<?xml version="1.0" encoding="UTF-8"?><!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.1 20151215//EN" "JATS-journalpublishing1.dtd"><article xml:lang="KO" article-type="research-article">
		<front>
	<journal-meta>
		<journal-id journal-id-type="nlm-ta">J Korean Radiol Soc</journal-id>
		<journal-id journal-id-type="publisher-id">JKRS</journal-id>
		<journal-title-group>
			<journal-title>Journal of the Korean Radiological Society</journal-title>
		</journal-title-group>
		<issn pub-type="ppub">0301-2867</issn>
		
		<publisher>
			<publisher-name>The Korean Radiological Society</publisher-name>
		</publisher>
	</journal-meta>
	<article-meta>
		<article-id pub-id-type="doi">10.3348/jkrs.1998.38.4.595</article-id>
		<article-categories>
			<subj-group>
				<subject>Original Article</subject>
			</subj-group>
		</article-categories>
		<title-group>
			<article-title>Usefulness of CISS Technique in the MR Imaging Diagnosis of Intraocular Lesions</article-title>
		</title-group>
		<contrib-group>
			<contrib contrib-type="author">
				<name>
					<surname>Jung</surname>
					<given-names>Hyun Woo</given-names>
				</name>
				<xref ref-type="aff" rid="A1"></xref>
			</contrib>
			<contrib contrib-type="author">
				<name>
					<surname>Kim</surname>
					<given-names>Hak Jin</given-names>
				</name>
				<xref ref-type="aff" rid="A1"></xref>
			</contrib>
			<contrib contrib-type="author">
				<name>
					<surname>Kim</surname>
					<given-names>Chang Won</given-names>
				</name>
				<xref ref-type="aff" rid="A1"></xref>
			</contrib>
			<contrib contrib-type="author">
				<name>
					<surname>Kim</surname>
					<given-names>Suk</given-names>
				</name>
				<xref ref-type="aff" rid="A1"></xref>
			</contrib>
			<contrib contrib-type="author">
				<name>
					<surname>Kim</surname>
					<given-names>Yong Woo</given-names>
				</name>
				<xref ref-type="aff" rid="A1"></xref>
			</contrib>
			<contrib contrib-type="author">
				<name>
					<surname>Choi</surname>
					<given-names>Sang Yoel</given-names>
				</name>
				<xref ref-type="aff" rid="A1"></xref>
			</contrib>
			<contrib contrib-type="author">
				<name>
					<surname>Lee</surname>
					<given-names>Suck Hong</given-names>
				</name>
				<xref ref-type="aff" rid="A1"></xref>
			</contrib>
			<contrib contrib-type="author">
				<name>
					<surname>Kim</surname>
					<given-names>Byung Soo</given-names>
				</name>
				<xref ref-type="aff" rid="A1"></xref>
			</contrib>
		</contrib-group>
		<aff id="A1">Department of Radiology, College of Medicine, Pusan National University, Korea.</aff>
		<pub-date pub-type="ppub">
			<month>04</month>
			<year>1998</year>
		</pub-date>
		<pub-date pub-type="epub">
			<day>15</day>
			<month>03</month>
			<year>2016</year>
		</pub-date>
		<volume>38</volume>
		<issue>4</issue>
		<fpage>595</fpage>
		<lpage>600</lpage>
		<permissions>
			<copyright-statement>Copyright &#x00A9; The Korean Radiological Society</copyright-statement>
			<copyright-year>1998</copyright-year>
		</permissions>
		<abstract>
			<p>
				PURPOSE: To assess the usefulness of CISS images in the diagnosis of intraocular lesions, we compared CISSimages with 3mm and 1mm sliced spin-echo T2-weighted images. 
				MATERIALS AND METHODS: In 14 patients with 15intraocular lesions(retinal detachment 10, choroidal melanoma, 2 ; cavernous hemangioma, 1 ; PHPV, 1 ; andretinoblastoma, 1). we used a 1.5T MR unit obtain CISS images and 3mm and 1mm sliced spin-echo T2-weighted images.All lesions were analyzed, and after dividing them into two subgroups(linear lesions, n=11 ; mass lesions, n=4),CISS and spin-echo T2-weighted images were compared for detection rate and conspicuity. 
				RESULTS: With regard tothese two parameters, CISS images were superior to 1mm and 3mm sliced spin-echo T2-weighted images. For theassessment of linear lesions, CISS images (detection rate, 100% ; conspicuity, 2.88) were superior to both 1mm and3mm sliced spin-echo T2-weighted images. For mass lesions CISS images were superior to 3mm sliced spin-echoT2-weighted images, but for conspicuity, there was no significant difference between CISS images (2.75) and 1mmsliced spin-echo T2-weighted images(2.2). 
				CONCLUSION: Due to their higher detection rate and greater conspicuity,CISS images were superior to spin-echo T2-weighted images for the diagnosis of intraocular lesions less than 3mmin diameter ; for the diagnosis of intraocular lesions, they might therefore be a useful adjunct to SE images.</p>
			</abstract>
			<kwd-group>
				<kwd>Orbit, MR</kwd>
				<kwd>Magnetic resonance (MR), technology</kwd>
				<kwd>Magnetic resonance (MR), three-dimensional</kwd>
			</kwd-group>
		</article-meta>
	</front>
</article>

		
