Abstract
Purpose
This study evaluated the clinical and radiologic results of total hip arthroplasty and bipolar hemiarthroplasty using collarless polished tapered femoral stem.
Materials and Methods
We retrospectively reviewed the results of 33 patients who underwent THA and BHA using cemented CPT femoral stem from November 2006 to April 2009. The mean follow-up period was 33 months. The clinical results were evaluated with a Harris Hip Score (HSS), and radiographic results were assessed with cement grade, osteolysis, loosening, stress shielding and subsidence methods.
Results
Mean HSS improved with 91 points. Postoperative cement grade was A in 14 cases, B in 14 cases, C1 in 5 cases and D in none. Aseptic loosening was not found, while focal radiolucency in zone 8 was found. 70% of stems showed grade 1 and 2 stress shielding according to Engh's criteria. Subsidence of the femoral stem was less than 1 mm in 32 cases, and was 1.47 mm in another case. Ectopic ossification was observed in 13 cases, class I in 11 cases, and class II in 2 cases, using Brooker's classification.
Figures and Tables
References
1. Bickel WH, Jackson AE. Intertrochanteric fractures of the femur; an analysis of the end results of 126 fractures treated by various methods. Surg Gynecol Obstet. 1950. 91:14–24.
2. Cobelli NJ, Sadler AH. Ender rod versus compression screw fixation of hip fractures. Clin Orthop Relat Res. 1985. 201:123–129.
3. Kang CN, Kim JO, Kim DW, Koh YD, Ko SH, Lee KW. Comparison of hemiarthroplasty and compression hip screw on elderly unstable intertrochanteric fractures. J Korean Soc Fract. 1997. 10:738–745.
5. Harris WH, McGarthy JC Jr, O'Neill DA. Femoral component looseing using contemporary techniques of femoral cement fixation. J Bone Joint Surg Am. 1982. 64:1063–1067.
6. Gie GA, Ling RS, Timperley AJ. Stem fracture with the Exeter prosthesis. Acta Orthop Scand. 1996. 67:206–207.
7. Yates PJ, Burston BJ, Whitley E, Bannister GC. Collarless polished tapered stem: clinical and radiological results at a minimum of ten years' follow-up. J Bone Joint Surg Br. 2008. 90:16–22.
8. Gruen TA, McNeice GM, Amstrutz HC. "Modes of failure" of cemented stem-type femoral components: a radiographic ananlysis of looening. Clin Orthop Relat Res. 1979. 141:17–27.
9. Harris WH, McGann WA. Loosening of the femoral component after use of the medullary-plug cementing technique. Follow-up note with a minimum five-year follow-up. J Bone Joint Surg Am. 1986. 68:1064–1066.
10. Fowler JL, Gie GA, Lee AJ, Ling RS. Experience with the Exeter total hip replacement since 1970. Orthop Clin North Am. 1988. 19:477–489.
11. Engh CA, Bobyn JD. The influence of stem size and extent of porous coating on femoral bone resorption after primary cementless hip arthroplasty. Clin Orthop Relat Res. 1988. 231:7–28.
12. Barrack RL, Mulroy RD Jr, Harris WH. Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12-year radiographic review. J Bone Joint Surg Br. 1992. 74:385–389.
13. Brooker AF, Bowerman JW, Robinson RA, Riley LH Jr. Ectopic ossification following total hip replacement. Incidence and a method of classification. J Bone Joint Surg Am. 1973. 55:1629–1632.
14. Stauffer RN. Ten-year follow-up study of total hip replacement. J Bone Joint Surg Am. 1982. 64:983–990.
15. Fowler JL, Gie GA, Lee AJ, Ling RS. Experience with the Exeter total hip replacement since 1970. Orthop Clin North Am. 1988. 19:477–489.
16. Herberts P, Malchau H. How outcome studies have changed total hip arthroplasty practices in Sweden. Clin Orthop Relat Res. 1997. 344:44–60.
17. Duparc J, Massin P. Results of 203 total hip replacements using a smooth cementless femoral component. J Bone Joint Surg Br. 1992. 74:251–256.
18. Lombardi AV Jr, Mallory TH, Vaughan BK, Drouillard P. Aseptic loosening in total arthroplasty secondary to osteolysis induced by wear debris from titanium-alloy modular femoral heads. J Bone Joint Surg Am. 1989. 71:1337–1342.
19. Mohler CG, Callaghan JJ, Collis DK, Johnston RC. Early loosening of the femoral component at the cement-prosthesis interface after total hip replacement. J Bone Joint Surg Am. 1995. 77:1315–1322.
20. Woolson ST, Maloney WJ. Cementless total hip arthroplasty using a porous-coated prosthesis for bone ingrowth fixation. 3 1/2-year follow-up. J Arthroplasty. 1992. 7:Suppl. 381–388.
21. Rockborn P, Olsson SS. Loosening and bone resorption in exeter hip arthroplasties. Review at a minimum of five years. J Bone Joint Surg Br. 1993. 75:865–868.
22. Testa NN, Mazur KU. Heterotopic ossification after direct lateral approach and transtrochanteric approach to the hip. Orthop Rev. 1988. 17:965–971.