Abstract
Purpose
This research aims at developing a simulation system for training of the correct placement of isometric points in arthroscopic reconstruction of anterior cruciate ligaments, using personal computer-based software and rapid prototyping knee models.
Materials and Methods
CT scan images of the knee joints of thirteen patients were used. Simulation software was developed on V-works(Clinic3D Inc.), a three-dimensional medical imaging system. Rapid prototyping models were made of hardened starch with a 0.178 mm slice thickness.
Results
In the first phase, trainee surgeons can study the positions of the bony attachments of healthy anterior cruciate ligaments, and compare their multiplanar reformatting images and a three-dimensional computer model of the bones. In the second phase, trainee sur-geons can place isometric points on the three-dimensional computer models and compare the results with the points set by a supervis-ing surgeon. Finally, rapid prototyping models, which are almost identical to the actual bones, are produced to allow the trainees to observe the isometric points marked on the models.