Journal List > J Korean Orthop Assoc > v.48(3) > 1013224

Lee, Baek, and Kim: Early Results of Cementless Total Hip Arthroplasty Using a Third Generation Alumina-on-Alumina Bearing Surface

Abstract

Purpose

The purpose of this study is to evaluate the early results and occurrence of complications of cementless total hip arthroplasty (THA) using an alumina-on-alumina articulation with a minimum follow up period of three years.

Materials and Methods

We prospectively followed 108 patients (121 hips) who underwent cementless THA using an alumina-on-alumina articulation. The mean age of the patients was 50.7 years (range, 20-80 years) and mean the follow up period was 48 months (range, 36-60 months). Preoperative diagnoses included osteonecrosis of the femoral head in 90 hips; secondary osteoarthritis due to hip dysplasia in 24 hips; secondary osteoarthritis after acetabular fracture in four hips; acute femoral neck fracture in three hips. Clinical evaluation was performed using Harris hip score (HHS) and radiographic evaluation was performed in terms of the fixation of components and the prevalence of osteolysis. In addition, we observed complications, including the occurrence of sound or fracture of the alumina head or liner.

Results

Mean HHS improved from 62.4 points to 94 points at final follow-up. Thigh discomfort was found in six hips and mild inguinal discomfort was found in eight hips. Both had disappeared within one year after operation. A clicking sound was detected in two patients. One hip had become dislocated and an alumina liner fracture had occurred in one hip. Loosening of component or osteolysis was not observed in any hip. The radiographic wear was not measurable.

Conclusion

Early results of cementless THA using an alumina-on-alumina articulation were favorable, with osseointegration of the components and absence of periprosthetic osteolysis. However, longer-term follow up for a hip clicking sound and fracture of an alumina fracture are necessary.

Figures and Tables

Figure 1
Photograph showing the COREN Hip System® with alumina-on-alumina bearing.
jkoa-48-190-g001
Figure 2
Anteroposterior radiographs showing the right hip of a 61-year-old female who underwent a total hip arthroplasty. (A) The preoperative findings of the secondary osteoarthritis due to hip dysplasia. (B) Postoperative 1-year follow-up radiograph. (C) Radiograph taken 48 months after total hip arthroplasty. Patient complained intermittent clicking of hip joint, but radiograph shows well fixed components without loosening.
jkoa-48-190-g002
Figure 3
Anteroposterior radiographs showing the right hip of a 51-year-old female who underwent a total hip arthroplasty. (A) The preoperative findings of hip dysplasia. (B) Postoperative 4-year follow-up radiogarph of fractured ceramic bearings. (C) Radiograph taken 2 months after head and liner change.
jkoa-48-190-g003
Figure 4
Photograph of the fractured alumina bearings. Photograph shows a fractured alumina liner (black arrows) and black discoloration of the alumina head (white arrow) that was retrieved form a 51-year-old female patient at 51 months postoperatively.
jkoa-48-190-g004

References

1. Older J. Charnley low-friction arthroplasty: a worldwide retrospective review at 15 to 20 years. J Arthroplasty. 2002; 17:675–680.
2. Sedel L. Ceramic hips. J Bone Joint Surg Br. 1992; 74:331–332.
crossref
3. Boutin P, Blanquaert D. A study of the mechanical properties of alumina-on-alumina total hip prosthesis (author's transl). Rev Chir Orthop Reparatrice Appar Mot. 1981; 67:279–287.
4. Mahoney OM, Dimon JH 3rd. Unsatisfactory results with a ceramic total hip prosthesis. J Bone Joint Surg Am. 1990; 72:663–671.
crossref
5. Skinner HB. Ceramic bearing surfaces. Clin Orthop Relat Res. 1999; 369:83–91.
crossref
6. Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fractures: treatment by mold arthroplasty. An end-result study using a new method of result evaluation. J Bone Joint Surg Am. 1969; 51:737–755.
7. Bands R, Pelker RR, Shine J, Bradburn H, Margolis R, Leach J. The noncemented porous-coated hip prosthesis. A three-year clinical follow-up study and roentgenographic analysis. Clin Orthop Relat Res. 1991; 269:209–219.
8. Swanson TV, Peterson DJ, Seethala R, Bliss RL, Spellmon CA. Influence of prosthetic design on squeaking after ceramic-on-ceramic total hip arthroplasty. J Arthroplasty. 2010; 25:6 Suppl. 36–42.
crossref
9. Hodgkinson JP, Shelley P, Wroblewski BM. The correlation between the roentgenographic appearance and operative findings at the bone-cement junction of the socket in Charnley low friction arthroplasties. Clin Orthop Relat Res. 1988; 228:105–109.
crossref
10. DeLee JG, Charnley J. Radiological demarcation of cemented sockets in total hip replacement. Clin Orthop Relat Res. 1976; 121:20–32.
crossref
11. Gruen TA, McNeice GM, Amstutz HC. "Modes of failure" of cemented stem-type femoral components: a radiographic analysis of loosening. Clin Orthop Relat Res. 1979; 141:17–27.
12. Engh CA, Massin P, Suthers KE. Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res. 1990; 257:107–128.
crossref
13. Callaghan JJ, Dysart SH, Savory CG. The uncemented porous-coated anatomic total hip prosthesis. Two-year results of a prospective consecutive series. J Bone Joint Surg Am. 1988; 70:337–346.
crossref
14. Rothman RH, Hozack WJ, Ranawat A, Moriarty L. Hydroxyapatite-coated femoral stems. A matched-pair analysis of coated and uncoated implants. J Bone Joint Surg Am. 1996; 78:319–324.
crossref
15. Brooker AF, Bowerman JW, Robinson RA, Riley LH Jr. Ectopic ossification following total hip replacement. Incidence and a method of classification. J Bone Joint Surg Am. 1973; 55:1629–1632.
16. Muratoglu OK, Bragdon CR, O'Connor DO, Jasty M, Harris WH. A novel method of cross-linking ultra-high-molecular-weight polyethylene to improve wear, reduce oxidation, and retain mechanical properties. Recipient of the 1999 HAP Paul Award. J Arthroplasty. 2001; 16:149–160.
17. Boutin P, Christel P, Dorlot JM, et al. The use of dense alumina-alumina ceramic combination in total hip replacement. J Biomed Mater Res. 1988; 22:1203–1232.
crossref
18. Kim SY, Kyung HS, Ihn JC, Cho MR, Koo KH, Kim CY. Cementless Metasul metal-on-metal total hip arthroplasty in patients less than fifty years old. J Bone Joint Surg Am. 2004; 86:2475–2481.
crossref
19. Langkamer VG, Case CP, Collins C, et al. Tumors around implants. J Arthroplasty. 1997; 12:812–818.
crossref
20. Archibeck MJ, Jacobs JJ, Black J. Alternate bearing surfaces in total joint arthroplasty: biologic considerations. Clin Orthop Relat Res. 2000; 379:12–21.
21. Hasegawa M, Sudo A, Hirata H, Uchida A. Ceramic acetabular liner fracture in total hip arthroplasty with a ceramic sandwich cup. J Arthroplasty. 2003; 18:658–661.
crossref
22. Willmann G. Ceramic femoral head retrieval data. Clin Orthop Relat Res. 2000; 379:22–28.
crossref
23. Heros RJ, Willmann G. Ceramics in total hip arthroplasty: history, mechanical properties, clinical results, and current manufacturing state of the art. Semin Arthroplasty. 1998; 9:114–122.
24. Yoo JJ, Kim YM, Yoon KS, et al. Alumina-on-alumina THA in active patients younger than 40 years old: a 5-year minimum follow-up study. J Korean Orthop Assoc. 2006; 41:404–412.
25. Bergman NR, Young DA. The rationale, short-term outcome and early complications of a ceramic couple in total hip arthroplasty. In : Sedel L, Willmann G, editors. Reliability and long-term results of ceramics in orthopedics. Stuttgart: Georg Thieme Verlag;1999. p. 52–56.
26. Fuchs GA. Willmann G, Zweymüller K, editors. 2-4 year clinical results with a ceramic-on-ceramic articulation in a new modular THR-system. Bioceramics in hip joint replacement: proceedings 5th International CeramTec Symposium. 2000. Febr. 18/19, 2000; Stuttgart, New York: Thieme;p. 39–46.
27. Chevillotte C, Trousdale RT, Chen Q, Guyen O, An KN. The 2009 Frank Stinchfield Award: "Hip squeaking": a biomechanical study of ceramic-on-ceramic bearing surfaces. Clin Orthop Relat Res. 2010; 468:345–350.
28. Walter WL, Waters TS, Gillies M, et al. Squeaking hips. J Bone Joint Surg Am. 2008; 90:Suppl 4. 102–111.
crossref
29. Park YS, Kim YS, Lee JM, Sun DH, Moon YW, Lim SJ. Cementless total hip arthroplasty with use of the COREN hip system. J Korean Hip Soc. 2007; 19:457–462.
crossref
30. Baek SH, Kim SY. Cementless total hip arthroplasty with alumina bearings in patients younger than fifty with femoral head osteonecrosis. J Bone Joint Surg Am. 2008; 90:1314–1320.
crossref
TOOLS
ORCID iDs

Shin-Yoon Kim
https://orcid.org/http://orcid.org/0000-0002-5445-648X

Similar articles