Youn, Jeon, Lee, Lee, Nam, Park, Kim, Ki, and Kim: Feasibility of Automated Detection of Inter-fractional Deviation in Patient Positioning Using Structural Similarity Index: Preliminary Results

Abstract

The modern radiotherapy technique which delivers a large amount of dose to patients asks to confirm the positions of patients or tumors more accurately by using X-ray projection images of high-definition. However, a rapid increase in patient's exposure and image information for CT image acquisition may be additional burden on the patient. In this study, by introducing structural similarity (SSIM) index that can effectively extract the structural information of the image, we analyze the differences between daily acquired x-ray images of a patient to verify the accuracy of patient positioning. First, for simulating a moving target, the spherical computational phantoms changing the sizes and positions were created to acquire projected images. Differences between the images were automatically detected and analyzed by extracting their SSIM values. In addition, as a clinical test, differences between daily acquired x-ray images of a patient for 12 days were detected in the same way. As a result, we confirmed that the SSIM index was changed in the range of 0.85∼1 (0.006∼1 when a region of interest (ROI) was applied) as the sizes or positions of the phantom changed. The SSIM was more sensitive to the change of the phantom when the ROI was limited to the phantom itself. In the clinical test, the daily change of patient positions was 0.799∼0.853 in SSIM values, those well described differences among images. Therefore, we expect that SSIM index can provide an objective and quantitative technique to verify the patient position using simple x-ray images, instead of time and cost intensive three-dimensional x-ray images.

References

1. Paquin D, Levy D, Xing D. Multiscale registration of planning CT and daily cone beam CT images for adaptive radiation therapy. Med phys. 36:4–11. 2009.
crossref
2. Yeung AR, Li JG, Shi W, Newlin HE, et al. Tumor localization using cone-beam CT reduces setup margins in conventionally fractionated radiotherapy for lung tumors. Int J Radiat Oncol Biol Phys. 74:1100–1107. 2009.
crossref
3. Elstrom UV, Wysocka BA, Muren LP, et al. Daily kV cone-beam CT and deformable image registration as a method for studying dosimetric consequences of anatomic changes in adaptive IMRT of head and neck cancer. Acta oncologica. 49:1101–1108. 2010.
crossref
4. Ost P, De Meerleer G, De Gersem W, et al. Analysis of prostate bed motion using daily cone-beam computed tomography during postprostatectomy radiotherapy. Int J Radiat Oncol Biol Phys. 79:188–194. 2011.
crossref
5. Veiga C, McClelland J, Moinuddin S, et al. Toward adaptive radiotherapy for head and neck patients: Feasibility study on using CT-to-CBCT deformable registration for “dose of the day” calculations. Med Phys. 41:031703. 2014.
crossref
6. Wang Z, Bovik AC, Sheikh HR, et al. Image quality assessment: from error visibility to structural similarity. IEEE Trans Imag Proc. 13:600–612. 2004.
crossref
7. Brunet D, Vrscay ER, Wang Z. On the mathematical properties of the structural similarity index. IEEE Trans Imag Proc. 21:1488–1499. 2012.
crossref
8. Chai L, Sheng Y. Optimal design of multichannel equalizers for the structural similarity index. IEEE Trans Imag Proc. 23:5626–5637. 2014.
crossref
9. Channappayya SS, Bovik AC, Caramanis C, et al. Design of linear equalizers optimized for the structural similarity index. IEEE Trans Imag Proc. 17:857–872. 2008.
crossref
10. Channappayya SS, Bovik AC, Heath RW Jr.Rate bounds on SSIM index of quantized images. IEEE Trans Imag Proc. 17:1624–1639. 2008.
crossref
11. Charrier C, Knoblauch K, Maloney LT. Optimizing multiscale SSIM for compression via MLDS. IEEE Trans Imag Proc. 21:4682–4694. 2012.
crossref
12. Kolaman A, Yadid-Pecht O. “Quaternion structural similarity: a new quality index for color images. IEEE Trans Imag Proc. 21:1526–1536. 2012.
crossref
13. Rehman A, Zhou R. Reduced-reference image quality assessment by structural similarity estimation. IEEE Trans Imag Proc. 21:3378–3389. 2012.
crossref
14. Sampat MP, Wang Z, Gupta S. Complex wavelet structural similarity: a new image similarity index. IEEE Trans Imag Proc. 18:2385–2401. 2009.
crossref
15. Wang S, Rehman A, Wang Z. Perceptual video coding based on SSIM-inspired divisive normalization. IEEE Trans Imag Proc. 22:1418–1429. 2013.
16. Zujovic J, Pappas TN, Neuhoff DL. Structural texture similarity metrics for image analysis and retrieval. IEEE Trans Imag Proc. 22:2545–2558. 2013.
crossref
17. Siddon RL. Fast calculation of the exact radiological path for a three-dimensional CT array. Med Phys. 12:252–255. 1985.
crossref
18. De Man B, Basu S. Distance-driven projection and backprojection in three dimensions. Physics in medicine and biology. 49:2463–2475. 2004.

Fig. 1.
구형 팬텀의 반지름 및 중 심 위치 변화에 대한 모식도. 이 때 r은 반지름, Δr은 반지름 변화 량, 그리고 d는 중심 위치의 이동 거리를 의미한다.
pmp-26-258f1.tif
Fig. 2.
(a) 기준 위치의 팬텀의 가 상 투사영상, (b) 팬텀의 반지름과 중심 위치 변화가 고려된 투사 영 상, (c) a와 b 영상의 차이를 나타 내는 SSIM 분포.
pmp-26-258f2.tif
Fig. 3.
전체 산술평균을 이용한 SSIM 계산 결과: (a) 20, 40, 60, 및 80 mm 반지름을 가지는 팬텀의 중심위치 변화에 따른 SSIM 변화의 추이와 (b) 20, 40, 및 60 mm의 반지름을 가지는 팬텀에서 반지름의 변화가 발생할 때의 SSIM 경향.
pmp-26-258f3.tif
Fig. 4.
ROI을 팬텀 내부로 가정하고 계산된 SSIM 변화 추이: (a) 20, 40, 60, 및 80 mm 반지름을 가지는 팬텀의 중심위치 변화에 따른 SSIM 변화의 추이와 (b) 20, 40, 및 60 mm의 반지름을 가지는 팬텀에서 반지름의 변화가 발생할 때의 SSIM 경향.
pmp-26-258f4.tif
Fig. 5.
Δr을 −30∼30 mm, d를 0∼50 mm까지 변화시키면서 획 득된 SSIM 계산결과(ROI내의 픽셀들에 대한 산술평균을 수행).
pmp-26-258f5.tif
Fig. 6.
OBI로 촬영된 참조 투사영 상(a)과 해당영상의 히스토그램 평 활화 결과(b): 본 연구에서는 OBI 투사영상으로부터 보다 많은 구조 정보를 추출하기 위해 전체 영상 에 대해 히스토그램 평활화 연산 후 SSIM 계산을 수행하였다.
pmp-26-258f6.tif
Fig. 7.
환자 위치 확인을 위해 12일간 매일 촬영하여 SSIM 분석한 결과 분포. (a)는 기준 영상인 첫 번째 촬영 영상이며, (b)∼(l)은 촬영 순서대로 배열한 매일 촬영한 영상들의 SSIM 분포들임.
pmp-26-258f7.tif
Fig. 8.
기준영상을 제외한 11장의 투사영상에 대한 SSIM 계산결과(a)와 디텍터 시스템의 픽셀 수에 따른 소요 연산시간 도시(b).
pmp-26-258f8.tif
TOOLS
Similar articles