Abstract
Between June 1996 and July 1997, 29 tibial fracture patients were treated using the Ilizarov method and apparatus. The mean follow-up petiod was 18 months. Among 29 cases, 11 were closed fractures with comminution and 18 were open fractures. There were 2 Gustilo-Anderson type I, 5 type II, and 11 type III open tibial fractures. Complications included 4 pin tract average time from application of the device to complete fracture healing was 26.3 weeks. According to Tucker's functional criteria, the results were 14 excellent, 9 good, 4 fair, 2 poor. No practical contraindications to the use of the Ilizarov device in the management of tibial fractures were encountered. We concluded that Ilizarov method is indeed a useful adjunct for the
treatment of either open or closed tibial fractures.