Journal List > J Korean Fract Soc > v.23(1) > 1037790

Lee, Park, Kim, Park, Cho, Kim, and Rhee: Modified Spring Plate for Treatment of Unstable Distal Clavicle Fractures

Abstract

Purpose

Unstable distal clavicle fractures should be treated surgically but may be difficult in firm fixation because of small distal fragment. Although a variety of fixation methods have been currently used, none of the methods seem to be firm fixation and little pain. We present a new technique using a spring plate which was modified from one third tubular plate and report the early results.

Materials and Methods

Modified spring plate was made from one third tubular plate and the distal hole of the plate was cutting and sharpened by rasp. The sharp edge was bent just like an animal claw (C shape). Between May 2007 and June 2009, a total of six patients with distal clavicle fracture were treated using modified spring plate. A sling was applied in the immediate post operative period for six weeks and exercises were started immediately.

Results

Union was achieved in all cases with excellent results without complication (mean Constant score, 96). All patients had returned to ordinary daily activities but mild limitation of abduction (150°) by seven weeks after surgery. After six months, the plate was removed.

Conclusion

The modified spring plate has provided stable fixation for unstable distal clavicle fixation without disturbance to the acromioclavicular joint, subacromial space, or rotator cuff.

Figures and Tables

Fig. 1
Close up photograph of modified spring plate. A newly designed spring plate which is made from ordinary one third tubular plate; The distal hole of the plate was cutting and sharpened by rasp. The sharp edge was bent just like an animal claw (C shape).
jkfs-23-64-g001
Fig. 2
(A) Distal clavicle comminuted fracture in a 47-year-old man.
(B) After modified spring plate fixation. Note the acromioclavicular joint subluxation caused by acromioclavicular ligament damage.
(C) After removal of modified spring plate.
jkfs-23-64-g002
Fig. 3
(A) Distal clavicle fracture in a 46-year-old man.
(B) After modified spring plate fixation.
jkfs-23-64-g003
Table 1
Summary of cases
jkfs-23-64-i001

*Fracture type by Neer classification (1963), MVA: Motor vehicle accident.

References

1. Allman FL Jr. Fractures and ligamentous injuries of the clavicle and its articulation. J Bone Joint Surg Am. 1967. 49:774–778.
crossref
2. Constant CR, Murley AH. A clinical method of functional assessment of the shoulder. Clin Orthop Relat Res. 1987. 214:160–164.
crossref
3. Eiff MP, Hatch RL, Calmbach WL. Clavicle and scapula fractures. Fracture management for primary care. 1998. Philadelphia: Saunders Co;131–142.
4. Eskola A, Vainionpää S, Myllynen P, Pätiälä H, Rokkanen P. Outcome of clavicular fracture in 89 patients. Arch Orthop Trauma Surg. 1986. 105:337–338.
crossref
5. Flinkkilä T, Ristiniemi J, Hyvönen P, Hämäläinen M. Surgical treatment of unstable fractures of the distal clavicle: a comparative study of kirschner wire and clavicular hook plate fixation. Acta Orthop Scand. 2002. 73:50–53.
crossref
6. Henkel T, Oetiker R, Hackenbruch W. Treatment of fresh Tossy III acromioclavicular joint dislocation by ligament suture and temporary fixation with the clavicular hooked plate. Swiss Surg. 1997. 3:160–166.
7. Kang HJ, Park KK, Yoon HK, Song HK, Hahn SB. T plate fixation for unstable fracture of distal clavicle. J Korean Fract Soc. 2006. 19:329–334.
crossref
8. Kona J, Bosse MJ, Staeheli JW, Rosseau RL. Type II distal clavicle fractures: a retrospective review of surgical treatment. J Orthop Trauma. 1990. 4:115–120.
9. Mast J, Jakob R, Ganz R. Planning and reduction technique in fracture surgery. 1989. New York: Springer-Verlag.
10. Meda PV, Machani B, Sinopidis C, Braithwaite I, Brownson P, Frostick SP. Clavicular hook plate for lateral end fractures:-a prospective study. Injury. 2006. 37:277–283.
crossref
11. Neer CS 2nd. Fracture of the distal clavicle with detachment of the coracoclavicular ligaments in adults. J Trauma. 1963. 3:99–110.
crossref
12. Neer CS 2nd. 5 Fractures of the distal third of the clavicle. . Clin Orthop Relat Res. 1968. 58:43–50.
crossref
13. Park JY, Seo JB, Kim MH, Yu JW. Tension band fixation for type II fracture of the distal clavicle. J Korean Fract Soc. 2005. 18:421–425.
crossref
14. Rockwood CA. Fractures of the outer clavicle in children and adults. J Bone Joint Surg Br. 1982. 64:642.
TOOLS
Similar articles