<?xml version="1.0"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD with MathML3 v1.2 20190208//EN" "JATS-archivearticle1-mathml3.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" article-type="research-article"><?properties open_access?><front><journal-meta><journal-id journal-id-type="nlm-ta">Ann Surg Treat Res</journal-id><journal-id journal-id-type="iso-abbrev">Ann Surg Treat Res</journal-id><journal-id journal-id-type="publisher-id">ASTR</journal-id><journal-title-group><journal-title>Annals of Surgical Treatment and Research</journal-title></journal-title-group><issn pub-type="ppub">2288-6575</issn><issn pub-type="epub">2288-6796</issn><publisher><publisher-name>The Korean Surgical Society</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="pmid">34136427</article-id><article-id pub-id-type="pmc">8176198</article-id><article-id pub-id-type="doi">10.4174/astr.2021.100.6.313</article-id><article-categories><subj-group subj-group-type="heading"><subject>Original Article</subject></subj-group></article-categories><title-group><article-title>Mammography with a fully automated breast volumetric software as a novel method for estimating the preoperative breast volume prior to mastectomy</article-title></title-group><contrib-group><contrib contrib-type="author"><contrib-id contrib-id-type="orcid" authenticated="true">https://orcid.org/0000-0002-5927-4909</contrib-id><name><surname>Kim</surname><given-names>Jin Sung</given-names></name><xref ref-type="aff" rid="A1-astr-100-313">1</xref></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid" authenticated="true">https://orcid.org/0000-0003-2503-7718</contrib-id><name><surname>Bae</surname><given-names>Kyoungkyg</given-names></name><xref ref-type="aff" rid="A2-astr-100-313">2</xref></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid" authenticated="true">https://orcid.org/0000-0001-8756-4287</contrib-id><name><surname>Lee</surname><given-names>Eun Ji</given-names></name><xref ref-type="aff" rid="A1-astr-100-313">1</xref></contrib><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid" authenticated="true">https://orcid.org/0000-0001-8933-1444</contrib-id><name><surname>Bang</surname><given-names>Minseo</given-names></name><xref ref-type="aff" rid="A2-astr-100-313">2</xref></contrib></contrib-group><aff id="A1-astr-100-313"><label>1</label>Department of Surgery, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, <country>Korea</country>.</aff><aff id="A2-astr-100-313"><label>2</label>Department of Radiology, Ulsan University Hospital, University of Ulsan College of Medicine, Ulsan, <country>Korea</country>.</aff><author-notes><corresp>Corresponding Author: Minseo Bang. Department of Radiology, Ulsan University Hospital, University of Ulsan College of Medicine, 877 Bangeojinsunhwando-ro, Dong-gu, Ulsan 44033, Korea. Tel: +82-52-250-7257, Fax: +82-52-230-1155, <email>bangms@uuh.ulsan.kr</email></corresp></author-notes><pub-date pub-type="ppub"><month>6</month><year>2021</year></pub-date><pub-date pub-type="epub"><day>01</day><month>6</month><year>2021</year></pub-date><volume>100</volume><issue>6</issue><fpage>313</fpage><lpage>319</lpage><history><date date-type="received"><day>27</day><month>1</month><year>2021</year></date><date date-type="rev-recd"><day>22</day><month>3</month><year>2021</year></date><date date-type="accepted"><day>09</day><month>4</month><year>2021</year></date></history><permissions><copyright-statement>Copyright &#xA9; 2021, the Korean Surgical Society</copyright-statement><copyright-year>2021</copyright-year><copyright-holder>The Korean Surgical Society</copyright-holder><license><ali:license_ref xmlns:ali="http://www.niso.org/schemas/ali/1.0/" specific-use="textmining" content-type="ccbynclicense">https://creativecommons.org/licenses/by-nc/4.0/</ali:license_ref><license-p>Annals of Surgical Treatment and Research is an Open Access Journal. All articles are distributed under the terms of the Creative Commons Attribution Non-Commercial License (<ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by-nc/4.0/">http://creativecommons.org/licenses/by-nc/4.0/</ext-link>) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p></license></permissions><abstract><sec><title>Purpose</title><p>Increasing interest in maintaining a positive body image following breast cancer surgery has become an important aspect of reconstruction surgery. Volume matching of the reconstructed breast to natural breasts is the most important consideration. This study aimed to explore the feasibility of using mammography with a fully automated breast volumetric software to measure the preoperative breast volume in patients with breast cancer.</p></sec><sec><title>Methods</title><p>We evaluated patients who underwent a total mastectomy between July 2016 and February 2021. The specimen volume following total mastectomy was compared with breast volume estimates using a fully automated volumetric software (Quantra ver. 2.1.1) and 4 other previously described mammography-based prediction methods. The association between the estimates and mastectomy specimen volume was assessed using Pearson correlation and Bland-Altman analysis.</p></sec><sec><title>Results</title><p>Sixty-six patients were included. Compared with previously described mammography-based methods, Quantra estimates were more strongly correlated with mastectomy specimen volume in the entire, fatty, and dense breast groups (r = 0.920, 0.921, and 0.915, respectively; P &lt; 0.001). In applying Quantra estimates for measuring preoperative breast volume, we adjusted a simple equation: mastectomy specimen volume = Quantra estimate &#xD7; 0.8.</p></sec><sec><title>Conclusion</title><p>Mammography with a fully automated breast volumetric software can be useful for measuring preoperative breast volume in patients with breast cancer who undergo reconstruction surgery.</p></sec></abstract><kwd-group><kwd>Breast density</kwd><kwd>Breast neoplasms</kwd><kwd>Mammography</kwd><kwd>Mastectomy</kwd><kwd>Organ size</kwd><kwd>Software</kwd></kwd-group></article-meta></front><body><sec sec-type="intro"><title>INTRODUCTION</title><p>With increasing interest in maintaining a positive body image following breast cancer surgery, reconstruction surgery has become an important topic. To achieve balanced breast symmetry with reconstruction surgery, volume matching of the reconstructed breast to natural breasts is the most important consideration [<xref rid="B1-astr-100-313" ref-type="bibr">1</xref>]. As such, various methods including Archimedes' method, plastic casting, anthropomorphic measurements, use of a Grossman-Rounder cone, and 3-dimensional (3D) surface imaging techniques have been evaluated for breast volume measurement [<xref rid="B2-astr-100-313" ref-type="bibr">2</xref><xref rid="B3-astr-100-313" ref-type="bibr">3</xref><xref rid="B4-astr-100-313" ref-type="bibr">4</xref><xref rid="B5-astr-100-313" ref-type="bibr">5</xref><xref rid="B6-astr-100-313" ref-type="bibr">6</xref><xref rid="B7-astr-100-313" ref-type="bibr">7</xref><xref rid="B8-astr-100-313" ref-type="bibr">8</xref><xref rid="B9-astr-100-313" ref-type="bibr">9</xref>].</p><p>Another method that has been proposed for preoperative breast volume measurement is mammography [<xref rid="B10-astr-100-313" ref-type="bibr">10</xref><xref rid="B11-astr-100-313" ref-type="bibr">11</xref><xref rid="B12-astr-100-313" ref-type="bibr">12</xref><xref rid="B13-astr-100-313" ref-type="bibr">13</xref><xref rid="B14-astr-100-313" ref-type="bibr">14</xref>]. Because mammography is commonly used for breast cancer diagnosis, mammographic measurement is a readily available option for which no additional equipment is needed [<xref rid="B7-astr-100-313" ref-type="bibr">7</xref><xref rid="B10-astr-100-313" ref-type="bibr">10</xref>]. In most studies, volume measurement in mammography involved the use of geometric formulae to transform measurements into 3D breast shapes [<xref rid="B11-astr-100-313" ref-type="bibr">11</xref><xref rid="B12-astr-100-313" ref-type="bibr">12</xref><xref rid="B13-astr-100-313" ref-type="bibr">13</xref><xref rid="B14-astr-100-313" ref-type="bibr">14</xref>]. However, the applicability of this method is limited by observer subjectivity and inconsistencies in accuracy [<xref rid="B2-astr-100-313" ref-type="bibr">2</xref><xref rid="B3-astr-100-313" ref-type="bibr">3</xref><xref rid="B11-astr-100-313" ref-type="bibr">11</xref><xref rid="B12-astr-100-313" ref-type="bibr">12</xref><xref rid="B13-astr-100-313" ref-type="bibr">13</xref><xref rid="B14-astr-100-313" ref-type="bibr">14</xref><xref rid="B15-astr-100-313" ref-type="bibr">15</xref>].</p><p>A fully automated volumetric software has been developed for objective evaluation and control of interobserver variability in measuring breast density [<xref rid="B16-astr-100-313" ref-type="bibr">16</xref><xref rid="B17-astr-100-313" ref-type="bibr">17</xref><xref rid="B18-astr-100-313" ref-type="bibr">18</xref><xref rid="B19-astr-100-313" ref-type="bibr">19</xref>]. The software assesses the breast as a 3D structure and automatically quantifies the entire breast and fibroglandular volume and mammographic densities for both breasts [<xref rid="B19-astr-100-313" ref-type="bibr">19</xref>]. Previous studies involving a fully automated volumetric software have focused on evaluating the reliability of density measurements, comparisons of software-based versus visual assessments, and the usefulness of software as stratification tools in evaluating the risk of breast cancer [<xref rid="B16-astr-100-313" ref-type="bibr">16</xref><xref rid="B17-astr-100-313" ref-type="bibr">17</xref><xref rid="B18-astr-100-313" ref-type="bibr">18</xref><xref rid="B19-astr-100-313" ref-type="bibr">19</xref><xref rid="B20-astr-100-313" ref-type="bibr">20</xref><xref rid="B21-astr-100-313" ref-type="bibr">21</xref>]. However, to the best of our knowledge, no studies have evaluated entire breast volume data estimated using a fully automated volumetric software nor applied software in clinical practice for estimating breast volume.</p><p>Thus, this study aimed to explore the feasibility of using mammography with a fully automated breast volumetric software for measuring the preoperative breast volume in patients with breast cancer who undergo reconstruction surgery.</p></sec><sec sec-type="methods"><title>METHODS</title><sec><title>Study design and patients</title><p>This retrospective study was approved by Institutional Review Board of Ulsan University Hospital (No. UUH-2019-06-038) and was conducted according to the tenets of the Declaration of Helsinki and its later amendments. The requirement for informed consent was waived due to the retrospective nature of the study.</p><p>Participants underwent total mastectomy between July 2016 and February 2021 at Ulsan University Hospital in Ulsan, Korea. Patients were included if data from preoperative mammography analyzed with a fully automated volumetric software and specimen weight were available from the medical records. Male patients with breast cancer, patients with clinical T3 or T4 stage, those with incomplete medical records, those receiving neoadjuvant chemotherapy, and those experiencing recurrence at the time of surgery were excluded.</p><p>Throughout the study period, mammography was performed using a full-field digital mammography machine (Selenia Dimensions, Hologic, Bedford, MA, USA). Standard craniocaudal and mediolateral oblique views were routinely obtained.</p></sec><sec><title>Mammographic volume analysis by fully automated volumetric software</title><p>For fully automated volumetric analysis, we used Quantra version 2.1.1 (Hologic) from the raw full-filled digital mammography. The Quantra software is based on a verified method that accounts for imaging parameters used to acquire an image, such as kVp (kilovolt peak), mAs (milliampere-second), and characteristics of the filter and target materials [<xref rid="B22-astr-100-313" ref-type="bibr">22</xref>]. The software separates the breast region from the background to estimate tissue composition, including fatty and fibroglandular tissue, by computing X-ray attenuation. Following analysis on a pixel-by-pixel basis, the software aggregates single pixel values into an estimate volume of fibroglandular tissue and the breast provided in cubic centimeters [<xref rid="B19-astr-100-313" ref-type="bibr">19</xref>]. This process is performed separately for each breast; the final result includes a separate estimate for each breast and an average of both breasts. When Quantra processing was complete, processing data was displayed as Digital Imaging and Communications in Medicine (DICOM) capture images relaying the breast composition information (<xref ref-type="fig" rid="F1-astr-100-313">Fig. 1</xref>).</p></sec><sec><title>Mammographic volume measurement using an established equation</title><p>We searched related literature from the PubMed database and found 4 equations that used standard mammography (craniocaudal and mediolateral oblique view) for breast volume estimation.</p><p>(a) Breast volume = 1/3&#x3C0;R<sup>2</sup><sub>cc</sub>H<sub>cc</sub> [<xref rid="B11-astr-100-313" ref-type="bibr">11</xref>]</p><p>(b) Breast volume = 1/3&#x3C0;r<sup>2</sup><sub>mlo</sub>h<sub>mlo</sub> [<xref rid="B12-astr-100-313" ref-type="bibr">12</xref>]</p><p>(c) Breast volume = 1/3&#x3C0;R<sub>cc</sub>r<sub>mlo</sub>h<sub>mlo</sub> [<xref rid="B13-astr-100-313" ref-type="bibr">13</xref>]</p><p>All 3 of these equations assume that a breast on the craniocaudal or mediolateral oblique view approximates a cone shape.</p><p>(d) Breast volume = 1/4&#x3C0;H<sub>cc</sub>W<sub>cc</sub>C<sub>cc</sub> [<xref rid="B14-astr-100-313" ref-type="bibr">14</xref>]</p><p>This equation described by Kalbhen et al. [<xref rid="B14-astr-100-313" ref-type="bibr">14</xref>] is based on the shape of a compressed breast in the craniocaudal view, which is assumed to be a half-elliptic cylinder.</p><p>A breast radiologist (7 years of experience) blinded to the specimen weight measured H, R, and W on the craniocaudal view and r and h on the mediolateral oblique view of preoperative mammography. The C indicated the automatically measured values on the craniocaudal view of mammography. Representations of each of these measurements are shown in <xref ref-type="fig" rid="F2-astr-100-313">Fig. 2</xref>. In cases where measurements were difficult to confirm, a breast-imaging specialist with over 20 years of experience was consulted.</p></sec><sec><title>Surgical procedure</title><p>In this study, only patients with total mastectomy, excluding skin-sparing or nipple-sparing mastectomy, were included. For the total mastectomy, transverse or oblique elliptical incision was performed on the skin around the nipple. The extent of the mastectomy was to dissect from the medial side to the lateral border of the sternum, from the upper side to the lower side of the clavicle, from the lower side to the inframammary fold, and from the lateral side to the mid axillar line. Furthermore, axilla lymph node dissection was performed for sentinel lymph node biopsy or for axilla lymph node. Even where the axilla lymph node dissection was performed en bloc, the specimen weight was measured excluding the axilla lymph node and soft tissue.</p></sec><sec><title>Standard reference</title><p>Quantra- and mammography-based estimates are expressed as volumes; therefore, we used volume for comparisons throughout this study. However, volume information was not provided in the patients' medical records due to our hospital's standard practice of recording only the weight of the specimen during surgery. Thus, volume was calculated based on mammographic density (&#x3C1;) using the following equation: breast volume = breast weight/&#x3C1; (&#x3C1; = 0.916 g/mL for pattern A, &#x3C1; = 0.944 g/mL for pattern B, &#x3C1; = 0.972 g/mL for pattern C, and &#x3C1; = 1.0 g/mL for pattern D) [<xref rid="B14-astr-100-313" ref-type="bibr">14</xref>]. The patterns were set to account for the variability in breast tissue composition including differences in water and fat density between patients [<xref rid="B17-astr-100-313" ref-type="bibr">17</xref>]. Mammographic density was determined according to the percentage volumetric breast density in the report of Quantra analysis: pattern A, &lt;5.4%; pattern B, &lt;11.5%; pattern C, &lt;27.9%; and pattern D, &#x2265;27.9%.</p></sec><sec><title>Statistical analysis</title><p>Pearson correlation analysis was performed to assess the degree of linear association in breast volume measurement methods and specimen volume. Linear regression analysis was used for adjusting Quantra estimates to derive a mathematical formula. Bland-Altman analysis was performed to assess agreement between adjusted Quantra estimates and specimen volume. The 95% limit of agreement was formed using the mean difference in volume &#xB1; 1.96 standard deviation (SD) of the difference in volumes. Fixed and proportional bias was assessed using the 95% confidence interval for the mean difference. All statistical analyses were performed using IBM SPSS Statistics ver. 21.0 (IBM Corp., Armonk, NY, USA). A P-value of &lt;0.05 was considered statistically significant.</p></sec></sec><sec sec-type="results"><title>RESULTS</title><p>A total of 66 patients were included in this study. The mean age was 63.9 years (range, 45&#x2013;87 years), and the mean body mass index was 23.92 kg/m<sup>2</sup> (range, 17.91&#x2013;31.68 kg/m<sup>2</sup>). Tumor presentation types of mammography were as follows: calcification only in 14 patients, mass only in 35 patients, and both mass and calcification in 17 patients. Mammographic density patterns were fatty breast (A or B) in 23 patients and dense breast (C or D) in 43 patients. The clinical T stage was 0 in 7 patients, 1 in 30 patients, and 2 in 29 patients. All patients had unilateral breast cancer (right side, 40 patients and left side, 26 patients). The mean specimen weight was 421.22 g (range, 96&#x2013;830 g). The mean specimen volume calculated from weight and adjusted density, used as a standard reference, was 438.83 cm<sup>3</sup> (range, 98.70&#x2013;879.23 cm<sup>3</sup>).</p><p><xref rid="T1-astr-100-313" ref-type="table">Table 1</xref> shows the estimated volume from Quantra and 4 other conventional mammography-based prediction methods. There was a strong correlation between specimen volume and breast volume calculated using Quantra: r = 0.920 for the entire breast group, r = 0.921 in the fatty breast group, and r = 0.915 in the dense breast group. Compared to conventional mammographic methods, Quantra-based estimates had a stronger correlation with the specimen volume of the entire, fatty, and dense breast groups (<xref rid="T2-astr-100-313" ref-type="table">Table 2</xref>). However, both Quantra- and other mammography-based prediction methods tended to overestimate the mastectomy specimen volume.</p><p>For the application of Quantra-based estimates in measuring preoperative breast volume, we adjusted a simple equation using linear regression analysis: mastectomy specimen volume = Quantra-based estimate &#xD7; 0.8. There was also a strong correlation between specimen volume and adjusted Quantra-based estimates: r = 0.920 for the entire breast group, r = 0.921 in the fatty breast group, and r = 0.915 in the dense breast group (<xref rid="T2-astr-100-313" ref-type="table">Table 2</xref>). Bland-Altman scatter plots show that the difference between mastectomy specimen volume and adjusted Quantra-based estimates remained acceptable (mean &#xB1; 1.96 SD), indicating high reliability for the prediction of preoperative breast volume. There was no proportional or fixed bias (<xref ref-type="fig" rid="F3-astr-100-313">Fig. 3</xref>). An example of how adjusted Quantra-based estimates were applied to the patient is provided in <xref ref-type="fig" rid="F4-astr-100-313">Fig. 4</xref>.</p></sec><sec sec-type="discussion"><title>DISCUSSION</title><p>This study investigated the feasibility of using breast mammography combined with a fully automated breast volumetric software for measuring preoperative breast volume. Compared to estimates using conventional mammography-based calculations, Quantra-based estimates obtained in this study correlated more strongly with mastectomy specimen volume. However, there was a tendency to overestimate the mastectomy specimen volume, which had to be adjusted for and then applied to measure the preoperative breast volume. To predict breast volume from raw data of Quantra, we used the following formula; adjusted Quantra-based estimates = Quantra-based estimates &#xD7; 0.8.</p><p>In this study, a fully automated beast volumetric software for preoperative measurements tended to overestimate the actual breast volume, which can be explained by the fact that the tissue captured by mammography did not completely match the tissue removed during mastectomy. All breast tissue should be removed in total mastectomy; however, some parts of the skin, subcutaneous fat, and axillae are left for postoperative skin closure and cosmesis. In addition, before the operation, the breast also contains blood, water, and secretions such as milk, that are removed during resection, reducing the overall weight [<xref rid="B23-astr-100-313" ref-type="bibr">23</xref><xref rid="B24-astr-100-313" ref-type="bibr">24</xref>]. Thus, the estimates derived from Quantra should be adjusted so that they can be applied to reconstructive surgery.</p><p>Quantra-based estimates better correlated with mastectomy specimen volume than previously described mammography-based calculation estimates. Quantra segments the breast region from the background of mammography and uses volumetric values to derive information about the X-ray attenuation properties of the column of breast tissue above that pixel. Thus, Quantra-based calculations may be more accurate than previously described mammography-based calculation methods that are derived under the assumption that the breast is either a cone or half-elliptical cylinder shape to transform 2-dimensional measurements made from the mammography into 3D shapes [<xref rid="B11-astr-100-313" ref-type="bibr">11</xref><xref rid="B12-astr-100-313" ref-type="bibr">12</xref><xref rid="B13-astr-100-313" ref-type="bibr">13</xref><xref rid="B14-astr-100-313" ref-type="bibr">14</xref><xref rid="B18-astr-100-313" ref-type="bibr">18</xref><xref rid="B19-astr-100-313" ref-type="bibr">19</xref>].</p><p>Among the previously described mammography-based calculation methods, the formula of Kalbhen et al. [<xref rid="B14-astr-100-313" ref-type="bibr">14</xref>] (breast volume = 1/4&#x3C0;H<sub>cc</sub>W<sub>cc</sub>C<sub>cc</sub>) yielded results most closely correlated with breast specimen volumes. With the development of the mammography machine, breast compressions are now performed at a higher pressure, which violates the assumption of the cone shape, creating conditions more suitable for the half-elliptical cylinder shape assumption considered by Kalbhen et al. [<xref rid="B2-astr-100-313" ref-type="bibr">2</xref><xref rid="B14-astr-100-313" ref-type="bibr">14</xref>]. Several studies have investigated the most suitable equation for calculating the breast volume by mammography [<xref rid="B2-astr-100-313" ref-type="bibr">2</xref><xref rid="B11-astr-100-313" ref-type="bibr">11</xref><xref rid="B12-astr-100-313" ref-type="bibr">12</xref><xref rid="B13-astr-100-313" ref-type="bibr">13</xref><xref rid="B14-astr-100-313" ref-type="bibr">14</xref><xref rid="B15-astr-100-313" ref-type="bibr">15</xref>], but the results have differed among them mainly due to the differences in the size and density of target breasts by race. The optimal method that yields measurements similar to the actual volume is still controversial.</p><p>In reconstructive and aesthetic breast surgery, accurate volume estimation is an important component of preoperative planning for achieving breast symmetry and cosmesis outcome. Most classic methods such as Archimedes' method, plastic casting, and anthropomorphic measurements have been unreliable, difficult to execute, and lacked practicability [<xref rid="B2-astr-100-313" ref-type="bibr">2</xref><xref rid="B3-astr-100-313" ref-type="bibr">3</xref><xref rid="B7-astr-100-313" ref-type="bibr">7</xref>]. Preoperative MRI is known to be a relatively accurate and reproducible method to measure breast volume [<xref rid="B2-astr-100-313" ref-type="bibr">2</xref>]. MRI is a 3D imaging modality; however, it does not provide precise information regarding breast shape that can occur with conditions, such as ptosis, because MRI requires patients to be examined lying face down. The volumetric software mentioned in previous studies using MRI was reported to be diverse and unstandardized [<xref rid="B25-astr-100-313" ref-type="bibr">25</xref><xref rid="B26-astr-100-313" ref-type="bibr">26</xref><xref rid="B27-astr-100-313" ref-type="bibr">27</xref>]. Additionally, MRI techniques and associated software require extensive effort because the inspector measures the volume by specifying the area directly for each slice of the image [<xref rid="B25-astr-100-313" ref-type="bibr">25</xref>]. 3D surface imaging modalities are a recently developed innovative method for estimating breast volume that is easy to use, reliable, fast, and portable [<xref rid="B4-astr-100-313" ref-type="bibr">4</xref><xref rid="B5-astr-100-313" ref-type="bibr">5</xref><xref rid="B6-astr-100-313" ref-type="bibr">6</xref><xref rid="B8-astr-100-313" ref-type="bibr">8</xref>]. However, this technique is costly, motion-sensitive, and cannot differentiate the posterior surface of the breast from the chest wall [<xref rid="B5-astr-100-313" ref-type="bibr">5</xref>].</p><p>A fully automated breast volumetric software has a relatively high degree of reproducibility and reliability [<xref rid="B16-astr-100-313" ref-type="bibr">16</xref><xref rid="B18-astr-100-313" ref-type="bibr">18</xref>]. Additionally, if data are extracted directly from a software-equipped mammography machine, the estimates can be obtained automatically without any additional effort required from the patient or treating physician. Nevertheless, this method has some drawbacks. The software is currently available only for digital mammography machines and is expensive [<xref rid="B19-astr-100-313" ref-type="bibr">19</xref>]. Further, the software does not provide information on breast appearances such as the shape, trunk width, or presence of ptosis.</p><p>Unfortunately, this was a small, single-center study. To improve the accuracy of the study, only patients who underwent total mastectomy were included. There are also several problems associated with using the specimen volume as a standard for comparison. We used the volume estimated based on the specimen weight and not the exact measured specimen volume. Additionally, as the specimens were obtained from patients with breast cancer, the specimen volume included the tumor volume. To reduce this difference, cases of T3 and T4 cancer were excluded from this study. However, if the tumor is large, the volume of the breast can be overestimated or underestimated even though it is a T2 tumor.</p><p>This study demonstrated the usefulness of Quantra for preoperative volume measurement by comparing it with previously described mammography-based estimates. A previous study showed that mammography-based methods might be more accurate than classic techniques including casting, Archimedes' method, anthropometry, or using the Grossman-Roudner device [<xref rid="B3-astr-100-313" ref-type="bibr">3</xref>]. Recently developed 3D surface imaging technology and MRI measurement software were not available in our lab; therefore comparisons to this technique were not possible. However, we compared the estimated volume from Quantra with the actual volume from the total mastectomy specimen and obtained meaningful results. This study did not aim to determine whether a fully automated breast volumetric software is the optimal method to predict preoperative breast volume, but rather to investigate whether mammography with a fully automated breast volumetric software could be another feasible method to predict preoperative breast volume.</p><p>In conclusion, the estimated breast volume from a fully automated breast volumetric software, although overestimated, was strongly correlated with the actual mastectomy specimen volume. Thus, using a fully automated breast volumetric software with mammography can be helpful for measuring the preoperative breast volume for patients with breast cancer who will undergo reconstruction surgery.</p></sec></body><back><ack><title>ACKNOWLEDGEMENTS</title><p>This study was performed using Quantra version 2.1.1 (Hologic, Bedford, MA, USA) provided by the National R&amp;D Program for Cancer Control, Ministry of Health &amp; Welfare, Republic of Korea(1520200) program.</p></ack><fn-group><fn fn-type="COI-statement"><p><bold>Conflict of Interest:</bold> No potential conflict of interest relevant to this article was reported.</p></fn><fn fn-type="con"><p><bold>Author Contribution:</bold>
<list list-type="simple"><list-item><p><bold>Conceptualization, Methodology, Project Administration:</bold> MB</p></list-item><list-item><p><bold>Formal Analysis:</bold> MB, JSK, EJL</p></list-item><list-item><p><bold>Investigation:</bold> JSK, KB</p></list-item><list-item><p><bold>Writing &#x2014; Original Draft:</bold> MB, JSK</p></list-item><list-item><p><bold>Writing &#x2014; Review &amp; Editing:</bold> KB, EJL</p></list-item></list>
</p></fn></fn-group><ref-list><ref id="B1-astr-100-313"><label>1</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Utsunomiya</surname><given-names>H</given-names></name><name><surname>Kusano</surname><given-names>T</given-names></name><name><surname>Sato</surname><given-names>N</given-names></name><name><surname>Yoshimoto</surname><given-names>S</given-names></name></person-group><article-title>Estimating implant volume and mastectomy-specimen volume by measuring breast volume with a 3-dimensional scanner</article-title><source>Ann Plast Surg</source><year>2017</year><volume>79</volume><fpage>79</fpage><lpage>81</lpage><pub-id pub-id-type="pmid">28328637</pub-id></element-citation></ref><ref id="B2-astr-100-313"><label>2</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Choppin</surname><given-names>SB</given-names></name><name><surname>Wheat</surname><given-names>JS</given-names></name><name><surname>Gee</surname><given-names>M</given-names></name><name><surname>Goyal</surname><given-names>A</given-names></name></person-group><article-title>The accuracy of breast volume measurement methods: a systematic review</article-title><source>Breast</source><year>2016</year><volume>28</volume><fpage>121</fpage><lpage>129</lpage><pub-id pub-id-type="pmid">27288864</pub-id></element-citation></ref><ref id="B3-astr-100-313"><label>3</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kayar</surname><given-names>R</given-names></name><name><surname>Civelek</surname><given-names>S</given-names></name><name><surname>Cobanoglu</surname><given-names>M</given-names></name><name><surname>Gungor</surname><given-names>O</given-names></name><name><surname>Catal</surname><given-names>H</given-names></name><name><surname>Emiroglu</surname><given-names>M</given-names></name></person-group><article-title>Five methods of breast volume measurement: a comparative study of measurements of specimen volume in 30 mastectomy cases. </article-title><source>Breast Cancer (Auckl)</source><year>2011</year><volume>5</volume><fpage>43</fpage><lpage>52</lpage><pub-id pub-id-type="pmid">21494401</pub-id></element-citation></ref><ref id="B4-astr-100-313"><label>4</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kovacs</surname><given-names>L</given-names></name><name><surname>Eder</surname><given-names>M</given-names></name><name><surname>Hol lweck</surname><given-names>R</given-names></name><name><surname>Zimmermann</surname><given-names>A</given-names></name><name><surname>Settles</surname><given-names>M</given-names></name><name><surname>Schneider</surname><given-names>A</given-names></name><etal/></person-group><article-title>Comparison between breast volume measurement using 3D surface imaging and classical techniques</article-title><source>Breast</source><year>2007</year><volume>16</volume><fpage>137</fpage><lpage>145</lpage><pub-id pub-id-type="pmid">17029808</pub-id></element-citation></ref><ref id="B5-astr-100-313"><label>5</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Yip</surname><given-names>JM</given-names></name><name><surname>Mouratova</surname><given-names>N</given-names></name><name><surname>Jeffery</surname><given-names>RM</given-names></name><name><surname>Veitch</surname><given-names>DE</given-names></name><name><surname>Woodman</surname><given-names>RJ</given-names></name><name><surname>Dean</surname><given-names>NR</given-names></name></person-group><article-title>Accurate assessment of breast volume: a study comparing the volumetric gold standard (direct water displacement measurement of mastectomy specimen) with a 3D laser scanning technique</article-title><source>Ann Plast Surg</source><year>2012</year><volume>68</volume><fpage>135</fpage><lpage>141</lpage><pub-id pub-id-type="pmid">21587046</pub-id></element-citation></ref><ref id="B6-astr-100-313"><label>6</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Losken</surname><given-names>A</given-names></name><name><surname>Seify</surname><given-names>H</given-names></name><name><surname>Denson</surname><given-names>DD</given-names></name><name><surname>Paredes</surname><given-names>AA</given-names><suffix>Jr</suffix></name><name><surname>Carlson</surname><given-names>GW</given-names></name></person-group><article-title>Validating threedimensional imaging of the breast</article-title><source>Ann Plast Surg</source><year>2005</year><volume>54</volume><fpage>471</fpage><lpage>476</lpage><pub-id pub-id-type="pmid">15838205</pub-id></element-citation></ref><ref id="B7-astr-100-313"><label>7</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Bulstrode</surname><given-names>N</given-names></name><name><surname>Bellamy</surname><given-names>E</given-names></name><name><surname>Shrotria</surname><given-names>S</given-names></name></person-group><article-title>Breast volume assessment: comparing five different techniques</article-title><source>Breast</source><year>2001</year><volume>10</volume><fpage>117</fpage><lpage>123</lpage><pub-id pub-id-type="pmid">14965570</pub-id></element-citation></ref><ref id="B8-astr-100-313"><label>8</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Howes</surname><given-names>BH</given-names></name><name><surname>Watson</surname><given-names>DI</given-names></name><name><surname>Fosh</surname><given-names>B</given-names></name><name><surname>Dean</surname><given-names>NR</given-names></name></person-group><article-title>Efficacy of an external volume expansion device and autologous fat grafting for breast reconstruction following breast conserving surgery and total mastectomy: small improvements in quality of life found in a prospective cohort study</article-title><source>J Plast Reconstr Aesthet Surg</source><year>2020</year><volume>73</volume><fpage>27</fpage><lpage>35</lpage><pub-id pub-id-type="pmid">31495743</pub-id></element-citation></ref><ref id="B9-astr-100-313"><label>9</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chae</surname><given-names>MP</given-names></name><name><surname>Rozen</surname><given-names>WM</given-names></name><name><surname>Spychal</surname><given-names>RT</given-names></name><name><surname>Hunter-Smith</surname><given-names>DJ</given-names></name></person-group><article-title>Breast volumetric analysis for aesthetic planning in breast reconstruction: a literature review of techniques</article-title><source>Gland Surg</source><year>2016</year><volume>5</volume><fpage>212</fpage><lpage>226</lpage><pub-id pub-id-type="pmid">27047788</pub-id></element-citation></ref><ref id="B10-astr-100-313"><label>10</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Itsukage</surname><given-names>S</given-names></name><name><surname>Sowa</surname><given-names>Y</given-names></name><name><surname>Goto</surname><given-names>M</given-names></name><name><surname>Taguchi</surname><given-names>T</given-names></name><name><surname>Numajiri</surname><given-names>T</given-names></name></person-group><article-title>Breast volume measurement by recycling the data obtained from 2 routine modalities, mammography and magnetic resonance imaging</article-title><source>Eplasty</source><year>2017</year><volume>17</volume><elocation-id>e39</elocation-id><pub-id pub-id-type="pmid">29308107</pub-id></element-citation></ref><ref id="B11-astr-100-313"><label>11</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Katariya</surname><given-names>RN</given-names></name><name><surname>Forrest</surname><given-names>AP</given-names></name><name><surname>Gravelle</surname><given-names>IH</given-names></name></person-group><article-title>Breast volumes in cancer of the breast</article-title><source>Br J Cancer</source><year>1974</year><volume>29</volume><fpage>270</fpage><lpage>273</lpage><pub-id pub-id-type="pmid">4830145</pub-id></element-citation></ref><ref id="B12-astr-100-313"><label>12</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Cochrane</surname><given-names>RA</given-names></name><name><surname>Valasiadou</surname><given-names>P</given-names></name><name><surname>Wilson</surname><given-names>AR</given-names></name><name><surname>Al-Ghazal</surname><given-names>SK</given-names></name><name><surname>Macmillan</surname><given-names>RD</given-names></name></person-group><article-title>Cosmesis and satisfaction after breast-conserving surgery correlates with the percentage of breast volume excised</article-title><source>Br J Surg</source><year>2003</year><volume>90</volume><fpage>1505</fpage><lpage>1509</lpage><pub-id pub-id-type="pmid">14648728</pub-id></element-citation></ref><ref id="B13-astr-100-313"><label>13</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Fung</surname><given-names>JT</given-names></name><name><surname>Chan</surname><given-names>SW</given-names></name><name><surname>Chiu</surname><given-names>AN</given-names></name><name><surname>Cheung</surname><given-names>PS</given-names></name><name><surname>Lam</surname><given-names>SH</given-names></name></person-group><article-title>Mammographic determination of breast volume by elliptical cone estimation</article-title><source>World J Surg</source><year>2010</year><volume>34</volume><fpage>1442</fpage><lpage>1445</lpage><pub-id pub-id-type="pmid">20091167</pub-id></element-citation></ref><ref id="B14-astr-100-313"><label>14</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Kalbhen</surname><given-names>CL</given-names></name><name><surname>McGill</surname><given-names>JJ</given-names></name><name><surname>Fendley</surname><given-names>PM</given-names></name><name><surname>Corrigan</surname><given-names>KW</given-names></name><name><surname>Angelats</surname><given-names>J</given-names></name></person-group><article-title>Mammographic determinat ion of breast volume: comparing different methods</article-title><source>AJR Am J Roentgenol</source><year>1999</year><volume>173</volume><fpage>1643</fpage><lpage>1649</lpage><pub-id pub-id-type="pmid">10584814</pub-id></element-citation></ref><ref id="B15-astr-100-313"><label>15</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Hoe</surname><given-names>AL</given-names></name><name><surname>Mullee</surname><given-names>MA</given-names></name><name><surname>Royle</surname><given-names>GT</given-names></name><name><surname>Guyer</surname><given-names>PB</given-names></name><name><surname>Taylor</surname><given-names>I</given-names></name></person-group><article-title>Breast size and prognosis in early breast cancer</article-title><source>Ann R Coll Surg Engl</source><year>1993</year><volume>75</volume><fpage>18</fpage><lpage>22</lpage><pub-id pub-id-type="pmid">8422138</pub-id></element-citation></ref><ref id="B16-astr-100-313"><label>16</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Gweon</surname><given-names>HM</given-names></name><name><surname>Youk</surname><given-names>JH</given-names></name><name><surname>Kim</surname><given-names>JA</given-names></name><name><surname>Son</surname><given-names>EJ</given-names></name></person-group><article-title>Radiologist assessment of breast density by BI-RADS categories versus fully automated volumetric assessment</article-title><source>AJR Am J Roentgenol</source><year>2013</year><volume>201</volume><fpage>692</fpage><lpage>697</lpage><pub-id pub-id-type="pmid">23971465</pub-id></element-citation></ref><ref id="B17-astr-100-313"><label>17</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ciatto</surname><given-names>S</given-names></name><name><surname>Bernardi</surname><given-names>D</given-names></name><name><surname>Calabrese</surname><given-names>M</given-names></name><name><surname>Durando</surname><given-names>M</given-names></name><name><surname>Gentilini</surname><given-names>MA</given-names></name><name><surname>Mariscotti</surname><given-names>G</given-names></name><etal/></person-group><article-title>A first evaluation of breast radiological density assessment by QUANTRA software as compared to visual classification</article-title><source>Breast</source><year>2012</year><volume>21</volume><fpage>503</fpage><lpage>506</lpage><pub-id pub-id-type="pmid">22285387</pub-id></element-citation></ref><ref id="B18-astr-100-313"><label>18</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Youk</surname><given-names>JH</given-names></name><name><surname>Gweon</surname><given-names>HM</given-names></name><name><surname>Son</surname><given-names>EJ</given-names></name><name><surname>Kim</surname><given-names>JA</given-names></name></person-group><article-title>Automated volumetric breast density measurements in the era of the birads fifth edition: a comparison with visual assessment</article-title><source>AJR Am J Roentgenol</source><year>2016</year><volume>206</volume><fpage>1056</fpage><lpage>1062</lpage><pub-id pub-id-type="pmid">26934689</pub-id></element-citation></ref><ref id="B19-astr-100-313"><label>19</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Skippage</surname><given-names>P</given-names></name><name><surname>Wilkinson</surname><given-names>L</given-names></name><name><surname>Allen</surname><given-names>S</given-names></name><name><surname>Roche</surname><given-names>N</given-names></name><name><surname>Dowsett</surname><given-names>M</given-names></name><name><surname>A'hern</surname><given-names>R</given-names></name></person-group><article-title>Correlation of age and HRT use with breast density as assessed by Quantra&#x2122;</article-title><source>Breast J</source><year>2013</year><volume>19</volume><fpage>79</fpage><lpage>86</lpage><pub-id pub-id-type="pmid">23230974</pub-id></element-citation></ref><ref id="B20-astr-100-313"><label>20</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Alonzo-Proulx</surname><given-names>O</given-names></name><name><surname>Mawdsley</surname><given-names>GE</given-names></name><name><surname>Patrie</surname><given-names>JT</given-names></name><name><surname>Yaffe</surname><given-names>MJ</given-names></name><name><surname>Harvey</surname><given-names>JA</given-names></name></person-group><article-title>Reliability of automated breast density measurements</article-title><source>Radiology</source><year>2015</year><volume>275</volume><fpage>366</fpage><lpage>376</lpage><pub-id pub-id-type="pmid">25734553</pub-id></element-citation></ref><ref id="B21-astr-100-313"><label>21</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Rahbar</surname><given-names>K</given-names></name><name><surname>Gubern-Merida</surname><given-names>A</given-names></name><name><surname>Patrie</surname><given-names>JT</given-names></name><name><surname>Harvey</surname><given-names>JA</given-names></name></person-group><article-title>Automated volumetric mammographic breast density measurements may underestimate percent breast density for high-density breasts</article-title><source>Acad Radiol</source><year>2017</year><volume>24</volume><fpage>1561</fpage><lpage>1569</lpage><pub-id pub-id-type="pmid">28754209</pub-id></element-citation></ref><ref id="B22-astr-100-313"><label>22</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Boone</surname><given-names>JM</given-names></name><name><surname>Fewell</surname><given-names>TR</given-names></name><name><surname>Jennings</surname><given-names>RJ</given-names></name></person-group><article-title>Molybdenum, rhodium, and tungsten anode spectral models using interpolating polynomials with application to mammography</article-title><source>Med Phys</source><year>1997</year><volume>24</volume><fpage>1863</fpage><lpage>1874</lpage><pub-id pub-id-type="pmid">9434969</pub-id></element-citation></ref><ref id="B23-astr-100-313"><label>23</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Wilson</surname><given-names>CB</given-names></name><name><surname>Lammertsma</surname><given-names>AA</given-names></name><name><surname>McKenzie</surname><given-names>CG</given-names></name><name><surname>Sikora</surname><given-names>K</given-names></name><name><surname>Jones</surname><given-names>T</given-names></name></person-group><article-title>Measurements of blood flow and exchanging water space in breast tumors using positron emission tomography: a rapid and noninvasive dynamic method</article-title><source>Cancer Res</source><year>1992</year><volume>52</volume><fpage>1592</fpage><lpage>1597</lpage><pub-id pub-id-type="pmid">1540969</pub-id></element-citation></ref><ref id="B24-astr-100-313"><label>24</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Shaheed</surname><given-names>SU</given-names></name><name><surname>Tait</surname><given-names>C</given-names></name><name><surname>Kyriacou</surname><given-names>K</given-names></name><name><surname>Linforth</surname><given-names>R</given-names></name><name><surname>Salhab</surname><given-names>M</given-names></name><name><surname>Sutton</surname><given-names>C</given-names></name></person-group><article-title>Evaluation of nipple aspirate fluid as a diagnostic tool for early detection of breast cancer</article-title><source>Clin Proteomics</source><year>2018</year><volume>15</volume><elocation-id>3</elocation-id><pub-id pub-id-type="pmid">29344009</pub-id></element-citation></ref><ref id="B25-astr-100-313"><label>25</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Herold</surname><given-names>C</given-names></name><name><surname>Reichelt</surname><given-names>A</given-names></name><name><surname>Stieglitz</surname><given-names>LH</given-names></name><name><surname>Dettmer</surname><given-names>S</given-names></name><name><surname>Knobloch</surname><given-names>K</given-names></name><name><surname>Lotz</surname><given-names>J</given-names></name><etal/></person-group><article-title>MRI-based breast volumetry-evaluation of three different software solutions</article-title><source>J Digit Imaging</source><year>2010</year><volume>23</volume><fpage>603</fpage><lpage>610</lpage><pub-id pub-id-type="pmid">20066465</pub-id></element-citation></ref><ref id="B26-astr-100-313"><label>26</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Herly</surname><given-names>M</given-names></name><name><surname>M&#xFC;ller</surname><given-names>FC</given-names></name><name><surname>&#xD8;rholt</surname><given-names>M</given-names></name><name><surname>Hansen</surname><given-names>J</given-names></name><name><surname>Sv&#xE6;rke</surname><given-names>S</given-names></name><name><surname>Hemmingsen</surname><given-names>MN</given-names></name><etal/></person-group><article-title>The current gold standard breast volumetry technique seems to overestimate fat graft volume retention in the breast: a validation study</article-title><source>J Plast Reconstr Aesthet Surg</source><year>2019</year><volume>72</volume><fpage>1278</fpage><lpage>1284</lpage><pub-id pub-id-type="pmid">31029582</pub-id></element-citation></ref><ref id="B27-astr-100-313"><label>27</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Rha</surname><given-names>EY</given-names></name><name><surname>Choi</surname><given-names>IK</given-names></name><name><surname>Yoo</surname><given-names>G</given-names></name></person-group><article-title>Accuracy of the method for estimating breast volume on three-dimensional simulated magnetic resonance imaging scans in breast reconstruction</article-title><source>Plast Reconstr Surg</source><year>2014</year><volume>133</volume><fpage>14</fpage><lpage>20</lpage></element-citation></ref></ref-list></back><floats-group><fig id="F1-astr-100-313" orientation="portrait" position="float"><label>Fig. 1</label><caption><title>Quantra processing.</title></caption><graphic xlink:href="astr-100-313-g001"/></fig><fig id="F2-astr-100-313" orientation="portrait" position="float"><label>Fig. 2</label><caption><title>Sample mammography measurements in a 51-year-old woman with invasive ductal carcinoma. (A) Craniocaudal view shows representations of measurements. W = medial to lateral width, R = W/2, H = posterior to anterior height, perpendicular from the posterior film edge to the most anterior portion of the breast. (B) Mediolateral oblique view shows representations of measurements. w = superolateral to inferomedial width, measured as a distance from the most acute portion of axillary concavity to the inframammary fold; r = w/2; h = posterior to anterior height, perpendicular to the pectoralis muscle from the anterior border of the muscle to the most anterior portion of the breast.</title></caption><graphic xlink:href="astr-100-313-g002"/></fig><fig id="F3-astr-100-313" orientation="portrait" position="float"><label>Fig. 3</label><caption><title>Bland-Altman plot showing difference in adjusted Quantra estimates and mastectomy specimen volume. (A) Entire breast group, (B) fatty breast group, and (C) dense breast group.</title></caption><graphic xlink:href="astr-100-313-g003"/></fig><fig id="F4-astr-100-313" orientation="portrait" position="float"><label>Fig. 4</label><caption><title>Sample image for Quantra-based estimation of preoperative breast volume. A 57-year-old woman with invasive ductal carcinoma of the right breast underwent a total mastectomy. (A) Preoperatively, the patient underwent routine mammography with fully automated breast volumetric software (Quantra). (B) The Quantra- and adjusted Quantra-based breast volume was 571 cm<sup>3</sup> and 456.8 cm<sup>3</sup>, respectively. After total mastectomy, the weight of the actual mastectomy specimen was 460 g, and the converted specimen volume was 447.2 cm<sup>3</sup>.</title></caption><graphic xlink:href="astr-100-313-g004"/></fig><table-wrap id="T1-astr-100-313" orientation="portrait" position="float"><label>Table 1</label><caption><title>Breast volume estimates calculated using Quantra and conventional mammographic methods</title></caption><graphic xlink:href="astr-100-313-i001"/><table-wrap-foot><fn><p>Values are presented as mean (range).</p><p>Mean (range) of specimen weight is 421.22 g (96.0&#x2013;830.0 g) and specimen volume is 438.83 cm<sup>3</sup> (98.7&#x2013;879.23 cm<sup>3</sup>).</p><p><sup>a)</sup>Quantra-based estimates &#xD7; 0.8.</p></fn></table-wrap-foot></table-wrap><table-wrap id="T2-astr-100-313" orientation="portrait" position="float"><label>Table 2</label><caption><title>Pearson correlations of breast volume estimates calculated using Quantra- and mammography-based methods with specimen volume</title></caption><graphic xlink:href="astr-100-313-i002"/><table-wrap-foot><fn><p>A&#x2013;D, patterns of mammographic breast density.</p><p>P &lt; 0.001 for all.</p><p><sup>a)</sup>Quantra-based estimates &#xD7; 0.8.</p></fn></table-wrap-foot></table-wrap></floats-group></article>
