Park, Lee, Jung, Cho, Bae, Kim, Park, Han, Lee, Hyun, Kim, Kim, Cha, and Shin: Effectiveness of Implantable Cardioverter-Defibrillator Therapy for Heart Failure Patients according to Ischemic or Non-Ischemic Etiology in Korea

Abstract

Background and Objectives

This study was performed to describe clinical characteristics of patients with left ventriculars (LV) dysfunction and implantable cardioverter-defibrillator (ICD), and to evaluate the effect of ICD therapy on survival in Yeongnam province of Korea.

Subjects and Methods

From a community-based device registry (9 centers, Yeongnam province, from November 1999 to September 2012), 146 patients with LV dysfunction and an ICD implanted for primary or secondary prophylaxis, were analyzed. The patients were divided into two groups, based on the etiology (73 with ischemic cardiomyopathy and 73 with non-ischemic cardiomyopathy), and indication for the device implantation (36 for primary prevention and 110 for secondary prevention). The cumulative first shock rate, all cause death, and type and mode of death, were determined according to the etiology and indication.

Results

Over a mean follow-up of 3.5 years, the overall ICD shock rate was about 39.0%. ICD shock therapy was significantly more frequent in the secondary prevention group (46.4% vs. 16.7%, p=0.002). The cumulative probability of a first appropriate shock was higher in the secondary prevention group (p=0.015). There was no significant difference in the all-cause death, cardiac death, and mode of death between the groups according to the etiology and indication.

Conclusion

Studies from this multicenter regional registry data shows that in both ischemic and non-ischemic cardiomyopathy patients, the ICD shock therapy rate was higher in the secondary prevention group than primary prevention group.

Introduction

Implantable cardioverter-defibrillators (ICDs) are one of the established therapies for preventing sudden cardiac death in patients who are considered to be at a high risk for ventricular tachycardia (VT) or ventricular fibrillation (VF), or for those who are resuscitated from sustained VT/VF.1)2) Patients with left ventricular (LV) dysfunction due to ischemic or non-ischemic causes are at a risk for life threatening ventricular tachyarrhythmias, and a properly delivered shock from an ICD can improve their survival.3)4)5)6)7)8)9)10)11)12) Current guidelines for the implantation of ICDs have been supported by sufficient evidence from clinical trials on their beneficial effects on survival.1) However, to date, there are few data in the Korean population, about the efficacy of ICD therapy for preventing sudden death from sustained VT/VF due to ischemic or non-ischemic cardiomyopathy (CMP). Mainly Caucasians from Western societies have been the subjects of most clinical trials to prove the efficacy of ICDs in the prevention of sudden cardiac death. Some limitations would exist in extrapolating that data to Korean patients in the context of a different ethnic group. An ICD registry in this community would be a valuable resource that could provide important insight into the clinical and procedural characteristics of patients receiving ICDs in Korea, and further contribute to refine cardiovascular outcomes.13)
This study was done to evaluate the efficacy of ICD therapy in the Korean population of the Yeongnam province, according to the indication (primary prevention vs. secondary prevention) and underlying etiologies (non-ischemic CMP vs. ischemic CMP).

Subjects and Methods

From November 1999 to September 2012, a total of 287 patients enrolled in the registry database of 9 centers in Yeongnam province (Andong Medical Group, Daegu Catholic University Medical Center, Daegu Fatima Hospital, Inje University Busan Paik Hospital, Keimyung University Dongsan Medical Center, Kosin University Gospel Hospital, Kyungpook National University Hospital, Pusan National University Yangsan Hospital, and Yeungnam University Medical Center, in alphabetical order) were analyzed in this retrospective study. Patients classified as having hypertrophic CMP, arrhythmogenic right ventricular dysplasia/cardiomyopathy, genetic arrhythmic disorders (Brugada syndrome and long QT syndrome), or idiopathic VF were excluded. The selected patients (n=146) were divided into two groups, according to the following two criteria: 1) etiology: ischemic CMP (n=73) vs. non-ischemic CMP (n=73), and 2) indication for the device implantation: primary prevention (n=36) vs. secondary prevention (n=110, Fig. 1).
Ischemic CMP was traditionally considered to be present in patients with heart failure who had either a myocardial infarction (MI), evidence of a viable hibernating myocardium, or severe coronary disease on angiography, which might be regarded as the determining cause. Conversely, non-ischemic CMP was defined as heart failure not due to coronary arterial disease. The ICD for primary prevention were implanted when the following reimbursement criteria of the Korean Health Insurance Review & Assessment Service was met: patients with an LV ejection fraction (EF) less than 30%, or 30-35% with the induction of sustained VT/VF in the electrophysiologic study. ICD implantations for secondary prevention were those in which the device was implanted because they had a decreased LV systolic function and documented VT, or were resuscitated from sudden cardiac arrest due to witnessed or unwitnessed VT/VF.
All devices were implanted in the right or left subpectoral region, under local anesthesia. The manufacturers of the generators were Medtronic (Minneapolis, MN, USA), Guidant Corp. (Indianapolis, IN, USA), and St. Jude Medical (St. Paul, MN, USA). Each center attempted to tailor the shock therapy based on electrophysiologic studies, and an arrhythmic history of the patients, without any prior standardization.
After the device implantation, all ICD/CRT-D (cardiac resynchronization therapy with defibrillator devices) were regularly evaluated, and the follow-up data, including the intracardiac electrograms, were reviewed by experienced electrophysiologists at each center. The overall clinical outcomes were determined by comprehensively reviewing the medical records during routine outpatient visits or by telephone interviews during the follow-up period. The endpoints of this study comprised of all-cause deaths and shock therapy, whether it was appropriate or not. All-cause death was defined as the sum of the cardiac and non-cardiac deaths (death that was not primarily due to cardiac causes); after reviewing the medical records, cardiac death was further subclassified as sudden or non-sudden death. Appropriate shocks were defined as those that terminated VT/VF that would not spontaneously terminate or could not be terminated by anti-tachycardia pacing (ATP). Inappropriate shocks included the traditionally classified shocks rendered in unnecessary situations: shocks delivered for supraventricular tachycardia (SVT) (such as atrial fibrillation [AF] with a rapid ventricular response, or oversensing), those delivered for ventricular tachyarrhythmias (monomorphic or polymorphic) that would otherwise have spontaneously terminated without delivery of any therapy, VTs that would terminate with ATP, or VT that was too slow to require therapy. We also included tachyarrhythmia caused by lead problem.12)

Statistical analysis

The results are reported as the mean±standard deviation for numerical variables, and as frequencies and percentages for categorical variables. The independent t-test was used to compare group continuous variables and the Chi-square test or Fisher's exact test was used to compare the categorical variables between groups. Incidences of all-cause death and the frequency of shock therapies (including appropriate and inappropriate shocks) in each group were determined using Kaplan-Meier event curves, and compared using log-rank tests. A multivariate logistic regression analysis was used to identify the predictors of all-cause death in the total study population. SPSS version 18.0 for Windows (SPSS Inc., Chicago, IL, USA) was used for the statistical analyses, and statistical significance was accepted for p value<0.05.

Results

Baseline characteristics

A total of 146 patients were evaluated. The mean age and mean LVEF were 63 years old and 30%, respectively, with an average follow up of 3.5 years (range, 9 months to 170 months). The patients were classified into two groups, based on the etiology and device indication. A comparison of the clinical characteristics between ischemic CMP and non-ischemic CMP, and a comparison between the primary prevention group and secondary prevention group, are summarized in Table 1 and 2, respectively.

Ischemic CMP vs. non-ischemic CMP

More male patients (56 males vs. 43 females, p=0.021) as well as more patients who had a history of a previous MI (45 patients vs. 8 patients, p<0.001) were present in the ischemic CMP group. Also, the average age was higher in the ischemic CMP group (65.6 years vs. 60.2 years, p=0.028). Patients who had experienced previous heart failure (HF) were more frequently observed in the non-ischemic CMP group (60 patients vs. 46 patients, p=0.009). The proportion of ICD implantations was higher in the ischemic CMP group, whereas the proportion of CRT-D implantations was higher in the non-ischemic CMP group (94.5% vs. 74.0%, and 26.0% vs. 5.5%, p=0.001 for all, Table 1).

Primary prevention vs. secondary prevention

Patients with underlying HF were more common in the primary prevention group (94.4% vs. 65.5%, p<0.001). The LV end-diastolic and end-systolic measurements in the primary prevention group were greater, and the LVEF was significantly lower, compared to that in the secondary prevention group (Table 2). The proportion of ICD implantations was higher in the secondary prevention group than the primary prevention group, whereas the proportion of CRT-D implantations was higher in the primary prevention group (93.6% vs. 55.6%, and 44.4% vs. 6.4%, p<0.001 for all, Table 2).

Clinical outcomes

Shock deliveries

The overall ICD shock rate (not including ATP) was about 39.0%, regardless of the underlying etiology. No difference was observed in the appropriate shock rate between the ischemic- and non-ischemic CMP (27.4% vs. 28.7%, p=NS, Table 3). Appropriate shock therapies tended to be more frequently delivered in the secondary prevention group (31.8% vs. 13.9%, p=NS, Table 4). ICD shock therapies were significantly more frequent in the secondary prevention group (46.4% vs. 16.7%, p=0.002, Table 4), and the cumulative probability of a first appropriate shock therapy was significantly higher in the secondary prevention group (log rank p=0.015, Fig. 2). During the first year after the ICD implantation, a higher rate of the first appropriate shock therapy was delivered (Fig. 3). There was no significant difference in the mortality rate, cause of death, or mode of death between the two groups (Table 3, 4). When classified according to the device category (ICD group vs. CRT-D group), shock therapies were observed in half the patients in whom an ICD was implanted (45.5 % vs. 4.3 %, p<0.001, Table 5) and only one patient with a CRT-D experienced an inappropriate shock therapy.

Inappropriate shocks

Inappropriate shock therapy rate was insignificantly higher in the ischemic CMP group than non-ischemic CMP group (15.1% vs. 6.9%, p=NS, Table 3), and higher in the secondary prevention group than primary prevention group (14.5% vs. 2.8%, p=NS, Table 4, Supplementary Fig. 1 in the online-only Data Supplement.). In the 146 subjects evaluated, regardless of the etiology and indication, the link between inappropriate shocks and death was explored. Although the death rate was higher in patients who had inappropriate shocks, there was no significant difference between them (34.1% vs. 18.8%, p=NS, Fig. 4 and Supplementary Fig. 2 in the online-only Data Supplement.).

Mortality

The all-cause mortality was 24.7% during the mean follow-up period; 15.8% were due to cardiac causes and 8.9% due to non-cardiac causes. There were no significant differences in the all-cause death, cardiac death, or mode of death between the groups, according to the etiology and indication (Table 3, 4). In the Kaplan-Meier survival probability estimates based on the survival curves, there was no difference in the total cumulative survival rate between the groups (primary prevention vs. secondary prevention, ischemic CMP vs. non-ischemic CMP, appropriate shock vs. inappropriate shock, ICD vs. CRT-D, presence of shock therapy vs. no shock therapy; Fig. 4 and Supplementary Fig. 3, 4 in the online-only Data Supplement). In a univariate analysis for predicting the all-cause mortality in these patients, gender female, a lower body mass index (BMI), and history of a previous hospitalization were significant prognostic factors. In a multivariate logistic regression model, a lower BMI (≤25 kg/m2) and history of a previous hospitalization were independent prognostic factors of death (Table 6).

Discussion

In the community-based device registry of the Yeongnam province of Korea, ICDs and CRT-Ds were more frequently implanted for secondary prevention than primary prevention. The main findings of this study were: 1) the overall ICD shock rate during 3.5 years of follow-up period was about 39.0%, including 11.6% that were inappropriate shocks, 2) appropriate shock therapies were more frequently delivered in the secondary prevention group; the cumulative first appropriate shock rate in the secondary prevention and primary prevention groups was 31.8% and 13.9%, respectively, both of which seemed to be lower than that in the previous ICD clinical trials based on Western populations, 3) no significant differences in the appropriate shock rate between ischemic- and non-ischemic CMP were found.
In the evaluation of whether the current ICD guideline for primary prophylaxis against sudden cardiac death are appropriate for the Korean population with severe HF, it was concluded that the primary prevention criteria for ICD implantations would also be appropriate in both the ischemic- and non-ischemic CMP patients, since Korean patients with severe HF in both the ischemic- and non-ischemic-CMP groups had an all-cause mortality and risk of sudden cardiac death comparable to the patients in the Multicenter Automatic Defibrillator Implantation Trial-II (MADIT-II) and Defibrillators in Non-Ischemic Cardiomyopathy Treatment Evaluation (DEFINITE) standard therapy groups.14)
Few studies on the efficacy of ICDs in Korean patients have been conducted. Recently published data from a single center in Korea reported that the ICD shock rate during 3 years of follow-up was 42.6%; however, in that study the subjects were heterogeneously composed of various cardiomyopathic diseases and genetic arrhythmia syndromes.15)

The rate of shock therapies during the follow-up period

During the 3.5 years of follow-up, the overall ICD shock rate in this study was about 39.0%, regardless of the underlying etiology. In case of secondary prevention, shocks were delivered to almost half of the study subjects (46.4%), which was in contrast to the 16.7% in the primary prevention group. In the 3-year representative ICD trial for secondary prevention, i.e. the Antiarrhythmics vs. Implantable Defibrillators trial, the cumulative percentage of patients with any activation of the defibrillator, either antitachycardia pacing or shocks, was 85% in patients with VT and 69% in patients with VF.4) Further, in the 4-year Canadian implantable defibrillator study (CIDS), the cumulative risk of receiving an ICD shock was 65.4%.6) With regards to the ICD firing rate in the primary prevention trials, 60% of the patients with an ICD had a shock discharge within 2 years after enrollment in the first Multicenter Automatic Defibrillator Implantation Trial,3) with the shock rate reaching 36% at 3 years in the second MADIT-II.8) The actuarial incidence of a first shock from the ICD was 50% at 1 year and 57% at 2 years in the Prophylactic use of ICDs in patients at high risk for ventricular arrhythmias after Coronary-artery bypass graft surgery trial (CABG Patch).5) The shock rate was 39.3% (including a 17.9% appropriate shock rate) in the DEFINITE trial, in which the follow-up lasted 29 months.9) Conversely, 31% of the ICD group received shocks for any cause (including 21% with appropriate ICD shock therapies, and ATP was not used) in the Sudden Cardiac Death in Heart Failure Trial (SCD-HeFT), and this cumulative shock rate occurred over a mean of 45.5 months.10)
Taken together, in comparison with the previous trials,3)8)9) the overall shock rate in our study was considerably lower even with a longer follow-up period. Thus, extrapolating these findings of patients residing in the Yeongnam province of Korea, we can cautiously assess that all Korean patients might have a lower incidence when compared with the patients of Western countries, in the same disease category.
Furthermore, patients with a CRT-D device had a lower shock rate compared to that of the patients with ICDs in our study. The reason is unclear, but we speculate that it was driven by improving the LV function by the negative LV remodeling effect of the CRT.16)

The issue of inappropriate shocks

In our study, the inappropriate shock therapy rate was numerically higher in the ischemic CMP group and the secondary prevention group. The rate of inappropriate shock therapies also seemed to be lower than that of the previous trials of Western populations.11)12)17)18)19)20)21)22) Regardless of the etiology and indication, our study patients undergoing inappropriate shocks had a numerically but insignificantly higher death rate than those who did not. However, the MADIT-II trial results had revealed that prior occurrences of inappropriate shocks doubled the risk of total mortality.11) This can be explained by a potential direct mechanical, arrhythmogenic effect of the shock itself, and the presence of AF, which is the cause of both inappropriate shocks and an increased risk of mortality. We speculated that this difference arose due to the small number of our patient population.

Mortality

During the follow-up period, the all-cause mortality was 24.7%, which included 15.8% due to cardiac causes and 8.9% due to non-cardiac causes. In comparison, in a representative secondary prevention trial over a mean follow-up of 18 months, the crude death rates were 15.8% in the ICD group, and 24.0% in the antiarrhythmic-drug group.4) The mortality rate of the ICD group in the primary prevention trials varied: 7.9% over 29 months in the DEFINITE trial,9) and 15.7% and 14.2% in the first and second MADIT trials, respectively.3)8) In the SCD-HeFT,10) the mortality rate in the ICD group was 22%. In short, the mortality rate of our current study seemed to be similar to or higher than that reported in the ICD group in the previous trials due to inexplicable reasons.

Limitations

Although this study gave us a fascinating glimpse into the activation or efficacy of ICDs implanted in Korean HF patients for primary and secondary prevention, we are as yet unaware of the actual efficacy or life-saving effects of an ICD therapy due to the following reasons: First, the number of patients enrolled was quite small and lacked a control group. Second, device programming settings for the VT/VF therapy were not standardized in each center, and therefore the shock therapy might not have been delivered in the same ICD therapy zone. As shown in the MADIT-RIT (Multicenter Automatic Defibrillator Implantation Trial–Reduce Inappropriate Therapy trial) and PainFree SST (SmartShock Technology) trial, which demonstrated a reduction in the inappropriate and appropriate ICD therapies and mortality according to the ICD programming and the adoption of novel enhanced detection algorithms,18)22) the frequency of ICD therapy varied depending on the ICD programming. Third, we need to know that a shock therapy is a surrogate marker of a lifesaving effect, and not all appropriate and successful shocks are life-saving. Finally, we could not provide any information on the concomitant medications, especially the beta blockers used, and information about the presence of AF, other SVTs, and/or abnormal sensing as a cause of inappropriate shocks.
Though it is quite difficult to draw a firm conclusion because of the various reasons mentioned above, this study gives us a fascinating glimpse into the activation or efficacy of ICDs implanted in the Korean population for both primary and secondary prevention.
In conclusion, in this In this multicenter regional registry data, most cases of ICD implantations were performed for secondary prevention. The ICD shock therapy rate was higher in the secondary prevention group than in primary prevention group, in both ischemic and non-ischemic CMP patients. Both the appropriate and inappropriate shock rates seemed to be lower than that of the prior trials based on Western populations. However, additional randomized prospective trials in a large population are needed to determine the true efficacy of ICD therapy in Korean patients with LV dysfunction.

Figures and Tables

Fig. 1

Study flow chart. 1Left ventricular ejection fraction <30% or 30-35% with sustained ventricular tachycardia and/or ventricular fibrillation on electrophysiologic study, 2Patients who were resuscitated from sudden cardiac death with decreased left ventricular systolic function.

kcj-47-72-g001
Fig. 2

Cumulative probability of the first appropriate implantable defibrillator therapy. (A) shows the shock therapy delivered in all patients, and (B) shows comparison of the shock therapy according to the indication in patients that underwent a device implantation (log rank p=0.015).

kcj-47-72-g002
Fig. 3

Time-dependence of the first appropriate implantable defibrillator therapy. “Patients entering” refers to the number of patients without appropriate implantable defibrillator therapies for ventricular tachyarrhythmia being followed at the beginning of each time interval. ICD: implantable cardioverter/defibrillator.

kcj-47-72-g003
Fig. 4

Comparison of cumulative survival rate according to the indication, the etiology, and the type of shock therapy by Kaplan-Meier plots. (A) shows total cumulative survival rate in all patients. (B) shows cumulative survival rate according to the indication in patients that underwent a device implantation (p=0.626). (C) shows cumulative survival rate according to the etiology in patients who underwent a device implantation (p=0.316). (D) shows cumulative survival rate according to the type of shock therapy in patients who underwent a device implantation (p=0.816). CMP: cardiomyopathy.

kcj-47-72-g004
Table 1

Baseline clinical characteristics of the study patients categorized by the etiology

kcj-47-72-i001
Total (n=146) Non-ischemic CMP (n=73) Ischemic CMP (n=73) p
Patients
 Male 43 (58.9) 56 (76.7) 0.021
 Age (years) 60.18±14.03 65.60±15.41 0.028
 BMI (kg/m2) 22.98±3.32 23.89±2.90 0.291
Clinical history
 Diabetes mellitus 18 (30.0) 14 (26.4) 0.673
 Hypertension 16 (21.9) 18 (24.7) 0.695
 Previous MI 8 (11.0) 45 (61.6) <0.001
 Previous HF 60 (82.2) 46 (63.0) 0.009
 Family history of sudden death 3 (4.1) 1 (1.4) 0.311
Previous history of cardiac arrest 0.460
 No arrest 56 (76.7) 57 (78.1)
 Tachy-arrest 4 (5.5) 7 (9.6)
 Brady-arrest 13 (17.8) 9 (12.3)
Echocardiographic findings
 LVESD (mm) 54.38±13.22 52.29±12.26 0.325
 LVEDD (mm) 64.56±11.17 62.17±10.61 0.188
 LVEF (%) 28.67±13.01 31.62±12.41 0.165
Indication for device implantation 0.125
 Primary prevention 22 (30.1) 14 (19.2)
 Secondary prevention 51 (69.9) 59 (80.8)
Type of implanted device 0.001
 ICD 54 (74.0) 69 (94.5)
 CRT-D 19 (26.0) 4 (5.5)
Generator 0.006
 Single chamber 33 (45.2) 46 (63.0)
 Dual chamber 23 (31.5) 24 (31.5)
 Biventricular 17 (23.3) 6 (5.5)
Manufacturer 0.010
 Medtronic® 39 (53.4) 26 (35.6)
 St. Jude® 29 (39.7) 46 (63.0)
 Guidant® 5 (6.8) 1 (1.4)

Data are expressed as mean±standard deviation or number (%). CMP: cardiomyopathy, BMI: body mass index, MI: myocardial infarction, HF: heart failure, Tachy-arrest: cardiac arrest by tachyarrhythmia, Brady-arrest: cardiac arrest by bradyarrhythmia, LVESD: left ventricular end-systolic dimension, LVEDD: left ventricular end-diastolic dimension, LVEF: left ventricular election fraction, ICD: implantable cardioverter/defibrillator, CRT-D: cardiac resynchronization therapy with defibrillator

Table 2

Baseline clinical characteristics of the study patients categorized by the indication for the device implantation

kcj-47-72-i002
Total (n=146) Primary prevention (n=36) Secondary prevention (n=110) p
Patients
 Male 24 (66.7) 75 (68.2) 0.866
 Age (years) 60.33±11.64 63.73±15.83
 BMI (kg/m2) 23.60±3.33 23.38±3.10 0.719
Clinical history
 Diabetes mellitus 9 (27.3) 23 (28.8) 0.874
 Hypertension 9 (25.0) 25 (22.7) 0.779
 Previous MI 16 (44.4) 37 (33.6) 0.242
 Previous HF 34 (94.4) 72 (65.5) <0.001
 Family history of sudden death 0 (0.0) 4 (3.6) 0.246
Previous cardiac arrest 0.004
 No arrest 35 (97.2) 78 (70.9)
 Tachy-arrest 1 (2.8) 10 (9.1)
 Brady-arrest 0 (0.0) 22 (20.0)
Echocardiographic findings
 LVESD (mm) 59.35±13.56 51.35±11.88 0.001
 LVEDD (mm) 67.96±10.20 61.86±10.78 0.003
 LVEF (%) 22.97±9.96 32.50±12.74 <0.001
Cardiac diagnosis 0.125
 Non-ischemic CMP 22 (61.1) 51 (46.4)
 Ischemic CMP 14 (38.9) 59 (53.6)
Type of implanted device <0.001
 ICD 20 (55.6) 103 (93.6)
 CRT-D 16 (44.4) 7 (6.4)
Generator <0.001
 Single chamber 11 (30.6) 68 (61.8)
 Dual chamber 8 (22.2) 38 (34.5)
 Biventricular 17 (47.2) 4 (3.6)
Manufacturer 0.327
 Medtronic® 16 (44.4) 49 (44.5)
 St. Jude® 17 (47.2) 58 (52.7)
 Guidant® 3 (8.3) 3 (2.7)

Data are expressed as mean±standard deviation or number (%). BMI: body mass index, MI: myocardial infarction, HF: heart failure, Tachy-arrest: cardiac arrest by tachyarrhythmia, Brady-arrest: cardiac arrest by bradyarrhythmia, LVEDD: left ventricular end-diastolic dimension, LVESD: left ventricular end-systolic dimension, LVEF: left ventricular election fraction, ICD: implantable cardioverter/defibrillator, CRT-D: cardiac resynchronization therapy with defibrillator

Table 3

Rate of shock therapies and the clinical outcomes in the patients according to the etiology

kcj-47-72-i003
Total (n=146) Non-ischemic CMP (n=73) Ischemic CMP (n=73) p
Shock therapy 0.365
 Yes 26 (35.6) 31 (42.5) 0.320
  Appropriate shock 21 (28.7) 20 (27.4) 0.174
  Inappropriate shock 5 (6.9) 11 (15.1)
 No 46 (63.0) 39 (53.4)
 ATP 1 (1.4) 3 (4.1)
Duration, first shock after the device implantation (days) 194.67±214.05 416.00±545.92 0.052
Hospitalization 30 (41.1) 36 (49.3) 0.318
Death 20 (27.4) 16 (21.9) 0.442
 Cause of death 0.587
  Cardiac 12 (16.4) 11 (15.1)
  Non-cardiac 8 (11.0) 5 (6.8)
 Mode of death 0.694
  Sudden 3 (4.1) 1 (1.3)
  Non-sudden 9 (12.3) 10 (13.7)

Data are expressed as mean±standard deviation or number (%). CMP: cardiomyopathy, ATP: anti-tachycardia pacing

Table 4

Rate of shock therapies and the clinical outcomes in the patients according to the indication for the device implantation

kcj-47-72-i004
Total (n=146) Primary prevention (n=36) Secondary prevention (n=110) p
Shock therapy 0.006
 Yes 6 (16.7) 51 (46.4) 0.002
  Appropriate shock 5 (13.9) 35 (31.8) 0.456
  Inappropriate shock 1 (2.8) 16 (14.5)
 No 29 (80.6) 56 (50.9)
 ATP 1 (2.8) 3(2.7)
Duration, first shock after device implantation (days) 422.33±351.16 302.17±450.81 0.533
Hospitalization 11 (30.6) 55 (50.0) 0.042
Death 10 (27.8) 26 (23.6) 0.617
 Cause of death 0.763
  Cardiac 6 (16.7) 17 (15.5)
  Non-cardiac 4 (11.1) 9 (8.2)
 Mode of death 0.491
  Sudden 1 (2.8) 5 (4.5)
  Non-sudden 5 (13.9) 12 (10.9)

Data are expressed as mean±standard deviation or number (%). ATP: anti-tachycardia pacing

Table 5

Comparison of the shock therapy according to the device category

kcj-47-72-i005
ICD (n=123) CRT–D (n=23) p
Shock therapy <0.001
 Yes 56 (45.5) 1 (4.3) <0.001
  Appropriate shock 41 (33.3) 0 (0.0) 0.106
  Inappropriate shock 15 (12.2) 1 (4.3)
 No 63 (51.2) 22 (95.7)
 ATP 4 (3.3) 0 (0.0)

Data are expressed as mean±standard deviation or number (%). ICD: implantable cardioverter/defibrillator, CRT-D: cardiac resynchronization therapy with defibrillator, ATP: anti-tachycardia pacing

Table 6

Variables associated with all-cause death

kcj-47-72-i006
Variables Multivariate analysis Multivariate analysis
HR 95% CI p HR 95% CI p
Age (>65 years) 1.948 0.882–4.084 0.101
Gender (female) 2.655 1.217–5.795 0.014
Diabetes 0.718 0.240–2.150 0.553
Hypertension 1.024 0.413–2.540 0.959
BMI (≤25 kg/m2) 3.465 1.244–9.653 0.017 15.427 1.874–126.993 0.011
EF (<30%) 0.667 0.302–1.474 0.317
LVEDD (>65 mm) 2.031 0.944–4.371 0.070
Shock therapy 1.476 0.688–3.167 0.317
Secondary prevention 0.802 0.341–1.889 0.614
Ischemic CMP 0.770 0.360–1.647 0.501
Hospitalization 2.214 1.022–4.799 0.044 4.970 1.543–16.006 0.007

HR: hazard ratio, CI: confidence interval, BMI: Body mass index, EF: ejection fraction, LVEDD: left ventricular end-diastolic dimension, CMP: cardiomyopathy

Notes

The authors have no financial conflicts of interest.

References

1. Epstein AE, DiMarco JP, Ellenbogen KA, et al. 2012 ACCF/AHA/HRS focused update incorporated into the ACCF/AHA/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities: a report of the American College of Cardiology Foundation/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society. J Am Coll Cardiol. 2013; 61:e6–e75.
2. Mann DL, Zipes DP, Libby P, Bonow RO, Braunwald E. Braunwald's heart disease: a textbook of cardiovascular medicine. 10th ed. Philadelphia: Elsevier Saunders;2015. p. 724–725.
3. Moss AJ, Hall WJ, Cannom DS, et al. Improved survival with an implanted defibrillator in patients with coronary disease at high risk for ventricular arrhythmia. Multicenter automatic defibrillator implantation trial investigators. N Engl J Med. 1996; 335:1933–1940.
4. The Antiarrhythmics versus Implantable Defibrillators (AVID) Investigators. A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias. N Engl J Med. 1997; 337:1576–1583.
5. Bigger JT Jr. Coronary Artery Bypass Graft (CABG) Patch Trial Investigators. Prophylactic use of implanted cardiac defibrillators in patients at high risk for ventricular arrhythmias after coronary-artery bypass graft surgery. N Engl J Med. 1997; 337:1569–1575.
6. Connolly SJ, Gent M, Roberts RS, et al. Canadian implantable defibrillator study (CIDS): a randomized trial of the implantable cardioverter defibrillator against amiodarone. Circulation. 2000; 101:1297–1302.
7. Bänsch D, Antz M, Boczor S, et al. Primary prevention of sudden cardiac death in idiopathic dilated cardiomyopathy: the Cardiomyopathy Trial (CAT). Circulation. 2002; 105:1453–1458.
8. Moss AJ, Zareba W, Hall WJ, et al. Prophylactic implantation of a defibrillator in patients with myocardial infarction and reduced ejection fraction. N Engl J Med. 2002; 346:877–883.
9. Kadish A, Dyer A, Daubert JP, et al. Prophylactic defibrillator implantation in patients with nonischemic dilated cardiomyopathy. N Engl J Med. 2004; 350:2151–2158.
10. Bardy GH, Lee KL, Mark DB, et al. Amiodarone or an implantable cardioverter-defibrillator for congestive heart failure. N Engl J Med. 2005; 352:225–237.
11. Daubert JP, Zareba W, Cannom DS, et al. Inappropriate implantable cardioverter-defibrillator shocks in MADIT II: frequency, mechanisms, predictors, and survival impact. J Am Coll Cardiol. 2008; 51:1357–1365.
12. Koneru JN, Swerdlow CD, Wood MA, Ellenbogen KA. Minimizing inappropriate or “unnecessary” implantable cardioverter-defibrillator shocks: appropriate programming. Circ Arrhythm Electrophysiol. 2011; 4:778–790.
13. Lee SW, Kim HC, Lee HS, Suh I. Thirty-year trends in mortality from cardiovascular diseases in Korea. Korean Circ J. 2015; 45:202–209.
14. Kim J, Choi EK, Lee MH, et al. The relevance of the primary prevention criteria for implantable cardioverter defibrillator implantation in korean symptomatic severe heart failure patients. Korean Circ J. 2012; 42:173–183.
15. Yang JH, Byeon K, Yim HR, et al. Predictors and clinical impact of inappropriate implantable cardioverter-defibrillator shocks in Korean patients. J Korean Med Sci. 2012; 27:619–624.
16. Kutyifa V, Daubert JP, Schuger C, et al. Novel ICD programming and inappropriate ICD therapy in CRT-D versus ICD patients: a MADIT-RIT sub-study. Circ Arrhythm Electrophysiol. 2016; 9:e001965.
17. Verma A, Sarak B, Kaplan AJ, et al. Predictors of appropriate implantable cardioverter defibrillator (ICD) therapy in primary prevention patients with ischemic and nonischemic cardiomyopathy. Pacing Clin Electrophysiol. 2010; 33:320–329.
18. Moss AJ, Schuger C, Beck CA, et al. Reduction in inappropriate therapy and mortality through ICD programming. N Engl J Med. 2012; 367:2275–2283.
19. Gracieux J, Sanders GD, Pokorney SD, Lopes RD, Thomas K, Al-Khatib SM. Incidence and predictors of appropriate therapies delivered by the implantable cardioverter defibrillator in patients with ischemic cardiomyopathy: a systematic review. Int J Cardiol. 2014; 177:990–994.
20. Klein RC, Raitt MH, Wilkoff BL, et al. Analysis of implantable cardioverter defibrillator therapy in the Antiarrhythmics Versus Implantable Defibrillators (AVID) trial. J Cardiovasc Electrophysiol. 2003; 14:940–948.
21. Sedlacek K, Ruwald AC, Kutyifa V, et al. The effect of ICD programming on inappropriate and appropriate ICD Therapies in ischemic and nonischemic cardiomyopathy: the MADIT-RIT trial. J Cardiovasc Electrophysiol. 2015; 26:424–433.
22. Auricchio A, Schloss EJ, Kurita T, et al. Low inappropriate shock rates in patients with single-and dual/triple-chamber implantable cardioverter-defibrillators using a novel suite of detection algorithms: PainFree SST trial primary results. Heart Rhythm. 2015; 12:926–936.

Supplementary Materials

The online-only Data Supplements are available with article at https://doi.org/10.4070/kcj.2016.0242.

Supplementary Fig. 1

Comparison of ICD shock therapy based on the etiology and the indication. (A) shows incidence of the shock therapy depending on the etiology of heart failure and (B) shows incidence of the shock therapy depending on the indication for device implantation. ICD: implantable cardioverter-defibrillator, NS: not statistically significant.

Supplementary Fig. 2

All-cause mortality in patients with a device implantation due to left ventricular dysfunction depending on the presence of inappropriate shocks (p=0.254). NS: not statistically significant.

Supplementary Fig. 3

Cumulative survival rate according to device category in the patients who underwent a device implantation (p=0.510).

Supplementary Fig. 4

Cumulative survival rate according to the presence of shock therapy (p=0.476).