Abstract
Purpose
The purpose of this study is to report on the clinical results of more than 10 years of follow-up after ceramic articulation total hip arthroplasty in patients younger than 50 years old who had reported a result of short-term follow-up.
Materials and Methods
We studied 25 patients who underwent cementless THA using ceramic on ceramic articulation between Jan 1998 and Dec 2001. They were followed up for 2-4 years, with good results, and could be followed up for more than 10 years. The evaluation of clinical results included Harris hip score (HHS) and occurrence of thigh pain. Radiologic evaluation was based on osteolysis and the stability of components.
Results
The mean HHS improved from 57.7 to 93.3 during the period of 2-4 years of follow-up and 91.0 at more than 10 years of follow-up. Two patients experienced thigh pain during the period of 2-4 years of follow-up and none of the patients had thigh pain at more than 10 years of follow-up. On the last radiographs, stable fixation was observed in all cases, except for one case of ceramic fracture.
References
1. Christel PS. Biocompatibility of surgical-grade dense polycrystalline alumina. Clin Orthop Relat Res. 1992; (282):10–18.
2. Sedel L. Evolution of alumina-on-alumina implants: a review. Clin Orthop Relat Res. 2000; (379):48–54.
3. Hallab N, Merritt K, Jacobs JJ. Metal sensitivity in patients with orthopaedic implants. J Bone Joint Surg Am. 2001; 83-A:428–436.
4. Willert HG, Buchhorn GH, Fayyazi A, et al. Metal-on-metal bearings and hypersensitivity in patients with artificial hip joints. A clinical and histomorphological study. J Bone Joint Surg Am. 2005; 87:28–36.
5. Cipriano CA, Issack PS, Beksac B, Della Valle AG, Sculco TP, Salvati EA. Metallosis after metal-on-polyethylene total hip arthroplasty. Am J Orthop (Belle Mead NJ). 2008; 37:E18–E25.
6. Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. J Arthroplasty. 2001; 16:149–160.
7. Murphy SB, Ecker TM, Tannast M. Two- to 9-year clinical results of alumina ceramic-on-ceramic THA. Clin Orthop Relat Res. 2006; 453:97–102.
8. Older J. Charnley low-friction arthroplasty: a worldwide retrospective review at 15 to 20 years. J Arthroplasty. 2002; 17:675–680.
9. Synder M, Drobniewski M, Kozlowski P, Grzegorzewski A. Ceramic-ceramic articulation in uncemented total hip arthroplasty. Wiad Lek. 2005; 58:193–197.
10. Traina F, De Fine M, Di Martino A, Faldini C. Fracture of ceramic bearing surfaces following total hip replacement: a systematic review. Biomed Res Int. 2013; 2013:157247.
11. Reátegui D, García S, Bori G, Gallart X. Fracture of ceramic liner and head in a total hip arthroplasty with a sandwich type cup. Case Rep Orthop. 2013; 2013:291691.
12. Rosneck J, Klika A, Barsoum W. A rare complication of ceramic-on-ceramic bearings in total hip arthroplasty. J Arthroplasty. 2008; 23:311–313.
13. Ha YC, Kim SY, Kim HJ, Yoo JJ, Koo KH. Ceramic liner fracture after cementless alumina-on-alumina total hip arthroplasty. Clin Orthop Relat Res. 2007; 458:106–110.
14. Hannouche D, Nich C, Bizot P, Meunier A, Nizard R, Sedel L. Fractures of ceramic bearings: history and present status. Clin Orthop Relat Res. 2003; (417):19–26.
15. Choi JS, Seo SS, Ahn KC, et al. Clinical result of total hip arthroplasty with cementless ceramic to ceramic bearing short-term follow up. J Korean Hip Soc. 2005; 17:121–126.
16. Popescu D, Gallart X, Garcia S, Bori G, Tomas X, Riba J. Fracture of a ceramic liner in a total hip arthroplasty with a sandwich cup. Arch Orthop Trauma Surg. 2008; 128:783–785.
17. Nizard R, Sedel L, Hannouche D, Hamadouche M, Bizot P. Alumina pairing in total hip replacement. J Bone Joint Surg Br. 2005; 87:755–758.
18. Richter HG, Willmann G, Weick K. Improving the reliability of the ceramic-on-ceramic wear couple in THR. In : Jacobs JJ, Craig TL, editors. Alternative bearing surface in total joint replacement. West Conshohocken, PA: ASTM;1998. p. 173–185.
19. Willmann G, Brodbeck A, Effenberger H, Mauch CH, Nagel J, Dalla Pria P. Investigation of 87 retrieved ceramic femoral heads. In : Puhl W, editor. Bioceramics in orthopaedics-new applications. Stuttgart, Germany: Ferdinand Enke Verlag;1998. p. 13–18.
20. Archibeck MJ, Jacobs JJ, Black J. Alternate bearing surfaces in total joint arthroplasty: biologic considerations. Clin Orthop Relat Res. 2000; (379):12–21.
21. Diwanji SR, Seon JK, Song EK, Yoon TR. Fracture of the ABC ceramic liner: a report of three cases. Clin Orthop Relat Res. 2007; 464:242–246.
22. Hasegawa M, Sudo A, Hirata H, Uchida A. Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup. J Arthroplasty. 2003; 18:658–661.
23. Barrack RL, Burak C, Skinner HB. Concerns about ceramics in THA. Clin Orthop Relat Res. 2004; (429):73–79.
24. Koo KH, Ha YC, Jung WH, Kim SR, Yoo JJ, Kim HJ. Isolated fracture of the ceramic head after third-generation alumina-on-alumina total hip arthroplasty. J Bone Joint Surg Am. 2008; 90:329–336.
25. Min BW, Song KS, Kang CH, Bae KC, Won YY, Lee KY. Delayed fracture of a ceramic insert with modern ceramic total hip replacement. J Arthroplasty. 2007; 22:136–139.
26. Park JS, Kim WJ, Soh JW, Jung HW, Suh YS. Early comminuted fracture of an alumina liner in a ceramic on ceramic total hip arthroplasty. J Korean Orthop Assoc. 2012; 47:392–396.
27. Petsatodis GE, Papadopoulos PP, Papavasiliou KA, Hatzokos IG, Agathangelidis FG, Christodoulou AG. Primary cementless total hip arthroplasty with an alumina ceramic-on-ceramic bearing: results after a minimum of twenty years of follow-up. J Bone Joint Surg Am. 2010; 92:639–644.
28. Yeung E, Bott PT, Chana R, et al. Mid-term results of third-generation alumina-on-alumina ceramic bearings in cementless total hip arthroplasty: a ten-year minimum follow-up. J Bone Joint Surg Am. 2012; 94:138–144.
29. Hamadouche M, Boutin P, Daussange J, Bolander ME, Sedel L. Alumina-on-alumina total hip arthroplasty: a minimum 18.5-year follow-up study. J Bone Joint Surg Am. 2002; 84-A:69–77.