Abstract
The retention of complete dentures in patients with Parkinson’ s disease is often poor due to their constant dislodgement by involuntary movements of the tongue and lips. Furthermore, insertion of the overdenture is expected to be difficult due to their limited voluntary movements. This case is about the bimaxillary overdenture restoration where its retention and stability are improved, using magnetic attachment of remained roots of maxilla and two implant Locator® attachments of mandible in patients with Parkinson’ s disease. This report describes the fabrication of this functionally improved prosthesis.
REFERENCES
1. Ko E, Ahn S, Lee S, Park S, Lee RS. Oral rehabilitation with magnetic overdentures for an old patient with complex systemic diseases. J Korean Acad Prosthodont. 2015; 53:150–6.
2. Kent G. Effects of osseointegrated implants on psychological and social well-being: a literature review. J Prosthet Dent. 1992; 68:515–8.
3. Awad MA, Lund JP, Dufresne E, Feine JS. Comparing the efficacy of mandibular implant-retained overdentures and conventional dentures among middle-aged edentulous patients: satisfaction and functional assessment. Int J Prosthodont. 2003; 16:117–22.
4. Kim SU. Implant-supported removable prosthetic treatments with patient focus. Myungmoon: Seoul;2007.
5. Hing R, Daly C. Case report: Magnetically-retained overdenture for a patient with cerebral palsy. Aust Occup Ther J. 1985; 32:17–22.
6. Packer M, Nikitin V, Coward T, Davis DM, Fiske J. The potential benefits of dental implants on the oral health quality of life of people with Parkinson' s disease. Gerodontology. 2009; 26:11–8.
7. Brewer AA, Morrow RM. Overdentures. 2nd ed.Mosby;1980. p. 4–10.
8. Vrijhoef MM, Mezger PR, Van der Zel JM, Greener EH. Corrosion of ferromagnetic alloys used for magnetic retention of overdentures. J Dent Res. 1987; 66:1456–9.
9. Angelini E, Pezzoli M, Zucchi F. Corrosion under static and dy-namic conditions of alloys used for magnetic retention in dentistry. J Prosthet Dent. 1991; 65:848–53.
10. Drago CJ. Tarnish and corrosion with the use of intraoral magnets. J Prosthet Dent. 1991; 66:536–40.
11. Kitsugi A, Okuno O, Nakano T, Hamanaka H, Kuroda T. The corrosion behavior of Nd2Fe14B and SmCo5 magnets. Dent Mater J. 1992; 11:119–29.
12. Kuoppala R, Nä pä nkangas R, Raustia A. Quality of Life of Patients Treated With Implant-Supported Mandibular Overdentures Evaluated With the Oral Health Impact Profile (OHIP-14): a Survey of 58 Patients. J Oral Maxillofac Res. 2013; 4:e4.