Abstract

PURPOSE

The present study was intended to evaluate the effect of soldering techniques with infrared ray and gas torch under different gap distances (0.3 mm and 0.5 mm) on the tensile strength and surface porosity formation in Ni-Cr base metal alloy.

MATERIALS AND METHODS

Thirty five dumbbell shaped Ni-Cr alloy specimens were prepared and assigned to 5 groups according to the soldering method and the gap distance. For the soldering methods, gas torch (G group) and infrared ray (IR group) were compared and each group was subdivided by corresponding gap distance (0.3 mm: G3 and IR3, 0.5 mm: G5, IR5). Specimens of the experimental groups were sectioned in the middle with a diamond disk and embedded in solder blocks according to the predetermined distance. As a control group, 7 specimens were prepared without sectioning or soldering. After the soldering procedure, a tensile strength test was performed using universal testing machine at a crosshead speed 1 mm/min. The proportions of porosity on the fractured surface were calculated on the images acquired through the scanning electronic microscope.

RESULTS

Every specimen of G3, G5, IR3 and IR5 was fractured on the solder joint area. However, there was no significant difference between the test groups (P > .05). There was a negative correlation between porosity formation and tensile strength in all the specimens in the test groups (P < .05).

CONCLUSION

There was no significant difference in ultimate tensile strength of joints and porosity formations between the gas-oxygen torch soldering and infrared ray soldering technique or between the gap distance of 0.3 mm and 0.5 mm.

INTRODUCTION

Recently, the use of Ni-Cr base metal alloys in fixed prosthesis tends to increase because of the continued inflation of gold price. Base metal alloy has various advantages such as higher yield and tensile strength and better resistance to creep, compared with noble alloys.1-3 However, base metal alloys also have several crucial disadvantages to be used. One of the critical disadvantages is the technique sensitivity in laboratory procedures, especially during casting and soldering. To assure the fit of metal frameworks on abutments, a trial insertion is generally performed in a clinic. If any inadequacy was detected, sectioning and soldering of metal frameworks are required.4
Soldering is a traditional method for joining components of fixed partial dentures using an intermediate metal.5 The longevity of a soldered prosthesis depends on the mechanical properties of its solder joints.6-9 El-Ebrashi et al.10 reported that the stress was concentrated at the solder joint area and found to be tensile in nature. Therefore, the solder joint should have sufficient strength to endure the functional forces directed on it.6,9 Some previous studies suggested that the strength of base metal alloy in the solder joints is less predictable than that of gold alloy.11-13
Other studies have investigated the factors affecting the strength of the solder joint. Gap distance is one of the important factors affecting the strength of soldered joints.6,8,14,15 It has been reported that the optimal gap distance ranges from 0.15 mm16 to 0.76 mm.15 One study found that increasing the gap distance would increase the strength of the soldered connectors.15 However, according to Stade et al.,15 the method of soldering was more important in connector strength than gap width. Various heat sources for soldering were introduced to improve the quality of the joints. Gas-oxygen torch is a traditional heat source, but there are some problems such as gas inclusions, voids and excessive oxide layer formation.1,11,16,17 As an alternative approach, infrared soldering is introduced. Although several studies investigated the strength and quality of solder joints, the effectiveness of infrared soldering has not been widely investigated.6 Several advantages of the infrared ray technique are reported such as lack of gas inclusions and limitation of heating area.6,17-19 In other studies, there were disagreements about its predictability compared with other techniques.18-21
The purpose of this study was to evaluate and compare the effects of different soldering techniques including infrared ray and gas torch under different gap distance conditions (0.3 mm and 0.5 mm) on the tensile strength and the surface porosity in Ni-Cr base metal alloy.

MATERIALS AND METHODS

Thirty five wax patterns 18 mm in length, 3 mm in diameter and two 6 mm spheres on both ends were prepared for tensile testing (Fig. 1). The wax patterns were invested in a phosphate bonded investment and casting was performed with Ni-Cr based dental alloy (Rexillium® V, Jeneric/Pentron, San diego, USA) using a centrifugal casting machine and a propane gas-oxygen torch according to the manufacturer's instructions. The composition, product name, manufacturer of the casting alloy and solder material used for this study are listed in Table 1.
After casting, the rings were bench cooled and then divested. The specimens were blasted with 50 µm aluminous oxide particle. Some nodules were carefully removed from the specimen surfaces using low speed rotary instruments. Additional polishing procedures were not performed. The specimens were randomly assigned to five groups by soldering methods and gap distance (Table 2). Control group was tested for tensile strength without prior sectioning and soldering procedure. The specimens of the other groups were sectioned at the center, perpendicular to their long-axis, using a separating disk. Cutting jigs were prepared to ensure accurate and perpendicular cut of the specimens. Both ends of specimens were invested with plaster in rectangular shape (1.5 × 1.5 × 1.5 cm) and the midpoint of the specimens was sectioned by the disk. Then spacers were placed between two halves to allow precise gap distance (0.3 mm, 0.5 mm) and the sectioned specimens were united with pattern resin for stabilization during the investing procedure (Fig. 2). After the resin polymerization, plaster was carefully removed. The assembled specimens were invested with soldering investment (Deguvest® L, Degudent GmbH, Rodenbacher, Germany).
For the gas-oxygen torch soldering, the investment blocks were preheated to 600℃ in a furnace and a flux (Unitek™, 3M, Monrovia, USA) was applied, then solder alloy (Vera Solder™, Aalbadent Inc., Cordelia, USA) was placed over the joint area. The propane-oxygen gas torch was used and kept moving to prevent excessive oxide formation until the solder material flowed into the gap. For the infrared ray soldering, the invested specimens were placed on the refractory platform of the infrared soldering machine (Quasar Plus, Zhermack S.p.A., Badia Polesine, Italy) (Fig. 3). Flux was applied and a piece of solder was placed to the joint area. Then the specimen was soldered according to the manufacturer's instructions.
Before testing, the solder joint area of each specimen was trimmed with carborundum stone rotary instrument to remove excess solder material. The diameter of each soldered joint was measured with a caliper. Tensile testing was performed using a universal testing machine (Instron® 5582, Instron Co., Ltd., Canton, USA). Each specimen was pulled until fracture occurred at a constant crosshead speed of 1.0 mm/min. The data for each sample was automatically calculated and recorded by the analyzing program (Bluehill® software, Instron Co., Ltd., Canton, USA).
After tensile testing, the fractured surface of the specimens were analyzed with SEM (Hitachi S-3000H Scanning electron microscope, Hitachi Inc., Tokyo, Japan) and evaluated for the presence of porosity or voids. The percentage of the porous area to entire joint surface was measured with the image software (Adobe Acrobat 8 Professional, Adobe Systems, San Jose, USA) (Fig. 4).
The statistical analysis was carried out to find whether any significant difference of tensile strength or porosity among the groups. The data were analyzed at a confidence level of 95% with Kruskal-Wallis test using the statistical analysis software (SPSS version 12.0, SPSS Inc., Chicago, USA). Pearson's correlation test was used to evaluate whether the presence of porosity may have influenced the tensile strength.

RESULTS

The mean and the standard deviation of tensile strength are presented in Table 3. The control group showed apparently higher tensile strength than test groups. In gas torch soldered groups, the specimens with 5.0 mm gap shows higher mean tensile strength. In contrast, infra red groups showed higher tensile strength in smaller gap distance group. However, there were no significant differences among the test groups which were designed under different conditions (P = 0.174). The mean and the standard deviation of joint porosity are presented in Table 4. G3 group shows the highest porosity presence on soldered joint and G5 group showed the smallest number of the percent. The value of the infrared soldering showed relatively smaller standard deviation than those of the gas torch soldering groups. However, comparing the joint porosity, there was also no significant difference among the groups (P = .230). According to Pearson's correlation test, correlation coefficient of tensile strength and porosity was -0.813 (P = 0.00) and showed negative correlation (Fig. 5).

DISCUSSION

In this study, tensile strength and porosity formation were measured and compared when the two different soldering techniques, which were gas torch soldering and infrared ray soldering, were applied. The influence of the gap distance on the results was also evaluated.
The results of present study revealed that there was no significant difference in ultimate tensile strength between the two soldering techniques. This result coincides with the report of Tehini et al.19 One investigation with noble alloy material showed no significant difference between the conventional torch and infrared heating techniques.20 However, Cheng et al.22 suggested that the ultimate tensile strength of Chromium-Cobalt alloy connectors with the infrared soldering was significantly higher than those with a gas-oxygen technique.
The correlation between gap distance and joint strength has been investigated in many studies. Significant effect of gap distance on the joint's strength was presented.6,8,15,23 Also, it has been shown that increase of gap distance did not compromise the strength and the most unsatisfactory results occurred when there was an insufficient gap distance.8,15,23 Ryge23 reported that a gap distance of less than 0.005 inch (0.123 mm) would cause greater porosity and the decreased strength of the soldered joints. In one similar study concerning infrared soldering, it has been observed that the 0.5 mm gap distance resulted in higher tensile strength than the 0.3 mm.6 The compromised flow of the solder and the adverse effect of the thermal expansion of the parent alloy in the narrow gaps was explained as the cause. Nevertheless, no significant difference was found in present study between two gap distances.
Porosities are caused by the flux, gas, foreign body inclusions or insufficient wetting of the parent metal by solder alloy. This is supported by the finding of other studies.12,17,24 The correlation between the porosity and the strength have been widely accepted.12,24-26 It is also clearly proved that there is a negative effect of porosity to the soldering material in the present study. Some investigators suggested that soldering method27 and gap distance15,23 could be attributing factors to the porosity. Another studies17 represented that infrared method was more advantageous than gas torch in porosity formation since less gas inclusions were found. Ryge23 reported gap distance influenced the proportions of the porosity. However, in the current study, there were no significant differences between soldering methods and gap distance on the porosity.
As fixed partial dentures are exposed to repetitive mechanical stresses during mastication, further studies should evaluate the long-term effectiveness of the soldering methods simulated under intraoral conditions. In addition, the effect of the gap should be closely examined to improve the quality of the prosthesis with joints to be soldered.

CONCLUSION

This comparative study investigated the tensile strength and porosity formation of the joint by two soldering techniques (gas-torch soldering, infrared ray soldering) and evaluated the effect of the gap distance on the results.
Within the limitations of this study, infrared ray soldering may be an alternative method for the conventional gas-oxygen torch soldering. The gap distance between the soldered parts may give no effect to the tensile strength and porosity of the soldered joint within the range of 0.3 mm to 0.5 mm.

Figures and Tables

Fig. 1
The specimen made with Ni-Cr alloy.
jap-2-117-g001
Fig. 2
A Soldering block and embedded specimen.
jap-2-117-g002
Fig. 3
Infrared ray soldering machine.
jap-2-117-g003
Fig. 4
SEM image of fracture surface of specimen (×30).
jap-2-117-g004
Fig. 5
Correlation between tensile strength and porosity.
jap-2-117-g005
Table 1
The alloy and flux used in this study
jap-2-117-i001
Table 2
Soldering methods and gap condition of groups
jap-2-117-i002
Table 3
The tensile strength at failure (Unit: MPa)
jap-2-117-i003

Control: No soldering procedure, G3: 0.3 mm gap distance + gas torch soldering, G5: 0.5 mm gap distance + gas torch soldering, IR3: 0.3 mm gap distance + infrared soldering, IR5: 0.5 mm gap distance + infrared soldering

Table 4
The proportion of joint porosity area (Unit: %)
jap-2-117-i004

References

1. Blustein R, DePaul BM, Barnhart RC Jr, Green KA. A reliable technique of post soldering of nonprecious ceramic units. J Prosthet Dent. 1976. 36:112–114.
2. Huget EF, Vlica JM, Wall RM. Characterization of two ceramic-base-metal alloys. J Prosthet Dent. 1978. 40:637–641.
3. Moffa JP, Lugassy AA, Guckes AD, Gettleman L. An evaluation of nonprecious alloys for use with porcelain veneers. Part I. Physical properties. J Prosthet Dent. 1973. 30:424–431.
4. Nikellis I, Levi A, Zinelis S. Effect of soldering on the metal-ceramic bond strength of an Ni-Cr base alloy. J Prosthet Dent. 2005. 94:435–439.
5. Shillingburg HT, Hobo S, Whitsett LD, Jacobi R, Brackett SE. Fundamentals of Fixed Prosthodontics. 1997. 3rd ed. Chicago: Quintessence Publishing;509.
6. Anwar EM, Naggar GA. Effect of different gap distances on the tensile strength and microstructure of infra-red soldered joints. Cairo Dent J. 2004. 20:149–155.
7. Marshall AG, Goodkind RJ. An investigation of the tensile strength of nickel-chromium alloy dental solder joints. J Prosthet Dent. 1984. 52:666–672.
8. Rasmussen EJ, Goodkind RJ, Gerberich WW. An investigation of tensile strength of dental solder joints. J Prosthet Dent. 1979. 41:418–423.
9. Watanabe I, Watanabe E, Atsuta M, Okabe T. Tensile strength of soldered gold alloy joints. J Prosthet Dent. 1997. 78:260–266.
10. el-Ebrashi MK, Craig RG, Peyton FA. Experimental stress analysis of dental restorations. VII. Structural design and stress analysis of fixed partial dentures. J Prosthet Dent. 1970. 23:177–186.
11. Kaylakie WG, Brukl CE. Comparative tensile strengths of nonnoble dental alloy solders. J Prosthet Dent. 1985. 53:455–462.
12. Anusavice KJ, Okabe T, Galloway SE, Hoyt DJ, Morse PK. Flexure test evaluation of presoldered base metal alloys. J Prosthet Dent. 1985. 54:507–517.
13. Townsend LW, Vermilyea SG, Griswold WH. Soldering nonnoble alloys. J Prosthet Dent. 1983. 50:51–53.
14. Stackhouse JA Jr. Assembly of dental units by soldering. J Prosthet Dent. 1967. 18:131–139.
15. Stade EH, Reisbick MH, Preston JD. Preceramic and postceramic solder joints. J Prosthet Dent. 1975. 34:527–532.
16. Willis LM, Nicholls JI. Distortion in dental soldering as affected by gap distance. J Prosthet Dent. 1980. 43:272–278.
17. Ryge G, Kozak SF, Fairhurst CW. Porosities in dental gold castings. J Am Dent Assoc. 1957. 54:746–754.
18. Carlberg T, Wictorin L. Soldering of dental alloys under vacuum by IR-heating. Dent Mater. 1986. 2:279–283.
19. Tehini GE, Stein RS. Comparative analysis of two techniques for soldered connectors. J Prosthet Dent. 1993. 69:16–19.
20. Cattaneo G, Wagnild G, Marshall G, Watanabe L. Comparison of tensile strength of solder joints by infrared and conventional torch technique. J Prosthet Dent. 1992. 68:33–37.
21. Chaves M, Vermilyea SG, Papazoglou E, Brantley WA. Effects of three soldering techniques on the strength of high-palladium alloy solder joints. J Prosthet Dent. 1998. 79:677–684.
22. Cheng AC, Chai JY, Gilbert J, Jameson LM. Mechanical properties of metal connectors soldered by gas torch versus an infrared technique. J Prosthodont. 1993. 2:103–109.
23. Ryge G. Dental soldering procedures. Dent Clin North Am. 1958. 2:747–757.
24. Anusavice KJ, Shafagh I. Inert gas presoldering of nickel-chromium alloys. J Prosthet Dent. 1986. 55:317–323.
25. Nicholls JI, Lemm RW. Tensile strength of presoldered and postsoldered joints. J Prosthet Dent. 1985. 53:476–482.
26. Sobieralski JA, Brukl CE, Smith NK. Tensile strengths and microscopic analysis of nickel-chromium base metal postceramic solder joints. J Prosthet Dent. 1987. 58:35–42.
27. Cheng AC, Chai JY, Gilbert J, Jameson LM. Investigation of stiffness and microstructure of joints soldered with gas-oxygen torch and infrared methods. J Prosthet Dent. 1994. 72:8–15.