<?xml version="1.0" encoding="utf-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.0 20120330//EN" "JATS-journalpublishing1.dtd">
<article article-type="research-article" dtd-version="1.0" xml:lang="en" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">JKSSH</journal-id>
<journal-title-group>
<journal-title xml:lang="en">Journal of the Korean Society for Surgery of the Hand</journal-title>
<abbrev-journal-title abbrev-type="publisher" xml:lang="en">J Korean Soc Surg Hand</abbrev-journal-title>
</journal-title-group>
<issn pub-type="ppub">1598-3889</issn>
<issn pub-type="epub">2234-0998</issn>
<publisher>
<publisher-name>The Korean Society for Surgery of the Hand</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="doi">10.12790/jkssh.2013.18.4.178</article-id>
<article-id pub-id-type="publisher-id">jkssh-18-178</article-id>
<article-categories>
<subj-group>
<subject>Case Report</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Failure of Distal Locking Screws in an Intraarticular Distal Radius Fracture Treated with Volar Locking Plate Fixation</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name name-style="western" xml:lang="en"><surname>Lee</surname><given-names>Su Keon</given-names></name>
<xref ref-type="aff" rid="aff1-jkssh-18-178"/>
</contrib>
<contrib contrib-type="author">
<name name-style="western" xml:lang="en"><surname>Lee</surname><given-names>Sang Ho</given-names></name>
<xref ref-type="corresp" rid="c1-jkssh-18-178"/>
<xref ref-type="aff" rid="aff1-jkssh-18-178"/>
</contrib>
<contrib contrib-type="author">
<name name-style="western" xml:lang="en"><surname>Choi</surname><given-names>Uk Hyun</given-names></name>
<xref ref-type="aff" rid="aff1-jkssh-18-178"/>
</contrib>
<aff id="aff1-jkssh-18-178" xml:lang="en">Department of Orthopedic Surgery, Gwangmyeong Sung-Ae General Hospital, Gwangmyeong, <country>Korea</country></aff>
</contrib-group>
<author-notes>
<corresp id="c1-jkssh-18-178"><bold>Correspondence to:</bold> Sang Ho Lee Department of Orthopedic Surgery, Gwangmyeong Sung-Ae General Hospital, 36 Digital-ro, Gwangmyeong 423-711, Korea TEL: +82-2-2680-7236 FAX: +82-2-2617-9039 E-mail: <email>ostitch79@naver.com</email></corresp>
</author-notes>
<pub-date pub-type="ppub">
<month>12</month>
<year>2013</year>
</pub-date>
<pub-date pub-type="epub">
<day>12</day>
<month>12</month>
<year>2013</year>
</pub-date>
<volume>18</volume><issue>4</issue>
<fpage>178</fpage>
<lpage>183</lpage>
<history>
<date date-type="received">
<day>30</day><month>09</month><year>2013</year></date>
<date date-type="revised">
<day>29</day><month>11</month><year>2013</year></date>
<date date-type="accepted">
<day>03</day><month>12</month><year>2013</year></date>
</history>
<permissions>
<copyright-statement>Copyright &#x00A9; 2013 The Korean Society for Surgery of the Hand</copyright-statement>
<copyright-year>2013</copyright-year>
<license><license-p>This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (<ext-link ext-link-type="uri" xlink:href="http://creativecommons.org/licenses/by-nc/3.0/">http://creativecommons.org/licenses/by-nc/3.0/</ext-link>) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.</license-p></license>
</permissions>
<abstract xml:lang="en">
<title>Abstract</title>
<p>Distal radius fracture is one of the most common fractures treated in the orthopedic field. The application of locking plate principle to the distal radius has allowed comminuted distal radius fractures involving the articular surface to be effectively treated by open reduction and internal fixation. The authors experienced a case of failure of distal locking screws in an intraarticular distal radius fracture treated with volar locking plate fixation.</p>
</abstract>
<kwd-group xml:lang="en">
<kwd>Intraarticular distal radius fracture</kwd>
<kwd>Locking plate</kwd>
<kwd>Failure of screw</kwd>
</kwd-group>
</article-meta>
</front>
<back>
<ref-list>
<title>REFERENCES</title>
<ref id="b1-jkssh-18-178"><label>1</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Chung</surname><given-names>KC</given-names></name><name><surname>Spilson</surname><given-names>SV</given-names></name></person-group><article-title>The frequency and epidemiology of hand and forearm fractures in the United States</article-title><source>J Hand Surg Am</source><year>2001</year><volume>26</volume><fpage>908</fpage><lpage>15</lpage></element-citation></ref>
<ref id="b2-jkssh-18-178"><label>2</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Khan</surname><given-names>SK</given-names></name><name><surname>Gozzard</surname><given-names>C</given-names></name></person-group><article-title>Union of an intra-articular distal radius fracture after successive failures of three locking plates: a case report</article-title><source>Strategies Trauma Limb Reconstr</source><year>2012</year><volume>7</volume><fpage>45</fpage><lpage>50</lpage></element-citation></ref>
<ref id="b3-jkssh-18-178"><label>3</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Al-Rashid</surname><given-names>M</given-names></name><name><surname>Theivendran</surname><given-names>K</given-names></name><name><surname>Craigen</surname><given-names>MA</given-names></name></person-group><article-title>Delayed ruptures of the extensor tendon secondary to the use of volar locking compression plates for distal radial fractures</article-title><source>J Bone Joint Surg Br</source><year>2006</year><volume>88</volume><fpage>1610</fpage><lpage>2</lpage></element-citation></ref>
<ref id="b4-jkssh-18-178"><label>4</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Arora</surname><given-names>R</given-names></name><name><surname>Lutz</surname><given-names>M</given-names></name><name><surname>Hennerbichler</surname><given-names>A</given-names></name><name><surname>Krappinger</surname><given-names>D</given-names></name><name><surname>Espen</surname><given-names>D</given-names></name><name><surname>Gabl</surname><given-names>M</given-names></name></person-group><article-title>Complications following internal fixation of unstable distal radius fracture with a palmar lockingplate</article-title><source>J Orthop Trauma</source><year>2007</year><volume>21</volume><fpage>316</fpage><lpage>22</lpage></element-citation></ref>
<ref id="b5-jkssh-18-178"><label>5</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Cao</surname><given-names>J</given-names></name><name><surname>Ozer</surname><given-names>K</given-names></name></person-group><article-title>Failure of volar locking plate fixation of an extraarticular distal radius fracture: a case report</article-title><source>Patient Saf Surg</source><year>2010</year><volume>4</volume><fpage>19</fpage></element-citation></ref>
<ref id="b6-jkssh-18-178"><label>6</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>De Baere</surname><given-names>T</given-names></name><name><surname>Lecouvet</surname><given-names>F</given-names></name><name><surname>Barbier</surname><given-names>O</given-names></name></person-group><article-title>Breakage of a volar locking plate after delayed union of a distal radius fracture</article-title><source>Acta Orthop Belg</source><year>2007</year><volume>73</volume><fpage>785</fpage><lpage>90</lpage></element-citation></ref>
<ref id="b7-jkssh-18-178"><label>7</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Imade</surname><given-names>S</given-names></name><name><surname>Matsuura</surname><given-names>Y</given-names></name><name><surname>Miyamoto</surname><given-names>W</given-names></name><name><surname>Nishi</surname><given-names>H</given-names></name><name><surname>Uchio</surname><given-names>Y</given-names></name></person-group><article-title>Breakage of a volar locking compression plate in distal radial fracture</article-title><source>Injury Extra</source><year>2009</year><volume>40</volume><fpage>77</fpage><lpage>80</lpage></element-citation></ref>
<ref id="b8-jkssh-18-178"><label>8</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Yukata</surname><given-names>K</given-names></name><name><surname>Doi</surname><given-names>K</given-names></name><name><surname>Hattori</surname><given-names>Y</given-names></name><name><surname>Sakamoto</surname><given-names>S</given-names></name></person-group><article-title>Early breakage of a titanium volar locking plate for fixation of a distal radius fracture: case report</article-title><source>J Hand Surg Am</source><year>2009</year><volume>34</volume><fpage>907</fpage><lpage>9</lpage></element-citation></ref>
<ref id="b9-jkssh-18-178"><label>9</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Mehling</surname><given-names>I</given-names></name><name><surname>Muller</surname><given-names>LP</given-names></name><name><surname>Delinsky</surname><given-names>K</given-names></name><name><surname>Mehler</surname><given-names>D</given-names></name><name><surname>Burkhart</surname><given-names>KJ</given-names></name><name><surname>Rommens</surname><given-names>PM</given-names></name></person-group><article-title>Number and locations of screw fixation for volar fixed-angle plating of distal radius fractures: biomechanical study</article-title><source>J Hand Surg Am</source><year>2010</year><volume>35</volume><fpage>885</fpage><lpage>91</lpage></element-citation></ref>
<ref id="b10-jkssh-18-178"><label>10</label><element-citation publication-type="journal"><person-group person-group-type="author"><name><surname>Crosby</surname><given-names>SN</given-names></name><name><surname>Fletcher</surname><given-names>ND</given-names></name><name><surname>Yap</surname><given-names>ER</given-names></name><name><surname>Lee</surname><given-names>DH</given-names></name></person-group><article-title>The mechanical stability of extra-articular distal radius fractures with respect to the number of screws securing the distal fragment</article-title><source>J Hand Surg Am</source><year>2013</year><volume>38</volume><fpage>1097</fpage><lpage>105</lpage></element-citation></ref>
</ref-list>
<sec sec-type="display-objects">
<title>Figures</title>
<fig id="f1-jkssh-18-178" position="float">
<label>Fig. 1.</label>
<caption><p>Initial <bold>(A)</bold> anteroposterior and <bold>(B)</bold> lateral radiographic view after injury, showing the distal radius fracture.</p></caption>
<graphic xlink:href="jkssh-18-178f1.tif"/>
</fig>
<fig id="f2-jkssh-18-178" position="float">
<label>Fig. 2.</label>
<caption><p>At operative day <bold>(A)</bold> anteroposterior and <bold>(B)</bold> lateral radiographs after open reduction and internal fixation with volar locking plate.</p></caption>
<graphic xlink:href="jkssh-18-178f2.tif"/>
</fig>
<fig id="f3-jkssh-18-178" position="float">
<label>Fig. 3.</label>
<caption><p>Radiographs show <bold>(A)</bold> dorsal angulation of the fracture following failure of screws. Despite the failure of screws, the lateral radiograph showed neutral alignment of the distal radius articular surface with <bold>(B)</bold> minimal shortening on the anteroposterior plane. <bold>(C)</bold> Photographs shows breakage of distal locking screws of volar locking plate due to overload from trekking pole.</p></caption>
<graphic xlink:href="jkssh-18-178f3.tif"/>
</fig>
<fig id="f4-jkssh-18-178" position="float">
<label>Fig. 4.</label>
<caption><p>Twenty weeks after the last surgery, <bold>(A)</bold> anteroposterior and <bold>(B)</bold> lateral radiographs show consolidation at the fracture site.</p></caption>
<graphic xlink:href="jkssh-18-178f4.tif"/>
</fig>
</sec>
</back>
</article>