Abstract
The modern radiotherapy technique which delivers a large amount of dose to patients asks to confirm the positions of patients or tumors more accurately by using X-ray projection images of high-definition. However, a rapid increase in patient's exposure and image information for CT image acquisition may be additional burden on the patient. In this study, by introducing structural similarity (SSIM) index that can effectively extract the structural information of the image, we analyze the differences between daily acquired x-ray images of a patient to verify the accuracy of patient positioning. First, for simulating a moving target, the spherical computational phantoms changing the sizes and positions were created to acquire projected images. Differences between the images were automatically detected and analyzed by extracting their SSIM values. In addition, as a clinical test, differences between daily acquired x-ray images of a patient for 12 days were detected in the same way. As a result, we confirmed that the SSIM index was changed in the range of 0.85∼1 (0.006∼1 when a region of interest (ROI) was applied) as the sizes or positions of the phantom changed. The SSIM was more sensitive to the change of the phantom when the ROI was limited to the phantom itself. In the clinical test, the daily change of patient positions was 0.799∼0.853 in SSIM values, those well described differences among images. Therefore, we expect that SSIM index can provide an objective and quantitative technique to verify the patient position using simple x-ray images, instead of time and cost intensive three-dimensional x-ray images.
References
1. Paquin D, Levy D, Xing D. Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy. Med phys. 36:4–11. 2009.
2. Yeung AR, Li JG, Shi W, Newlin HE, et al. Tumor localization using cone-beam CT reduces setup margins in conventionally fractionated radiotherapy for lung tumors. Int J Radiat Oncol Biol Phys. 74:1100–1107. 2009.
3. Elstrom UV, Wysocka BA, Muren LP, et al. Daily kV cone-beam CT and deformable image registration as a method for studying dosimetric consequences of anatomic changes in adaptive IMRT of head and neck cancer. Acta oncologica. 49:1101–1108. 2010.
4. Ost P, De Meerleer G, De Gersem W, et al. Analysis of prostate bed motion using daily cone-beam computed tomography during postprostatectomy radiotherapy. Int J Radiat Oncol Biol Phys. 79:188–194. 2011.
5. Veiga C, McClelland J, Moinuddin S, et al. Toward adaptive radiotherapy for head and neck patients: Feasibility study on using CT-to-CBCT deformable registration for “dose of the day” calculations. Med Phys. 41:031703. 2014.
6. Wang Z, Bovik AC, Sheikh HR, et al. Image quality assessment: from error visibility to structural similarity. IEEE Trans Imag Proc. 13:600–612. 2004.
7. Brunet D, Vrscay ER, Wang Z. On the mathematical properties of the structural similarity index. IEEE Trans Imag Proc. 21:1488–1499. 2012.
8. Chai L, Sheng Y. Optimal design of multichannel equalizers for the structural similarity index. IEEE Trans Imag Proc. 23:5626–5637. 2014.
9. Channappayya SS, Bovik AC, Caramanis C, et al. Design of linear equalizers optimized for the structural similarity index. IEEE Trans Imag Proc. 17:857–872. 2008.
10. Channappayya SS, Bovik AC, Heath RW Jr.Rate bounds on SSIM index of quantized images. IEEE Trans Imag Proc. 17:1624–1639. 2008.
11. Charrier C, Knoblauch K, Maloney LT. Optimizing multiscale SSIM for compression via MLDS. IEEE Trans Imag Proc. 21:4682–4694. 2012.
12. Kolaman A, Yadid-Pecht O. “Quaternion structural similarity: a new quality index for color images. IEEE Trans Imag Proc. 21:1526–1536. 2012.
13. Rehman A, Zhou R. Reduced-reference image quality assessment by structural similarity estimation. IEEE Trans Imag Proc. 21:3378–3389. 2012.
14. Sampat MP, Wang Z, Gupta S. Complex wavelet structural similarity: a new image similarity index. IEEE Trans Imag Proc. 18:2385–2401. 2009.
15. Wang S, Rehman A, Wang Z. Perceptual video coding based on SSIM-inspired divisive normalization. IEEE Trans Imag Proc. 22:1418–1429. 2013.
16. Zujovic J, Pappas TN, Neuhoff DL. Structural texture similarity metrics for image analysis and retrieval. IEEE Trans Imag Proc. 22:2545–2558. 2013.
17. Siddon RL. Fast calculation of the exact radiological path for a three-dimensional CT array. Med Phys. 12:252–255. 1985.
18. De Man B, Basu S. Distance-driven projection and backprojection in three dimensions. Physics in medicine and biology. 49:2463–2475. 2004.