Journal List > J Korean Fract Soc > v.23(4) > 1037782

Seo, Joo, and Kim: False Negative Bone Scan in 56-year Old Man with L2 Compression Fracture Performed 78 Hours after Trauma - A Case Report -

Abstract

It is very rare that the bone scan after 72 hours from the trauma doesn't exhibit the increased radio-nuclide uptake in the patient with fracture. The purpose of this study is to report the case that indicate the false negative finding in the bone scan performed after 78 hours from the trauma in the 56-year-old man with L2 compression fracture, including a review of the relevant literatures.

Figures and Tables

Fig. 1
Radiographs show anterior compression and kyphosis of L2 vertebral body in AP and lateral view.
jkfs-23-386-g001
Fig. 2
CT scan shows compression of L2 vertebral body.
jkfs-23-386-g002
Fig. 3
Bone scan performed at 78 hours of post-trauma shows no abnormal uptake in L2 vertebra.
jkfs-23-386-g003
Fig. 4
MRI performed at 2 months after trauma shows signals indicating recently developed compression fracture of L2 vertebra.
jkfs-23-386-g004
Fig. 5
Bone scan performed at 2 months after trauma shows increased uptake in L2 vertebra.
jkfs-23-386-g005

References

1. Jung JH, Kim JK, Jin W, et al. The value of radionuclide imaging as a screening test for the diagnosis of an acute thoracic spinal fractures. J Korean Soc Emerg Med. 2005. 16:1–5.
2. Kaye M, Silverton S, Rosenthall L. Technetium-99m-pyrophosphate: studies in vivo and in vitro. J Nucl Med. 1975. 16:40–45.
3. Kim BH, Im JI, Kim DJ, Park JY. Diganostic values of bone scan followed by CT scan in undetected pelvic bone fracture. J Korean Orthop Assoc. 1997. 32:523–529.
crossref
4. Kim HR, Thrall JH, Keyes JW Jr. Skeletal scintigraphy following incidental trauma. Radiology. 1979. 130:447–451.
crossref
5. Lee E, Worsley DF. Role of radionuclide imaging in the orthopedic patient. Orthop Clin North Am. 2006. 37:485–501.
crossref
6. Matheson GO, Clement DB, McKenzie DC, Taunton JE, Lloyd-Smith DR, MacIntyre JG. Stress fractures in athletes. A study of 320 cases. Am J Sports Med. 1987. 15:46–58.
7. Matin P. The appearance of bone scans following fractures, including immediate and long-term studies. J Nucl Med. 1979. 20:1227–1231.
8. Milgrom C, Chisin R, Giladi M, et al. Negative bone scans in impending tibial stress fractures. A report of three cases. Am J Sports Med. 1984. 12:488–491.
crossref
9. Scott S, Alazraki N, Manaster B. Failure of bone scanning to detect fractures in a woman on chronic steroid therapy. Skeletal Radiol. 1984. 12:204–207.
crossref
10. Sterling JC, Webb RF Jr, Meyers MC, Calvo RD. False negative bone scan in a female runner. Med Sci Sports Exerc. 1993. 25:179–185.
crossref
11. Subramanian G, McAfee JG. A new complex of 99mTc for skeletal imaging. Radiology. 1971. 99:192–196.
12. Wen DY, Propeck T, Singh A. Femoral neck stress injury with negative bone scan. J Am Board Fam Pract. 2003. 16:170–174.
crossref
13. Yao L, Lee JK. Occult intraosseous fracture: detection with MR imaging. Radiology. 1988. 167:749–751.
crossref
TOOLS
Similar articles