Abstract
Purpose
To report a case of pigment dispersion syndrome and reverse pupillary block secondary to the implantation of implantable collamer lens (ICL) with a central hole (AQUA ICL®) that was treated with ICL removal and laser peripheral iridotomy (LPI).
Case summary
A 29-year-old woman with myopia in both eyes underwent implantation of AQUA ICL®. Four weeks post-operatively, the intraocular pressure (IOP) increased to 34 mm Hg and the patient showed pigment dispersion syndrome in both eyes. Since the IOP did not reduce with the maximum tolerable medical therapy, the ICLs were removed 8 weeks after implantation. The pigment dispersion subsided and IOP reduced shortly after ICL removal. However, 4 weeks after removal of ICL, posterior iris bowing and reverse pupillary block occurred in the right eye and the IOP increased to 46 mm Hg. LPI was performed in the right eye, and the reverse pupillary block was dissolved after a reduction in pigment dispersion. The IOP sub-sequently normalized to 13 mm Hg. Two weeks later, prophylactic LPI was performed in the left eye. Four weeks after prophylactic LPI, selective laser trabeculoplasty was performed on both eyes. As a result, the IOP was 11 mm Hg in the right eye and 12 mm Hg in the left eye after 4 weeks of treatment with topical IOP-lowering medications.
References
1. Sanders DR, Doney K, Poco M. ICL in Treatment of Myopia Study Group. United States Food and Drug Administration clinical trial of the Implantable Collamer Lens (ICL) for moderate to high abdominal: three-year follow-up. Ophthalmology. 2004; 111:1683–92.
2. Fernandes P, González-Méijome JM, Madrid-Costa D, et al. Implantable collamer posterior chamber intraocular lenses: a abdominal of potential complications. J Refract Surg. 2011; 27:765–76.
3. Sánchez-Galeana CA, Zadok D, Montes M, et al. Refractory abdominal pressure increase after phakic posterior chamber intraocular lens implantation. Am J Ophthalmol. 2002; 134:121–3.
4. Pak KY, Kim HS, Lee JW. A case of pigmentary glaucoma after posterior chamber phakic intraocular lens implantation. J Korean Ophthalmol Soc. 2013; 54:994–9.
5. Brandt JD, Mockovak ME, Chayet A. Pigmentary dispersion abdominal induced by a posterior chamber phakic refractive lens. Am J Ophthalmol. 2001; 131:260–3.
6. Abela-Formanek C, Kruger AJ, Dejaco-Ruhswurm I, et al. Gonioscopic changes after implantation of a posterior chamber lens in phakic myopic eyes. J Cataract Refract Surg. 2001; 27:1919–25.
7. Son GS, Kim JW, Lim TH, et al. Comparison of clinical outcomes in implantable collamer lens implantation between AQUA ICL(R) and conventional ICL. J Korean Ophthalmol Soc. 2015; 56:1316–23.
8. Lisa C, Naveiras M, Alfonso-Bartolozzi B, et al. Posterior chamber collagen copolymer phakic intraocular lens with a central hole to correct myopia: one-year follow-up. J Cataract Refract Surg. 2015; 41:1153–9.
9. Campbell DG. Pigmentary dispersion and glaucoma. A new theory. Arch Ophthalmol. 1979; 97:1667–72.
10. Karickhoff JR. Pigmentary dispersion syndrome and pigmentary glaucoma: a new mechanism concept, a new treatment, and a new technique. Ophthalmic Surg. 1992; 23:269–77.
11. Alfonso JF, Lisa C, Abdelhamid A, et al. Three-year follow-up of subjective vault following myopic implantable collamer lens implantation. Graefes Arch Clin Exp Ophthalmol. 2010; 248:1827–35.
12. Chung TY, Park SC, Lee MO, et al. Changes in iridocorneal angle structure and trabecular pigmentation with STAAR implantable collamer lens during 2 years. J Refract Surg. 2009; 25:251–8.
13. Kawamorita T, Uozato H, Shimizu K. Fluid dynamics simulation of aqueous humour in a posterior-chamber phakic intraocular lens with a central perforation. Graefes Arch Clin Exp Ophthalmol. 2012; 250:935–9.
14. Scott A, Kotecha A, Bunce C, et al. YAG laser peripheral iridotomy for the prevention of pigment dispersion glaucoma a abdominal, randomized, controlled trial. Ophthalmology. 2011; 118:468–73.