Journal List > J Korean Fract Soc > v.31(3) > 1099130

Lee, Lee, Song, Choi, and Park: A Comparison of the Results between Internal Fixation and External Fixation in AO C Type Distal Radius Fractures

Abstract

Purpose

The purpose of this study was to evaluate the radiological and clinical results of plate fixation and external fixation with additional devices for treating distal radius fracture in AO type C subtypes, and propose a treatment method according to the subtypes.

Materials and Methods

Two hundred and one AO type C distal radius fracture patients were retrospectively reviewed. Eighty-five patients in group 1 were treated with volar or dorsal plate, and 116 patients in group 2, were treated with external fixation with additional fixation devices. Clinical (range of mtion, Green and O’Brien's score) and radiological outcomes were evaluated.

Results

At the 12-month follow-up, group 1 showed flexion of 64.4o, extension of 68.3o, ulnar deviation of 30.6o, radial deviation of 20.8o, supination of 76.1o, and pronation of 79.4o in average; group 2 showed flexion of 60.5o, extension of 66.9o, ulnar deviation of 25.5o, radial deviation of 18.6o, supination of 73.5o, and pronation of 75.0o in average. The mean Green and O’Brien score was 92.2 in group 1 and 88.6 in group 2. The radial height of group 1 and group 2 was 11.6/11.4 mm; radial inclination was 23.2o/ 22.5o; volar tilt was 11.6o/ 8.7o; and the ulnar displacement was 1.27/0.93 mm.

Conclusion

Judicious surgical techniques during device application and tips for postoperative management during external fixation can produce similar clinical results compared with internal fixation patients.

References

1. Singer BR, McLauchlan GJ, Robinson CM, Christie J. Epidemiology of fractures in 15,000 adults: the influence of age and gender. J Bone Joint Surg Br. 80:243–248. 1998.
2. Mattila VM, Huttunen TT, Sillanpää P, Niemi S, Pihlajamäki H, Kannus P. Significant change in the surgical treatment of distal radius fractures: a nationwide study between 1998 and 2008 in Finland. J Trauma. 71:939–942. discussion 942–943,. 2011.
crossref
3. Cooney WP. External fixation of distal radial fractures. Clin Orthop Relat Res. 180:44–49. 1983.
crossref
4. Kapoor H, Agarwal A, Dhaon BK. Displaced intraarticular fractures of distal radius: a comparative evaluation of results following closed reduction, external fixation and open reduction with internal fixation. Injury. 31:75–79. 2000.
crossref
5. Kapandji A. Intrafocal pinning of fractures of the distal end of the radius 10 yeasr later. Ann Chir Main. 6:57–63. 1987.
6. Penning D, Gausepohl T. External fixation of the wrist. Injury. 27:1–15. 1996.
crossref
7. Leung F, Tu YK, Chew WY, Chow SP. Comparison of external and percutaneous pin fixation with plate fixation for intraarticular distal radial fractures. A randomized study. J Bone Joint Surg Am. 90:16–22. 2008.
8. Xie X, Xie X, Qin H, Shen L, Zhang C. Comparison of internal and external fixation of distal radius fractures. Acta Orthop. 84:286–291. 2013.
crossref
9. Wang J, Yang Y, Ma J, et al. Open reduction and internal fixation versus external fixation for unstable distal radial fractures: a metaanalysis. Orthop Traumatol Surg Res. 99:321–331. 2013.
crossref
10. Esposito J, Schemitsch EH, Saccone M, Sternheim A, Kuzyk PR. External fixation versus open reduction with plate fixation for distal radius fractures: a metaanalysis of randomised controlled trials. Injury. 44:409–416. 2013.
crossref
11. Hegeman JH, Oskam J, Vierhout PA, Ten Duis HJ. External fixation for unstable intraarticular distal radial fractures in women older than 55 years. Acceptable functional end results in the majority of the patients despite significant secondary displacement. Injury. 36:339–344. 2005.
12. Zollinger PE, Kreis RW, van der Meulen HG, van der Elst M, Breederveld RS, Tuinebreijer WE. No higher risk of CRPS after external fixation of distal radial fractures-subgroup analysis under randomised vitamin C prophylaxis. Open Orthop J. 4:71–75. 2010.
13. Roh YH, Lee BK, Baek JR, Noh JH, Gong HS, Baek GH. A randomized comparison of volar plate and external fixation for intraarticular distal radius fractures. J Hand Surg Am. 40:34–41. 2015.
14. Shukla R, Jain RK, Sharma NK, Kumar R. External fixation versus volar locking plate for displaced intraarticular distal radius fractures: a prospective randomized comparative study of the functional outcomes. J Orthop Traumatol. 15:265–270. 2014.
crossref
15. Margaliot Z, Haase SC, Kotsis SV, Kim HM, Chung KC. A metaanalysis of outcomes of external fixation versus plate osteosynthesis for unstable distal radius fractures. J Hand Surg Am. 30:1185–1199. 2005.
crossref
16. Brogan DM, Richard MJ, Ruch D, Kakar S. Management of severely comminuted distal radius fractures. J Hand Surg Am. 40:1905–1914. 2015.
crossref
17. Gausepohl T, Pennig D, Mader PK. Principles of external fixation and supplementary techniques in distal radius fractures. Injury, 31 Suppl. 1:56–70. 2000.
crossref
18. Capo JT, Rossy W, Henry P, Maurer RJ, Naiu S, Chen L. External fixation of distal radius fractures: effect of distraction and duration. J Hand Surg Am. 34:1605–1611. 2009.
crossref
19. Weber SC, Szabo RM. Severely comminuted distal radial fracture as an unsolved problem: complications associated with external fixation and pins and plaster techniques. J Hand Surg Am. 11:157–165. 1986.
crossref
20. McQueen MM, Michie M, Court-Brown CM. Hand and wrist function after external fixation of unstable distal radial fractures. Clin Orthop Relat Res. 285:200–204. 1992.
crossref

Fig. 1.
(A) Plain radiograph and computed tomography showing intraarticular fracture (AO type C2). (B) Internal fixation with volar locking plate by anterior approach. (C) Twelve months after operation, volar tilt was restored with good articular congruency.
jkfs-31-87f1.tif
Fig. 2.
(A) Anteroposterior plain radiograph showing intraarticular distal radius fracture. (B) Sagittal view of computed tomography showing AO type C1 fracture. (C, D) Fracture was reduced and fixed by external fixation with intrafocal and interfragmentary pinnings for the fracture. (E) At the time of the most recent follow-up, there was good radiological results.
jkfs-31-87f2.tif
Fig. 3.
(A, B) Anteroposterior and lateral radiographs of the wrist showed severe comminution of metaphysis and intraarticular extension of fracture line. (C) External fixator was applied for ligamentotatic effect and internal fixation was done with autogenous iliac bone graft for bone defect area. (D) At the time of 4 months postoperatively, solid union was obtained with a Green and O’Brien score of 93.
jkfs-31-87f3.tif
Table 1.
Range of Motion
Variable Group 1 Group 2 p-value
3 months 12 months 3 months 12 months 3 months 12 months
Flexion (o) 53.4 (30–60) 64.4 (30–85) 48.6 (30–60) 60.5 (25–80) 0.032 0.245
Extension (o) 65.2 (30–75) 68.3 (30–90) 61.5 (30–75) 66.9 (30–85) 0.043 0.072
Ulnar deviation (o) 25.7 (5–35) 30.6 (5–45) 23.2 (5–35) 25.5 (5–45) 0.612 0.515
Radial deviation (o) 16.4 (5–30) 20.8 (5–35) 14.3 (5–30) 18.6 (5–30) 0.725 0.837
Supination (o) 72.3 (40–90) 76.1 (40–90) 68.7 (40–80) 73.5 (40–90) 0.063 0.185
Pronation (o) 69.3 (40–80) 79.4 (40–90) 63.7 (40–80) 75.0 (40–90) 0.482 0.225

Values are presented as mean (range). Group 1 were treated with volar or dorsal plate. Group 2 were treated with external fixation with additional fixation device.

Table 2.
Functional Outcomes
Green and O’Brien's score Group 1 Group 2 p-value
3 months 12 months 3 months 12 months 3 months 12 months
Pain (0–25) 21.1 (15–25) 21.9 (15–25) 20.9 (15–25) 21.5 (15–25)
Range of motion (5–25) 20.9 (5–25) 21.4 (10–25) 20.1 (5–25) 20.3 (10–25)
Occupation (0–25) 19.8 (15–25) 20.1 (15–25) 19.4 (10–25) 19.7 (15–25)
Grip power (0–10) 6.4 (5–10) 6.7 (5–10) 5.9 (5–10) 6.0 (5–10)
X-ray (0–25) 20.9 (15–25) 22.1 (20–25) 20.1 (15–25) 21.1 (15–25)
Total 89.1 92.2 86.4 88.6 0.028 0.078

Values are presented as mean (range). Group 1 were treated with volar or dorsal plate. Group 2 were treated with external fixation with additional fixation device.

Table 3.
Radiological Outcomes
Radiologic parameter Group 1 Group 2 p-value
Radial length (mm) 11.6±2.17 11.4±2.27 0.627
Radial inclination (o) 23.2±3.78 22.5±2.94 0.353
Volar tilt (o) 11.6±3.20 8.7±3.20 0.002
Ulnar variance (mm) 1.27±1.49 0.93±2.05 0.399

Values are expressed as mean±standard deviation. Group 1 were treated with volar or dorsal plate. Group 2 were treated with external fixation with additional fixation device.