Journal List > J Korean Fract Soc > v.22(3) > 1037703

Byun and Shin: Intramedullary Nailing of Proximal Tibial Fractures

Figures and Tables

Fig. 1
Radiographs show a healed fracture of the proximal tibia with valgus deformity and apex anterior deformity after locked nail.
jkfs-22-197-g001
Fig. 2
The CT scan of the proximal tibia shows triangular shape of the medullary canal with most narrow medial portion. The proximal-medial portion of the tibia is a chute (white arrow) that deflects the nail laterally because of lessened sagittal space and pronounced lateral slope of the medial cortex of the proximal tibia.
jkfs-22-197-g002
Fig. 3
Medial entry point and laterally directed insertion angle of the nail into the proximal fragment results in valgus malalignment as the nail engages into the distal fragment.
jkfs-22-197-g003
Fig. 4
Posteriorly directed insertion of the nail into the proximal fragment results in apex anterior angulation at the fracture site when the nail engages into the distal fragment.
jkfs-22-197-g004
Fig. 5
Lateral radiograph of the proximal tibial fracture treated with an AO unreamed interlocking nail shows anterior displacement of the proximal fragment (posterior displacement of the distal fragment) by the wedge effect of the nail. Note. The AO unreamed interlocking nail has a more distally located Herzog bend.
jkfs-22-197-g005
Fig. 6
Postoperative radiographs of this proximal tibial shaft fracture show good alignment after locked tibial nailing using the lateral starting point in line with the lateral intercondylar eminence and more proximal and posterior starting point.
jkfs-22-197-g006
Fig. 7
(A, B) Initial radiographs show simple oblique fracture of the proximal tibia.
(C, D, E) The fracture was reduced and alignment was maintained by temporary percutaneous use of pointed reduction forceps during nailing procedures.
(F, G) Postoperative radiographs show anatomical reduction of the fracture after fixing with a locked tibial nail and adjunctive percutaneous lag screws.
jkfs-22-197-g007
Fig. 8
(A, B) Initial radiographs show the proximal tibial fracture at the proximal meta-diaphyseal junction.
(C, D) Postoperative radiographs show good alignment of the fracture fixed with a locked tibial nail and blocking screws to prevent malalignment. A blocking screw was placed lateral to the central axis to prevent valgus angulation and the other blocking screw was placed posterior to the central axis to prevent apex anterior angulation.
jkfs-22-197-g008
Fig. 9
(A, B) Initial radiographs show the segmental fracture of the proximal and distal tibial shafts.
(C, D) The proximal fracture was reduced and stabilized with a 1/3 tubular plate through a small incision before locked tibial nailing to prevent malalignment. Postoperative radiographs show anatomical alignment of the fracture fixed with a locked nail and a small plate.
(E, F) Radiographs 7 months after surgery show the healed fracture with external callus in good alignment.
jkfs-22-197-g009

References

1. Benirschke SK, Henley MB, Ott JW. Proximal onethird tibial fracture solution. Orthop Trans. 1994; 18:1055–1056.
2. Bolhofner BR. Indirect reduction and composite fixation of extraarticular proximal tibial fractures. Clin Orthop Relat Res. 1995; 315:75–83.
crossref
3. Bono CM, Levine RG, Rao JP, Bebrens FF. Nonarticular proximal tibia fractures: treatment options and decision making. J Am Acad Orthop Surg. 2001; 9:176–186.
crossref
4. Buehler KC, Green J, Woll TS, Duwelius PJ. A technique for intramedullary nailing of proximal third tibia fractures. J Orthop Trauma. 1997; 11:218–223.
crossref
5. Cannada LK, Anglen JO, Archdeacon MT, Herscovici D Jr, Ostrum RF. Avoiding complications in the care of fractures of the tibia. Instr Course Lect. 2009; 58:27–36.
6. Freedman EL, Johnson EE. Radiographic analysis of tibial fracture malalignment following intramedullary nailing. Clin Orthop. 1995; 315:25–33.
crossref
7. Gerber A, Ganz R. Combined internal and external osteosynthesis. A biological approach to the treatment of complex fractures of the proximal tibia. Injury. 1998; 29:Suppl 3. C22–C28.
crossref
8. Gosling T, Schandelmaier P, Muller M, Hankemeier S, Wagner M, Krettek C. Single lateral locked screw plating of bicondylar tibial plateau fractures. Clin Orthop Relat Res. 2005; 439:207–214.
crossref
9. Henley MB, Meier M, Tencer AF. Influences of some design parameters on the biomechanics of the undreamed nail. J Orthop Trauma. 1993; 7:311–319.
crossref
10. Hicks CA, Noble P, Tullos H. The anatomy of the tibial intramedullary canal. Clin Orthop Relat Res. 1995; 321:111–116.
crossref
11. Hutson JJ Jr, Zych GA. Infections in periarticular fractures of the lower extremity treated with tensioned wire hybrid fixators. J Orthop Trauma. 1998; 12:214–218.
crossref
12. Keating JF, Kuo RS, Court-Brown CM. Bifocal fractures of the tibia and fibula. Incidence, classification and treatment. J Bone Joint Surg Br. 1994; 76:395–400.
crossref
13. Kim JW, Oh CW, JK Oh, et al. Staged minimally invasive plate osteosynthesis of proximal tibial fracture. J Korean Fract Soc. 2009; 22:6–12.
crossref
14. Krettek C, Gerich T, Miclau T. A minimally invasive medial approach for proximal tibial fractures. Injury. 2001; 32:Suppl 1. SA4–SA13.
crossref
15. Krettek C, Miclau T, Schandelmaier P, Stephan C, Möhlmann U, Tscherne H. The mechanical effect of blocking screws ("Poller screws") in stabilizing tibia fractures with short proximal or distal fragments after insertion of small-diameter intramedullary nails. J Orthop Trauma. 1999; 13:550–553.
crossref
16. Krettek C, Stephan C, Schandelmaier P, Richter M, Pape HC, Miclau T. The use of Poller screws as blocking screws in stabilizing tibial fractures treated with small diameter intramedullary nails. J Bone Joint Surg Br. 1999; 81:963–968.
17. Laflamme GY, Heimlich D, Stephen D, Kreder HJ, Whyne CM. Proximal tibial fracture stability with intramedullary nail fixation using oblique interlocking screws. J Orthop Trauma. 2003; 17:496–502.
crossref
18. Lang JG, Cohen BE, Bosse MJ, Kellam JF. Proximal third tibial shaft fractures. Should they be nailed? Clin Orthop. 1995; 315:64–74.
19. Mueller CA, Eingartner C, Schreitmueller E, et al. Primary stability of various forms of osteosynthesis in the treatment of fractures of the proximal tibia. J Bone Joint Surg Br. 2005; 87:426–432.
crossref
20. Müller ME, Allgöwer M, Schneider R, Willenegger H. Manual of internal fixation. 3rd ed. Berlin, Germany: Springer-Verlag;1992. p. 291–365.
21. Nicoll EA. Fractures of the tibial shaft. A survey of 705 cases. J Bone Joint Surg Br. 1964; 46:373–387.
22. Nork SE, Barei DP, Schildhauer TA, et al. Intramedullary nailing of proximal quarter tibial fractures. J Orthop Trauma. 2006; 20:523–528.
crossref
23. Phisitkul P, Mckinley TO, Nepola JV, Marsh JL. Complications of locking plate fixation in complex proximal tibia injuries. J Orthop Trauma. 2007; 21:83–91.
crossref
24. Ricci WM, O'Boyle M, Borrelli J, Bellabarba C, Sanders R. Fractures of the proximal third of the tibial shaft treated with intramedullary nails and blocking screws. J Orthop Trauma. 2001; 15:264–270.
crossref
25. Safran O, Liebergall M, Segal D, Mosheiff R. Proximal tibial fractures - should we nail them? Am J Orthop. 2001; 30:681–684.
26. Sarmiento A, Gersten LM, Sobol PA, Shankwiler JA, Vangsness CT. Tibial fractures treated with functional braces. J Bone Joint Surg Br. 1989; 71:602–609.
27. Tornetta P 3rd. Technical considerations in the surgical management of tibial fractures. Instr Course Lect. 1997; 46:271–280.
28. Tornetta P 3rd, Collins E. Semiextended position of intramedullary nailing of the proximal tibia. Clin Orthop. 1996; 328:185–189.
TOOLS
Similar articles