Journal List > J Korean Soc Spine Surg > v.15(4) > 1035820

Kim, Kang, Sung, Park, Park, Kim, and Choy: Metal Failure in patients with Short-segmental Pedicle Screw Fixation and Fusion for Degenerative Lumbar Disease: Comparison Monoaxial with Polyaxial Screw

Abstract

Study Design

Retrospective study Objective:To evaluate the factors affecting metal failure and screw loosening of short-segmental (1- or 2-segmental) monoaxial or polyaxial screw fixation for degenerative lumbar disease.

Summary of Literature Review

There was a report on metal failure and screw loosening in short-segmental monoaxial and polyaxial screw fixation in degenerative lumbar disease.

Materials and Methods

This study examined 227 cases who underwent short-segmental transpedicular screw fixation and vertebral fusion for a degenerative lumbar. (Ed note: You need to define groups A and B.)

Results

Metal failure of transpedicular screws was detected in 6 cases, 3 each in groups A and B. Screw loosening occurred in 16 and 43 cases in group A and B, respectively. Both groups had a similar incidence of spinal stenosis with instability and spondylolisthesis. The failure rate and screw loosening according to the fusion level was also similar. The failure and screw loosening rates was higher in the cases who did not undergo PLIF than in the cases who underwent PLIF but the difference was not statistically significant.

Conclusion

The metal failure and screw loosening rates after transpedicular screw fixation and spinal fusion procedures for degenerative lumbar diseases using monoaxial screws and polyaxial screws were similar.

REFERENCES

01). Sanden B., Olerud C., Petren-Mallmin M., Johansson ., Larsson S. The significance of radiolucent zones surrounding pedicle screws: Definition of screw loosening in spinal instrumentation. J Bone and Joint Surg Br,. 2004. 86:457–461.
02). Krag MH., Beynnon BD., Pope MH., Frymoyer JW., Haugh LD. An internal fixation for posterior application to short segments for the thoracic, lumbar, or lumbosacral spine: Design and testing. Clin. Orthop. 1986. 203:75–98.
03). Roy-Camille R., Saillant G., Mazel C. Plating or thoracic, thoracolumbar and lumbar injuries with pedicle screw plates. Ortho. Clin. North Am,. 1986. 17:147–159.
04). Boucher HH. A method of spinal fusion. J Bone and Joint Surg Br,. 1959. 41:248–259.
crossref
05). Harrington PR., Tullos HS. Reconstruction of severe spondylolisthesis in children. South Med J,. 1969. 62:1–7.
06). Steffee A., Biscup R., Stickowski D. Segmental spine plates with pedicle screws fixation: A new internal fixation device for disorders of the lumbar and thoracic spine. Clin. Orthop. 1986. 203:45–53.
07). Lee KY., Kim CH., Song CG. Metal failure of pedicle screw system. J Kor Soc Surg,. 2002. 9:157–163.
crossref
08). Shin BJ., Kim KJ., Kim ST., Kim YI. Survivorship analysis of pedicle screw fixation. J Kor Soc Surg,. 1999. 6:355–361.
09). McAfee PC., Farey ID., Sutterlin CE., Gurr KR., Wrden KE., Cunningham BW. The effect of spinal implant rigidity on vertebral bone density: a canine model. Spine,. 1991. 16:190–197.
10). Okuyama K., Abe K., Suzuki T., Tamura Y., Chiba M., Sato K. Posterior lumbar interbody fusion. A retrospective study of complication after facet joint excision and pedicle screw fixation in 148 cases. Acta Orthop Scand,. 1999. 10:329–334.
11). Ohlin A., Karlsson M., Dupe H., Harserius R., Redlund-Hohnell I. Complication after transpedicular stabilization of the spine. Spine. 1994. 19:2774–2779.
12). Schatzker J., Horne JG., Sumner-Smith G. The effect of movement on the holding power of screws in bone. Clin. Orthop. 1975. 111:257–262.
13). Kuklo TR., Potter BK., Polly DW., Lenke LG. Monaxial versus thoracic pedicle screws in the correction of adolescent idiopathic scoliosis. Spine,. 2005. 30:2113–2120.
14). Stanford RE., Loefler AH., Stanford PM., Walsh WR. Multiaxial pedicle screw designs: Static and dynamic mechanical testing. Spine,. 2004. 29:367–375.
crossref
15). Fogel GR., Reitman CA., Liu W., Esses SI. Physical characteristics of polyaxial-head pedicle screws and biomechanical comparison of load with their failure. Spine,. 2003. 28:470–473.
16). Chen SH., Lin RM., Chen HH., Tsai KJ. Biomechanical effects of ployaxial pedicle screw fixation on the lumbosacral segments with an anterior interbody cage support. BMC Musculoskeletal Disorder,. 2007. 8:28.
crossref

Fig. 1.
59-year-old patient with spinal stenosis of the lumbar spine. A continuous lucency at the screw-bone interface surrounded by a thin radiolucent zone (halo sign-black arrows) on the AP radiograph indicates loosening of both distal screws on 4 months follow up.
jkss-15-243f1.tif
Fig. 2.
62-year-old patient with spinal stenosis shows pull-out (black arrow) of screws from the vertebral body due to increase of kyphosis of the lumbar spine on 4 months (A) and 10 months (B) follow up.
jkss-15-243f2.tif
Fig. 3.
67-year-old patient with spinal stenosis shows screw-rod dissociation on 2 months follow up.
jkss-15-243f3.tif
Table 1.
Metallic failures in group A and group B
    Group A Group B Total
Diseases Spinal stenosis with instability 3 2 5
  Spondylolisthesis 0 1 1
Fixation segment 1-segment 0 2 2
  2-segments 3 1 4
PLIF Yes 1 0 1
  No 2 3 5
Total   3 3 6
Table 2.
Halo signs in group A and group B
    Group A Group B Total
Diseases Spinal stenosis with instability 9 22 31
  Spondylolisthesis 7 21 28
Fixation segment 1-segment 10 29 39
  2-segments 6 14 20
PLIF Yes 2 11 13
  No 14 32 46
Total   16 43 59