<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.0 20120330//EN" "JATS-journalpublishing1.dtd">
<article article-type="letter" dtd-version="1.0" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">APM</journal-id>
<journal-title-group>
<journal-title>Anesthesia and Pain Medicine</journal-title><abbrev-journal-title>Anesth Pain Med</abbrev-journal-title></journal-title-group>
<issn pub-type="ppub">1975-5171</issn>
<issn pub-type="epub">2383-7977</issn>
<publisher>
<publisher-name>Korean Society of Anesthesiologists</publisher-name></publisher></journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.17085/apm.20095</article-id>
<article-id pub-id-type="publisher-id">apm-20095</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Letter to the Editor</subject>
</subj-group></article-categories>
<title-group>
<article-title>Change of inspired oxygen concentration and temperature in low flow anesthesia</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<contrib-id contrib-id-type="orcid">http://orcid.org/0000-0003-2023-8705</contrib-id>
<name><surname>Yang</surname><given-names>Hong Seuk</given-names></name>
<xref ref-type="corresp" rid="c1-apm-20095"/>
</contrib>
<contrib contrib-type="author">
<contrib-id contrib-id-type="orcid">http://orcid.org/0000-0002-6587-3756</contrib-id>
<name><surname>Park</surname><given-names>Dong Ho</given-names></name>
</contrib>
<contrib contrib-type="author">
<contrib-id contrib-id-type="orcid">http://orcid.org/0000-0002-8830-3406</contrib-id>
<name><surname>Jeong</surname><given-names>Chang Young</given-names></name>
</contrib>
<aff id="af1-apm-20095">
Department of Anesthesiology and Pain Medicine, Daejeon Eulji Medical Center, Medical College, Eulji University, Daejeon, <country>Korea</country></aff>
</contrib-group>
<author-notes>
<corresp id="c1-apm-20095">Corresponding Author: Hong Seuk Yang, M.D., Ph.D. Department of Anesthesiology and Pain Medicine, Daejeon Eulji Medical Center, Medical College, Eulji University, 95 Dunsanseo-ro, Seo-gu, Daejeon 35233, Korea Tel: 82-42-611-3883, Fax: 82-42-259-1111 E-mail: <email>hsyang@amc.seoul.kr</email></corresp>
</author-notes>
<pub-date pub-type="ppub">
<day>31</day>
<month>1</month>
<year>2021</year>
</pub-date>
<pub-date pub-type="epub">
<day>27</day>
<month>1</month>
<year>2021</year></pub-date>
<volume>16</volume>
<issue>1</issue>
<fpage>116</fpage>
<lpage>117</lpage>
<history>
<date date-type="received">
<day>8</day>
<month>12</month>
<year>2020</year></date>
<date date-type="accepted">
<day>13</day>
<month>01</month>
<year>2021</year></date>
</history>
<permissions>
<copyright-statement>Copyright &#x000a9; the Korean Society of Anesthesiologists, 2021</copyright-statement>
<copyright-year>2021</copyright-year>
<license>
<license-p>This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (<ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by-nc/4.0/">http://creativecommons.org/licenses/by-nc/4.0/</ext-link>) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p></license>
</permissions>
<related-article related-article-type="commentary-article" id="ra1-apm-20095" vol="15" page="434"/>
</article-meta></front>
<body>
<p>TO THE EDITOR: For low-flow anesthesia, the anesthesia workstation, monitoring technology and desflurane, sevoflurane, which were a low blood-gas partition coefficient, have gradually been adopted. Low-flow anesthesia is considered effective in maintaining the heat and the moisture of the breathing circuit and preserving the mucociliary function of the respiratory tract. In addition, it is safer and more effective at lowering the economic burden and global warming potential &#x0005b;<xref ref-type="bibr" rid="b1-apm-20095">1</xref>,<xref ref-type="bibr" rid="b2-apm-20095">2</xref>&#x0005d;. We read, with interest, your paper on &#x0201c;Change of inspired oxygen concentration in low flow anesthesia&#x0201d; (<italic>Anesth Pain Med</italic> 2020; 15: 434-40). We appreciate your results and have some questions to discuss.</p>
<p>We have a few questions about the monitoring and the maintenance of body temperature. How did you maintain and monitor the temperature of the operating room? Was the patient&#x00027;s temperature measured only in the esophagus? What was the depth of the esophageal temperature probe? Depending on the room temperature and the depth of insertion, the body temperature can change with ambient influences, such as blood flow of venous return and inhaled gas temperature &#x0005b;<xref ref-type="bibr" rid="b3-apm-20095">3</xref>&#x0005d;. Therefore, the authors used a heated breathing system and a heat moisture exchanger (HME) to heat the breathing circuit. During anesthetic care, the patient&#x02019;s temperature did not show a statistically significant change after 60&#x02013;75 min of low flow. However, it started increasing significantly after 120 min of low flow.</p>
<p>In this study, soda lime (CO<sub>2</sub> absorber) and a standard circular rebreathing circuit with a heated breathing circuit were used. Did you use the HME in the heated breathing circuit? One CO<sub>2</sub> molecule, exhaled by the patient, produces two water (H<sub>2</sub>O) molecules and generates approximately 40&#x000b0;C of heat during its reaction with soda lime. The moisture and heat generated by the reaction are sufficient for the patient&#x00027;s humidification and warmth during anesthesia 30 min after induction &#x0005b;<xref ref-type="bibr" rid="b1-apm-20095">1</xref>,<xref ref-type="bibr" rid="b4-apm-20095">4</xref>&#x0005d;. Therefore, if a low-flow system is used, there is no reason to use a heated breathing circuit and HME, sufficient heat and moisture can be maintained without a heated breathing circuit and HME &#x0005b;<xref ref-type="bibr" rid="b1-apm-20095">1</xref>–<xref ref-type="bibr" rid="b5-apm-20095">5</xref>&#x0005d;. We think that the increased temperature within the circuit is not an advantage but a problem caused by adding the heated breathing circuit and HME during low flow rather than high flow. What do you expect to get if you do not attach either of or both the heating breathing circuit and HME?</p>
</body>
<back>
<fn-group>
<fn fn-type="conflict"><p>CONFLICTS OF INTEREST</p>
<p>No potential conflict of interest relevant to this article was reported.</p></fn>
<fn fn-type="participating-researchers"><p>AUTHOR CONTRIBUTIONS</p><p>Methodology: Hong Seuk Yang. Writing - review &amp; editing: Dong Ho Park. Supervision: Chang Young Jeong.</p></fn></fn-group>
<ref-list>
<title>REFERENCES</title>
<ref id="b1-apm-20095">
<label>1</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Baxter</surname><given-names>AD</given-names></name>
</person-group>
<article-title>Low and minimal flow inhalational anaesthesia</article-title>
<source>Can J Anaesth</source>
<year>1997</year>
<volume>44</volume>
<fpage>643</fpage>
<lpage>52; quiz 652-3</lpage>
</element-citation></ref>
<ref id="b2-apm-20095">
<label>2</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Baum</surname><given-names>JA</given-names></name>
<name><surname>Aitkenhead</surname><given-names>AR</given-names></name>
</person-group>
<article-title>Low-flow anaesthesia</article-title>
<source>Anaesthesia</source>
<year>1995</year>
<volume>50 Suppl</volume>
<fpage>37</fpage>
<lpage>44</lpage>
</element-citation></ref>
<ref id="b3-apm-20095">
<label>3</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Lenhardt</surname><given-names>R</given-names></name>
</person-group>
<article-title>Monitoring and thermal management</article-title>
<source>Best Pract Res Clin Anaesthesiol</source>
<year>2003</year>
<volume>17</volume>
<fpage>569</fpage>
<lpage>81</lpage>
</element-citation></ref>
<ref id="b4-apm-20095">
<label>4</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Parthasarathy</surname><given-names>S</given-names></name>
</person-group>
<article-title>The closed circuit and the low flow systems</article-title>
<source>Indian J Anaesth</source>
<year>2013</year>
<volume>57</volume>
<fpage>516</fpage>
<lpage>24</lpage>
</element-citation></ref>
<ref id="b5-apm-20095">
<label>5</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name><surname>Braz</surname><given-names>JRC</given-names></name>
<name><surname>Braz</surname><given-names>MG</given-names></name>
<name><surname>Hayashi</surname><given-names>Y</given-names></name>
<name><surname>Martins</surname><given-names>RHG</given-names></name>
<name><surname>Betini</surname><given-names>M</given-names></name>
<name><surname>Braz</surname><given-names>LG</given-names></name>
<etal/>
</person-group>
<article-title>Effects of different fresh gas flows with or without a heat and moisture exchanger on inhaled gas humidity in adults undergoing general anaesthesia: A systematic review and meta-analysis of randomised controlled trials</article-title>
<source>Eur J Anaesthesiol</source>
<year>2017</year>
<volume>34</volume>
<fpage>515</fpage>
<lpage>25</lpage>
</element-citation></ref>
</ref-list>
</back></article>