Journal List > J Korean Soc Surg Hand > v.21(3) > 1106526

Sung, Song, and Lee: Modified Bouquet Technique for Treatment of Metacarpal Neck Fractures

Abstract

Purpose:

The purpose of this study was to report the clinical outcome of “modified Bouquet technique”, as a simple and effective internal fixation with Kirschner-wire for the metacarpal neck fractures.

Methods:

Sixty-seven patients with metacarpal neck fracture treated by modified Bouquet technique were retrospectively reviewed. The operation time and removal time were evaluated. For radiologic evaluation, posterior angulation of fracture and metacarpal shortening were measured pre and postoperatively. For clinical evaluation, range of motion of metacarpophalangeal joint, Green and O'Brien score were evaluated.

Results:

Preoperative neck shaft angle of metacarpal bone was 46.0° and length of metacarpal bone was 51.2 mm, and postoperative neck shaft angle was 24.4° (p=0.003) and length of metacarpal length was 52.8 mm (p=0.031) in average. The mean range of motion was 86.6° and Green and O'Brien score was 96.1 points at last visit. We had one complicated case with type II complex regional pain syndrome of affected hand with hypertrophic scar formation.

Conclusion:

Modified Bouquet technique for metacarpal neck fracture is a good method using just two K-wires, plier and mallet without electric devices in short operation time. The technique can correct angulation of fracture site, rotation of finger and metacarpal shortening by controlling inserted K-wires with high bone union rate with less joint stiffness.

REFERENCES

1. Day CS, Stern PJ. Fracture of the metacarpals and phalanges. Green DP, Hotchkiss RN, Pederson WC, editors. Green's operative hand surgery. 6th ed. Philadelphia: Elsevier;2010. p. 241–5.
2. Jones WW. Biomechanics of small bone fixation. Clin Orthop Relat Res. 1987; (214):11–8.
3. Gonzalez MH, Hall RF Jr. Intramedullary fixation of metacarpal and proximal phalangeal fractures of the hand. Clin Orthop Relat Res. 1996; (327):47–54.
4. Opgrande JD, Westphal SA. Fractures of the hand. Orthop Clin North Am. 1983; 14:779–92.
crossref
5. Lord RE. Intramedullary fixation of metacarpal fractures. J Am Med Assoc. 1957; 164:1746–9.
crossref
6. Gonzalez MH, Igram CM, Hall RF Jr. Flexible intramedullary nailing for metacarpal fractures. J Hand Surg Am. 1995; 20:382–7.
crossref
7. Foucher G. “Bouquet” osteosynthesis in metacarpal neck fractures: a series of 66 patients. J Hand Surg Am. 1995; 20(Pt 2):S86–90.
crossref
8. Faraj AA, Davis TR. Percutaneous intramedullary fixation of metacarpal shaft fractures. J Hand Surg Br. 1999; 24:76–9.
crossref
9. Orbay J. Intramedullary nailing of metacarpal shaft fractures. Tech Hand Up Extrem Surg. 2005; 9:69–73.
crossref
10. Grundberg AB. Intramedullary fixation for fractures of the hand. J Hand Surg Am. 1981; 6:568–73.
crossref
11. Choi SJ, Chang SK. Treatment method of the metacarpal bone fractures with retrograde percutaneous intramedullary K-wire fixation to decrease the injury of extensor tendo. J Korean Soc Surg Hand. 2004; 9:117–22.
12. Chung NS, Sim JC, Hong KD, Ha SS, Kang JH, Park SJ. Intramedullary pin fixation of metacarpal fractures reduced percutaneusly by Towel Clip. J Korean Soc Surg Hand. 2005; 10:39–44.
13. Birndorf MS, Daley R, Greenwald DP. Metacarpal fracture angulation decreases flexor mechanical efficiency in human hands. Plast Reconstr Surg. 1997; 99:1079–83.
crossref
14. Kim BS, Cho SD, Cho YS, et al. Operative treatment of metacarpal shaft fracture. J Korean Soc Fract. 1999; 12:720–6.
crossref
15. Choi SJ, Lee YH, Chang HG, Lee CJ, Cho WH. The 5th metacarpal neck fracture treated by closed reduction and percutaneous intramedullary K-wire fixation. J Korean Soc Fract. 1995; 8:696–704.
16. Foucher G, Chemorin C, Sibilly A. A new technic of osteosynthesis in fractures of the distal 3d of the 5th metacarpus. Nouv Presse Med. 1976; 5:1139–40.
17. Manueddu CA, Della Santa D. Fasciculated intramedullary pinning of metacarpal fractures. J Hand Surg Br. 1996; 21:230–6.
crossref
18. Wong TC, Ip FK, Yeung SH. Comparison between percutaneous transverse fixation and intramedullary k-wires in treating closed fractures of the metacarpal neck of the little finger. J Hand Surg Br. 2006; 31:61–5.
crossref
19. Han SH, Cho DY, Yoon HK, Shin DE, Kim JH, Kim JH. Reduction of 5th metacarpal neck fractures using modified pin leverage technique. J Korean Hand Soc. 2004; 9:68–72.
20. Moon CS, Jeon HS, Jeon SJ, Seo YR, Noh HK. Treatment of metacarpal shaft fractures with retrograde intramedullary kirschner-wire fixation. J Korean Soc Surg Hand. 2010; 15:1–7.

Fig. 1.
Surgical instruments: one 1.6 mm K-wire, two 1.25 mm K-wires, plier, mallet and wire-cutter.
jkssh-21-137f1.tif
Fig. 2.
Surgical procedure. (A) Insert 1.6 mm K-wire to make entry hole for insertion of prebent K-wires at dorsoulnar aspect of metacarpal base. (B) Rotate the K-wire for widening the hole. (C) Two 1.25 mm K-wires were prebent before insertion. (D) Inserted prebent K-wire through the hole using plier and mallet. (E) Advance two K-wires distally. (F) Reduce the fracture site by rotating K-wires. (G) Cut K-wires as short as possible to bury the tips beneath skin.
jkssh-21-137f2.tif
Fig. 3.
A 65-year-old male patient with right hand pain (A) Initial anteroposterior and oblique plain X-ray show oblique fracture of 5th metacarpal neck. (B) After fixation by modified Bouquet technique, fracture is reduced successfully. (C) Plain radiographs in postoperative 7 weeks show nearly complete union state with normal length and shape.
jkssh-21-137f3.tif
Table 1.
Retrospective data of patients
Variable
Age (yr) 32 (18-70)
Sex (male:female) 66:1
Right:left:both 54:10:3
Injury mechanism (case)
Direct blow 50
Fall 16
Machine injury 1
K-wire removal period (day) 36.9
Follow-up period (wk) 11.1
Dorsal angulation (°)
Preoperative 46.0 (10.2-70.5)
Postoperative 24.4 (5.1-47.4)
Metacarpal length (mm)
Preoperative 51.27 (42.55-65.86)
Postoperative 52.79 (44.36-68.02)
Final range of motion (°) 0-86.6