Paek, Lee, Kim, Kim, Kim, Kwon, and Woo: A FEM study on stress distribution of tooth-supported and implant-supported overdentures retained by telescopic crowns

Abstract

Purpose

The purpose of this study was to investigate the stress distribution in mandibular implant-supported overdentures and tooth-supported overdentures with telescopic crowns.

Materials and methods

The assumption of this study was that there were 2, 3, 4 natural teeth and implants which are located in the second premolar and canine regions in various distributed conditions. The mandible, teeth (or implants and abutments), and connectors are modeled, and analyzed with the commercial software, ANSYS Version 10.1. Stress distribution was evaluated under 150 N vertical load bilaterally on 3 experimental conditions - between canine areas, canine and 2nd premolars, 10 mm posterior to 2nd premolars.

Results

Overall, the case of the implant group showed more stress than the case of the teeth group in stress distribution to bone. In stress distribution to superstructures of tooth and implants, there was no significant difference between TH group and IM group and the highest stress appeared in TH-IV and IM-IV. The stress caused from bar was much higher than those of implant and tooth. TH group showed less stress than IM group in stress distribution to abutment teeth and implant.

Conclusion

The results shows that it is crucial to make sure that distance between impact loading point and abutment tooth does not get too far apart, and if it does, it is at best to set abutment tooth on premolar tooth region. It will be necessary to conduct more experiments on effects on implants, natural teeth and bone, in order to apply these results to a clinical treatment.

Figures and Tables

Fig. 1
Finite element model of A: mandible, B: natural tooth (left), implant (right), and abutments, C: outer crown and connector.
jkap-50-10-g001
Fig. 2
Loading conditions A. LC1: Vertical load was applied between canines (150 N). B. LC2: Vertical load was applied between canine and 2nd premolars (150 N). C. LC3: Vertical load was applied on 10 mm posterior area to 2nd premolars (150 N).
jkap-50-10-g002
Fig. 3
Stress distributions of LC1 on peri-implant bone. A: TH-I, B: TH-II, C: TH-III, D: TH-IV, E: TH-V, F: TH-VI.
jkap-50-10-g003
Fig. 4
Stress distributions of LC2 on peri-implant bone. A: TH-I, B: TH-II, C: TH-III, D: TH-IV, E: TH-V, F: TH-VI.
jkap-50-10-g004
Fig. 5
Stress distributions of LC3 on peri-implant bone. A: TH-I, B: TH-II, C: TH-III, D: TH-IV, E: TH-V, F: TH-VI.
jkap-50-10-g005
Fig. 6
Stress distributions of LC1 on peri-implant bone. A: IM-I, B: IM-II, C: IM-III, D: IM-IV, E: IM-V, F: IM-VI.
jkap-50-10-g006
Fig. 7
Stress distributions of LC2 on peri-implant bone. A: IM-I, B: IM-II, C: IM-III, D: IM-IV, E: IM-V, F: IM-VI.
jkap-50-10-g007
Fig. 8
Stress distributions of LC3 on peri-implant bone. A: IM-I, B: IM-II, C: IM-III, D: IM-IV, E: IM-V, F: IM-VI.
jkap-50-10-g008
Table 1
Material properties
jkap-50-10-i001
Table 2
Classification of teeth and implants by the number and area in mandible
jkap-50-10-i002
Table 3
Maximum von Mises stress values in mandible (MPa)
jkap-50-10-i003

LC: load case, TH: tooth, IM: implant

Table 4
Maximum von Mises stress values in the prostheses (MPa)
jkap-50-10-i004

LC: load case, TH: tooth, IM: implant

Table 5
Maximum von Mises stress values in teeth and implants (MPa)
jkap-50-10-i005

LC: load case, TH: tooth, IM: implant

References

1. Brewer AA. Overdentures. 1980. 2nd ed. St. Louis: Mosby.
2. Fanuscu MI, Caputo AA. Influence of attachment systems on load transfer of an implant-assisted maxillary overdenture. J Prosthodont. 2004. 13:214–220.
crossref
3. van Kampen F, Cune M, van der Bilt A, Bosman F. Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment: an in vivo comparison after 3 months of function. Clin Oral Implants Res. 2003. 14:720–726.
crossref
4. Heckmann SM, Schrott A, Graef F, Wichmann MG, Weber HP. Mandibular two-implant telescopic overdentures. Clin Oral Implants Res. 2004. 15:560–569.
5. Engquist B, Bergendal T, Kallus T, Linden U. A retrospective multicenter evaluation of osseointegrated implants supporting overdentures. Int J Oral Maxillofac Implants. 1988. 3:129–134.
6. Hutton JE, Heath MR, Chai JY, Harnett J, Jemt T, Johns RB, McKenna S, McNamara DC, van Steenberghe D, Taylor R, et al. Factors related to success and failure rates at 3-year follow-up in a multicenter study of overdentures supported by Braånemark implants. Int J Oral Maxillofac Implants. 1995. 10:33–42.
7. Johns RB, Jemt T, Heath MR, Hutton JE, McKenna S, McNamara DC, van Steenberghe D, Taylor R, Watson RM, Herrmann I. A multicenter study of overdentures supported by Braånemark implants. Int J Oral Maxillofac Implants. 1992. 7:513–522.
crossref
8. Lekholm U, Zarb GA. Braånemark PI, Zarb GA, Albrektsson T, editors. Patient selection and preparation. Tissue integrated prostheses: Osseointegration in clinical dentistry. 1985. Chicago: Quintessence;199–209.
9. Goodacre CJ, Kan JY, Rungcharassaeng K. Clinical complications of osseointegrated implants. J Prosthet Dent. 1999. 81:537–552.
crossref
10. Naert I, De Clercq M, Theuniers G, Schepers E. Overdentures supported by osseointegrated fixtures for the edentulous mandible: a 2.5-year report. Int J Oral Maxillofac Implants. 1988. 3:191–196.
11. Yokoyama S, Wakabayashi N, Shiota M, Ohyama T. Stress analysis in edentulous mandibular bone supporting implant-retained 1-piece or multiple superstructures. Int J Oral Maxillofac Implants. 2005. 20:578–583.
12. Ralph WJ. The effects of dental treatment on biting force. J Prosthet Dent. 1979. 41:143–145.
crossref
13. Heckmann SM, Winter W, Meyer M, Weber HP, Wichmann MG. Overdenture attachment selection and the loading of implant and denture-bearing area. Part 2: A methodical study using five types of attachment. Clin Oral Implants Res. 2001. 12:640–647.
crossref
14. Menicucci G, Lorenzetti M, Pera P, Preti G. Mandibular implant-retained overdenture: finite element analysis of two anchorage systems. Int J Oral Maxillofac Implants. 1998. 13:369–376.
15. Krennmair G, Seemann R, Weinla¨nder M, Piehslinger E. Comparison of ball and telescopic crown attachments in implant-retained mandibular overdentures: a 5-year prospective study. Int J Oral Maxillofac Implants. 2011. 26:598–606.
16. Curry J. The mechanical adaptations of bones. 1984. Princeton University Press.
TOOLS
Similar articles