<?xml version="1.0"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Archiving and Interchange DTD with MathML3 v1.2 20190208//EN" "JATS-archivearticle1-mathml3.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="research-article"><?properties open_access?><front><journal-meta><journal-id journal-id-type="nlm-ta">Restor Dent Endod</journal-id><journal-id journal-id-type="iso-abbrev">Restor Dent Endod</journal-id><journal-id journal-id-type="publisher-id">RDE</journal-id><journal-title-group><journal-title>Restorative Dentistry &amp; Endodontics</journal-title></journal-title-group><issn pub-type="ppub">2234-7658</issn><issn pub-type="epub">2234-7666</issn><publisher><publisher-name>The Korean Academy of Conservative Dentistry</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="pmid">32483531</article-id><article-id pub-id-type="pmc">7239675</article-id><article-id pub-id-type="publisher-id">2020450505</article-id><article-id pub-id-type="doi">10.5395/rde.2020.45.e13</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group></article-categories><title-group><article-title>Influence of modeling agents on the surface properties of an esthetic nano-hybrid composite</article-title></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><contrib-id contrib-id-type="orcid" authenticated="true">https://orcid.org/0000-0003-0562-056X</contrib-id><name><surname>Kutuk</surname><given-names>Zeynep Bilge</given-names></name><xref ref-type="aff" rid="A1-rde-45-e13"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid" authenticated="true">https://orcid.org/0000-0003-4443-046X</contrib-id><name><surname>Erden</surname><given-names>Ecem</given-names></name><xref ref-type="aff" rid="A1-rde-45-e13"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid" authenticated="true">https://orcid.org/0000-0002-7778-8700</contrib-id><name><surname>Aksahin</surname><given-names>Damla Lara</given-names></name><xref ref-type="aff" rid="A1-rde-45-e13"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid" authenticated="true">https://orcid.org/0000-0003-3879-0856</contrib-id><name><surname>Durak</surname><given-names>Zeynep Elif</given-names></name><xref ref-type="aff" rid="A1-rde-45-e13"/></contrib><contrib contrib-type="author"><contrib-id contrib-id-type="orcid" authenticated="true">https://orcid.org/0000-0002-3559-5011</contrib-id><name><surname>Dulda</surname><given-names>Alp Can</given-names></name><xref ref-type="aff" rid="A1-rde-45-e13"/></contrib></contrib-group><aff id="A1-rde-45-e13">Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara, <country>Turkey</country>.</aff><author-notes><corresp>Correspondence to Zeynep Bilge Kutuk, DDS, PhD. Assistant Professor, Department of Restorative Dentistry, School of Dentistry, Hacettepe University, Ankara 06100, Turkey. <email>zeynepbilge.kutuk@hacettepe.edu.tr</email></corresp></author-notes><pub-date pub-type="collection"><month>5</month><year>2020</year></pub-date><pub-date pub-type="epub"><day>29</day><month>1</month><year>2020</year></pub-date><volume>45</volume><issue>2</issue><elocation-id>e13</elocation-id><history><date date-type="received"><day>28</day><month>9</month><year>2019</year></date><date date-type="rev-recd"><day>08</day><month>11</month><year>2019</year></date><date date-type="accepted"><day>13</day><month>11</month><year>2019</year></date></history><permissions><copyright-statement>Copyright &#xA9; 2020. The Korean Academy of Conservative Dentistry</copyright-statement><copyright-year>2020</copyright-year><copyright-holder>The Korean Academy of Conservative Dentistry</copyright-holder><license license-type="open-access" xlink:href="https://creativecommons.org/licenses/by-nc/4.0/"><license-p>This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (<ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by-nc/4.0/">https://creativecommons.org/licenses/by-nc/4.0/</ext-link>) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p></license></permissions><abstract><sec><title>Objective</title><p>The aim of this study was to evaluate the influence of different modeling agents on the surface microhardness (Vickers hardness number; VHN), roughness (Ra), and color change (&#x394;E) of a nano-hybrid composite with or without exposure to discoloration by coffee.</p></sec><sec><title>Materials and Methods</title><p>Sixty-four cylinder-shaped nano-hybrid composite specimens were prepared using a Teflon mold. The specimens' surfaces were prepared according to the following groups: group 1, no modeling agent; group 2, Modeling Liquid; group 3, a universal adhesive (G-Premio Bond); and group 4, the first step of a 2-step self-adhesive system (OptiBond XTR). Specimens were randomly allocated into 2 groups (<italic>n</italic> = 8) according to the storage medium (distilled water or coffee). VHN, Ra, and &#x394;E were measured at 24 hours, 1 week, and 6 weeks. The Kruskal-Wallis test followed by the Bonferroni correction for pairwise comparisons was used for statistical analysis (&#x3B1; = 0.05).</p></sec><sec><title>Results</title><p>Storage time did not influence the VHN of the nano-hybrid composite in any group (<italic>p</italic> &gt; 0.05). OptiBond XTR Primer application affected the VHN negatively in all investigated storage medium and time conditions (<italic>p</italic> &lt; 0.05). Modeling Liquid application yielded improved Ra values for the specimens stored in coffee at each time point (<italic>p</italic> &lt; 0.05). Modeling Liquid application was associated with the lowest &#x394;E values in all investigated storage medium and time conditions (<italic>p</italic> &lt; 0.05).</p></sec><sec><title>Conclusion</title><p>Different types of modeling agents could affect the surface properties and discoloration of nano-hybrid composites.</p></sec></abstract><kwd-group kwd-group-type="author"><kwd>Color change</kwd><kwd>Microhardness</kwd><kwd>Modeling agents</kwd><kwd>Nano-hybrid composite</kwd><kwd>Surface roughness</kwd></kwd-group></article-meta></front><body><sec sec-type="intro"><title>INTRODUCTION</title><p>Composites are currently the most commonly preferred direct restoratives, primarily as a result of improvements in adhesive technology in dentistry [<xref rid="B1-rde-45-e13" ref-type="bibr">1</xref>]. Composites can be used with a minimally invasive technique and provide optical characteristics similar to those of natural teeth; furthermore, composites are easy to handle and insert, facilitating sculpture of the dental anatomy [<xref rid="B2-rde-45-e13" ref-type="bibr">2</xref>]. Furthermore, layering of the composite is a common clinical technique used during the sculpting and placement of composite restorations [<xref rid="B3-rde-45-e13" ref-type="bibr">3</xref>]. Despite the broad range of favorable properties that have been anticipated for composites, viscous resin monomers in composites make it difficult to sculpt them to fit the natural anatomical shapes of teeth. Therefore, various modeling agents and equipment have been proposed to improve the adaptation and configuration of composites [<xref rid="B4-rde-45-e13" ref-type="bibr">4</xref><xref rid="B5-rde-45-e13" ref-type="bibr">5</xref>]. Although this usage is not included in manufacturers' specifications, adhesives have been used as modeling agents for composites.</p><p>During incremental layering, adhesion of the composite to the application instrument is a frequently encountered problem [<xref rid="B6-rde-45-e13" ref-type="bibr">6</xref>]. To solve this problem, studies have shown that resinous monomers used for lubricating instruments or brushes simplify the process of sculpting composites [<xref rid="B6-rde-45-e13" ref-type="bibr">6</xref><xref rid="B7-rde-45-e13" ref-type="bibr">7</xref>]. For this reason, clinicians have used several lubricants in the incremental layering process to minimize stickiness by wiping the composite instrument with modeling agents, in order to facilitate manipulation and insertion of the composite [<xref rid="B8-rde-45-e13" ref-type="bibr">8</xref>]. Although these methods are widely used, a potential shortcoming is that these techniques may adversely affect the physical and surface properties of the composite [<xref rid="B2-rde-45-e13" ref-type="bibr">2</xref><xref rid="B5-rde-45-e13" ref-type="bibr">5</xref><xref rid="B7-rde-45-e13" ref-type="bibr">7</xref>]. However, to the best of our knowledge, no reports in the literature have investigated whether the presence of modeling agents in the composite structure affects the final surface properties of restorations. Moreover, it is unknown whether different compositions of adhesives or modeling agents may affect the surface microhardness, surface roughness, and color stability of composites over time.</p><p>The aim of this <italic>in vitro</italic> study was to investigate the effects of using various modeling agents with composite application instruments on the surface microhardness, surface roughness, and color change of a nano-hybrid composite applied using the layering technique. The null hypotheses tested were that: 1) the use of different modeling agents would not influence the surface microhardness, surface roughness, or color change of a nano-hybrid composite after storage in distilled water or coffee for 1 or 6 weeks, and 2) there would be no difference in any such effects among the modeling agents.</p></sec><sec sec-type="materials|methods"><title>MATERIALS AND METHODS</title><sec><title>Experimental design and specimen preparation</title><p>The surface microhardness, surface roughness, and color change of a nano-hybrid composite were evaluated. Essentia (GC Corp., Tokyo, Japan) nano-hybrid composite (with dark enamel shade) was used to fabricate 64 specimens. The composite was placed using a composite filling spatula in a Teflon mold with dimensions of 12 mm in diameter and 2 mm in thickness for each increment. Subsequently, the top surface of the specimens was treated according to the following application procedures.</p><list list-type="simple" id="L1-rde-45-e13"><list-item><p>&#x2022; In group 1 (the control group), no modeling agent was applied.</p></list-item><list-item><p>&#x2022; In group 2, the top surface of the composite specimens was regularized using a humidified sable brush with Modeling Liquid (GC Corp.).</p></list-item><list-item><p>&#x2022; In Group 3, the top surface of the composite specimens was regularized using a humidified micro-brush applicator with a universal adhesive (G-Premio Bond; GC Corp.).</p></list-item><list-item><p>&#x2022; In Group 4, the top surface of the composite specimens was regularized using a humidified micro-brush applicator with the primer of a 2-step self-adhesive system/OptiBond XTR (Kerr Corp., Orange, CA, USA).</p></list-item></list><p><xref rid="T1-rde-45-e13" ref-type="table">Table 1</xref> lists the materials, compositions, batch numbers, and their respective manufacturers.</p><table-wrap id="T1-rde-45-e13" orientation="portrait" position="float"><label>Table 1</label><caption><title>Materials used in the study</title></caption><alternatives><graphic xlink:href="rde-45-e13-i001"/><table frame="hsides" rules="rows"><col width="28.8%" span="1"/><col width="47.47%" span="1"/><col width="12.9%" span="1"/><col width="10.83%" span="1"/><thead><tr><th valign="top" align="left" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Materials</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Compositions</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Manufacturer</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Lot No.</th></tr></thead><tbody><tr><td valign="top" align="left" rowspan="2" colspan="1">Essentia (Dark Enamel) (nano-hybrid composite)</td><td valign="top" align="left" rowspan="1" colspan="1">Matrix: UDMA, Bis-EMA, Bis-GMA, TEGDMA</td><td valign="top" align="center" rowspan="2" colspan="1">GC Corp.</td><td valign="top" align="center" rowspan="2" colspan="1">1708182</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1">Filler: prepolymerized fillers, barium glass, fumed silica (filler content by volume: 65%)</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Modeling Liquid (liquid used to model composite materials for direct restorations)</td><td valign="top" align="left" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">UDMA, 2-hydroxy-1,3 dimethacryloxy propane, 2-hydroxyethyl methacrylate</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">GC Corp.</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">1805171</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1">G-Premio Bond (universal adhesive)</td><td valign="top" align="left" rowspan="1" colspan="1">10-methacryloyloxydecyl dihydrogen phosphate, 4-methacryloxyethyl trimellitate, methacryloyloxyalkyl thiophosphate methylmethacrylate, methacrylate monomer, acetone, water, silica, initiator</td><td valign="top" align="center" rowspan="1" colspan="1">GC Corp.</td><td valign="top" align="center" rowspan="1" colspan="1">1901092</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">OptiBond XTR Primer (first step of a 2-step self-adhesive system)</td><td valign="top" align="left" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Glycerol phosphate dimethacrylate, hydrophilic co-monomers, water, ethanol, acetone</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Kerr Corp.</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">6350939</td></tr></tbody></table></alternatives><table-wrap-foot><p>UDMA, urethane dimethacrylate; Bis-EMA, ethoxylated bisphenol-A dimethacrylate; Bis-GMA, bisphenol-A dimethacrylate; TEGDMA, triethylene glycol dimethacrylate.</p></table-wrap-foot></table-wrap><p>All specimens were placed between 2 glass slabs and pressed down by the weight of the top slab, with a transparent matrix in between to ensure a smooth surface, and then polymerized for 20 seconds using an LED light-curing unit (Woodpecker Med. Instrument, Guilin, China) with 1,200 mW/cm<sup>2</sup> irradiance on the top surface. Then, the specimens were taken out of the Teflon mold, the base of each specimen was numbered with a drill, and the specimens were stored at 37&#xB0;C in 100% humidity for 24 hours in an incubator. The top surfaces of the specimens were ground with 2,500- and 3,000-grit silicon carbide papers for 20 seconds under tap water. The final thickness of every test specimen was measured with a digital caliper (Digimatic Solar Calipar; Mitutoyo, Takatsu, Japan), and specimens thinner than 1.95 mm or thicker than 2.05 mm were replaced.</p><p>Surface microhardness, surface roughness, and color measurements of the specimens were made (baseline). Then, the specimens were transferred into polyethylene containers containing distilled water or coffee, and the measurements were repeated after 1 and 6 weeks of storage (<italic>n</italic> = 8).</p><p>The staining solution was prepared by adding 7.5 g of coffee (Nescaf&#xE9; Classic; Nestl&#xE9;, Vevey, Switzerland) to 500 mL of boiling distilled water. All specimens were immersed in a stainless-steel container with coffee solution and stored at 37&#xB0;C in a dark environment to simulate intraoral conditions [<xref rid="B9-rde-45-e13" ref-type="bibr">9</xref>]. The staining solution was changed every 2 days throughout the test. After the staining procedure was finished, each specimen was washed under water and dried with an air spray.</p></sec><sec><title>Surface microhardness measurements</title><p>The microhardness values of the composite surfaces were obtained with a microhardness tester (Shimadzu HMV/2000, Shimadzu Corporation, Kyoto, Japan). The Vickers hardness number (VHN) (kg/mm<sup>2</sup>) was determined after 24 hours of storage in distilled water and 1 and 6 weeks of storage in distilled water or coffee. Five indentations were made on the top surface under a 200 g load with a 10-second dwell time. The average hardness value for each specimen was then calculated.</p></sec><sec><title>Surface roughness measurements</title><p>A profilometer (Perthometer M2, Mahr, G&#xF6;ttingen, Germany) was used to determine the surface roughness of the specimens at baseline and after 1 and 6 weeks of storage in distilled water or coffee. The measurement rate was designated as 5.6 mm and the cut-off value as 0.25 mm; then, the measurement needle (10 &#x3BC;m in diameter) was positioned over each test specimen to obtain five readings at different locations of the specimens' surfaces. The mean surface roughness (Ra) value of every specimen was recorded.</p></sec><sec><title>Color measurements</title><p>The color distribution (CIE L*, a*, b*, and &#x394;E*) of each specimen was measured with a spectrophotometer (VITA Easy Shade; Vident, Brea, CA, USA). Measurements were taken at the middle third region of the specimens, and were repeated 3 times at each evaluation. The average value was then calculated. The spectrophotometer was calibrated with a white reflectance standard according to the manufacturer&#x2019;s protocol before each measurement. The overall color change (&#x394;E) of the specimens in each group was calculated using the following formula:</p><disp-formula>&#x394;E = [(&#x394;L)<sup>2</sup> + (&#x394;a)<sup>2</sup> + (&#x394;b)<sup>2</sup>]<sup>1/2</sup></disp-formula></sec><sec><title>Scanning electron microscopy evaluation</title><p>Representative specimens were selected from each group and coated with gold (5 &#xB5;m) using a sputter coating machine (Quorum Q15OT ES; Quorum Technologies Ltd., East Sussex, UK) for examination with a scanning electron microscope (SEM; Nova NanoSEM 430; FEI Company, Hillsboro, OR, USA) to analyze surface morphology before storage and after 1 and 6 weeks of storage at &#xD7;2,000 magnification.</p></sec><sec><title>Statistical analysis</title><p>Data were analyzed using SPSS version 16 (SPSS Inc., Chicago, IL, USA). The effects of the presence of a modeling agent and storage medium and time on the VHN, Ra, and &#x394;E of the groups were analyzed using the Kruskal-Wallis non-parametric test, followed by the Bonferroni corrected pairwise comparison test (&#x3B1; = 5%).</p></sec></sec><sec sec-type="results"><title>RESULTS</title><sec><title>Surface microhardness</title><p>The results for surface microhardness are shown in <xref rid="T2-rde-45-e13" ref-type="table">Table 2</xref>. Storage time did not influence the VHN of the nano-hybrid composite in any group, and no significant difference was observed at any measurement time point (<italic>p</italic> &gt; 0.05). The group in which OptiBond XTR Primer was applied exhibited lower surface microhardness values than the other groups for all investigated storage media and time intervals (<italic>p</italic> &lt; 0.05). However, the surface microhardness of the tested groups was not affected by the storage medium (distilled water or coffee) (<italic>p</italic> &gt; 0.05).</p><table-wrap id="T2-rde-45-e13" orientation="portrait" position="float"><label>Table 2</label><caption><title>Surface microhardness values (VHN) (median and 25%&#x2013;75% values) of the tested groups</title></caption><alternatives><graphic xlink:href="rde-45-e13-i002"/><table frame="hsides" rules="rows"><col width="11.22%" span="1"/><col width="12.71%" span="1"/><col width="12.71%" span="1"/><col width="12.71%" span="1"/><col width="6.27%" span="1"/><col width="12.71%" span="1"/><col width="12.71%" span="1"/><col width="12.71%" span="1"/><col width="6.27%" span="1"/><thead><tr><th valign="top" align="left" rowspan="2" colspan="1" style="background-color:rgb(254,226,201)">Groups</th><th valign="top" align="center" rowspan="1" colspan="4" style="background-color:rgb(254,226,201)">Distilled water</th><th valign="top" align="center" rowspan="1" colspan="4" style="background-color:rgb(254,226,201)">Coffee</th></tr><tr><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Baseline</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">1 week</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">6 weeks</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)"><italic>p</italic></th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Baseline</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">1 week</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">6 weeks</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)"><italic>p</italic></th></tr></thead><tbody><tr><td valign="top" align="left" rowspan="1" colspan="1">Control</td><td valign="top" align="center" rowspan="1" colspan="1">53.40 (51.56&#x2013;58.78)</td><td valign="top" align="center" rowspan="1" colspan="1">55.03 (40.01&#x2013;57.29)</td><td valign="top" align="center" rowspan="1" colspan="1">52.86 (46.44&#x2013;56.50)</td><td valign="top" align="center" rowspan="1" colspan="1">0.185</td><td valign="top" align="center" rowspan="1" colspan="1">53.37 (51.97&#x2013;55.13)</td><td valign="top" align="center" rowspan="1" colspan="1">53.68 (48.62&#x2013;58.88)</td><td valign="top" align="center" rowspan="1" colspan="1">53.53 (46.11&#x2013;54.66)</td><td valign="top" align="center" rowspan="1" colspan="1">0.335</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Modeling Liquid</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">55.19 (52.81&#x2013;57.85)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">58.86 (56.52&#x2013;62.33)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">55.28 (51.87&#x2013;57.85)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.250</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">53.58 (52.77&#x2013;55.60)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">53.33 (50.45&#x2013;56.34)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">52.53 (50.19&#x2013;54.05)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.859</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1">Universal adhesive</td><td valign="top" align="center" rowspan="1" colspan="1">52.15 (43.68&#x2013;53.08)</td><td valign="top" align="center" rowspan="1" colspan="1">51.02 (48.48&#x2013;53.88)</td><td valign="top" align="center" rowspan="1" colspan="1">49.27 (40.56&#x2013;51.15)</td><td valign="top" align="center" rowspan="1" colspan="1">0.546</td><td valign="top" align="center" rowspan="1" colspan="1">48.89 (40.25&#x2013;49.54)</td><td valign="top" align="center" rowspan="1" colspan="1">47.82 (45.24&#x2013;57.50)</td><td valign="top" align="center" rowspan="1" colspan="1">46.05 (45.37&#x2013;49.99)</td><td valign="top" align="center" rowspan="1" colspan="1">0.670</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Primer</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">49.36 (45.81&#x2013;53.26)<sup>*</sup></td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">50.76 (47.89&#x2013;51.98)<sup>*</sup></td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">45.73 (42.80&#x2013;49.33)<sup>*</sup></td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.496</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">45.27 (45.27&#x2013;47.83)<sup>*</sup></td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">45.68 (45.28&#x2013;46.01)<sup>*</sup></td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">43.84 (45.40&#x2013;48.76)<sup>*</sup></td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.129</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1"><italic>p</italic></td><td valign="top" align="center" rowspan="1" colspan="1">0.023</td><td valign="top" align="center" rowspan="1" colspan="1">0.003</td><td valign="top" align="center" rowspan="1" colspan="1">0.003</td><td valign="top" align="center" rowspan="1" colspan="1"/><td valign="top" align="center" rowspan="1" colspan="1">0.007</td><td valign="top" align="center" rowspan="1" colspan="1">0.025</td><td valign="top" align="center" rowspan="1" colspan="1">0.045</td><td valign="top" align="center" rowspan="1" colspan="1"/></tr></tbody></table></alternatives><table-wrap-foot><p><sup>*</sup>Represents a significant difference among the groups in a column (<italic>p</italic> &lt; 0.05).</p></table-wrap-foot></table-wrap></sec><sec><title>Surface roughness</title><p>The results for surface roughness are presented in <xref rid="T3-rde-45-e13" ref-type="table">Table 3</xref>. No statistically significant differences in any group for storage in distilled water were found (<italic>p</italic> &gt; 0.05). The only significant difference was observed in the group in which Modeling Liquid was applied in the coffee storage medium; it was found that Modeling Liquid application preserved the surface roughness of the nano-hybrid composite better than the other groups (<italic>p</italic> &lt; 0.05).</p><table-wrap id="T3-rde-45-e13" orientation="portrait" position="float"><label>Table 3</label><caption><title>Surface roughness values (Ra) (median and 25%&#x2013;75% values) of the tested groups</title></caption><alternatives><graphic xlink:href="rde-45-e13-i003"/><table frame="hsides" rules="rows"><col width="12.32%" span="1"/><col width="12.32%" span="1"/><col width="12.32%" span="1"/><col width="12.32%" span="1"/><col width="6.88%" span="1"/><col width="12.32%" span="1"/><col width="12.32%" span="1"/><col width="12.32%" span="1"/><col width="6.88%" span="1"/><thead><tr><th valign="top" align="left" rowspan="2" colspan="1" style="background-color:rgb(254,226,201)">Groups</th><th valign="top" align="center" rowspan="1" colspan="4" style="background-color:rgb(254,226,201)">Water</th><th valign="top" align="center" rowspan="1" colspan="4" style="background-color:rgb(254,226,201)">Coffee</th></tr><tr><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Baseline</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">1 week</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">6 weeks</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)"><italic>p</italic></th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Baseline</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">1 week</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">6 weeks</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)"><italic>p</italic></th></tr></thead><tbody><tr><td valign="top" align="left" rowspan="1" colspan="1">Control</td><td valign="top" align="center" rowspan="1" colspan="1">0.15 (0.16&#x2013;0.35)</td><td valign="top" align="center" rowspan="1" colspan="1">0.17 (0.13&#x2013;0.25)</td><td valign="top" align="center" rowspan="1" colspan="1">0.18 (0.12&#x2013;0.23)</td><td valign="top" align="center" rowspan="1" colspan="1">0.476</td><td valign="top" align="center" rowspan="1" colspan="1">0.17 (0.09&#x2013;0.19)</td><td valign="top" align="center" rowspan="1" colspan="1">0.18 (0.16&#x2013;0.20)</td><td valign="top" align="center" rowspan="1" colspan="1">0.19 (0.12&#x2013;0.30)</td><td valign="top" align="center" rowspan="1" colspan="1">0.586</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Modeling Liquid</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.12 (0.08&#x2013;0.19)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.13 (0.08&#x2013;0.16)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.15 (0.12&#x2013;0.27)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.417</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.09 (0.07&#x2013;0.12)<sup>*</sup></td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.10 (0.09&#x2013;0.18)<sup>*</sup></td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.11 (0.08&#x2013;0.14)<sup>*</sup></td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.528</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1">Universal adhesive</td><td valign="top" align="center" rowspan="1" colspan="1">0.13 (0.11&#x2013;0.24)</td><td valign="top" align="center" rowspan="1" colspan="1">0.15 (0.11&#x2013;0.28)</td><td valign="top" align="center" rowspan="1" colspan="1">0.18 (0.09&#x2013;0.19)</td><td valign="top" align="center" rowspan="1" colspan="1">0.607</td><td valign="top" align="center" rowspan="1" colspan="1">0.14 (0.11&#x2013;0.20)</td><td valign="top" align="center" rowspan="1" colspan="1">0.15 (0.12&#x2013;0.21)</td><td valign="top" align="center" rowspan="1" colspan="1">0.15 (0.14&#x2013;0.16)</td><td valign="top" align="center" rowspan="1" colspan="1">0.788</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Primer</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.20 (0.11&#x2013;0.43)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.27 (0.14&#x2013;0.39)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.28 (0.13&#x2013;0.34)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.939</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.18 (0.17&#x2013;0.27)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.18 (0.12&#x2013;0.25)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.21 (0.13&#x2013;0.26)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.649</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1"><italic>p</italic></td><td valign="top" align="center" rowspan="1" colspan="1">0.086</td><td valign="top" align="center" rowspan="1" colspan="1">0.131</td><td valign="top" align="center" rowspan="1" colspan="1">0.223</td><td valign="top" align="center" rowspan="1" colspan="1"/><td valign="top" align="center" rowspan="1" colspan="1">0.027</td><td valign="top" align="center" rowspan="1" colspan="1">0.024</td><td valign="top" align="center" rowspan="1" colspan="1">0.029</td><td valign="top" align="center" rowspan="1" colspan="1"/></tr></tbody></table></alternatives><table-wrap-foot><p><sup>*</sup>Represents a significant difference among the groups in a column (<italic>p</italic> &lt; 0.05).</p></table-wrap-foot></table-wrap></sec><sec><title>Color changes</title><p>The results for color changes are summarized in <xref rid="T4-rde-45-e13" ref-type="table">Table 4</xref>. The color changes for the groups ranged from 0.82 to 6.01 &#x394;E* units. Color changes were significantly influenced by the storage medium and the application method (<italic>p</italic> &lt; 0.05). Modeling Liquid application was associated with the lowest &#x394;E values in all investigated storage media and at all time intervals, and it protected the nano-hybrid composite specimens from discoloration induced by storage in coffee significantly better than the other application procedures (<italic>p</italic> &lt; 0.05).</p><table-wrap id="T4-rde-45-e13" orientation="portrait" position="float"><label>Table 4</label><caption><title>Color change values (&#x394;E) (Median and 25%&#x2013;75% values) of the tested groups between the measurement periods</title></caption><alternatives><graphic xlink:href="rde-45-e13-i004"/><table frame="hsides" rules="rows"><col width="12.32%" span="1"/><col width="12.32%" span="1"/><col width="12.32%" span="1"/><col width="12.32%" span="1"/><col width="6.88%" span="1"/><col width="12.32%" span="1"/><col width="12.32%" span="1"/><col width="12.32%" span="1"/><col width="6.88%" span="1"/><thead><tr><th valign="top" align="left" rowspan="2" colspan="1" style="background-color:rgb(254,226,201)">Groups</th><th valign="top" align="center" rowspan="1" colspan="4" style="background-color:rgb(254,226,201)">Water</th><th valign="top" align="center" rowspan="1" colspan="4" style="background-color:rgb(254,226,201)">Coffee</th></tr><tr><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Baseline to 1W</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Baseline to 6W</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">1W to 6W</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)"><italic>p</italic></th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Baseline to 1W</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Baseline to 6W</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">1W to 6W</th><th valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)"><italic>p</italic></th></tr></thead><tbody><tr><td valign="top" align="left" rowspan="1" colspan="1">Control</td><td valign="top" align="center" rowspan="1" colspan="1">1.66 (1.02&#x2013;2.56)</td><td valign="top" align="center" rowspan="1" colspan="1">1.83 (1.07&#x2013;2.98)</td><td valign="top" align="center" rowspan="1" colspan="1">1.94 (1.12&#x2013;2.36)</td><td valign="top" align="center" rowspan="1" colspan="1">0.417</td><td valign="top" align="center" rowspan="1" colspan="1">4.46 (2.03&#x2013;5.35)</td><td valign="top" align="center" rowspan="1" colspan="1">6.01 (6.60&#x2013;7.45)</td><td valign="top" align="center" rowspan="1" colspan="1">3.40 (2.71&#x2013;5.74)</td><td valign="top" align="center" rowspan="1" colspan="1">0.223</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Modeling liquid</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.84 (0.41&#x2013;1.89)<sup>*</sup></td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">1.42 (0.67&#x2013;2.89)<sup>*</sup></td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">1.64 (0.89&#x2013;3.29)<sup>*</sup></td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.607</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">3.03 (3.02&#x2013;3.74)<sup>*</sup></td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">3.11 (3.43&#x2013;4.10)<sup>*</sup></td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">1.74 (1.41&#x2013;2.58)<sup>*</sup></td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.021<sup>*</sup></td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1">Universal adhesive</td><td valign="top" align="center" rowspan="1" colspan="1">2.95 (0.38&#x2013;4.42)</td><td valign="top" align="center" rowspan="1" colspan="1">3.50 (3.67&#x2013;6.48)</td><td valign="top" align="center" rowspan="1" colspan="1">3.22 (2.55&#x2013;6.64)</td><td valign="top" align="center" rowspan="1" colspan="1">0.390</td><td valign="top" align="center" rowspan="1" colspan="1">5.53 (4.60&#x2013;6.34)</td><td valign="top" align="center" rowspan="1" colspan="1">5.95 (3.18&#x2013;6.43)</td><td valign="top" align="center" rowspan="1" colspan="1">5.80 (4.80&#x2013;6.55)</td><td valign="top" align="center" rowspan="1" colspan="1">0.882</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">Primer</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">2.98 (2.37&#x2013;4.19)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">3.02 (1.33&#x2013;4.93)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">3.03 (1.56&#x2013;3.57)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.687</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">4.90 (2.65&#x2013;5.50)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">4.78 (2.88&#x2013;5.21)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">4.68 (2.56&#x2013;4.60)</td><td valign="top" align="center" rowspan="1" colspan="1" style="background-color:rgb(254,226,201)">0.607</td></tr><tr><td valign="top" align="left" rowspan="1" colspan="1"><italic>p</italic></td><td valign="top" align="center" rowspan="1" colspan="1">0.021</td><td valign="top" align="center" rowspan="1" colspan="1">0.045</td><td valign="top" align="center" rowspan="1" colspan="1">0.014</td><td valign="top" align="center" rowspan="1" colspan="1"/><td valign="top" align="center" rowspan="1" colspan="1">0.019</td><td valign="top" align="center" rowspan="1" colspan="1">0.015</td><td valign="top" align="center" rowspan="1" colspan="1">0.017</td><td valign="top" align="center" rowspan="1" colspan="1"/></tr></tbody></table></alternatives><table-wrap-foot><p>1W, 1 week; 6W, 6 weeks,</p><p><sup>*</sup>Represents the significant difference among the groups in each column (<italic>p</italic> &lt; 0.05).</p></table-wrap-foot></table-wrap></sec><sec><title>SEM</title><p><xref ref-type="fig" rid="F1-rde-45-e13">Figure 1</xref> shows SEM images of specimens from each group that were stored in distilled water or coffee for 6 weeks. The specimens stored in different storage media did not present a clear pattern of degradation, especially in the control group (<xref ref-type="fig" rid="F1-rde-45-e13">Figure 1</xref>).</p><fig id="F1-rde-45-e13" fig-type="figure" orientation="portrait" position="float"><label>Figure 1</label><caption><title>Scanning electron microscopy images showing the surface topography of nano-hybrid composite specimens at &#xD7;2,000 magnification. (A-C) show control group specimens stored in distilled water for 24 hours, stored in distilled water for 6 weeks, and stored in coffee for 6 weeks, respectively. (D-F) show Modeling Liquid group specimens stored in distilled water for 24 hours, stored in distilled water for 6 weeks, and stored in coffee for 6 weeks. (G-I) show universal adhesive group specimens stored in distilled water for 24 hours, stored in distilled water for 6 weeks, and stored in coffee for 6 weeks. (J-L) show specimens from the primer of the 2-step self-etch adhesive group stored in distilled water for 24 hours, stored in distilled water for 6 weeks, and stored in coffee for 6 weeks, respectively.</title><p>WD, working distance; HV, high voltage; HFW, horizontal frame width.</p></caption><graphic xlink:href="rde-45-e13-g001"/></fig></sec></sec><sec sec-type="discussion"><title>DISCUSSION</title><p>The degree to which modeling agents make it easier to handle composite restorations has led numerous dental professionals to use this technique. Using a brush wetted with a modeling agent makes composites less sticky, resulting in easier and faster application and shaping. Applying the final layer of composites using a wetted brush also enables the clinician to smoothen it efficiently and to achieve a very satisfactory surface. This simplifies the finishing procedure and saves valuable time. However, doubts have arisen regarding possible changes in the characteristics and properties of composites caused by the application of these agents, particularly changes related to the surface microhardness, roughness, and color stability of restorations over time [<xref rid="B4-rde-45-e13" ref-type="bibr">4</xref><xref rid="B10-rde-45-e13" ref-type="bibr">10</xref>]. Thus, the present study evaluated the effects of different kinds of modeling agents on the surface microhardness, surface roughness, and color change of a nano-hybrid composite exposed to coffee staining over time. Favorable results were found in comparison to the conventional technique (without the use of modeling), with similar or superior surface physical properties and color variations.</p><p>In the analysis according to the presence of a modeling agent, the use of various modeling agents to prepare specimens influenced the surface microhardness, surface roughness and overall color change of the tested nano-hybrid composite, in comparison with the specimens prepared without a modeling agent; therefore, the first null hypothesis of the study was rejected.</p><p>The use of low-viscosity materials (<italic>e.g.,</italic> resin adhesives) as modeling agents for resin composites has been reported to provide a way of achieving good clinical results with adequate insertion, and these materials have been reported to be especially useful for modeling of composite increments, but scientific evidence supporting their use for this purpose is lacking. Considering that adhesives have been mainly used as modeling agents for composites during the build-up process of anterior esthetic restorations, it would be interesting to determine whether this technique may negatively affect the surface and color stability properties of esthetic nano-hybrid composites. The present research is a pioneer study showing the positive effects of using the tested Modeling Liquid to sculpt and to model the nano-hybrid composite [<xref rid="B11-rde-45-e13" ref-type="bibr">11</xref>].</p><p>In the present study, the surface microhardness of the nano-hybrid composite was similar, regardless of whether the universal adhesive, Modeling Liquid, or no modeling agent was used. In contrast, using the primer of the self-adhesive system influenced the surface microhardness negatively (<xref rid="T2-rde-45-e13" ref-type="table">Table 2</xref>). One explanation for this difference in surface microhardness of the nano-hybrid composite is related to the pH value (1.6) of this alternative modeling agent. Although the finishing and polishing processes remove the resin-rich layer of a composite specimen cured under a polyester matrix strip and might remove the top surface of the composite, which was affected by the modeling agent, a softening effect of the primer due to its low pH was seen. It is suggested that the application of universal adhesive or Modeling Liquid within the composite surface avoided the occurrence of defects or voids during the modeling of the material, making the composite more resistant to degradation [<xref rid="B12-rde-45-e13" ref-type="bibr">12</xref>]. Although no clear structural and morphological differences could be detected among specimens prepared with or without a modeling agent, specimens prepared with an adhesive primer exhibited considerably lower mechanical stability than the other groups. However, the findings of this study regarding surface microhardness are in disagreement with those of the study performed by Tuncer <italic>et al</italic>. [<xref rid="B10-rde-45-e13" ref-type="bibr">10</xref>], who reported that significantly lower microhardness values were achieved in composite specimens that were prepared with modeling resin under a polyester matrix strip. They explained their findings on the basis of a resin-rich layer on the surfaces of the tested composites caused by the modeling resin.</p><p>Some liquid resins have been suggested as a way to achieve smoother surfaces in composites [<xref rid="B13-rde-45-e13" ref-type="bibr">13</xref><xref rid="B14-rde-45-e13" ref-type="bibr">14</xref>]. However, it has proven difficult to obtain a regular surface with liquid resins [<xref rid="B9-rde-45-e13" ref-type="bibr">9</xref>]. In the present study, while the Ra values of the control, Modeling Liquid, and universal adhesive test groups were below the plaque accumulation threshold level of 0.20 mm [<xref rid="B15-rde-45-e13" ref-type="bibr">15</xref>], the groups where Modeling Liquid and universal adhesive were used exhibited similar Ra values to those of the control group. The present study also showed statistically significantly higher Ra values for the self-adhesive system group than for the other groups. The variations in the Ra values of the tested modeling agents in the present study may also be attributed to the effects of their low pH. The low pH value of modeling agents can cause deterioration of the top surface of the composite, potentially leading to the formation of microcracks and removal of the resin matrix.</p><p>These findings confirm the superiority of the tested universal adhesive or Modeling Liquid as a modeling agent for improving the surface texture of nano-hybrid composites and avoiding irregularities and defects on the top surface of composite restorations. This can be attributed to enhanced adaptation of the composite layers, which hinders the composite from sticking to the hand tools.</p><p>The results of this study also showed that the storage medium (coffee) did not affect the surface roughness of the nano-hybrid composite at the investigated storage times. One limitation of this study is that the maximum storage time was 6 weeks, as long-term aging studies have shown that deterioration of nano-hybrid composite surfaces may occur after long periods of storage [<xref rid="B16-rde-45-e13" ref-type="bibr">16</xref><xref rid="B17-rde-45-e13" ref-type="bibr">17</xref>]. However, the Ra values in the Modeling Liquid group were influenced less than those in the other groups by storage in coffee. This finding could be explained by the similar composition of Modeling Liquid and the nano-hybrid composite resin matrix.</p><p>A minimum &#x394;E* is one of the most important characteristics desired for composite restorations, especially those involving the anterior teeth. However, composites commonly suffer from degradation because of their polymeric structure, which results in a compromised color appearance over time. According to recent studies, the use of modeling agents (<italic>e.g.,</italic> adhesive resins) between composite layers may be a useful strategy to reduce or delay composite staining [<xref rid="B5-rde-45-e13" ref-type="bibr">5</xref><xref rid="B11-rde-45-e13" ref-type="bibr">11</xref>]. Thus, one of the purposes of the present study was to investigate whether the color shade of a nano-hybrid composite prepared with a modeling agent would change after 6 weeks of storage in distilled water or coffee. In the overall analysis, the &#x394;E* of the nano-hybrid composite depended on the type of modeling agent used. Only &#x394;E* values in the Modeling Liquid group remained stable over time regardless of storage medium; by contrast, the control, universal adhesive and primer of the self-adhesive system groups showed increased &#x394;E* values after 6 weeks of storage in water and coffee compared with the baseline values. These findings demonstrate that the type of modeling agent used for layering plays an important role in the color stability of the composite.</p><p>Similarly to specimens prepared with a universal adhesive, the specimens from the primer of the self-adhesive group and the control specimens demonstrated increased &#x394;E* values after 6 weeks of water storage, which may be explained by the strong tendency of polymer-based materials to undergo hydrolysis [<xref rid="B18-rde-45-e13" ref-type="bibr">18</xref>]. Water is a potent solvent capable of degrading the intermolecular bonds of composites [<xref rid="B19-rde-45-e13" ref-type="bibr">19</xref>]. The use of a hydrophobic unfilled resin (Modeling Liquid) as a modeling agent also helped keep the color of the composite stable over time, even after 6 weeks of water or coffee storage, likely because the modeling liquid exerted a protective effect against hydrolysis. This finding is corroborated by recent studies [<xref rid="B4-rde-45-e13" ref-type="bibr">4</xref><xref rid="B11-rde-45-e13" ref-type="bibr">11</xref>].</p><p>In the present study, the primer of a 2-step self-adhesive system that was tested as a modeling agent for sculpting composite specimens contained a hydrophilic co-monomer, water, and ethanol. The presence of water in this material possibly contributed to its attraction of additional water into the resin matrix, which softened the top surface of the specimens where the material was applied with a micro-brush. For this reason, the microhardness of this group was significantly lower than that of the other groups. Previous studies have demonstrated that as the volume of unfilled resin increases, a greater amount of water is absorbed into the matrix [<xref rid="B20-rde-45-e13" ref-type="bibr">20</xref><xref rid="B21-rde-45-e13" ref-type="bibr">21</xref>]. Thus, it is possible that the increased hydrophilic co-monomer content of the modeling agent was the mechanism responsible for the decreased microhardness and increased color change. Additionally, similar to our study, previous studies have mentioned that the hydrophilic characteristics of these monomers and solvents made restorations more prone to absorbing staining pigments and to changing color over time [<xref rid="B7-rde-45-e13" ref-type="bibr">7</xref><xref rid="B10-rde-45-e13" ref-type="bibr">10</xref><xref rid="B11-rde-45-e13" ref-type="bibr">11</xref><xref rid="B22-rde-45-e13" ref-type="bibr">22</xref>].</p><p>The pH values of the universal adhesive and the primer of the 2-step self-adhesive system tested in this study were 2.1 and 1.6, respectively. However, the pH value of the universal adhesive did not affect the tested parameters to the same extent as the primer of the 2-step self-adhesive system. This could be explained by the nano-filler content of the universal adhesive.</p><p>The optical appearance of composite restorations should ideally not change over time. In a study by Tuncer <italic>et al.</italic> [<xref rid="B10-rde-45-e13" ref-type="bibr">10</xref>], the color stability of composites was negatively affected by covering them with a superficial layer of a modeling agent. The optical properties of composites are not expected to remain stable over time, especially considering the degradation that composites may undergo after placement in the oral environment [<xref rid="B23-rde-45-e13" ref-type="bibr">23</xref>]. Color shade is the main property susceptible to modification, and special attention must be given to restorations prepared using modeling agents because these agents may influence the color of composites after aging [<xref rid="B4-rde-45-e13" ref-type="bibr">4</xref>].</p><p>Although the specimens prepared using Modeling Liquid showed better surface and color stability properties than the other groups, an analysis of SEM images (<xref ref-type="fig" rid="F1-rde-45-e13">Figure 1</xref>) demonstrated that, after storage in distilled water or coffee, the specimens prepared with Modeling Liquid did not exhibit visibly smoother surfaces than the other groups.</p><p>Important limitations of this study include the fact that only 1 type of composite was tested, the use of only a 6-week storage time, and not applying thermocycling for aging.</p><p>Taking the findings together, the first null hypothesis tested here was rejected. Although the composites prepared with the primer of the self-adhesive system showed reduced surface microhardness after aging in both storage media and at both storage times, those prepared with Modeling Liquid exhibited a more planar surface in coffee and greater color stability in both storage media and at both storage times. The second null hypothesis tested here was accepted, because storage in distilled water or coffee for 1 and 6 weeks did not affect the surface microhardness, surface roughness, or color change of a nano-hybrid composite.</p></sec><sec sec-type="conclusions"><title>CONCLUSIONS</title><p>According to our findings, it can be concluded that Modeling Liquid and a universal adhesive can be applied to a nano-hybrid composite to sculpt the outer layer without jeopardizing important properties of the material. Furthermore, Modeling Liquid was the only substance capable of truly enhancing the mechanical properties of the composite and the stability of the material over time.</p></sec></body><back><fn-group><fn fn-type="COI-statement"><p><bold>Conflict of Interest:</bold> No potential conflict of interest relevant to this article was reported.</p></fn><fn fn-type="con"><p><bold>Author Contributions:</bold>
<list list-type="simple"><list-item><p><bold>Conceptualization:</bold> Kutuk ZB, Erden E, Aksahin DL, Durak ZE, Dulda AC.</p></list-item><list-item><p><bold>Data curation:</bold> Kutuk ZB, Erden E, Aksahin DL, Durak ZE, Dulda AC.</p></list-item><list-item><p><bold>Formal analysis:</bold> Kutuk ZB, Erden E, Aksahin DL, Durak ZE, Dulda AC.</p></list-item><list-item><p><bold>Funding acquisition:</bold> Kutuk ZB, Erden E, Aksahin DL, Durak ZE, Dulda AC.</p></list-item><list-item><p><bold>Investigation:</bold> Kutuk ZB.</p></list-item><list-item><p><bold>Methodology:</bold> Kutuk ZB.</p></list-item><list-item><p><bold>Project administration:</bold> Kutuk ZB.</p></list-item><list-item><p><bold>Resources:</bold> Kutuk ZB.</p></list-item><list-item><p><bold>Software:</bold> Kutuk ZB, Erden E, Aksahin DL, Durak ZE, Dulda AC.</p></list-item><list-item><p><bold>Supervision:</bold> Kutuk ZB.</p></list-item><list-item><p><bold>Validation:</bold> Kutuk ZB.</p></list-item><list-item><p><bold>Visualization:</bold> Kutuk ZB.</p></list-item><list-item><p><bold>Writing - original draft:</bold> Kutuk ZB.</p></list-item><list-item><p><bold>Writing - review &amp; editing:</bold> Kutuk ZB, Erden E, Aksahin DL, Durak ZE, Dulda AC.</p></list-item></list>
</p></fn></fn-group><ref-list><ref id="B1-rde-45-e13"><label>1</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Rosa</surname><given-names>WL</given-names></name><name><surname>Piva</surname><given-names>E</given-names></name><name><surname>Silva</surname><given-names>AF</given-names></name></person-group><article-title>Bond strength of universal adhesives: a systematic review and meta-analysis</article-title><source>J Dent</source><year>2015</year><volume>43</volume><fpage>765</fpage><lpage>776</lpage><pub-id pub-id-type="pmid">25882585</pub-id></element-citation></ref><ref id="B2-rde-45-e13"><label>2</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Nahsan</surname><given-names>FP</given-names></name><name><surname>Mondelli</surname><given-names>RF</given-names></name><name><surname>Franco</surname><given-names>EB</given-names></name><name><surname>Naufel</surname><given-names>FS</given-names></name><name><surname>Ueda</surname><given-names>JK</given-names></name><name><surname>Schmitt</surname><given-names>VL</given-names></name><name><surname>Baseggio</surname><given-names>W</given-names></name></person-group><article-title>Clinical strategies for esthetic excellence in anterior tooth restorations: understanding color and composite resin selection</article-title><source>J Appl Oral Sci</source><year>2012</year><volume>20</volume><fpage>151</fpage><lpage>156</lpage><pub-id pub-id-type="pmid">22666829</pub-id></element-citation></ref><ref id="B3-rde-45-e13"><label>3</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Pontons-Melo</surname><given-names>JC</given-names></name><name><surname>Furuse</surname><given-names>AY</given-names></name><name><surname>Mondelli</surname><given-names>J</given-names></name></person-group><article-title>A direct composite resin stratification technique for restoration of the smile</article-title><source>Quintessence Int</source><year>2011</year><volume>42</volume><fpage>205</fpage><lpage>211</lpage><pub-id pub-id-type="pmid">21465007</pub-id></element-citation></ref><ref id="B4-rde-45-e13"><label>4</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Sedrez-Porto</surname><given-names>JA</given-names></name><name><surname>M&#xFC;nchow</surname><given-names>EA</given-names></name><name><surname>Brondani</surname><given-names>LP</given-names></name><name><surname>Cenci</surname><given-names>MS</given-names></name><name><surname>Pereira-Cenci</surname><given-names>T</given-names></name></person-group><article-title>Effects of modeling liquid/resin and polishing on the color change of resin composite</article-title><source>Braz Oral Res</source><year>2016</year><volume>30</volume><fpage>1</fpage><lpage>9</lpage></element-citation></ref><ref id="B5-rde-45-e13"><label>5</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Sedrez-Porto</surname><given-names>JA</given-names></name><name><surname>M&#xFC;nchow</surname><given-names>EA</given-names></name><name><surname>Cenci</surname><given-names>MS</given-names></name><name><surname>Pereira-Cenci</surname><given-names>T</given-names></name></person-group><article-title>Translucency and color stability of resin composite and dental adhesives as modeling liquids - A one-year evaluation</article-title><source>Braz Oral Res</source><year>2017</year><volume>31</volume><elocation-id>e54</elocation-id><pub-id pub-id-type="pmid">28678973</pub-id></element-citation></ref><ref id="B6-rde-45-e13"><label>6</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Dunn</surname><given-names>WJ</given-names></name><name><surname>Strong</surname><given-names>TC</given-names></name></person-group><article-title>Effect of alcohol and unfilled resin in the incremental buildup of resin composite</article-title><source>Quintessence Int</source><year>2007</year><volume>38</volume><fpage>e20</fpage><lpage>e26</lpage><pub-id pub-id-type="pmid">17508071</pub-id></element-citation></ref><ref id="B7-rde-45-e13"><label>7</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Barcellos</surname><given-names>DC</given-names></name><name><surname>Pucci</surname><given-names>CR</given-names></name><name><surname>Torres</surname><given-names>CR</given-names></name><name><surname>Goto</surname><given-names>EH</given-names></name><name><surname>Inocencio</surname><given-names>AC</given-names></name></person-group><article-title>Effects of resinous monomers used in restorative dental modeling on the cohesive strength of composite resin</article-title><source>J Adhes Dent</source><year>2008</year><volume>10</volume><fpage>351</fpage><lpage>354</lpage><pub-id pub-id-type="pmid">19058680</pub-id></element-citation></ref><ref id="B8-rde-45-e13"><label>8</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Perdig&#x103;o</surname><given-names>J</given-names></name><name><surname>Gomes</surname><given-names>G</given-names></name></person-group><article-title>Effect of instrument lubricant on the cohesive strength of a hybrid resin composite</article-title><source>Quintessence Int</source><year>2006</year><volume>37</volume><fpage>621</fpage><lpage>625</lpage><pub-id pub-id-type="pmid">16922021</pub-id></element-citation></ref><ref id="B9-rde-45-e13"><label>9</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Bertrand</surname><given-names>MF</given-names></name><name><surname>Leforestier</surname><given-names>E</given-names></name><name><surname>Muller</surname><given-names>M</given-names></name><name><surname>Lupi-P&#xE9;gurier</surname><given-names>L</given-names></name><name><surname>Bolla</surname><given-names>M</given-names></name></person-group><article-title>Effect of surface penetrating sealant on surface texture and microhardness of composite resins</article-title><source>J Biomed Mater Res</source><year>2000</year><volume>53</volume><fpage>658</fpage><lpage>663</lpage><pub-id pub-id-type="pmid">11074424</pub-id></element-citation></ref><ref id="B10-rde-45-e13"><label>10</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Tuncer</surname><given-names>S</given-names></name><name><surname>Demirci</surname><given-names>M</given-names></name><name><surname>Tiryaki</surname><given-names>M</given-names></name><name><surname>Unl&#xFC;</surname><given-names>N</given-names></name><name><surname>Uysal</surname><given-names>&#xD6;</given-names></name></person-group><article-title>The effect of a modeling resin and thermocycling on the surface hardness, roughness, and color of different resin composites</article-title><source>J Esthet Restor Dent</source><year>2013</year><volume>25</volume><fpage>404</fpage><lpage>419</lpage><pub-id pub-id-type="pmid">24172016</pub-id></element-citation></ref><ref id="B11-rde-45-e13"><label>11</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>M&#xFC;nchow</surname><given-names>EA</given-names></name><name><surname>Sedrez-Porto</surname><given-names>JA</given-names></name><name><surname>Piva</surname><given-names>E</given-names></name><name><surname>Pereira-Cenci</surname><given-names>T</given-names></name><name><surname>Cenci</surname><given-names>MS</given-names></name></person-group><article-title>Use of dental adhesives as modeler liquid of resin composites</article-title><source>Dent Mater</source><year>2016</year><volume>32</volume><fpage>570</fpage><lpage>577</lpage><pub-id pub-id-type="pmid">26850844</pub-id></element-citation></ref><ref id="B12-rde-45-e13"><label>12</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ye</surname><given-names>Q</given-names></name><name><surname>Spencer</surname><given-names>P</given-names></name><name><surname>Wang</surname><given-names>Y</given-names></name><name><surname>Misra</surname><given-names>A</given-names></name></person-group><article-title>Relationship of solvent to the photopolymerization process, properties, and structure in model dentin adhesives</article-title><source>J Biomed Mater Res A</source><year>2007</year><volume>80</volume><fpage>342</fpage><lpage>350</lpage><pub-id pub-id-type="pmid">17001655</pub-id></element-citation></ref><ref id="B13-rde-45-e13"><label>13</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Perez</surname><given-names>CR</given-names></name><name><surname>Hirata</surname><given-names>RJ</given-names></name><name><surname>da Silva</surname><given-names>AH</given-names></name><name><surname>Sampaio</surname><given-names>EM</given-names></name><name><surname>de Miranda</surname><given-names>MS</given-names></name></person-group><article-title>Effect of a glaze/composite sealant on the 3-D surface roughness of esthetic restorative materials</article-title><source>Oper Dent</source><year>2009</year><volume>34</volume><fpage>674</fpage><lpage>680</lpage><pub-id pub-id-type="pmid">19953776</pub-id></element-citation></ref><ref id="B14-rde-45-e13"><label>14</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Lowe</surname><given-names>RA</given-names></name></person-group><article-title>Using BisCover surface sealant/polish on direct and indirect composite and bisacrylic provisional restorations</article-title><source>Compend Contin Educ Dent</source><year>2004</year><volume>25</volume><fpage>400</fpage><lpage>401</lpage><pub-id pub-id-type="pmid">15181781</pub-id></element-citation></ref><ref id="B15-rde-45-e13"><label>15</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Bollen</surname><given-names>CM</given-names></name><name><surname>Papaioanno</surname><given-names>W</given-names></name><name><surname>Van Eldere</surname><given-names>J</given-names></name><name><surname>Schepers</surname><given-names>E</given-names></name><name><surname>Quirynen</surname><given-names>M</given-names></name><name><surname>van Steenberghe</surname><given-names>D</given-names></name></person-group><article-title>The influence of abutment surface roughness on plaque accumulation and peri-implant mucositis</article-title><source>Clin Oral Implants Res</source><year>1996</year><volume>7</volume><fpage>201</fpage><lpage>211</lpage><pub-id pub-id-type="pmid">9151584</pub-id></element-citation></ref><ref id="B16-rde-45-e13"><label>16</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Roselino</surname><given-names>LM</given-names></name><name><surname>Cruvinel</surname><given-names>DR</given-names></name><name><surname>Chinelatti</surname><given-names>MA</given-names></name><name><surname>Pires-de-Souza</surname><given-names>FC</given-names></name></person-group><article-title>Effect of brushing and accelerated ageing on color stability and surface roughness of composites</article-title><source>J Dent</source><year>2013</year><volume>41</volume><issue>Supplement 5</issue><fpage>e54</fpage><lpage>e61</lpage><pub-id pub-id-type="pmid">23851131</pub-id></element-citation></ref><ref id="B17-rde-45-e13"><label>17</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Catelan</surname><given-names>A</given-names></name><name><surname>Briso</surname><given-names>AL</given-names></name><name><surname>Sundfeld</surname><given-names>RH</given-names></name><name><surname>Dos Santos</surname><given-names>PH</given-names></name></person-group><article-title>Effect of artificial aging on the roughness and microhardness of sealed composites</article-title><source>J Esthet Restor Dent</source><year>2010</year><volume>22</volume><fpage>324</fpage><lpage>330</lpage><pub-id pub-id-type="pmid">21029336</pub-id></element-citation></ref><ref id="B18-rde-45-e13"><label>18</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ferracane</surname><given-names>JL</given-names></name></person-group><article-title>Resin composite--state of the art</article-title><source>Dent Mater</source><year>2011</year><volume>27</volume><fpage>29</fpage><lpage>38</lpage><pub-id pub-id-type="pmid">21093034</pub-id></element-citation></ref><ref id="B19-rde-45-e13"><label>19</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ghinea</surname><given-names>R</given-names></name><name><surname>P&#xE9;rez</surname><given-names>MM</given-names></name><name><surname>Herrera</surname><given-names>LJ</given-names></name><name><surname>Rivas</surname><given-names>MJ</given-names></name><name><surname>Yebra</surname><given-names>A</given-names></name><name><surname>Paravina</surname><given-names>RD</given-names></name></person-group><article-title>Color difference thresholds in dental ceramics</article-title><source>J Dent</source><year>2010</year><volume>38</volume><issue>Supplement 2</issue><fpage>e57</fpage><lpage>e64</lpage><pub-id pub-id-type="pmid">20670670</pub-id></element-citation></ref><ref id="B20-rde-45-e13"><label>20</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Biradar</surname><given-names>B</given-names></name><name><surname>Biradar</surname><given-names>S</given-names></name><name><surname>Ms</surname><given-names>A</given-names></name></person-group><article-title>Evaluation of the effect of water on three different light cured composite restorative materials stored in water: an in vitro study</article-title><source>Int J Dent</source><year>2012</year><volume>2012</volume><elocation-id>640942</elocation-id><pub-id pub-id-type="pmid">22315607</pub-id></element-citation></ref><ref id="B21-rde-45-e13"><label>21</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Patel</surname><given-names>J</given-names></name><name><surname>Granger</surname><given-names>C</given-names></name><name><surname>Parker</surname><given-names>S</given-names></name><name><surname>Patel</surname><given-names>M</given-names></name></person-group><article-title>The effect of instrument lubricant on the diametral tensile strength and water uptake of posterior composite restorative material</article-title><source>J Dent</source><year>2017</year><volume>56</volume><fpage>33</fpage><lpage>38</lpage><pub-id pub-id-type="pmid">27746333</pub-id></element-citation></ref><ref id="B22-rde-45-e13"><label>22</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Araujo</surname><given-names>FS</given-names></name><name><surname>Barros</surname><given-names>MC</given-names></name><name><surname>Santana</surname><given-names>ML</given-names></name><name><surname>de Jesus Oliveira</surname><given-names>LS</given-names></name><name><surname>Silva</surname><given-names>PF</given-names></name><name><surname>Lima</surname><given-names>GD</given-names></name><name><surname>Faria-E-Silva</surname><given-names>AL</given-names></name></person-group><article-title>Effects of adhesive used as modeling liquid on the stability of the color and opacity of composites</article-title><source>J Esthet Restor Dent</source><year>2018</year><volume>30</volume><fpage>427</fpage><lpage>433</lpage><pub-id pub-id-type="pmid">29607618</pub-id></element-citation></ref><ref id="B23-rde-45-e13"><label>23</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Prodan</surname><given-names>DA</given-names></name><name><surname>Gasparik</surname><given-names>C</given-names></name><name><surname>Mada</surname><given-names>DC</given-names></name><name><surname>Micl&#x103;u&#x15F;</surname><given-names>V</given-names></name><name><surname>B&#x103;ciu&#x163;</surname><given-names>M</given-names></name><name><surname>Dudea</surname><given-names>D</given-names></name></person-group><article-title>Influence of opacity on the color stability of a nanocomposite</article-title><source>Clin Oral Investig</source><year>2015</year><volume>19</volume><fpage>867</fpage><lpage>875</lpage></element-citation></ref></ref-list></back></article>
