Journal List > J Korean Soc Radiol > v.69(1) > 1087300

Kim, Park, and Park: Evaluation of the Incidence on Insufficient Cytology Results Comparing Different Ultrasound-Guided Aspiration Techniques for Thyroid Nodules

Abstract

Purpose

We compared the incidence of insufficient thyroid cytology due to blood-stained materials or low cellularity in terms of aspiration technique, especially focusing on the degree of suction pressure and needle size.

Materials and Methods

Three experienced radiologists performed ultrasound-guided aspiration for thyroid nodules in 1174 thyroid nodules consecutively. Three different techniques were used; (A) using a 25 gauge needle with mainly capillary technique in 269 nodules; (B) using a 25 gauge needle with 3 cc syringe and minimal suction pressure in 303 nodules; (C) using a 22-23 gauge needle with 10 cc syringe and aspirator in 602 nodules. The differences of the incidence of the insufficient cytology among the three aspiration techniques and relationships of the incidence and needle size/degree of suction pressure was statistically analyzed using the Mann-Whitney U test and the chi-square test with linear-by-linear association.

Results

Overall, the difference in insufficient cytology was significant across the three aspiration technique (p = 0.004), and the incidence tended to increase significantly with increase of needle size and degree of suction pressure (p < 0.001). A pairwise comparison of aspiration techniques found significant differences (p = 0.003) between techniques (A) and (C), and no differences between technique (B) and (C) (p = 0.07) and between techniques (A) and (B) (p = 0.10).

Conclusion

The incidence of insufficient cytology was significantly low in the capillary technique, and it increased significantly with the increase of needle size and degree of suction pressure.

INTRODUCTION

Fine needle aspiration (FNA) for thyroid nodule is a standard diagnostic procedure. One major limitation of FNA is a non-diagnostic cytology result due to inadequate cytology specimen. Although FNA generally yields sufficient cytology results, there have been questions with regard to aspiration pressure and needle size. Previous studies evaluated the differences of sufficient sample rates between thick and thin needles and between the FNA with active suctions (FNAS) and FNA capillary techniques (FNAC) and the result of the comparative studies were inconclusive (1-8). In this study, we compared the incidence of insufficient cytology results according to the aspiration techniques, especially focusing on the degree of suction pressure and needle size.

MATERIALS AND METHODS

From May 2009 to December 2010, three experienced radiologists who are familiar to the ultrasound-guided aspiration, performed FNA studies consecutively in 1174 thyroid nodules from 987 patients (322 men, 665 women; mean age 52.7 years) during different time periods. The operators performed FNA studies over 5 to 17 months consecutively with or without overlapping time periods. The three radiologists used different aspiration techniques [we arbitrarily described as the technique (A), (B), and (C)], and they did not acknowledge that their FNA studies were conducted in different ways from one another. For technique (A), 25 gauge needles were used mainly with capillary technique, and the radiologist had 2 years of experience in FNA. For technique (B), 25 gauge needles with 3 cc syringe were used with intermittent minimal suction pressure, and the radiologist had 8 years of experience in FNA. For technique (C), 22-23 gauge needles with 10 cc syringe and aspirator were used for active aspiration, and the radiologist had 5 years of experience in FNA. The aspiration volume in technique (C) was usually to fill the needle hub. The aspiration volume in technique (A) and (B) was usually one third of the needle hub. Aspiration was usually conducted once or twice per nodule.
During the study period, the cytology was not reported according to the Bethesda system criteria. We retrospectively categorized cytology results as four grades: grade 1 for blood only or mostly blood cells with scant cellularity, grade 2 for scanty follicular cells with hemorrhagic background, grade 3 for insufficient results due to scanty cellularity without mention of hemorrhagic background, and grade 4 for sufficient cytology specimen. We arbitrarily assumed invasiveness of three aspiration techniques according to the needle size and degree of suction pressure, and we assigned ordinal scales as followed; technique (A) as 1, technique (B) as 2, and technique (C) as 3.
We evaluated the incidence of malignancy and analyzed whether the incidence of malignant lesions was different among the three groups by using the Kruskal-Wallis test. The difference in incidence of insufficient cytology results and the relationships between the incidence and invasiveness of the aspiration technique among three technique groups was statistically analyzed using Pearson's chi-square test with linear-by-linear association. The pairwise incidence differences between each pair of groups was statistically analyzed using the Mann-Whitney U test and the relationships between the incidence of insufficient cytology results and invasiveness of aspiration technique among groups was analyzed by the Pearson's chi-square test with linear-by-linear association. Statistical analysis was performed using SPSS for Windows (SPSS Inc., an IBM Company, Chicago, IL, USA), and p-values of less than 0.05 were considered to represent statistical significance.

RESULTS

Malignant lesions were present in 15% (178/1174) of all nodules [14.9% (40/269) for group of technique (A), 15.5% (47/303) for group of technique (B), 15.1% (91/602) for group of technique (C)], and there was no significant differences in the incidence of malignant lesions between three groups. The insufficient cytology results occurred in 18.6% for the technique (A), 24.4% for the technique (B), and 29.2% for the technique (C), and detailed results are summarized in Table 1. Overall, the difference in incidence of the insufficient cytology results was significant among the three aspiration techniques (p = 0.004), and the incidence of insufficient cytology results tended to increase significantly with the increase of needle size and degree of suction pressure (linear-by-linear association, p < 0.001). By comparing the two aspiration techniques, the difference was significant (p = 0.003) between technique (A) and (C), and not significant between technique (B) and (C) (p = 0.07) or between technique (A) and (B) (p = 0.10). The proportional tendency between the incidence of insufficient results and needle size/degree of suction pressure was statistically significant between technique (A) and (C) (linear-by-linear association, p < 0.001), technique (B) and (C) (p = 0.02).

DISCUSSION

In our study, FNAC with a smaller fine needle yielded better results in terms of sufficient cytology specimen. Cytology adequacy is important for accurate diagnosis of thyroid nodule. There have been controversial results about the needle sizes and aspiration techniques for adequate cytology specimen in thyroid nodules, and the previous results were summarized in Table 2. Previous comparative studies have shown no significant differences between FNAC and FNAS (1, 2). However, there have been one-sided results favoring FNAC (3, 4) or FNAS (7). Similarly in the aspiration technique, there have been no prominent differences in results on needle sizes (5, 6, 9), or one-sided results favoring smaller needles (3, 7) or larger needles (8). In summary, although sufficient volume of aspiration may be obtained by using larger needles and active suction, it may not guarantee adequacy of cytology specimen and may be more easily obscured by red blood cells (5, 6).
In our study, a mixed combination of the aspiration techniques and needle sizes could be compared fortuitously, and FNAC resulted in better cytology adequacy. The volume of aspiration in FNAC was relatively smaller than the volume of FNAS within our study. Although it may seem peculiar that the smaller volume of aspiration could result in better cytology adequacy, we interpret our results in terms of needle sizes and degrees of suction. Generally, we can see several vessel structures in thyroid nodules on a color Doppler study. In our opinion, although the difference of needle size was about 0.2 mm in our study, large sized needles may be more likely to puncture or penetrate the vessel structure. One of the criteria of needle withdrawal during FNA is the volume of aspiration. If we combined large needle sizes with active suction, we may have a large volume of aspiration rapidly, but the chance of blood-stained materials occupying the volume may be increased and the incidence of insufficient cytology may increase. From the patient's perspective, a thinner needle with capillary technique may cause the least discomfort such as pain and bleeding within the thyroid gland. In addition, although the chances are extremely low, the possibility of needle tract seeding during FNA may be smaller in finer needles and FNAC (10).
We have encountered some limitations in this study. First, we did not consider nodule characteristics such as vascularity, echogenicity, and size of the nodules. The imaging characteristics such as echogenicity, vascularity, and size may affect the adequacy of cytology specimen. Heterogeneous echoic nodule, cystic portions > 50%, and sizes less than 5 mm or larger than 10 mm were all related to the inadequate cytology results (9, 11). In our study, the operator performed FNA studies consecutively and independently, and the incidences of malignancy among three groups were not statistically different. Therefore, we think that the imaging characteristics of the nodules may not be significantly different between the three groups. Second, the cytology results might not be consistent because specimens were read by several pathologists during the study, and cytology reports were not made by the standardized form such as the Bethesda system.
In conclusion, the incidence of insufficient cytology result was significantly different according to aspiration technique, and it was least in the capillary technique. The incidence of insufficient cytology result tended to increase significantly with increase of needle size and degree of suction pressure.

Figures and Tables

Table 1
Results of Cytology Specimen According to the Aspiration Technique
jksr-69-23-i001

Note.-Grade 1 for blood only or mostly blood cells with scant cellularity, Grade 2 for scanty follicular cells with hemorrhagic background, Grade 3 for insufficient results due to scanty cellularity without mention of hemorrhagic background, Grade 4 for sufficient cytology specimen.

FNAC = fine needle aspiration capillary technique, FNAS = fine needle aspiration with active suction

Table 2
Summary of the Comparative Studies between FNAS and FNAC
jksr-69-23-i002

Note.-*Haddadi-Nezhad (2003) compared the qualitative score of cytology specimen.

FNAC = fine needle aspiration with capillary technique, FNAS = fine needle aspiration with active suction

Notes

This study was supported by a grant from the Jeju National University Hospital Research Fund (2011).

References

1. Tublin ME, Martin JA, Rollin LJ, Pealer K, Kurs-Lasky M, Ohori NP. Ultrasound-guided fine-needle aspiration versus fine-needle capillary sampling biopsy of thyroid nodules: does technique matter? J Ultrasound Med. 2007; 26:1697–1701.
2. Haddadi-Nezhad S, Larijani B, Tavangar SM, Nouraei SM. Comparison of fine-needle-nonaspiration with fine-needle-aspiration technique in the cytologic studies of thyroid nodules. Endocr Pathol. 2003; 14:369–373.
3. Degirmenci B, Haktanir A, Albayrak R, Acar M, Sahin DA, Sahin O, et al. Sonographically guided fine-needle biopsy of thyroid nodules: the effects of nodule characteristics, sampling technique, and needle size on the adequacy of cytological material. Clin Radiol. 2007; 62:798–803.
4. Romitelli F, Di Stasio E, Santoro C, Iozzino M, Orsini A, Cesareo R. A comparative study of fine needle aspiration and fine needle non-aspiration biopsy on suspected thyroid nodules. Endocr Pathol. 2009; 20:108–113.
5. Gümüş M, Cay N, Algin O, Ipek A, Ersoy RÜ, Belenli O, et al. Comparison of 21 and 27 gauge needles for determining sample adequacy in the aspiration biopsy of thyroid nodules. Diagn Interv Radiol. 2012; 18:102–105.
6. Tangpricha V, Chen BJ, Swan NC, Sweeney AT, de las Morenas A, Safer JD. Twenty-one-gauge needles provide more cellular samples than twenty-five-gauge needles in fine-needle aspiration biopsy of the thyroid but may not provide increased diagnostic accuracy. Thyroid. 2001; 11:973–976.
7. de Meer SG, Schreinemakers JM, Zelissen PM, Stapper G, Sie-Go DM, Rinkes IH, et al. Fine-needle aspiration of thyroid tumors: identifying factors associated with adequacy rate in a large academic center in the Netherlands. Diagn Cytopathol. 2012; 40:Suppl 1. E21–E26.
8. Hanbidge AE, Arenson AM, Shaw PA, Szalai JP, Hamilton PA, Leonhardt C. Needle size and sample adequacy in ultrasound-guided biopsy of thyroid nodules. Can Assoc Radiol J. 1995; 46:199–201.
9. İnci MF, Özkan F, Yüksel M, Şalk İ, Şahin M. The effects of sonographic and demographic features and needle size on obtaining adequate cytological material in sonography-guided fine-needle aspiration biopsy of thyroid nodules. Endocrine. 2013; 43:424–429.
10. Polyzos SA, Anastasilakis AD. A systematic review of cases reporting needle tract seeding following thyroid fine needle biopsy. World J Surg. 2010; 34:844–851.
11. Choi YS, Hong SW, Kwak JY, Moon HJ, Kim EK. Clinical and ultrasonographic findings affecting nondiagnostic results upon the second fine needle aspiration for thyroid nodules. Ann Surg Oncol. 2012; 19:2304–2309.
TOOLS
Similar articles