |
---|---|---|---|---|
Instrument codes* | V847KR | 8001.050.HP | 3041.HP | 30041.HP |
Revolutions per minute | 200.000 | 12.500 | 20.000 | 10.000 |