Abstract
Background and Objectives
Dobutamine stress echocardiography (DSE) with 2D echocardiography (2DE) is one of the time-consuming procedures in the diagnosis of coronary artery disease (CAD). Moreover, the accuracy of DSE with 2DE depends on the operator's skill or bias during the image acquisition. This study was conducted to determine the feasibility and accuracy of DSE with real-time 3D echocardiography (RT3DE) for the diagnosis of CAD.
Subjects and Methods
62 patients (RT3DE: 36, 2DE: 26), suspected of angina pectoris and post-revascularization ischemia, underwent DSE and coronary angiography (CAG). Image acquisition was performed at the baseline, and at 4 times during the dobutamine infusion and recovery stages. The procedure time (from the baseline to the end of the peak dose stage) was recorded. Off-line analyses of the volumetric images acquired with RT3DE were performed using 3D computer software (TomTec, Co.). Digitized quad-screen images acquired with 2DE were analyzed using the 2DE review system (ProSolv 4.0). >50% luminal diameter stenosis of any coronary artery on CAG was defined as significant coronary artery stenosis.