Journal List > J Korean Orthop Assoc > v.42(4) > 1012684

Oh, Kim, Park, Min, Lee, Ihn, Lee, and Oh: Anterior Plating and Ilio-sacral Screwing for Unstable Pelvic Injury

Abstract

Purpose

To evaluate the effectiveness of iliosacral screw fixation with anterior plating in the management of an unstable pelvic ring injury.

Materials and Methods

Nineteen patients with an unstable pelvic ring injury were enrolled in this retrospective study. All patients were followed up for at least 1 year. The mean age of the patients was 43 years. According to the AO-OTA classification, there were five B2 injuries, 11 C1 injuries, and 3 C2 injuries. After anterior fixation by plating, ilio-sacral screw fixation was performed percutaneously under the C-arm guide.

Results

All cases united except for 1 case of nonunion at the pubic ramus. The radiology results showed 9, 7, 2 and 1 case of anatomic, nearly anatomic, moderate and poor reduction, respectively. Sixteen out of 19 patients had a good or excellent functional result. Two moderate and one poor result were from an unsatisfactory reduction in a type C injury with the residual neurological signs. Screw misplacement with neurological compromise occurred in one patient but there were no adverse sequelae after its removal. Regarding the complications, there were two cases of screw loosening, two cases of anterior metal failures, and 1 case of a deep infection.

Conclusion

Percutaneous ilio-sacral screwing with anterior plating may be a useful method for treating unstable pelvic ring injuries, and the reduction quality and neurological signs are important.

Figures and Tables

Fig. 1
A 39-year-man suffered a vertical shear injury (AO-OTA type C1 injury) of the pelvic ring with a fracture of the right femur and left acetabulum. CT scan revealed a sacral fracture of Denis type II with evident pubic rami fractures.
jkoa-42-483-g001
Fig. 2
Using the long reconstruction plate, the anterior disruption of pelvic ring was reduced. The posterior ring was percutaneously fixed by a 7.0 mm cannulated screw. The CT scan shows a well reduced pelvic ring and a good location of the ilio-sacral screw.
jkoa-42-483-g002
Fig. 3
At 2 years, all fractures healed with anatomical reduction. The patient showed excellent function (Fig. 3).
jkoa-42-483-g003
Table 1
Deta for Patients with an Unstable Pelvic Ring Injury
jkoa-42-483-i001

VS, vertical shear injury; LC, lateral compression injury; Type, AO-OTA classification; ISS, injury severity score.

References

1. Burgess AR, Eastridge BJ, Young JW, et al. Pelvic ring disruptions: effective classification system and treatment protocols. J Trauma. 1990. 30:848–856.
2. Comstock CP, van der Meulen MC, Goodman SB. Biomechanical comparison of posterior internal fixation techniques for unstable pelvic fractures. J Orthop Trauma. 1996. 10:517–522.
crossref
3. Denis F, Davis S, Comfort T. Sacral fractures: an important problem. Retrospective analysis of 236 cases. Clin Orthop Relat Res. 1988. 227:67–81.
4. Griffin DR, Starr AJ, Reinert CM, Jones AL, Whitlock S. Vertically unstable pelvic fractures fixed with percutaneous iliosacral screws: does posterior injury pattern predict fixation failure? J Orthop Trauma. 2003. 17:399–405.
crossref
5. Gruen GS, Leit ME, Gruen RJ, Peitzman AB. The acute management of hemodynamically unstable multiple trauma patients with pelvic ring fractures. J Trauma. 1994. 36:706–711.
crossref
6. Keating JF, Werier J, Blachut P, Broekhuyse H, Meek RN, O'Brien PJ. Early fixation of the vertically unstable pelvis: the role of iliosacral screw fixation of the posterior lesion. J Orthop Trauma. 1999. 13:107–113.
crossref
7. Kellam JF, McMurtry RY, Paley D, Tile M. The unstable pelvic fracture. Operative treatment. Orthop Clin North Am. 1987. 18:25–41.
8. Kim JJ, Jeong YG, Chang JS, Kim KY, Baek SK. Percutaneous iliosacral screw fixation in unstable pelvic ring injury. J Korean Orthop Assoc. 1999. 34:1087–1092.
crossref
9. Kim JJ, Kim JW, Chang JS. Clinical outcome of AO type C pelvic ring injury. J Korean Orthop Assoc. 2005. 40:181–187.
crossref
10. Latenser BA, Gentilello LM, Tarver AA, Thalgott JS, Batdorf JW. Improved outcome with early fixation of skeletally unstable pelvic fractures. J Trauma. 1991. 31:28–31.
crossref
11. Leighton R, Waddell J. Open reduction and internal fixation of vertical fractures of the pelvis using the sacroiliac joint plate. J Orthop Trauma. 1991. 5:255–258.
12. Matta JM, Saucedo T. Internal fixation of pelvic ring fractures. Clin Orthop Relat Res. 1989. 242:83–97.
crossref
13. Mears DC, Capito CP, Deleeuw H. Posterior pelvic disruptions managed by the use of the Double Cobra Plate. Instr Course Lect. 1988. 37:143–150.
14. Pohlemann T, Angst M, Schneider E, Ganz R, Tscherne H. Fixation of transforaminal sacrum fractures: a biomechanical study. J Orthop Trauma. 1993. 7:107–117.
15. Pohlemann T, Bosch U, Gansslen A, Tscherne H. The Hannover experience in management of pelvic fractures. Clin Orthop Relat Res. 1994. 305:69–80.
crossref
16. Ragnarsson B, Olerud C, Olerud S. Anterior square-plate fixation of sacroiliac disruption. 2-8 years follow-up of 23 consecutive cases. Acta Orthop Scand. 1993. 64:138–142.
crossref
17. Rommens PM, Hessmann MH. Staged reconstruction of pelvic ring disruption: differences in morbidity, mortality, radiologic results, and functional outcomes between B1, B2/B3, and C-type lesions. J Orthop Trauma. 2002. 16:92–98.
crossref
18. Routt ML Jr, Meir MC, Kregor PK, Mayo KM. Percutaneous iliosacral screws with the patient supine technique. Operat Tech Orthop. 1993. 3:35–45.
19. Routt ML, Kregor PJ, Simonian PT, Mayo KA. Early results of percutaneous iliosacral screws placed with the patient in the supine position. J Orthop Trauma. 1995. 9:207–214.
20. Routt ML, Simonian PT, Agnew SG, Mann FA. Radiographic recognition of the sacral alar slope for optimal placement of iliosacral screws: a cadaveric and clinical study. J Orthop Trauma. 1996. 10:171–177.
21. Sagi HC, Ordway NR, DiPasquale T. Biomechanical analysis of fixation for vertically unstable sacroiliac dislocations with iliosacral screws and symphyseal plating. J Orthop Trauma. 2004. 18:138–143.
crossref
22. Stocks GW, Gabel GT, Noble PC, Hanson GW, Tullos HS. Anterior and posterior internal fixation of vertical shear fractures of the pelvis. J Orthop Res. 1991. 9:237–245.
crossref
23. Tile M. Pelvic ring fractures: should they be fixed? J Bone Joint Surg Br. 1988. 70:1–12.
crossref
24. Tornetta P 3rd, Dickson K, Matta JM. Outcome of rotationally unstable pelvic ring injuries treated operatively. Clin Orthop Relat Res. 1996. 329:147–151.
crossref
25. Van den Bosch EW, Van der Kleyn R, Hogervorst M, Van Vugt AB. Functional outcome of internal fixation for pelvic ring fractures. J Trauma. 1999. 47:365–371.
crossref
TOOLS
ORCID iDs

Woo-Kie Min
https://orcid.org/http://orcid.org/0000-0003-2079-5085

Similar articles