Journal List > J Korean Fract Soc > v.22(3) > 1037691

Jeon, Park, Song, Kim, and Yun: The Comparison between ITST™ (Intertrochanteric/Subtrochanteric) & DHS (Dynamic Hip Screw) in Unstable Femur Intertrochanteric Fracture

Abstract

Purpose

To evaluate between DHS and ITST nail (2nd generation) on the treatment of unstable femur intertrochanteric fracture in patients over 70 years old.

Materials and Methods

61 cases of unstable intertrochanteric fracture (grouped 37 patients with DHS and 24 patients with ITST) who were taken the operation from Mar. 2003 to Sep. 2007 were analysed regarding to union time, sliding length of lag screws, operation time, blood loss, postoperative complications and functional recovery score by Skovron.

Results

The mean union time was 14.7 weeks in study group (ITST). The mean union time was 16.2 weeks in control group (DHS). The lag screw slidings were 7.2 mm in study group and 8.7 mm in control group. The operation times were 57.9 min in study group and 76.9 min in control group. The amount of blood loss were 67.7 ml in study group and 227.4 ml in control group. The complications were 4 cases in study group and 4 cases in control group. The Skovron recovery scores were 76.5% in study group and 73.7% in control group.

Conclusion

From a practical point of short operation time, less amount of bleeding and less complication, author think that the ITST nail is useful implant for treatment of unstable femur intertrochanteric fracture in patient of old age.

Figures and Tables

Fig. 1
(A) Initial radiograph in 84-year-old woman shows unstable intertrochanteric fracture according to EVANS classification.
(B, C) Immediate postoperative radiograph of internal fixation with DHS and TSP.
(D, E) Postoperative 14 months radiograph shows complete union of fracture site, 3 mm slippage of lag screw and 3 degree change of neck-shaft angle without lateral displacement of greater trochanter.
jkfs-22-131-g001
Fig. 2
(A, B) Initial radiograph in 76-year-old man shows unstable intertrochanteric fracture according to EVANS classification.
(C, D) Immediate postoperative radiograph shows that fixation was done with ITST, lag screw was placed in center.
(E, F) Postoperative 8 months radiograph shows complete union of fracture site, 2 mm slippage of lag screw.
jkfs-22-131-g002
Table 1
Comparison between DHS and ITST in unstable intertrochanteric fracture
jkfs-22-131-i001

*W.B.: Weight bearing, p<0.05.

References

1. Ahn SJ, Park JH. Proximal femoral nail (PFN) for the treatment of the femoral trochanteric fracture. J Korean Fract Soc. 2004; 17:7–12.
crossref
2. Babst R, Renner N, Biedermann M, et al. Clinical results using the trochanter stabilizing plate (TSP): the modular extension of the dynamic hip screw (DHS) for internal fixation of selected unstable intertrochanteric fractures. J Orthop Trauma. 1998; 12:392–399.
crossref
3. Banan H, Al-Sabti A, Jimulia T, Hart AJ. The treatment of unstable extracapsular hip fractures with the AO/ASIF proximal femoral nail (PFN)-our 60 cases. Injury. 2002; 33:401–405.
crossref
4. Bridle SH, Patel AD, Bircher M, Calvert PT. Fixation of intertrochanteric fractures of the femur. A randomized prospective comparison of the gamma nail and the dynamic hip screw. J Bone Joint Surg Br. 1991; 73:330–334.
5. Butt MS, Krikler SJ, Nafie S, Ali MS. Comparison of dynamic hip screw and gamma nail: a prospective, randomized controlled trial. Injury. 1995; 26:615–618.
crossref
6. Chang JS, Kim KY, Lee SH, Ahn HS, Han BH, Hong SW. Treatment of comminuted trochanteric fractures with DHS and DHS TSP. J Korean Orthop Assoc. 1997; 32:1206–1213.
crossref
7. Chevalley F, Gamba D. Gamma nailing of pertorchanteric and subtrochanteric fractures: clinical results of a series of 63 conservative cases. J Orthop Trauma. 1997; 11:412–415.
crossref
8. Evans EM. Trochanteric fractures: a review of 110 cases treated by nail-plate fixation. J Bone Joint Surg Br. 1951; 33B:192–204.
9. Gross M. A critique of the methodologies used in clinical studies of hip joint arthroplasty published in the English language orthopaedic literature. J Bone Joint Surg Am. 1988; 70:1364–1371.
crossref
10. Hardy DC, Descamps PY, Krallis P, et al. Use of and intramedullary hip screw compared with a compression hip screw with a plate for intertrochanteric femoral fractures. A prospective, randomized study of one hundreds patients. J Bone Joint Surg Am. 1998; 80:618–630.
11. Jensen JS, Sonne-Holm S, Tøndevold E. Unstable trochanteric fractures. A comparative analysis of four methods of internal fixation. Acta Orthop Scand. 1980; 51:949–962.
crossref
12. Koval KJ, Zuckerman JD. Hip fractures: II. Evaluation and treatment of inter-trochanteric fractures. J Am Acad Orthop Surg. 1994; 2:150–156.
crossref
13. Leung KS, So WS, Shen WY, Hui PW. Gamma nails and dynamic hip screw for peritrochanteric fractures. A randomized prospective study in elderly patients. J Bone Joint Surg Br. 1992; 74:345–351.
14. Madsen JE, Naess L, Aune AK, Alho A, Ekeland A, Stromsoe K. Dynamic hip screw with trochanteric stabilizing plate in the treatment of unstable proximal femoral fractures: a comparative study with the gamma nail and compression hip screw. J Orthop Trauma. 1998; 12:241–248.
crossref
15. Martin DP, Engelberg R, Agel J, Swiontkowski MF. Comparison of the musculoskeletal function assessment questionnaire with the short form-36, the western ontario and mcmaster universities osteoarthritis index, and the sickness impact profile health status measures. J Bone Joint Surg Am. 1997; 79:1323–1335.
crossref
16. Mueller ME, Nazarian S. Classification et documentation aoedes fractures du femur. Rev Chir Orthop. 1981; 67:297.
17. Shon WY, Park JH, Kil KH, Jeon SJ, Suh SW. Functional recovery after operative treatment of hip fractures in the elderly. J Korean Orthop Assoc. 1998; 33:968–973.
crossref
18. Park SW, Baek JR, Moon IS. Treatment of unstable intertrochanteric fractures in elderly patients: comparison between DHS and additional TSP. J Korean Soc Fract. 2003; 16:9–14.
crossref
19. Rosenblum SF, Zuckerman HD, Kummer FJ, Tam BS. A biomechanical evaluation of the gamma nail. J Bone Joint Surg Br. 1992; 74:352–357.
crossref
20. Shin DK, Kwon KW, Kim SK, Lee SW, Choi CH, Kim KM. Treatment of femoral intertrochanteric fracture with proximal femoral Nail. J Korean Soc Fract. 2002; 15:328–335.
21. Skovron ML, Koval KJ, Aharonoff GB, Zuckerman JD. Outcome assessment after fracture in the elderly. Instr Course Lect. 1997; 46:439–443.
22. Sohn OJ, Kim SD, Kim IW, Byun SJ. A comparative study of trochanteric fractures treated with the Intertrochanteric/subtrochanteric fixation or the proximal femoral nail. J Korean Fract Soc. 2006; 19:303–308.
crossref
23. Steinberg GG, Desai SS, Sullivan TJ. The intertrochanteric hip fracture. Orthopedics. 1988; 11:265–273.
24. Watson JT, Moed BR, Cramer KE, Kareges DE. Comparison of compression hip screw with the Medoff sliding plate for intertrochanteric fractures. Clin Orthop Relat Res. 1998; (348):79–86.
TOOLS
Similar articles