Abstract
Purpose
Glass particle contamination of the contents of single-dose glass ampules can occur upon opening. Different aspiration techniques, different sizes of needles, different sizes of ampules, and different cutting methods were studied to determine if they had any effect on glass particle contamination.
Method
Different aspiration techniques(with filter, without filter), different sizes of needles(18G, 25G), different sizes of ampules(2ml, 20ml), and different cutting methods(with cotton, without cotton) were evaluated.
Method
Twenty ampules were randomly assigned in each group. Three slides containing glass particles for each ampule were made and counted under a microscope by 3 study blind persons.
Result
The number of glass particle contamination is much less when using a filter rather than without a filter. The number of glass particle contamination is much less when using a 25G needle rather than on 18G needle. The number of glass particle contamination is much less when using 2ml ampules rather than 20ml ampules. The number of glass particle contamination is much less when using cotton rather than without cotton.