Abstract
Purpose
To compare the short-term clinical outcomes of total hip arthroplasty (THA) with a large diameter femoral head (36 mm) and bipolar hemiarthroplasty (BA) in physiologically active elderly patients with femoral neck fractures.
Materials and Methods
This non-concurrent clinical trial included 169 patients with femoral neck fractures, who had been treated with prosthetic replacement from February 2004 and June 2007. Eighty-nine and 80 cases underwent BA and THA, respectively. The mean follow-up period was 36 months (18-52). The clinical outcomes were analyzed, and the latest follow-up radiographs were assessed to determine the number of complications.
Intracapsular femoral neck fractures are common orthopedic injuries. However, there is some controversy regarding the optimal surgical treatment for these injuries.1) Prosthetic replacement of the femoral head is one of the options for treating a displaced intracapsular femoral neck fracture in elderly patients.2) The proponents of arthroplasty suggest that replacing the femoral head eliminates the risk of revision surgery due to serious complications such as head necrosis, nonunion of the fracture site, etc.3) However, there is some controversy regarding the choice of prosthesis for the joint replacement in patients with intracapsular femoral neck fractures. Bipolar hemiarthroplasty (BA) has a higher incidence of groin pain secondary to acetabular erosion, as well as increased probability of revision arthroplasty.4) Even though total hip arthroplasty (THA) provides good functional results and long-term survival compared with BA, it has several disadvantages such as component dislocation and decreased functional activity due to a limitation in extreme motion.5,6) Larger diameter femoral heads (≥36 mm) have a larger range of motion and believed to be a valuable tool for preventing a dislocation in THA.7-9) Based on this data, it was hypothesized THA with a 36 mm-femoral head will produce superior results without any serious complications compared with BH. We already reported on clinical data on the performance of THA using a large head in patients with a intracapsular femoral neck fracture.10,11) However, it has limited statistical power because of the small sample size. We extended the sample size and analysed the result. The aim of this study was to evaluate the short-term clinical outcomes of THA with large diameter of head and BA in physiologically active elderly patients with displaced intracapsular femoral neck fractures.
The relevant ethics committee at each participating study center reviewed and approved the study protocol, and all patients provided written informed consent before undergoing the screening procedures. This non-concurrent clinical trial (THA was performed at the first regular period of the time, and BA performed at the following regular period of the time) included 169 patients with displaced unilateral intracapsular femoral neck fractures, who had been treated with prosthetic replacement from February 2004 and June 2007. One hundred sixty-nine patients underwent either THA or BA. The inclusion criteria were a normal cognitive function (a mini-mental score12) of >6), an ability to be independent and ambulant prior to the injury, no pre-existing hip disease, age range of the patient between 65 and 90, femoral head more than 44 mm in diameter (If femoral head less than 44 mm can't use large femoral head (36 mm) component), and a fitness for surgery. The mean follow-up period was 36 months (18-52). For the THA group, the mean age of the patients was 75.5 (range, 66-85; 14 male and 66 female). The postoperative leg length discrepancy was -3.6 mm (SD, ±2.4), and the difference in the abductor offset was 3.8 mm (SD, ±2.1) shorter than contralateral normal side. For the BA group, the mean age of the patients was 77.6 (range, 60-85; 16 male and 73 female). The postoperative leg length discrepancy was -4.0 mm (SD, ±2.6), and the difference in the abductor offset was 4.0 mm (SD, ±2.0)(Table 1). A cementless metal shell with a porous coating (Trilogy®, Zimmer Inc., Warsaw, IN) and 36 mm Cobalt-chrome femoral head and a highly cross-linked polyethylene liner with an inner diameter of 36 mm (Longevity®, Zimmer Inc., Warsaw, IN) were placed in all patients undergoing THA. Based on the surgeon's preference, one or two screw augmentations were performed. Acetabular component was the Multipolar® (Zimmer Inc., Warsaw, IN) in BA. Versys (Zimmer Inc., Warsaw, IN) was used as components in the patients who underwent cemented femoral fixation (42 cases in group 1 and 47 in group 2) and FMT (Zimmer Inc., Warsaw, IN) was used as components in the patients who underwent uncemented femoral fixation (38 cases in group 1 and 42 in group 2). All the surgical procedures were performed by the single surgeon using a modified Hardinge's approach with the patient in the lateral position. All the patients had a capsular repair closure. Prophylactic antibiotics were administrated to all patients. The post-operative protocol was the same in all patients. The patients were allowed to sit on the first post-operative day. They were allowed to stand with support when they were able to do so. There was no limitation in the ROM, and an abduction pillow was not used. The clinical and radiographic examinations were assessed by an independent surgeon, who had a few experience in the orthopedic department, and was blinded to the treatment method. The clinical outcomes of the two groups of hips were analyzed using the Harris Hip Score13) and the Merle d'Aubigne and Postel method14). The Harris hip score was classified as excellent (91-100), good (81-90), fair (71-80), and poor (61-70). The Merle d'Aubigne and Postel classification was categorized to six levels according to the level of pain, mobility, and ability to walk. The radiographic examinations included an anteroposterior (AP) view of the pelvis centered over the pubis, and a shoot through lateral of the hip. The femoral components were assessed using Engh's method15) in the case with uncemented fixation, and Barrack's method16) with cemented fixation at the postoperative radiographs. The patients were followed at 6 weeks, at 3 months, 6 months and then 1 year after the index operation. The latest follow-up radiographs were assessed and compared with the original postoperative radiographs to determine the number of complications such as osteolysis, loosening, fracture, dislocation, etc. We also focused on the development of the early complications such as dislocation and infection. The relationship between the two groups in terms of the operation time and intraoperative bleeding volume was assessed using a Mann-Whitney test.
The Harris hip score of the THA group was excellent in 56 cases (70%) and good in 17 cases (21%). The Harris hip score of the BA group was excellent in 51 cases (57.3%) and good in 30 cases (34%)(Table 2). However, the difference was not statistically significant (p=0.11). From the Merle d'Aubigne and Postel classification, the level according to the pain factor was 4 in 4 cases (6%) in the THA group. The pain level of the BA group was 3 in 6 cases (7%) and level 4 in 10 cases (11%). The difference was statistically significant (p=0.04). The level according to the mobility factor was 6 in 72 cases (90%) in the THA group. The mobility level of the BA group was 6 in 63 cases (71%). The difference was statistically significant (p=0.05)(Fig. 1). The level according to the walking factor was 4 in 4 cases (5%) in the THA group. The walking level of the BA group was level 3 in 2 cases (3.4%) and 4 in 10 cases (11%)(Table 3). The difference was marginally significant (p=0.06). The mean operation time was 72.5 and 61.5 minutes in the THA and BA groups, respectively. The difference was statistically significant (p=0.02). The mean intraoperative blood loss was 470 ml and 455 ml in the THA and BA groups, respectively. The difference was not statistically significant (p=0.096). No complications including dislocations and infections developed in the two groups. The radiographic exams showed stable fixation in all patients with the uncemented femoral components, and Barrack type A or B in the cemented femoral components. There were no cases of osteolysis, loosening, and fracture in the pelvis or proximal femur.
The prosthetic replacement of the femoral head in the active elderly patients with intracapsular femoral neck fractures eliminates the concern regarding the re-operation due to fixation failure, nonunion, and avascular necrosis of the femoral head.2,3) However, the best choice of the prosthesis for joint replacement in patients with femoral neck fractures is controversial. BA has the advantages of a lower probability of dislocation and being a simple surgical technique. However, the main concern is the possibility of occurrence of the protrusio acetabuli from the acetabular erosion, groin and thigh pain, less survival at the long-term follow-up than THA, and the higher probability of a second operation.4) Even though the total hip arthroplasty (THA) provides good functional results and long-term survival compared with BA, it can develop serious complications such as a dislocation in the early post-operative period.5,6) Patients with the intracapsular femoral neck fractures have a high risk of a post-operative dislocation. The size of the replaced head is a contributing factor to incidence of dislocation.17) Larger diameter femoral heads are believed to have less chance of dislocation and further more facilitates increased ROM. There is limitation in the widespread use of larger diameter femoral head against conventional polyethylene because of the risk of accelerated wear and resulting osteolysis. The development of new polyethylene with improved wear characteristics in the early laboratory and clinical studies could be reduce the this risk. In this series from the Merle d'Aubigne and Postel classification categorized to six levels according to the level of pain, mobility, and ability to walk, the THA group had better results. Despite there being no limitation of ROM in the early post-operative period, no dislocation was encountered in either group. However, there is some controversy regarding the use of highly cross-linked polyethylene. Even though a few edge fractures of the highly cross-linked polyethylene were attributed to the component mal-position,9) the possibility of fatigue failure due to the decrease in yield strength and ultimate tensile strength from high dose radiation emphasize the need for long-term in vivo studies in young active patients.10,11) However, the patients with intracapsular femoral neck fractures caused by osteoporosis often have coexisting medical problems with limited life expectancy, which means that the demands for daily livings are low. Early post-operative complications such as a dislocation are more important factors in their management. From this point of view, a THA with large diameter femoral head is recommended for the management in patients with intraarticular femoral neck fractures because THA produces a better result than BA. However, it should be noted that this study has limited statistical power because of the sample that was not prospectively randomized. Even though a highly cross-linked polyethylene shows good short and mid-term results in vivo and long-term in vitro study, a long-term in vivo study will be needed to justify its continued use. Given the relatively decrease in life expectancy of patients with intracapsular femoral neck fractures, it would be possible to study on the clinical and functional outcomes in the early post-operative period.
Figures and Tables
References
1. Parker MJ. The management of intracapsular fractures of the proximal femur. J Bone Joint Surg Br. 2000. 82:937–941.
2. Lu Yao GL, Keller RB, Littenberg B, Wennberg JE. Outcomes after displaced fractures of the femoral neck. A meta-analysis of one hundred and six published reports. J Bone Joint Surg Am. 1994. 76:15–25.
3. Chua D, Jagal SB, Schatzker J. An orthopaedic surgeon survey on the treatment of displaced femoral neck fracture: opposing views. Can J Surg. 1997. 40:271–277.
4. Sierra RJ, Cabanela ME. Conversion of failed hip arthroplasties after femoral neck fractures. Clin Orthop Relat Res. 2002. 399:129–139.
5. Karthik K, George T. Functional outcome of fracture neck of femur treated with total hip replacement versus bipolar hemiarthroplasty in a South Asian population. Arch Orthop Trauma Surg. 2006. 126:545–548.
6. Keating JF, Grant A, Masson M, Scott NW, Forbes JF. Randomized comparison of reduction and fixation, bipolar hemiarthroplasty, and total hip arthroplasty. Treatment of displaced intracapsular hip fractures in healthy older patients. J Bone Joint Surg Am. 2006. 88:249–260.
7. Burroughs BR, Rubash HE, Harris WH. Femoral head sizes larger than 32 mm against highly cross-linked polyethylene. Clin Orthop Relat Res. 2006. 405:150–157.
8. Geller JA, Malchau H, Bragdon C, Green M, Harris WH, Freiberg AA. Large diameter femoral heads on highly cross-linked polyethylene. Clin Orthop Relat Res. 2006. 447:53–59.
9. Harris WH. Highly cross-linked, electron-beam-irradiated, melted polyethylene: some pros. Clin Orthop Relat Res. 2004. 429:63–67.
10. Cho MR, Lee HS. Early results after the treatment with total hip arthroplasty with larger diameter femoral head versus bipolar arthroplasty in patients with femoral neck fractures. The Journal of Korean Hip Societ. 2007. 19:463–467.
11. Cho MR, Chae SB. A use of large femoral head in total hip arthroplasty -Early Follow-up Results-. J Korean Hip Soc. 2007. 19:150–154.
12. Folstein MF, Folstein SE, McHugh PR. "Mini-mental state." A practical method for grading the cognitive state of patients for the clinician. J Psychiatr Res. 1975. 12:189–198.
13. Harris WH. Traumatic arthritis of the hip after dislocation and acetabular fracture: treatment by mold arthroplasty. An end-result study using a new method of results evaluation. J Bone Joint Surg Am. 1969. 51:737–755.
14. d'Aubigne R, Postel M. Functional results of hip arthroplasty with acrylic prosthesis. J Bone Joint Surg Am. 1954. 36:451–475.
15. Engh CA, Bobyn JD, Glassman AH. Porous-coated hip replacement. The factors govering bone ingrowth, stress shielding and clinical results. J Bone Joint Surg Br. 1987. 69:45–55.
16. Barrack RL, Mulory JR, Harris WH. Improved cementing techniques and femoral component loosening in young patients with hip arthroplasty. A 12 year radiologic review. J Bone Joint Surg Br. 1992. 74:385–389.