Journal List > J Korean Ophthalmol Soc > v.58(4) > 1010748

Choi, Lee, Park, and Kim: A Case of SmartPlug Partial Extrusion through Canalicular Mucosa

Abstract

Purpose

To report a case of a SmartPlug that partially extruded through the canalicular mucosa.

Case summary

A 62-year-old female patient visited our Department of Ophthalmology for redness and discharge in her right eye that began worsening a week prior. The patient was diagnosed with severe dry eye syndrome via Sjogren's syndrome. The SmartPlug was inserted into her left lower punctum 12 years prior, and another plug was inserted in the right 9 years prior. Nothing notable was found in her history. The best corrected visual acuity and intraocular pressure at the initial visit was 1.0 and 14 mmHg, respectively, in both eyes. Swelling, erythema, and tenderness at the right lower punctum were identified. As we irri-gated the lower lacrimal system, partial obstruction was suspected and a large amount of mucopurulent discharge in the con-junctival fornix with conjunctival injection was seen. Under the right lower punctum, a 1 × 1 mm yellowish foreign body was parti-ally extruding from the canalicular mucosa. The foreign body was removed, and a round defect was left. The patient’s symptom completely resolved after 4 weeks of topical antibiotics and ointment treatment

Conclusions

In patients who have a SmartPlug inserted prior to visits for redness and discharge, a SmartPlug plug extrusion should be considered.

References

1. Freeman JM. . The punctum plug: evaluation of a new treatment for the dry eye. Trans Sect Ophthalmol Am Acad Ophthalmol Otolaryngol. 1975; 79:OP874-9.
2. Balaram M, Schaumberg DA, Dana MR. . Efficacy and tolerability outcomes after punctal occlusion with silicone plugs in dry eye syndrome. Am J Ophthalmol. 2001; 131:30–6.
crossref
3. Lee MJ, Lee KW, Kim NJ. . Canaliculitis associated with SmartPlug(TM) punctal plug insertion: clinical features and management. J Korean Ophthalmol Soc. 2009; 50:821–5.
4. Lee J, Flanagan JC. . Complications associated with silicone intra-canalicular plugs. Ophthal Plast Reconstr Surg. 2001; 17:465–9.
crossref
5. Mazow ML, McCall T, Prager TC. . Lodged intracanalicular plugs as a cause of lacrimal obstruction. Ophthal Plast Reconstr Surg. 2007; 23:138–42.
crossref
6. White WL, Bartley GB, Hawes MJ. . Iatrogenic complications related to the use of Herrick Lacrimal Plugs. Ophthalmology. 2001; 108:1835–7.
7. SmartPlug Study Group . . Management of complications after in-sertion of the SmartPlug punctal plug: a study of 28 patients. Ophthalmology. 2006; 113:1859. e1-6.
8. Maguire LJ, Bartley GB. . Complications associated with the new smaller size freeman punctal plug. Case report. Arch Ophthalmol. 1989; 107:961–2.
crossref
9. Nelson CC. . Complications of freeman plugs. Arch Ophthalmol. 1991; 109:923–4.
crossref
10. Soparkar CN, Patrinely JR, Hunts J. . The perils of permanent punctal plugs. Am J Ophthalmol. 1997; 123:120–1.
crossref
11. Gerding H, Küppers J, Busse H. . Symptomatic cicatrizial occlusion of canaliculi after insertion of Herrick lacrimal plugs. Am J Ophthalmol. 2003; 136:926–8.
crossref
12. Jones CE, Anklesaria M, Gordon AD. . Retrospective safety study of the herrick lacrimal plug: a device used to occlude the lac-rimal canaliculus. CLAO J. 2002; 28:206–10.
13. Fayet B, Assouline M, Hanush S. . Silicone punctal plug ex-trusion resulting from spontaneous dissection of canalicular mucosa: a clinical and histopathologic report. Ophthalmology. 2001; 108:405–9.
crossref
14. Kim BM, Osmanovic SS, Edward DP. . Pyogenic granulomas after silicone punctal plugs: a clinical and histopathologic study. Am J Ophthalmol. 2005; 139:678–84.
crossref
15. Chou TY, Perry HD, Donnenfeld ED, Solomon R. . Pyogenic gran-uloma formation following placement of the Medennium SmartPLUG punctum plug. Cornea. 2006; 25:493–5.
crossref

Figure 1.
Initial anterior segment photography. A 1 × 2 mm sized cylindrical yellowish foreign body (black arrow) parti-ally extruded under the right lower punctum.
jkos-58-459f1.tif
Figure 2.
After 4 weeks. (A) Round canalicular mucosa defect after foreign body removal and (B) completely resolving state after 4 weeks.
jkos-58-459f2.tif
Figure 3.
The foreign body. Removed foreign body was fully covered with discharge and blood clot. After dissection, It was found to be a 1 × 2 mm-sized SmartPlug.
jkos-58-459f3.tif
TOOLS
Similar articles