Journal List > J Korean Acad Prosthodont > v.55(4) > 1034947

Park, Shin, Ryu, Lee, and Shin: Flexibility of resin splint systems for traumatized teeth

Abstract

Purpose

The aim of this study is to evaluate the flexural strength of flexible resins and the flexibility of different resin splint (RS) systems in comparison with resin wire splint (RWS) system.

Materials and methods

Three different resin materials (G-aenial flo, GA, GC; Superbond, SB, Sun medical; G-fix, GF, GC) were tested flexural strength test in accordance with ISO-4049:2000. For the flexibility test of splint systems, a artificial model with resin teeth was used to evaluate three types of resin splint systems (GA, SB, and GF) and one resin wire splint system. The left central incisor was simulated ‘injured teeth’ with third degree mobility. Three consecutively repeated measurements of periotest value were taken in horizontal direction, before and after splinting to access tooth mobility. The splinting effect was calculated through the periotest value. Differences were evaluated through One-way Anova and Tukey HDS post-hoc tests for pair-wise comparison (α= .05).

Results

Although GA group showed significant higher flexural strength than SB and GF groups, all of three different resin splint systems produced a significantly higher and rigid splinting effect compared with 016" resin-wire splint system (P < .05).

Conclusion

Within the limits of an in vitro study, it can be stated that resin splint systems are too rigid and may not be acceptable to treat tooth avulsion.

Figures and Tables

Fig. 1

Three point bending test.

jkap-55-389-g001
Fig. 2

Experimental model of splinting effect test.

jkap-55-389-g002
Fig. 3

Mean flexural strength (MPa) of the resins.

jkap-55-389-g003
Fig. 4

Mean splinting effect (%) of splinting systems.

jkap-55-389-g004
Table 1

Materials used in this study

jkap-55-389-i001
Table 2

Test groups and number of specimens for splinting effect test

jkap-55-389-i002

References

1. Andreasen JO, Andreasen FM. Textbook and colour atlas of traumatic injuries to the teeth. 3rd ed. Copenhagen: Munksgaard;1994. p. 155. p. 383. p. 425. .
2. Soares AJ, Gomes BP, Zaia AA, Ferraz CC, de Souza-Filho FJ. Relationship between clinical-radiographic evaluation and outcome of teeth replantation. Dent Traumatol. 2008; 24:183–188.
crossref
3. Gutmann JL, Gutmann MS. Cause, incidence, and prevention of trauma to teeth. Dent Clin North Am. 1995; 39:1–13.
crossref
4. Glendor U, Halling A, Andersson L, Eilert-Petersson E. Incidence of traumatic tooth injuries in children and adolescents in the county of Västmanland, Sweden. Swed Dent J. 1996; 20:15–28.
5. Ram D, Cohenca N. Therapeutic protocols for avulsed permanent teeth: review and clinicalupdate. Pediatr Dent. 2004; 26:251–255.
6. Kwan SC, Johnson JD, Cohenca N. The effect of splint material and thickness on tooth mobility afterextraction and replantation using a human cadaveric model. Dent Traumatol. 2012; 28:277–281.
crossref
7. Andersson L, Andreasen JO, Day P, Heithersay G, Trope M, Diangelis AJ, Kenny DJ, Sigurdsson A, Bourguignon C, Flores MT, Hicks ML, Lenzi AR, Malmgren B, Moule AJ, Tsukiboshi M. International association of dental traumatology guidelines for the management of traumatic dental injuries: 2. Avulsion of permanent teeth. Dent Traumatol. 2012; 28:88–96.
crossref
8. Ram D, Cohenca N. Therapeutic protocols for avulsed permanent teeth: review and clinicalupdate. Pediatr Dent. 2004; 26:251–255.
9. Andreasen JO, Andreasen FM, Mejàre I, Cvek M. Healing of 400 intra-alveolar root of treatmentfactors such as treatment delay, repositioning, splinting type and period and antibiotics. Dent Traumatol. 2004; 20:203–211.
crossref
10. Frost HM. A determinant of bone architecture. The minimum effective strain. Clin Orthop Relat Res. 1983; (175):286–292.
11. Frost HM. Skeletal structural adaptations to mechanical usage (SATMU):1. Redefining Wolff's law: the bone modeling problem. Anat Rec. 1990; 226:403–413.
crossref
12. Yasuda T, Kinoshita M, Abe M, Shibayama Y. Unfavorable effect of knee immobilization on Achilles tendon healing in rabbits. Acta Orthop Scand. 2000; 71:69–73.
crossref
13. Vailas AC, Tipton CM, Matthes RD, Gart M. Physical activity and its influence on the repair process of medialcollateral ligaments. Connect Tissue Res. 1981; 9:25–31.
crossref
14. Becker H, Diegelmann RF. The influence of tension in intrinsic tendon fibroplasia. Orthop Rev. 1984; 13:65–71.
15. American Association of Endodontists Guideline. Recommended guidelines of the AAE for the treatment of traumatic dental injuries. revised 2013. Available from: http://www.nxtbook.com/nxtbooks/aae/traumaguidelines/index.php.
16. Mazzoleni S, Meschia G, Cortesi R, Bressan E, Tomasi C, Ferro R, Stellini E. In vitro comparison of the flexibility of different splint systems used in dental traumatology. Dent Traumatol. 2010; 26:30–36.
crossref
17. Andresen M, Mackie I, Worthington H. The Periotest in traumatology. Part I. Does it have the properties necessary for use as a clinical device and can the measurements be interpreted? Dent Traumatol. 2003; 19:214–217.
crossref
18. Berthold C, Auer FJ, Potapov S, Petschelt A. In vitro splint rigidity evaluation-comparison of a dynamic and a static measuring method. Dent Traumatol. 2011; 27:414–421.
crossref
19. Berthold C, Holst S, Schmitt J, Goellner M, Petschelt A. An evaluation of the Periotest method as a tool for monitoring toothmobility in dental traumatology. Dent Traumatol. 2010; 26:120–128.
crossref
TOOLS
ORCID iDs

Jin-Hong Park
https://orcid.org/0000-0002-3220-9912

Jae-Jun Ryu
https://orcid.org/0000-0001-6903-5955

Jeong-Yol Lee
https://orcid.org/0000-0003-3079-0376

Sang Wan Shin
https://orcid.org/0000-0002-3100-2020

Similar articles