Abstract
Purpose
To evaluate clinical and radiographic results of open reduction and internal fixation with plate in AO type C3 distal radius fracture.
Materials and Methods
We treated 18 fractures and the mean follow up was 16 months. The average age was 47.1 years old, 12 male and 6 female were included. There were 9 C3.1 fracture, 5 C3.2 and 4 C3.3. Green & O'Brien's modified clinical scoring system and Demerit Point system were applied to evaluate clinical results, for radiographic evaluation, radial length, radial inclination, volar tilt, and Sarmiento's Criteria for Anatomic results were assessed.
Results
Clinical results were 5 of excellent, 7 of good, and 6 of fair by Green & O'Brien's score and were 5 of excellent, 6 of good, and 7 of fair by Demerit point. There was no significant difference of radiographic results between immediate postoperation and last follow-up, and Sarmiento's Criteria showed 8 excellent, 4 good, and 6 fair.
References
1. Arora J, Malik AC. External fixation in comminuted, displaced intra-articular fractures of the distal radius: is it sufficient? Arch Orthop Trauma Surg. 2005; 125:536–540.
2. Arora R, Lutz M, Fritz D, Zimmermann R, Oberladstatter J, Gabl M. Palmar locking plate for treatment of unstable dorsal dislocated distal radius fractures. Arch Orthop Trauma Surg. 2005; 125:399–404.
3. Bassett RL. Displaced intraarticular fractures of the distal radius. Clin Orthop Relat Res. 1987; (214):148–152.
4. Bienek T, Kusz D, Cielinski L. Peripheral nerve compression neuropathy after fractures of the distal radius. J Hand Surg Br. 2006; 31:256–260.
5. Bradway JK, Amadio PC, Cooney WP. Open reduction and internal fixation of displaced, comminuted intra-articular fractures of the distal dnd of the radius. J Bone Joint Surg Am. 1989; 71:839–847.
6. Cho CH, Bae KC, Kwon DH. Volar T-locking compression plate for treatment of unstable distal radius fractures. J Korean Fract Soc. 2008; 21:220–224.
7. Gautier E, Sommer C. Guidelines for the clinical application of the LCP. Injury. 2003; 34:B63–B76.
8. Green DP, Brein ET. Open reduction of carpal dislocation: indication and operative techniques. J Hand Surg Am. 1978; 3:250–265.
9. Grewal R, Perey B. A randomized prospective study on the treatment on intra-articular distal radius fractures: open reduction and internal fixation with dorsal plating versus mini open reduction, percutaneous fixation and external fixation. J Hand Surg Am. 2005; 30:764–772.
10. Jupiter JB. Current concepts review: fractures of the distal end of the radius. J Bone Joint Surg Am. 1991; 73:461–469.
11. Jupiter JB, Ring D, Weitzel PP. Surgical treatment of redisplaced fractures of the distal radius in patients older than 60 years. J Hand Surg Am. 2002; 27:714–723.
12. Kamano M, Koshimune M, Toyama M, Kazuki K. Palmar plating system for Colles' fractures-a preliminary report. J Hand Surg Am. 2005; 30:750–755.
13. Knirk JL, Jupiter JB. Intra-articular fractures of the distal end of the radius in young adults. J Bone Joint Surg Am. 1986; 68:647–659.
15. Letsch R, Infanger M, Schmidt J, Kock HJ. Surgical treatment of fractures of the distal radius with plates: a comparison of palmar and dorsal plate position. Arch Orthop Trauma Surg. 2003; 123:333–339.
16. Leung F, Zhu L, Ho H, Lu WW, Chow SP. Palmar plate fixation of AO type C2 fracture of the distal radius using a locking compression plate-a biomechanical study in a cadeveric model. J Hand Surg Br. 2003; 28:263–266.
17. Medoff RJ, Kopylov P. Immediate internal fixation and motion of comminuted distal radius fractures using a new fragment specific fixation system. Orthop Trans. 1998; 22:165.
18. Mudgal CS, Jupiter JB. Plate fixation of osteoporotic fractures of the distal radius. J Orthop Trauma. 2008; 22:S106–S115.
19. Orbay JL. The treatment of unstable distal radius fractures with volar fixation. Hand Surg. 2000; 5:103–112.
20. Orbay JL, Fernandez DL. Volar fixation for dorsally displaced fractures of the distal radius: a preliminary report. J Hand Surg Am. 2002; 27:205–215.
21. Papadonikolakis A, Shen J, Garrett JP, Davis SM, Ruch DS. The effect of increasing distraction on digital motion after external fixation on the wrist. J Hand Surg Am. 2005; 30:773–779.
22. Putnam MD, Fischer MD. Treatment of unstable distal radius fractures: methods and comparison of external distraction and ORIF versus external distraction-ORIF neutralization. J Hand Surg Am. 1997; 22:238–251.
23. Rein S, Schikore H, Schneiders W, Amalang M, Zwipp H. Results of dorsal or volar plate fixation of AO type C3 distal radius fractures: a retrospective study. J Hand Surg Am. 2007; 32:954–961.
24. Ring D, Rrommersberger K, Jupiter JB. Combined dorsal and volar plate fixation of complex fractures of the distal part of the radius. J Bone Joint Surg Am. 2004; 86:1646–1652.
25. Rogachefsky RA, Lipson SR, Applegate B, Ouellette EA, Savenor AM, McAuliffe JA. Treatment of severly comminuted intra-articular fracture of the distal end of the radius by open reduction and combined internal and external fixation. J Bone Joint Surg Am. 2001; 83:509–519.
26. Rozental TD, Beredjiklian PK, Bozentka DL. Functional outcome and complications following two types of dorsal plating for unstable fractures of the distal part of the radius. J Bone Joint Surg Am. 2003; 85:1956–1960.
27. Rozental TD, Blazar PE. Functional outcome and complications after volar plating for dorsally displaced, unstable fractures of the distal radius. J Hand Surg Am. 2006; 31:359–365.
28. Sarmiento A, Aratt GW, Berry NC, Sinclair WF. Colles' fracture: functional bracing in supination. J Bone Joint Surg Am. 1975; 57:311–317.
29. Sarmiento A, Zagorski JB, Sinclair WF. Functional bracing of Colles' fracture: a prospective study of immobilization in supination vs. pronation. Clin Orthop Relat Res. 1980; 146:175–183.
30. Schneeberger AG, Ip WY, Poon TL, Chow SP. Open reduction and plate fixation of displaced AO type C3 fractures of the distal radius: restoration of articular congruity in eighteen cases. J Orthop Trauma. 2001; 15:350–357.
31. Szabo RM, Weber SC. Comminuted intraarticular fractures of the distal radius. Clin Orthop Relat Res. 1988; 230:39–48.
32. Trumble TE, Culp RW, Hanel DP, Geissler WB, Berger RA. Intra-articular fractures of the distal aspect of the radius. Instr Course Lect. 1999; 48:465–480.
33. Wagner M. General principle for the clinical use of LCP. Injury. 2003; 34:Suppl 2. B31–B42.
34. Young BT, Rayan GM. Outcome following nonoperative treatment of displaced distal radius fractures in low-demand patients older than 60 years. J Hand Surg Am. 2000; 25:19–28.
35. Zhang SX, Gu FR. External fixation and bone grafting for collapsed and comminuted distal radius fracture. Chin J Traumatol. 2005; 8:156–159. 164