<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "JATS-journalpublishing1.dtd">
<article article-type="review-article" dtd-version="1.0" xml:lang="en" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">jkssh</journal-id>
<journal-title-group>
<journal-title>Journal of the Korean Society for Surgery of the Hand</journal-title>
<abbrev-journal-title>J Korean Soc Surg Hand</abbrev-journal-title>
</journal-title-group>
<issn pub-type="ppub">1598-3889</issn>
<issn pub-type="epub">2234-0998</issn>
<publisher>
<publisher-name>The Korean Society for Surgery of the Hand</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.12790/jkssh.2016.21.3.105</article-id>
<article-id pub-id-type="publisher-id">jkssh-21-105</article-id>
<article-categories>
<subj-group>
<subject>REVIEW ARTICLE</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Ultrasonography-Guided Surgery around the Wrist and Hand</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name name-style="western" xml:lang="en"><surname>Kang</surname><given-names>Hong Je</given-names></name><xref ref-type="aff" rid="aff1-jkssh-21-105"/><xref ref-type="corresp" rid="c1-jkssh-21-105"/>
</contrib>
<contrib contrib-type="author">
<name name-style="western" xml:lang="en"><surname>Kim</surname><given-names>Se Jin</given-names></name><xref ref-type="aff" rid="aff1-jkssh-21-105"/>
</contrib>
<aff id="aff1-jkssh-21-105" xml:lang="en">Department of Orthopedic Surgery, Wonkwang University Hospital, Wonkwang University School of Medicine, Iksan, <country>Korea</country></aff>
</contrib-group>
<author-notes>
<corresp id="c1-jkssh-21-105"><bold>Correspondence to:</bold> Hong Je Kang, Department of Orthopaedic Surgery, Wonkwang University School of Medicine, 895 Muwang-ro, Iksan 54538, Korea, TEL: +82-63-859-1360, FAX: +82-63-852-9329, E-mail: <email>kanghongje@hanmail.net</email></corresp>
<fn><label>*</label><p>This paper was supported by Wonkwang University n 2016.</p></fn>
</author-notes>
<pub-date pub-type="ppub">
<month>09</month>
<year>2016</year>
</pub-date>
<pub-date pub-type="epub">
<day>11</day>
<month>09</month>
<year>2016</year>
</pub-date>
<volume>21</volume>
<issue>3</issue>
<fpage>105</fpage>
<lpage>112</lpage>
<history>
<date date-type="received"><day>26</day><month>05</month><year>2016</year></date>
<date date-type="revised"><day>11</day><month>08</month><year>2016</year></date>
<date date-type="accepted"><day>14</day><month>08</month><year>2016</year></date>
</history>
<permissions>
<copyright-statement>Copyright &#x00A9; 2016 The Korean Society for Surgery of the Hand</copyright-statement>
<copyright-year>2016</copyright-year>
<license><license-p>This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (<ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by-nc/3.0/">http://creativecommons.org/licenses/by-nc/3.0/</ext-link>) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p></license>
</permissions>
<abstract xml:lang="en">
<p>Ultrasonography is used commonly for diagnosis and treatment in orthopedic field, because of low cost and radiation free imaging. Especially, in hand and wrist, where anatomical structures are located superficially, ultrasonography is very useful. Furthermore, major structures could be seen real-time, increasing safety and accuracy in operation. Therefore, some authors are trying ultrasonography-guided surgery around wrist and hand. This article reviewed the ultrasonography-guided surgery around wrist and hand with its technique, indication, and contraindication.</p>
</abstract>
<kwd-group xml:lang="en">
<kwd>Ultrasonography</kwd>
<kwd>Surgery</kwd>
<kwd>Wrist</kwd>
<kwd>Hand</kwd>
</kwd-group>
</article-meta>
</front>
<back>
<ref-list>
<title>REFERENCES</title>
<ref id="b1-jkssh-21-105"><label>1</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>del Cura</surname><given-names>JL</given-names></name></person-group><article-title>Ultrasound-guided therapeutic procedures in the musculoskeletal system</article-title><source>Curr Probl Diagn Radiol</source><year>jkssh-21-1058</year><volume>37</volume><fpage>203</fpage><lpage>18</lpage></element-citation></ref>
<ref id="b2-jkssh-21-105"><label>2</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Orlandi</surname><given-names>D</given-names></name><name><surname>Corazza</surname><given-names>A</given-names></name><name><surname>Silvestri</surname><given-names>E</given-names></name><etal/></person-group><article-title>Ultrasound-guided procedures around the wrist and hand: how to do</article-title><source>Eur J Radiol</source><year>2014</year><volume>83</volume><fpage>1231</fpage><lpage>8</lpage></element-citation></ref>
<ref id="b3-jkssh-21-105"><label>3</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Jou</surname><given-names>IM</given-names></name><name><surname>Chern</surname><given-names>TC</given-names></name></person-group><article-title>Sonographically assisted percutaneous release of the a1 pulley: a new surgical technique for treating trigger digit</article-title><source>J Hand Surg Br</source><year>jkssh-21-1056</year><volume>31</volume><fpage>191</fpage><lpage>9</lpage></element-citation></ref>
<ref id="b4-jkssh-21-105"><label>4</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Rojo-Manaute</surname><given-names>JM</given-names></name><name><surname>Capa-Grasa</surname><given-names>A</given-names></name><name><surname>Del Cerro-Gutierrez</surname><given-names>M</given-names></name><name><surname>Martinez</surname><given-names>MV</given-names></name><name><surname>Chana-Rodriguez</surname><given-names>F</given-names></name><name><surname>Martin</surname><given-names>JV</given-names></name></person-group><article-title>Sonographically guided intrasheath percutaneous release of the first annular pulley for trigger digits, part 2: randomized comparative study of the economic impact of 3 surgical models</article-title><source>J Ultrasound Med</source><year>2012</year><volume>31</volume><fpage>427</fpage><lpage>38</lpage></element-citation></ref>
<ref id="b5-jkssh-21-105"><label>5</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Gulabi</surname><given-names>D</given-names></name><name><surname>Cecen</surname><given-names>GS</given-names></name><name><surname>Bekler</surname><given-names>HI</given-names></name><name><surname>Saglam</surname><given-names>F</given-names></name><name><surname>Tanju</surname><given-names>N</given-names></name></person-group><article-title>A study of 60 patients with percutaneous trigger finger releases: clinical and ultrasonographic findings</article-title><source>J Hand Surg Eur Vol</source><year>2014</year><volume>39</volume><fpage>699</fpage><lpage>703</lpage></element-citation></ref>
<ref id="b6-jkssh-21-105"><label>6</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Quinnell</surname><given-names>RC</given-names></name></person-group><article-title>Conservative management of trigger finger</article-title><source>Practitioner</source><year>1980</year><volume>224</volume><fpage>187</fpage><lpage>90</lpage></element-citation></ref>
<ref id="b7-jkssh-21-105"><label>7</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Lorthioir</surname><given-names>J</given-names><suffix>Jr</suffix></name></person-group><article-title>Surgical treatment of trigger-finger by a subcutaneous method</article-title><source>J Bone Joint Surg Am</source><year>1958</year><volume>40</volume><fpage>793</fpage><lpage>5</lpage></element-citation></ref>
<ref id="b8-jkssh-21-105"><label>8</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Park</surname><given-names>MJ</given-names></name><name><surname>Oh</surname><given-names>I</given-names></name><name><surname>Ha</surname><given-names>KI</given-names></name></person-group><article-title>A1 pulley release of locked trigger digit by percutaneous technique</article-title><source>J Hand Surg Br</source><year>jkssh-21-1054</year><volume>29</volume><fpage>502</fpage><lpage>5</lpage></element-citation></ref>
<ref id="b9-jkssh-21-105"><label>9</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Ha</surname><given-names>KI</given-names></name><name><surname>Park</surname><given-names>MJ</given-names></name><name><surname>Ha</surname><given-names>CW</given-names></name></person-group><article-title>Percutaneous release of trigger digits</article-title><source>J Bone Joint Surg Br</source><year>jkssh-21-1051</year><volume>83</volume><fpage>75</fpage><lpage>7</lpage></element-citation></ref>
<ref id="b10-jkssh-21-105"><label>10</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Paulius</surname><given-names>KL</given-names></name><name><surname>Maguina</surname><given-names>P</given-names></name></person-group><article-title>Ultrasound-assisted percutaneous trigger finger release: is it safe?</article-title><source>Hand (N Y).</source><year>jkssh-21-1059</year><volume>4</volume><fpage>35</fpage><lpage>7</lpage></element-citation></ref>
<ref id="b11-jkssh-21-105"><label>11</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Rajeswaran</surname><given-names>G</given-names></name><name><surname>Lee</surname><given-names>JC</given-names></name><name><surname>Eckersley</surname><given-names>R</given-names></name><name><surname>Katsarma</surname><given-names>E</given-names></name><name><surname>Healy</surname><given-names>JC</given-names></name></person-group><article-title>Ultrasound-guided percutaneous release of the annular pulley in trigger digit</article-title><source>Eur Radiol</source><year>jkssh-21-1059</year><volume>19</volume><fpage>2232</fpage><lpage>7</lpage></element-citation></ref>
<ref id="b12-jkssh-21-105"><label>12</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Rojo-Manaute</surname><given-names>JM</given-names></name><name><surname>Rodriguez-Maruri</surname><given-names>G</given-names></name><name><surname>Capa-Grasa</surname><given-names>A</given-names></name><name><surname>Chana-Rodriguez</surname><given-names>F</given-names></name><name><surname>Soto Mdel</surname><given-names>V</given-names></name><name><surname>Martin</surname><given-names>JV</given-names></name></person-group><article-title>Sonographically guided intrasheath percutaneous release of the first annular pulley for trigger digits, part 1: clinical efficacy and safety</article-title><source>J Ultrasound Med</source><year>2012</year><volume>31</volume><fpage>417</fpage><lpage>24</lpage></element-citation></ref>
<ref id="b13-jkssh-21-105"><label>13</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Lu</surname><given-names>SC</given-names></name><name><surname>Kuo</surname><given-names>LC</given-names></name><name><surname>Hsu</surname><given-names>HY</given-names></name><name><surname>Jou</surname><given-names>IM</given-names></name><name><surname>Sun</surname><given-names>YN</given-names></name><name><surname>Su</surname><given-names>FC</given-names></name></person-group><article-title>Finger movement function after ultrasound-guided percutaneous pulley release for trigger finger: effects of postoperative rehabilitation</article-title><source>Arch Phys Med Rehabil</source><year>2015</year><volume>96</volume><fpage>91</fpage><lpage>7</lpage></element-citation></ref>
<ref id="b14-jkssh-21-105"><label>14</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Scholten</surname><given-names>RJ</given-names></name><name><surname>Gerritsen</surname><given-names>AA</given-names></name><name><surname>Uitdehaag</surname><given-names>BM</given-names></name><name><surname>van Geldere</surname><given-names>D</given-names></name><name><surname>de Vet</surname><given-names>HC</given-names></name><name><surname>Bouter</surname><given-names>LM</given-names></name></person-group><article-title>Surgical treatment options for carpal tunnel syndrome</article-title><source>Cochrane Database Syst Rev.</source><year>2002</year><issue>4</issue><comment>CD003905</comment></element-citation></ref>
<ref id="b15-jkssh-21-105"><label>15</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Keith</surname><given-names>MW</given-names></name><name><surname>Masear</surname><given-names>V</given-names></name><name><surname>Amadio</surname><given-names>PC</given-names></name><etal/></person-group><article-title>Treatment of carpal tunnel syndrome</article-title><source>J Am Acad Orthop Surg</source><year>jkssh-21-1059</year><volume>17</volume><fpage>397405</fpage></element-citation></ref>
<ref id="b16-jkssh-21-105"><label>16</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Nakamichi</surname><given-names>K</given-names></name><name><surname>Tachibana</surname><given-names>S</given-names></name></person-group><article-title>Ultrasonographically assisted carpal tunnel release</article-title><source>J Hand Surg Am</source><year>1997</year><volume>22</volume><fpage>853</fpage><lpage>62</lpage></element-citation></ref>
<ref id="b17-jkssh-21-105"><label>17</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Nakamichi</surname><given-names>K</given-names></name><name><surname>Tachibana</surname><given-names>S</given-names></name><name><surname>Yamamoto</surname><given-names>S</given-names></name><name><surname>Ida</surname><given-names>M</given-names></name></person-group><article-title>Percutaneous carpal tunnel release compared with mini-open release using ultrasonographic guidance for both techniques</article-title><source>J Hand Surg Am</source><year>2010</year><volume>35</volume><fpage>437</fpage><lpage>45</lpage></element-citation></ref>
<ref id="b18-jkssh-21-105"><label>18</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>de la Fuente</surname><given-names>J</given-names></name><name><surname>Miguel-Perez</surname><given-names>MI</given-names></name><name><surname>Balius</surname><given-names>R</given-names></name><name><surname>Guerrero</surname><given-names>V</given-names></name><name><surname>Michaud</surname><given-names>J</given-names></name><name><surname>Bong</surname><given-names>D</given-names></name></person-group><article-title>Minimally invasive ultrasound-guided carpal tunnel release: a cadaver study</article-title><source>J Clin Ultrasound</source><year>2013</year><volume>41</volume><fpage>101</fpage><lpage>7</lpage></element-citation></ref>
<ref id="b19-jkssh-21-105"><label>19</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Rowe</surname><given-names>NM</given-names></name><name><surname>Michaels</surname><given-names>Jt</given-names></name><name><surname>Soltanian</surname><given-names>H</given-names></name><name><surname>Dobryansky</surname><given-names>M</given-names></name><name><surname>Peimer</surname><given-names>CA</given-names></name><name><surname>Gurtner</surname><given-names>GC</given-names></name></person-group><article-title>Sonographically guided percutaneous carpal tunnel release: an anatomic and cadaveric study</article-title><source>Ann Plast Surg</source><year>jkssh-21-1055</year><volume>55</volume><fpage>52</fpage><lpage>6</lpage></element-citation></ref>
<ref id="b20-jkssh-21-105"><label>20</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Lecoq</surname><given-names>B</given-names></name><name><surname>Hanouz</surname><given-names>N</given-names></name><name><surname>Vielpeau</surname><given-names>C</given-names></name><name><surname>Marcelli</surname><given-names>C</given-names></name></person-group><article-title>Ultrasound-guided percutaneous surgery for carpal tunnel syndrome: a cadaver study</article-title><source>Joint Bone Spine</source><year>2011</year><volume>78</volume><fpage>516</fpage><lpage>8</lpage></element-citation></ref>
<ref id="b21-jkssh-21-105"><label>21</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Lanz</surname><given-names>U</given-names></name></person-group><article-title>Anatomical variations of the median nerve in the carpal tunnel</article-title><source>J Hand Surg Am</source><year>1977</year><volume>2</volume><fpage>44</fpage><lpage>53</lpage></element-citation></ref>
<ref id="b22-jkssh-21-105"><label>22</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Mirza</surname><given-names>MA</given-names></name><name><surname>King</surname><given-names>ET</given-names><suffix>Jr</suffix></name></person-group><article-title>Newer techniques of carpal tunnel release</article-title><source>Orthop Clin North Am</source><year>1996</year><volume>27</volume><fpage>355</fpage><lpage>71</lpage></element-citation></ref>
</ref-list>
<sec sec-type="display-objects">
<title>Figures</title>
<fig id="f1-jkssh-21-105" position="float">
<label>Fig. 1.</label><caption><p><bold>(A)</bold> Surgical instruments for ultrasonography-guided percutaneous A1 pulley release: 24-gauge needle, 18-gauge needle, Haki knife and probe. <bold>(B)</bold> The anatomical landmarks. The needle and Haki knife were inserted 1 cm distal to the proximal crease of the thumb, and at the basal crease of the fingers.</p></caption>
<graphic xlink:href="jkssh-21-105f1.tif"/>
</fig>
<fig id="f2-jkssh-21-105" position="float">
<label>Fig. 2.</label><caption><p><bold>(A)</bold> The transducer was positioned at the center of the metacarpophalangeal (MCP) joint and along the mid-line of the flexor tendon. <bold>(B)</bold> Longitudinal section of sonogram. <bold>(C, D)</bold> Haki knife inserted to just proximal of the A1 pulley on top of the midline of flexor tendon. Haki knife was hooked around proximal edge of the A1 pulley and the pulley was sectioned by moving the knife from proximal to distal. <bold>(E)</bold> When A1 pulley is completely released, there is no resistance when probe was gliding over flexor tendons.</p></caption>
<graphic xlink:href="jkssh-21-105f2.tif"/>
</fig>
<fig id="f3-jkssh-21-105" position="float">
<label>Fig. 3.</label><caption><p><bold>(A)</bold> Surgical instruments for ultrasonography-guided percutaneous Carpal tunnel release: probe, Freer elevator, dilator, slotted cannula, trocar, endoscopic cutting devices. <bold>(B-D)</bold> The anatomical landmarks: superficial palmar arch (SPA), median nerve (M), ulnar artery (UA), transverse carpal ligament (TCL) (arrowheads). <bold>(E)</bold> Check the course of the median nerve in longitudinal view. FDS, flexor digitorum superficialis.</p></caption>
<graphic xlink:href="jkssh-21-105f3.tif"/>
</fig>
<fig id="f4-jkssh-21-105" position="float">
<label>Fig. 4.</label><caption><p>The safe line is defined as midline between the ulnar margin of the median nerve and the radial margin of the ulnar artery. All instruments must be passed along this line under ultrasonographic monitoring.</p></caption>
<graphic xlink:href="jkssh-21-105f4.tif"/>
</fig>
<fig id="f5-jkssh-21-105" position="float">
<label>Fig. 5.</label><caption><p><bold>(A)</bold> Freer elevator or probe passing under surface <bold>(B)</bold> and over surface <bold>(C)</bold> of the TCL. Axial view of sonogram, the probe (arrow) is always passed along the safe line. <bold>(D)</bold> Slotted cannula with trocar was inserted beneath the TCL along safe line. After trocar removal, Cutting device is inserted inside slotted cannula. Release of the TCL was done from proximal to distal edge or reversely. All procedure must be done under ultrasonographic monitoring. <bold>(E)</bold> The TCL is located between two cutter blade. <bold>(F)</bold> After the device removal, release was confirmed. TCL, transverse carpal ligament; M, median nerve; UA, ulnar artery.</p></caption>
<graphic xlink:href="jkssh-21-105f5.tif"/>
</fig>
</sec>
</back>
</article>