Journal List > Hip Pelvis > v.25(4) > 1081997

Kim, Kweon, Han, and Hwang: The Antero-medial Cortex Overlapped Reduction of Unstable Intertrochanteric Fractures

Abstract

Purpose

The purpose of this article is to evaluate the result of treatment of unstable intertrochanteric fractures by lateralization of distal fragment and antero-medial cortex contact of the distal shaft piece.

Materials and Methods

We conducted an analysis of 20 cases of unstable intertrochanteric fractures treated using a gamma-3 nail from August 2011 to August 2012 and followed up for more than one year. Using postoperative and last follow-up radiographs, we measured NSA, TAD, Cleveland index, sliding length of the lag screw, and union time. Adequacy of reduction was assessed by a modification in the criteria of Baumgaertner and classified as good, acceptable, or poor.

Results

The mean NSA was 140° postoperative and 135° at last follow-up. The mean TAD was 11.3 mm. The position of the lag screw was in center-center in 12 cases, center-inferior in eight cases. The mean distance of lag screw sliding was 5.5 mm at last follow-up. The mean union time was 3.7 months. The state of reduction postoperatively was good in 15 cases, and acceptable in five cases. There was no failure of reduction, lag screw cut-out, or other complications at last follow-up.

Conclusion

The reduction method for lateralization of distal fragment and antero-medial cortex contact of the distal shaft piece in an unstable intertrochanteric fracture is very useful for prevention of collapse of the fracture site, lag screw cut-out, and mechanical failure.

Figures and Tables

Fig. 1
Jensen classification. Type 3- loss of posterolateral support, Type 4- loss of medial support, Type 5- four part.
hp-25-280-g001
Fig. 2
(A) Pre-operative radiograph shows lateral displacement of proximal fragment. (B) Radiographs show medialization of proximal fragment using by Steinmann pin and antero-medial cortex overlapping. (C) Radiograph shows that Steinman pin is keeping to maintain the reduction during nail insertion.
hp-25-280-g002
Fig. 3
(A) Preoperative radiographs show 4-part intertrochanteric fracture. (B) Postoperative radiographs show valgus reduction in AP view and anterior angulation in lateral view. (C) Follow-up radiographs after 3 months show bone union.
hp-25-280-g003
Table 1
Classification of Reduction
hp-25-280-i001
Table 2
Mobility Score of Paker and Palmer
hp-25-280-i002
Table 3
Radiographic Results
hp-25-280-i003

References

1. Cho MR, Lee SH, Cho DW, Ko SB. Treatment of unstable intertrochanteric fractures of the femur using an anti-hypersliding compression hip screw and TSP. J Korean Hip Soc. 2012; 24:37–44.
crossref
2. Kim BS, Cho DY, Yoon HK, et al. Common modes of fixation failure with a sliding hip screw encountered unstable intertrochanteric fracture. J Korean Soc Fract. 2003; 16:15–21.
crossref
3. Laros GS, Moore JF. Complication of fixation in intertrochanteric fractures. Clin Orthop Relat Res. 1974; (101):110–119.
4. Lee KJ. Fixation failure of proximal femoral nail antirotation in femoral intertrochanteric fracture. Hip Pelvis. 2012; 24:302–308.
crossref
5. Carr JB. The anterior and medial reduction of intertrochanteric fractures: a simple method to obtain a stable reduction. J Orthop Trauma. 2007; 21:485–489.
crossref
6. Larsson S, Friberg S, Hansson LI. Trochanteric fractures. Influence of reduction and implant position on impaction and complications. Clin Orthop Relat Res. 1990; (259):130–139.
7. Jensen JS. Classification of trochanteric fractures. Acta Orthop Scand. 1980; 51:803–810.
crossref
8. Doppelt SH. The slidning compression screw--today's best answer for stabilization of intertrochanteric hip fractures. Orthop Clin North Am. 1980; 11:507–523.
crossref
9. Cleveland M, Bosworth DM, Thompson FR, Wilson HJ Jr, Ishizuka T. A ten-year analysis of intertrochanteric fractures of the femur. J Bone Joint Surg Am. 1959; 41-A:1399–1408.
crossref
10. Fogagnolo F, Kfuri M Jr, Paccola CA. Intramedullary fixation of pertrochanteric hip fracture with the short AO-ASIF proximal femoral nail. Arch Orthop Trauma Surg. 2004; 124:31–37.
crossref
11. Parker MJ, Palmer CR. A new mobility score for predicting mortality after hip fracture. J Bone Joint Surg Br. 1993; 75:797–798.
crossref
12. Parker MJ. Trochanteric hip fractures. Fixation failure commoner with femoral medialization, a comparison of 101 cases. Acta Orthop Scand. 1996; 67:329–332.
crossref
13. Pajarinen J, Lindahl J, Savolainen V, Michelsson O, Hirvensalo E. Femoral shaft medialisation and neck-shaft angle in unstable pertrochanteric femoral fractures. Int Orthop. 2004; 28:347–353.
crossref
14. Kokoroghiannis C, Aktselis I, Deligeorgis A, Fragkomichalos E, Papadimas D, Pappadas I. Evolving concepts of stability and intramedullary fixation of intertrochanteric fractures--a review. Injury. 2012; 43:686–693.
crossref
15. Baumgaertner MR, Curtin SL, Lindskog DM, Keggi JM. The value of the tip-apex distance in predicting failure of fixation of peritrochanteric fractures of the hip. J Bone Joint Surg Am. 1995; 77:1058–1064.
crossref
16. De Bruijn K, den Hartog D, Tuinebreijer W, Roukema G. Reliability of predictors for screw cutout in intertrochanteric hip fractures. J Bone Joint Surg Am. 2012; 94:1266–1272.
crossref
17. Davis TR, Sher JL, Checketts RG, Porter BB. Intertrochanteric fractures of the femur: a prospective study comparing the use of the Küntscher-Y nail and sliding hip screw. Injury. 1988; 19:421–426.
crossref
18. Kyle RF, Gustilo RB, Premer RF. Analysis of six hundred and twenty-two intertrochanteric hip fractures. J Bone Joint Surg Am. 1979; 61:216–221.
crossref
19. Mulholland RC, Gunn DR. Sliding screw plate fixation of intertrochanteric femoral fractures. J Trauma. 1972; 12:581–591.
crossref
20. Tsukada S, Okumura G, Matsueda M. Postoperative stability on lateral radiographs in the surgical treatment of pertrochanteric hip fractures. Arch Orthop Trauma Surg. 2012; 132:839–846.
crossref
21. Kuzyk PR, Zdero R, Shah S, Olsen M, Waddell JP, Schemitsch EH. Femoral head lag screw position for cephalomedullary nails: a biomechanical analysis. J Orthop Trauma. 2012; 26:414–421.
22. Hsueh KK, Fang CK, Chen CM, Su YP, Wu HF, Chiu FY. Risk factors in cutout of sliding hip screw in intertrochanteric fractures: an evaluation of 937 patients. Int Orthop. 2010; 34:1273–1276.
crossref
23. Pervez H, Parker MJ, Vowler S. Prediction of fixation failure after sliding hip screw fixation. Injury. 2004; 35:994–998.
crossref
24. Apel DM, Patwardhan A, Pinzur MS, Dobozi WR. Axial loading studies of unstable intertrochanteric fractures of the femur. Clin Orthop Relat Res. 1989; (246):156–164.
crossref
25. Sarmiento A. Unstable intertrochteric fractures of the femur. Clin Orthop Relat Res. 1973; (92):77–85.
26. Andruszkow H, Frink M, Frömke C, et al. Tip apex distance, hip screw placement, and neck shaft angle as potential risk factors for cut-out failure of hip screws after surgical treatment of intertrochanteric fractures. Int Orthop. 2012; 36:2347–2354.
crossref
TOOLS