﻿<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.0 20120330//EN" "JATS-journalpublishing1.dtd">
<article xml:lang="en" article-type="research-article" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">APM</journal-id>
<journal-title-group>
<journal-title>Anesthesia and Pain Medicine</journal-title>
<abbrev-journal-title abbrev-type="publisher">Anesth Pain Med</abbrev-journal-title>
</journal-title-group>
<issn pub-type="ppub">1975-5171</issn>
<issn pub-type="epub">2383-7977</issn>
<publisher>
<publisher-name>Korean Society of Neuroscience in Anesthesiology and Critical Care</publisher-name>
<publisher-loc>Korea</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">APM-12-275</article-id>
<article-id pub-id-type="doi">10.17085/apm.2017.12.3.275</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Clinical Research</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Comparison of the endotracheal tube intracuff pressure with cylindrical and tapered cuffs during nitrous oxide exposure: a randomized single-blinded clinical study</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Park</surname>
<given-names>Ha Yeon</given-names>
</name>
<xref ref-type="aff" rid="aff1"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Kim</surname>
<given-names>Daehwan</given-names>
</name>
<xref ref-type="aff" rid="aff1"/>
</contrib>
<contrib contrib-type="author">
<name>
<surname>In</surname>
<given-names>Junyong</given-names>
</name>
<xref ref-type="aff" rid="aff1"/>
<xref ref-type="corresp" rid="cor1"/>
</contrib>
</contrib-group>
<aff xml:lang="en" id="aff1">
<institution>Department of Anesthesiology and Pain Medicine, Dongguk University Ilsan Hospital, Goyang, Korea</institution>
</aff>
<author-notes>
<corresp id="cor1">
Corresponding author: Junyong In, M.D., Ph.D., Department of Anesthesiology and Pain Medicine, Dongguk University Ilsan Hospital, 27, Dongguk-ro, Ilsandong-gu, Goyang 10326, Korea. Tel: 82-31-961-7875, Fax: 82-31-961-7864, E-mail: <email xlink:href="dragona1@dumc.or.kr">dragona1@dumc.or.kr</email>
</corresp>
</author-notes>
<pub-date pub-type="ppub">
<day>31</day>
<month>07</month>
<year>2017</year>
</pub-date>
<pub-date pub-type="epub">
<day>31</day>
<month>07</month>
<year>2017</year>
</pub-date>
<volume>12</volume>
<issue>3</issue>
<fpage>275</fpage>
<lpage>280</lpage>
<history>
<date date-type="received"><day>26</day><month>01</month><year>2017</year></date>
<date date-type="rev-recd"><day>03</day><month>03</month><year>2017</year></date>
<date date-type="accepted"><day>21</day><month>03</month><year>2017</year></date>
</history>
<permissions>
<copyright-statement>Copyright: &#x000a9; Anesthesia and Pain Medicine</copyright-statement>
<copyright-year>2017</copyright-year>
<license>
<license-p>This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (<ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by-nc/4.0">http://creativecommons.org/licenses/by-nc/4.0</ext-link>) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p>
</license>
</permissions>
<abstract>
<sec>
<title>Background:</title>
<p>Tracheal complications caused by excessive mucosal pressure from an inflated endotracheal tube are major concerns during anesthesia; hence, an intracuff pressure of 20&#x2013;30 cmH<sub>2</sub>O is recommended as a clinically acceptable intracuff pressure. Diffusion of nitrous oxide (N<sub>2</sub>O) into the endotracheal tube cuff increases the intracuff pressure, which may also be influenced by the cuff shape. Therefore, we investigated whether the intracuff pressure of a tapered cuff was different from that of a cylindrical cuff in patients undergoing general anesthesia using 60&#x0025; N<sub>2</sub>O.</p>
</sec>
<sec>
<title>Methods:</title>
<p>Twenty-six patients who underwent general anesthesia using 60&#x0025; N<sub>2</sub>O in supine position were randomly allocated to the cylindrical cuff group (Group C) or tapered cuff group (Group T). The baseline intracuff pressure was set at 20 cmH<sub>2</sub>O, and measured every 10 minutes for 60 minutes.</p>
</sec>
<sec>
<title>Results:</title>
<p>The primary outcome was the intracuff pressure at 60 minutes after N<sub>2</sub>O exposure, which was 40 cmH<sub>2</sub>O in Group C (95&#x0025; CI 36&#x2013;44) and 40 cmH<sub>2</sub>O (95&#x0025; CI 35&#x2013;45) in Group T (P = 0.895). The lower confidence limit of the intracuff pressures in both groups exceeded 30 cmH<sub>2</sub>O at 60 minutes of N<sub>2</sub>O exposure, which is the upper limit for clinically acceptable intracuff pressure (20&#x2013;30 cmH<sub>2</sub>O).</p>
</sec>
<sec>
<title>Conclusions:</title>
<p>There was no significant difference in the intracuff pressures between cylindrical and tapered cuffs. Continuous or frequent monitoring is recommended regardless of the duration of the 60&#x0025; N<sub>2</sub>O exposure because the intracuff pressure can exceed 30 cmH<sub>2</sub>O within an hour.</p>
</sec>
</abstract>
<kwd-group>
<kwd>Airway management</kwd>
<kwd>Intratracheal intubation</kwd>
<kwd>Nitrous oxide</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec sec-type="intro">
<title>INTRODUCTION</title>
<p>An endotracheal tube (ETT) cuff plays an important role in preventing aspiration and air leakage during positive-pressure ventilation in the operating room or the intensive care unit and even during tracheal extubation [<xref ref-type="bibr" rid="ref1">1</xref>]. A high intracuff ETT pressure may effectively seal the ETT cuff. However, a high intracuff pressure can damage the tracheal mucosa due to reduced perfusion pressure, and can result in post-extubation airway symptoms including sore throat, hoarseness, and dysphagia [<xref ref-type="bibr" rid="ref2">2</xref>-<xref ref-type="bibr" rid="ref4">4</xref>]. Therefore, an intracuff pressure of 20&#x2013;30 cmH<sub>2</sub>O and adjustment of intracuff pressure guided by objective measurement is normally recommended in order to prevent cuff-related complications [<xref ref-type="bibr" rid="ref5">5</xref>,<xref ref-type="bibr" rid="ref6">6</xref>].</p>
<p>The intracuff pressure is affected by many factors, such as head and neck positioning, material and type of the ETT cuff used, and the concomitant anesthetic gas [<xref ref-type="bibr" rid="ref7">7</xref>-<xref ref-type="bibr" rid="ref12">12</xref>]. Among these, nitrous oxide (N<sub>2</sub>O) diffuses into the ETT cuff, increasing the intracuff pressure and the risk of tracheal trauma [<xref ref-type="bibr" rid="ref7">7</xref>-<xref ref-type="bibr" rid="ref9">9</xref>]. An <italic>in vitro</italic> study reported differences in the intracuff pressure among five types of ETT cuffs during exposure to 66&#x0025; N<sub>2</sub>O [<xref ref-type="bibr" rid="ref9">9</xref>]. It showed that the time during which the intracuff pressure increased from 20 to 30 cmH<sub>2</sub>O varied depending on the cuff shape and material used. According to the manufacturer, the cylindrical cuff (Mallinckrodt&#8482; Hi-Lo tracheal tube, Covidien, Ireland) and tapered cuff (Mallinckrodt&#8482; TaperGuard tracheal tube, Covidien) are made of the same material, and have the same thickness. However, the intracuff pressure of the tapered cuff increased less than that of the cylindrical cuff during N<sub>2</sub>O exposure in simulation conditions [<xref ref-type="bibr" rid="ref13">13</xref>]. Furthermore, little is known clinically about the effect of a different ETT cuff shape on the intracuff pressure. If the intracuff pressure of the tapered cuff increased less than that of the cylindrical cuff during N<sub>2</sub>O exposure, the cuff shape would be a cause of the difference in intracuff pressure, and an ETT with a tapered cuff would be a good choice for tracheal intubation during general anesthesia using N<sub>2</sub>O.</p>
<p>This study aimed to evaluate whether the change in the intracuff pressure of the tapered cuff was different from the cylindrical cuff in patients undergoing general anesthesia using 60&#x0025; N<sub>2</sub>O.</p>
</sec>
<sec sec-type="materials|methods">
<title>MATERIALS AND METHODS</title>
<sec>
<title>Patients</title>
<p>This prospective, randomized, single-blind, parallel-group, clinical study was conducted between August 2014 and February 2015 and followed the CONSORT guidelines for clinical trials (<xref ref-type="fig" rid="F1">Fig. 1</xref>). The study protocol was approved by the Institutional Review Board (Protocol No.: 2013-23), and was registered at ClinicalTrials.gov (Identifier: NCT01812915).</p>
<fig id="F1">
<label>Fig. 1</label>
<caption>
<p>CONSORT flow chart.</p>
</caption>
<graphic xlink:href="APM_12_275_fig_1.tif"/>
</fig>
<p>After obtaining written informed consents, we enrolled 28 patients aged 18 to 70 years with American Society of Anesthesiologists physical status I, II, or III and body mass index &#x003C; 30 kg/m<sup>2</sup>, who were undergoing elective hand or forearm surgery under general anesthesia in supine with neutral head position. Exclusion criteria were presence of contraindications for N<sub>2</sub>O, airway-related or pulmonary diseases, difficult intubation, Cormack-Lehane grade &#x003E; 3, and an anesthetic time of &#x003C; 1 hour or &#x003E; 3 hours. The patients were randomly divided into two groups using sequentially numbered, opaque sealed envelopes containing the ETT details. The attending anesthesiologist was asked to pick up the envelope just before the anesthetic induction. Another researcher who was blinded to the group assignment was responsible for recording the intracuff pressure values. For each patient in Group C (n = 14), an ETT with a conventional cylindrical cuff was used; for those in Group T (n = 12), an ETT with a tapered cuff was used (<xref ref-type="fig" rid="F2">Fig. 2</xref>).</p>
<fig id="F2">
<label>Fig. 2</label>
<caption>
<p>Cuff shapes of endotracheal tubes. Upper cuff, the tapered cuff (MallinckrodtTM TaperGuard tracheal tube, Covidien, Ireland); lower cuff, the cylindrical cuff (MallinckrodtTM Hi-Lo tracheal tube, Covidien).</p>
</caption>
<graphic xlink:href="APM_12_275_fig_2.tif"/>
</fig>
</sec>
<sec>
<title>Anesthetic management</title>
<p>None of the patients received any premedication. Upon arrival in the operating room, the patients were monitored using electrocardiography, noninvasive blood pressure measurement, pulse oximetry, esophageal temperature probe, and capnography. After pre-oxygenation, general anesthesia was induced by administrating 2 mg/kg propofol and 1 &#x03BC;g/kg remifentanil, and muscle relaxation was achieved with 0.1 mg/kg vecuronium. Female patients were intubated using an ETT with 7.0 mm internal diameter, and male patients were intubated with a 7.5 mm internal diameter ETT. The ETT was secured at the right corner of the mouth. Anesthesia was maintained with sevoflurane at 2&#x2013;3 vol&#x0025; and a total fresh gas flow of 2 L/min (60&#x0025; N<sub>2</sub>O and 40&#x0025; oxygen). In previous studies [<xref ref-type="bibr" rid="ref14">14</xref>-<xref ref-type="bibr" rid="ref16">16</xref>], the N<sub>2</sub>O concentration varied between 50&#x0025; and 70&#x0025;; hence the middle value (60&#x0025;) was chosen for the present study. The patients were ventilated with a tidal volume of 6&#x2013;8 ml/kg and a respiratory rate of 10&#x2013;12 breaths/min to maintain an end-tidal CO<sub>2</sub> of 30&#x2013;34 mmHg, and a peak inspiratory pressure of less than 18 cmH<sub>2</sub>O during general anesthesia.</p>
</sec>
<sec>
<title>Outcome assessment</title>
<p>The pilot balloon of the ETT was connected to a manometer (VBM cuff pressure gauge, VBM Medizintechnik GmbH, Germany) using a 10 ml syringe via a 3-way stopcock. A syringe was used to inflate the ETT cuff with air until the intracuff pressure reached 20 cmH<sub>2</sub>O as the baseline. Measurements of the intracuff pressure were performed just before the start of 60&#x0025; N<sub>2</sub>O and every 10 minutes afterward until 60 minutes had elapsed. The intracuff pressure was recorded at the end of exhalation, the time at which the intracuff pressure was at its lowest during a ventilatory circle. After 60 minutes, the intracuff pressure was maintained at approximately 20 cmH<sub>2</sub>O until the end of anesthesia. N<sub>2</sub>O concentrations, obtained from the anesthesia gas module of GE Datex-Ohmeda Avance S/5&#8482; workstation, were recorded at the end of exhalation every 10 minutes. The incidences of sore throat, hoarseness, and dysphagia were assessed at 1, 6, and 24 hours postoperatively by one researcher who was not aware of the patient&#x2019;s group allocations. The number of patients using patient-controlled analgesia and the dose of bolus fentanyl administered just before the end of surgery were recorded.</p>
</sec>
<sec>
<title>Statistical analysis</title>
<p>The primary endpoint was the intracuff pressure after 60 minutes of 60&#x0025; N<sub>2</sub>O exposure. The secondary endpoints were the intracuff pressure at 10, 20, 30, 40, and 50 minutes after N<sub>2</sub>O exposure, and the incidence of postoperative sore throat, hoarseness, and dysphagia.</p>
<p>The sample size of 12 patients per group was estimated to detect an intracuff pressure difference of 10 cmH<sub>2</sub>O between Groups C and T, with an assumed standard deviation within a group of 7 cmH<sub>2</sub>O [<xref ref-type="bibr" rid="ref17">17</xref>]. The type 1 error was set at 0.05, and the power at 0.9. Twenty-eight patients were allocated to account for dropout. The sample size was calculated using G&#x002A;Power 3 (Heinrich-Heine University, Germany) [<xref ref-type="bibr" rid="ref18">18</xref>].</p>
<p>As per the results of the Shapiro-Wilk test, age, height, end-tidal N<sub>2</sub>O concentration at each time point, and the intracuff pressure after 60 minutes of N<sub>2</sub>O exposure were compared using an independent <italic>t</italic>-test. Weight, body temperature, anesthetic time, and the dose of fentanyl were compared using the Mann-Whitney <italic>U</italic> test. Differences in the number of males and females allocated to the two groups were compared using the Chi-square test, whereas the incidences of sore throat, hoarseness, and dysphagia were analyzed using Fisher&#x2019;s exact test. Statistical analysis was performed using SAS (Version 9.3, SAS Inc., USA).</p>
</sec>
</sec>
<sec sec-type="results">
<title>RESULTS</title>
<p>In the two groups, the distribution of sex, height, weight, body temperature, anesthetic time, patient-controlled analgesia, and the dose of bolus fentanyl was similar, whereas age showed a difference in distribution (<xref ref-type="table" rid="T1">Table 1</xref>).</p>
<table-wrap orientation="portrait" id="T1" position="float">
<label>Table 1</label>
<caption><p>Patient Characteristics</p></caption>
<table frame="hsides" rules="groups">
<thead>
<tr>
<th rowspan="2" align="center"></th>
<th align="center">Group C</th>
<th align="center">Group T</th>
<th align="center" rowspan="2">&#x2003;P value&#x2003;</th>
</tr>
<tr>
<th align="center">(n = 14)</th>
<th align="center">(n = 12)</th>
</tr>
</thead>
<tbody>
<tr>
<td align="left">Sex (M/F)</td>
<td align="center">5/9</td>
<td align="center">5/7</td>
<td align="center">1.000</td>
</tr>
<tr>
<td align="left">Age (yr)</td>
<td align="center">53 &#x00B1; 9</td>
<td align="center">43 &#x00B1; 14</td>
<td align="center">0.045</td>
</tr>
<tr>
<td align="left">Height (cm)</td>
<td align="center">162 &#x00B1; 10</td>
<td align="center">162 &#x00B1; 10</td>
<td align="center">0.988</td>
</tr>
<tr>
<td align="left">Weight (kg)</td>
<td align="center">67 (61&#x2013;70)</td>
<td align="center">59 (55&#x2013;67)</td>
<td align="center">0.246</td>
</tr>
<tr>
<td align="left">Body temperature (&#176;C)&#x2003;</td>
<td align="center">&#x2003;36.6 (36.6&#x2013;36.8)&#x2003;</td>
<td align="center">&#x2003;36.6 (36.4&#x2013;36.8)&#x2003;</td>
<td align="center">0.559</td>
</tr>
<tr>
<td align="left">Anesthetic time (min)</td>
<td align="center">100 (83&#x2013;122)</td>
<td align="center">98 (84&#x2013;116)</td>
<td align="center">0.777</td>
</tr>
<tr>
<td align="left">PCA (&#x0025;)</td>
<td align="center">5 (35.7&#x0025;)</td>
<td align="center">6 (50&#x0025;)</td>
<td align="center">0.736</td>
</tr>
<tr>
<td align="left">Fentanyl (&#956;g)</td>
<td align="center">0 (0&#x2013;50)</td>
<td align="center">25 (0&#x2013;100)</td>
<td align="center">0.382</td>
</tr>
</tbody>
</table>
<table-wrap-foot>
<fn>
<p>Data are presented as mean &#x00B1; SD or median (quantile) except for sex and PCA. Group C: Hi-Lo&#8482; endotracheal tube with a cylindrical cuff (Covidien, Ireland) was used. Group T: TaperGuard&#8482; endotracheal tube with a tapered cuff (Covidien) was used. PCA: patientcontrolled analgesia.</p>
</fn>
</table-wrap-foot>
</table-wrap>
<p>The intracuff pressure at 60 minutes was 40 cmH<sub>2</sub>O in Group C (95&#x0025; CI, 36&#x2013;44) and 40 cmH<sub>2</sub>O in Group T (95&#x0025; CI, 35&#x2013;45, P = 0.895) (<xref ref-type="fig" rid="F3">Fig. 3</xref>); the difference between the two groups was 0 cmH<sub>2</sub>O (95&#x0025; CI, &#x2212;6&#x2013;5). The lower limit of 95&#x0025; CI for the intracuff pressures exceeded 30 cmH<sub>2</sub>O at 60 minutes in both groups.</p>
<fig id="F3">
<label>Fig. 3</label>
<caption>
<p>Changes in the intracuff pressures of the endotracheal tubes during general anesthesia using 60&#x0025; nitrous oxide. There is no significant difference between the cylindrical cuff (MallinckrodtTM Hi-Lo tracheal tube, Covidien, Ireland) and the tapered cuff (MallinckrodtTM TaperGuard tracheal tube, Covidien) after 60 minutes of nitrous oxide exposure during general anesthesia (P = 0.895). The dots represent the mean and the vertical bars indicate the standard error of the mean at each time point. The gray band shows the clinically acceptable intracuff pressure.</p>
</caption>
<graphic xlink:href="APM_12_275_fig_3.tif"/>
</fig>
<p>There were no significant differences in the incidence of postoperative sore throat at 1 (Group C vs. Group T, 2 vs. 1; P = 1.000), 6 (2 vs. 0, P = 0.483), and 24 hours (3 vs. 0; P = 0.225). No patients reported hoarseness or dysphagia. The N<sub>2</sub>O concentrations in Group C were not different from that in Group T at each time point (<xref ref-type="fig" rid="F4">Fig. 4</xref>).</p>
<fig id="F4">
<label>Fig. 4</label>
<caption>
<p>Changes of nitrous oxide concentrations during general anesthesia. There is no significant difference of nitrous oxide concentration between the cylindrical cuff (MallinckrodtTM Hi-Lo tracheal tube, Covidien, Ireland) and the tapered cuff (MallinckrodtTM TaperGuard tracheal tube, Covidien) for 60 minutes. The dots represent the mean and the vertical bars indicate the standard error of the mean at each time point.</p>
</caption>
<graphic xlink:href="APM_12_275_fig_4.tif"/>
</fig>
</sec>
<sec sec-type="discussion">
<title>DISCUSSION</title>
<p>This study showed that the intracuff pressure of the ETT did not differ between the cylindrical cuff and the tapered cuffs after 60 minutes of N<sub>2</sub>O exposure during general anesthesia (P = 0.895). Furthermore, this result was confirmed by the confidence limit (6 cmH<sub>2</sub>O), which was less than the difference we had expected (10 cmH<sub>2</sub>O). The intracuff pressure was, therefore, not affected by the cuff shape. Considering the 95&#x0025; lower confidence limit in intracuff pressure (36 cmH<sub>2</sub>O in Group C and 35 cmH<sub>2</sub>O in Group T) at 60 minutes, it is reasonable to assume that the intracuff pressure increased more than 30 cmH<sub>2</sub>O (the upper limit of clinically acceptable intracuff pressure) before 60 minutes had elapsed. Therefore, continuous or frequent monitoring is recommended even if the duration of N<sub>2</sub>O exposure is less than 1 hour.</p>
<p>The rate of N<sub>2</sub>O diffusion into the cuff is affected by many factors, including the partial pressure gradient of N<sub>2</sub>O inside and outside the cuff, the area that is exposed to N<sub>2</sub>O, the diffusion time, and the cuff thickness [<xref ref-type="bibr" rid="ref19">19</xref>]. According to the manufacturer, the cylindrical and tapered cuffs are manufactured using the same material, and has the same thickness; thus, the surface area available for N<sub>2</sub>O diffusion plays an important role in the increase in intracuff pressure. The surface area may differ depending on the degree of the longitudinal folds in the cuff membrane.</p>
<p>The intracuff pressure in this study seems to be lower than that of a previously published simulation study [<xref ref-type="bibr" rid="ref13">13</xref>]. The human trachea may not be as rigid as the model trachea; thus, we predict that the human tracheal wall relieves some of the increase in the intracuff pressure. In addition, mucosal secretions may coat the cuff and seal the cuff folds, resulting in a decrease in the area available for N<sub>2</sub>O diffusion into the cylindrical cuff. This may be the one reason why the intracuff pressure did not differ between cuffs, although the cylindrical cuff was more folded when inflated.</p>
<p>This study does have some limitations. First, we specified the primary outcome analysis prior to initiating the study, on the basis of the independent two sample <italic>t</italic>-test of the intracuff pressure at 60 minutes of N<sub>2</sub>O exposure. However, considering that the data demonstrated a linear increase in the intracuff pressures in a time-dependent manner, alternative methods of statistical analysis may be available to further test these data. Second, considering an anesthetic circuit volume and the patient&#x2019;s functional residual volume, higher flow rates could have raised the concentration of N<sub>2</sub>O in the lungs more rapidly, hence intracuff pressure changes would have occurred more rapidly. It might have affected the differences in the intracuff pressure resulting from the cuff shape. However, the N<sub>2</sub>O concentrations in both the groups were not different at each time point (<xref ref-type="fig" rid="F4">Fig. 4</xref>), and the primary endpoint was the intracuff pressure at 60 minutes after the initiation of 60&#x0025; N<sub>2</sub>O; hence, we assumed that the effects of the flow rate on the intracuff pressure was insignificant. Lastly, although there were no significant differences in the incidence of postoperative sore throat, it may not be clinically meaningful because the sample size was too small to evaluate the incidence of sore throat properly.</p>
<p>In summary, the intracuff pressure of the TaperGuard&#8482; ETT was not different from that of the Hi-Lo&#8482; ETT after 60 minutes of 60&#x0025; N<sub>2</sub>O exposure during general anesthesia. The intracuff pressure can exceed 30 cmH<sub>2</sub>O within an hour; hence, continuous or frequent monitoring is recommended regardless of the duration of 60&#x0025; N<sub>2</sub>O exposure. Additionally, if a lower or higher concentration of N<sub>2</sub>O is used, the increase in intracuff pressure may be slower or faster, respectively, compared to 60&#x0025; N<sub>2</sub>O.</p>
</sec>
</body>
<back>
<ref-list>
<title>REFERENCES</title>
<ref id="ref1">
<label>1</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Priebe</surname>
<given-names>HJ</given-names>
</name>
</person-group>
<article-title>Could &#x201C;safe practice&#x201D; be compromising safe practice&#x003F; Should anesthetists have to deflate the cuff of the endotracheal tube before extubation&#x003F;</article-title>
<source>Minerva Anestesiol</source>
<year>2016</year>
<volume>82</volume>
<fpage>236</fpage>
<lpage>9</lpage>
<pub-id pub-id-type="pmid">26126979</pub-id>
</element-citation>
</ref>
<ref id="ref2">
<label>2</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Combes</surname>
<given-names>X</given-names>
</name>
<name>
<surname>Schauvliege</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Peyrouset</surname>
<given-names>O</given-names>
</name>
<name>
<surname>Motamed</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Kirov</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Dhonneur</surname>
<given-names>G</given-names>
</name>
<etal/>
</person-group>
<article-title>Intracuff pressure and tracheal morbidity: influence of filling with saline during nitrous oxide anesthesia</article-title>
<source>Anesthesiology</source>
<year>2001</year>
<volume>95</volume>
<fpage>1120</fpage>
<lpage>4</lpage>
<pub-id pub-id-type="doi">10.1097/00000542-200111000-00015</pub-id>
<pub-id pub-id-type="pmid">11684980</pub-id>
</element-citation>
</ref>
<ref id="ref3">
<label>3</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dobrin</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Canfield</surname>
<given-names>T</given-names>
</name>
</person-group>
<article-title>Cuffed endotracheal tubes: mucosal pressures and tracheal wall blood flow</article-title>
<source>Am J Surg</source>
<year>1977</year>
<volume>133</volume>
<fpage>562</fpage>
<lpage>8</lpage>
<pub-id pub-id-type="doi">10.1016/0002-9610(77)90008-3</pub-id>
</element-citation>
</ref>
<ref id="ref4">
<label>4</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Seegobin</surname>
<given-names>RD</given-names>
</name>
<name>
<surname>van Hasselt</surname>
<given-names>GL</given-names>
</name>
</person-group>
<article-title>Endotracheal cuff pressure and tracheal mucosal blood flow: endoscopic study of effects of four large volume cuffs</article-title>
<source>Br Med J (Clin Res Ed)</source>
<year>1984</year>
<volume>288</volume>
<fpage>965</fpage>
<lpage>8</lpage>
<pub-id pub-id-type="doi">10.1136/bmj.288.6422.965</pub-id>
</element-citation>
</ref>
<ref id="ref5">
<label>5</label>
<element-citation publication-type="journal">
<collab>American Thoracic Society Infectious Diseases Society of America</collab>
<article-title>Guidelines for the management of adults with hospital-acquired, ventilator-associated, and healthcare-associated pneumonia</article-title>
<source>Am J Respir Crit Care Med</source>
<year>2005</year>
<volume>171</volume>
<fpage>388</fpage>
<lpage>416</lpage>
<pub-id pub-id-type="doi">10.1164/rccm.200405-644ST</pub-id>
<pub-id pub-id-type="pmid">15699079</pub-id>
</element-citation>
</ref>
<ref id="ref6">
<label>6</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hockey</surname>
<given-names>CA</given-names>
</name>
<name>
<surname>van Zundert</surname>
<given-names>AA</given-names>
</name>
<name>
<surname>Paratz</surname>
<given-names>JD</given-names>
</name>
</person-group>
<article-title>Does objective measurement of tracheal tube cuff pressures minimise adverse effects and maintain accurate cuff pressures&#x003F; A systematic review and meta-analysis</article-title>
<source>Anaesth Intensive Care</source>
<year>2016</year>
<volume>44</volume>
<fpage>560</fpage>
<lpage>70</lpage>
<pub-id pub-id-type="pmid">27608338</pub-id>
</element-citation>
</ref>
<ref id="ref7">
<label>7</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Stanley</surname>
<given-names>TH</given-names>
</name>
</person-group>
<article-title>Nitrous oxide and pressures and volumes of high- and low-pressure endotracheal-tube cuffs in intubated patients</article-title>
<source>Anesthesiology</source>
<year>1975</year>
<volume>42</volume>
<fpage>637</fpage>
<lpage>40</lpage>
<pub-id pub-id-type="doi">10.1097/00000542-197505000-00035</pub-id>
<pub-id pub-id-type="pmid">1130733</pub-id>
</element-citation>
</ref>
<ref id="ref8">
<label>8</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tu</surname>
<given-names>HN</given-names>
</name>
<name>
<surname>Saidi</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Leiutaud</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Bensaid</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Menival</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Duvaldestin</surname>
<given-names>P</given-names>
</name>
</person-group>
<article-title>Nitrous oxide increases endotracheal cuff pressure and the incidence of tracheal lesions in anesthetized patients</article-title>
<source>Anesth Analg</source>
<year>1999</year>
<volume>89</volume>
<fpage>187</fpage>
<lpage>90</lpage>
<pub-id pub-id-type="doi">10.1097/00000539-199907000-00033</pub-id>
</element-citation>
</ref>
<ref id="ref9">
<label>9</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dullenkopf</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Gerber</surname>
<given-names>AC</given-names>
</name>
<name>
<surname>Weiss</surname>
<given-names>M</given-names>
</name>
</person-group>
<article-title>Nitrous oxide diffusion into tracheal tube cuffs: comparison of five different tracheal tube cuffs</article-title>
<source>Acta Anaesthesiol Scand</source>
<year>2004</year>
<volume>48</volume>
<fpage>1180</fpage>
<lpage>4</lpage>
<pub-id pub-id-type="doi">10.1111/j.1399-6576.2004.00483.x</pub-id>
<pub-id pub-id-type="pmid">15352966</pub-id>
</element-citation>
</ref>
<ref id="ref10">
<label>10</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kako</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Krishna</surname>
<given-names>SG</given-names>
</name>
<name>
<surname>Ramesh</surname>
<given-names>AS</given-names>
</name>
<name>
<surname>Merz</surname>
<given-names>MN</given-names>
</name>
<name>
<surname>Elmaraghy</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Grischkan</surname>
<given-names>J</given-names>
</name>
<etal/>
</person-group>
<article-title>The relationship between head and neck position and endotracheal tube intracuff pressure in the pediatric population</article-title>
<source>Paediatr Anaesth</source>
<year>2014</year>
<volume>24</volume>
<fpage>316</fpage>
<lpage>21</lpage>
<pub-id pub-id-type="doi">10.1111/pan.12487</pub-id>
<pub-id pub-id-type="pmid">24238105</pub-id>
</element-citation>
</ref>
<ref id="ref11">
<label>11</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kim</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Jeon</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Son</surname>
<given-names>JS</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>JR</given-names>
</name>
<name>
<surname>Ko</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Lim</surname>
<given-names>H</given-names>
</name>
</person-group>
<article-title>The changes of endotracheal tube cuff pressure by the position changes from supine to prone and the flexion and extension of head</article-title>
<source>Korean J Anesthesiol</source>
<year>2015</year>
<volume>68</volume>
<fpage>27</fpage>
<lpage>31</lpage>
<pub-id pub-id-type="doi">10.4097/kjae.2015.68.1.27</pub-id>
<pub-id pub-id-type="pmid">25664152</pub-id>
<pub-id pub-id-type="pmcid">PMC4318861</pub-id>
</element-citation>
</ref>
<ref id="ref12">
<label>12</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kim</surname>
<given-names>HC</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>YH</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Oh</surname>
<given-names>EA</given-names>
</name>
<name>
<surname>Jeon</surname>
<given-names>YT</given-names>
</name>
<name>
<surname>Park</surname>
<given-names>HP</given-names>
</name>
</person-group>
<article-title>Comparison of the endotracheal tube cuff pressure between a tapered- versus a cylindrical-shaped cuff after changing from the supine to the lateral flank position</article-title>
<source>Can J Anaesth</source>
<year>2015</year>
<volume>62</volume>
<fpage>1063</fpage>
<lpage>70</lpage>
<pub-id pub-id-type="doi">10.1007/s12630-015-0394-z</pub-id>
<pub-id pub-id-type="pmid">25894912</pub-id>
</element-citation>
</ref>
<ref id="ref13">
<label>13</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tsuboi</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Miyashita</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Yamaguchi</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Yamamoto</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Sakamaki</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Goto</surname>
<given-names>T</given-names>
</name>
</person-group>
<article-title>The TaperGuard&#8482; endotracheal tube intracuff pressure increase is less than that of the Hi-Lo&#8482; tube during nitrous oxide exposure: a model trachea study</article-title>
<source>Anesth Analg</source>
<year>2013</year>
<volume>116</volume>
<fpage>609</fpage>
<lpage>12</lpage>
<pub-id pub-id-type="doi">10.1213/ANE.0b013e318279b399</pub-id>
<pub-id pub-id-type="pmid">23400983</pub-id>
</element-citation>
</ref>
<ref id="ref14">
<label>14</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hounsome</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Nicholson</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Greenhalgh</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Cook</surname>
<given-names>TM</given-names>
</name>
<name>
<surname>Smith</surname>
<given-names>AF</given-names>
</name>
<name>
<surname>Lewis</surname>
<given-names>SR</given-names>
</name>
</person-group>
<article-title>Nitrous oxide-based versus nitrous oxide-free general anaesthesia and accidental awareness during general anaesthesia in surgical patients</article-title>
<source>Cochrane Database Syst Rev</source>
<year>2016</year>
<volume>8</volume>
<fpage>CD011052</fpage>
<pub-id pub-id-type="doi">10.1002/14651858.CD011052.pub2</pub-id>
</element-citation>
</ref>
<ref id="ref15">
<label>15</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kim</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Oh</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Choi</surname>
<given-names>W</given-names>
</name>
<name>
<surname>Kwon</surname>
<given-names>YJ</given-names>
</name>
<name>
<surname>Ko</surname>
<given-names>S</given-names>
</name>
</person-group>
<article-title>The economic evaluation of nitrous oxide in sevoflurane anesthesia</article-title>
<source>Anesth Pain Med</source>
<year>2017</year>
<volume>12</volume>
<fpage>23</fpage>
<lpage>7</lpage>
<pub-id pub-id-type="doi">10.17085/apm.2017.12.1.23</pub-id>
</element-citation>
</ref>
<ref id="ref16">
<label>16</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Leslie</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Myles</surname>
<given-names>PS</given-names>
</name>
<name>
<surname>Kasza</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Forbes</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Peyton</surname>
<given-names>PJ</given-names>
</name>
<name>
<surname>Chan</surname>
<given-names>MT</given-names>
</name>
<etal/>
</person-group>
<article-title>Nitrous Oxide and Serious Long-term Morbidity and Mortality in the Evaluation of Nitrous Oxide in the Gas Mixture for Anaesthesia (ENIGMA)-II Trial</article-title>
<source>Anesthesiology</source>
<year>2015</year>
<volume>123</volume>
<fpage>1267</fpage>
<lpage>80</lpage>
<pub-id pub-id-type="doi">10.1097/ALN.0000000000000908</pub-id>
<pub-id pub-id-type="pmid">26501387</pub-id>
</element-citation>
</ref>
<ref id="ref17">
<label>17</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ahmad</surname>
<given-names>NL</given-names>
</name>
<name>
<surname>Norsidah</surname>
<given-names>AM</given-names>
</name>
</person-group>
<article-title>Change in endotracheal tube cuff pressure during nitrous oxide anaesthesia: a comparison between air and distilled water cuff inflation</article-title>
<source>Anaesth Intensive Care</source>
<year>2001</year>
<volume>29</volume>
<fpage>510</fpage>
<lpage>4</lpage>
<pub-id pub-id-type="pmid">11669433</pub-id>
</element-citation>
</ref>
<ref id="ref18">
<label>18</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Faul</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Erdfelder</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Lang</surname>
<given-names>AG</given-names>
</name>
<name>
<surname>Buchner</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>G&#42;Power 3: a flexible statistical power analysis program for the social, behavioral, and biomedical sciences</article-title>
<source>Behav Res Methods</source>
<year>2007</year>
<volume>39</volume>
<fpage>175</fpage>
<lpage>91</lpage>
<pub-id pub-id-type="doi">10.3758/BF03193146</pub-id>
<pub-id pub-id-type="pmid">17695343</pub-id>
</element-citation>
</ref>
<ref id="ref19">
<label>19</label>
<element-citation publication-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mehta</surname>
<given-names>S</given-names>
</name>
</person-group>
<article-title>Effects of nitrous oxide and oxygen on tracheal tube cuff gas volumes</article-title>
<source>Br J Anaesth</source>
<year>1981</year>
<volume>53</volume>
<fpage>1227</fpage>
<lpage>31</lpage>
<pub-id pub-id-type="doi">10.1093/bja/53.11.1227</pub-id>
<pub-id pub-id-type="pmid">7326169</pub-id>
</element-citation>
</ref>
</ref-list>
</back>
</article>